Filters

Measurement Sensors

719 products

Showing 25 - 48 of 719 products

Showing 25 - 48 of 719 products
View
Keyence New Stock Image
Keyence GT2-71CP Keyence
Sale price $479.46
In stock, 11 units

Specifications

Model

GT2-71CP

Mounting method

DIN-rail mount

Output

PNP output

Main unit/expansion unit

Main unit

Power supply voltage

10 to 30 VDC, including 10 % ripple (P-P), Class 2*1

Power consumption

Normal

2,200 mW max. (30 V, 73.3 mA max.)

Power saving (Eco)

1,700 mW max. (30 V, 56.7 mA max.)

Display power

Measured value display

6 + 1/2-digit 7-segment LED (red)

Other displays

2-color, 13-level bar LED display (red, green), indicators (red, green)

Display range

-199.999.9 to 199.999.9

Display resolution

0.1 μm 0.004 Mil

Control input

Timing/preset/
reset/bank input

No-voltage input

Control output

HH/HI/GO/LO/LL

PNP open collector, 30 V 50 mA or less, residual voltage 1 V or less*1*2

Analog output

-

Response time

hsp(3)/5/10/100/500/1,000 ms
(When using GT2-Pxxx, hsp(12)/20/40/400/2,000/4,000 ms)

Environmental resistance

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET, Cable: PVC

Weight

Approx. 70 g

*1 When adding expansion units, there are the following restrictions according to the number of connected units.
[When 2 to 8 units are connected including the main unit]
Power supply voltage: 20 to 30 VDC
Control output current: 20 mA or less
(GT2-71MCN(P) only) Ambient temperature: -10 to 45°C 14 to 113°F
[When 9 to 15 units are connected including the main unit]
Power supply voltage: 20 to 30 VDC
Control output current: 10 mA or less (including the DL-RB1A output current)
Residual voltage: 1.5 V or lower
(GT2-71MCN(P) only) Ambient temperature: -10 to 45 °C 14 to 113 °F
*2 The GT2-71MCN(P) does not have HH/LL.

Keyence New Stock Image
Keyence GT2-100P Keyence
Sale price $908.91
In stock, 13 units

Specifications

Model

GT2-100P

Mounting method

Panel mount/Screw mounting using optional mounting bracket

Output

PNP output

Main unit/expansion unit

-

Power supply voltage

20 to 30 VDC, including 10 % ripple (P-P), Class 2

Power consumption

Normal

4,500 mW max. (30 V, 150 mA max.)

Power saving (Eco)

3,600 mW max. (30 V, 120 mA max.)*1

Display power

Measured value display

6 + 1/2-digit 7-segment LED (red)

Other displays

2-color, 13-level bar LED display (red, green), indicators (red, green)

Display range

-199.999.9 to 199.999.9

Display resolution

0.1 μm 0.004 Mil

Control input

Timing/preset/
reset/bank input

No-voltage input

Control output

HH/HI/GO/LO/LL

PNP open collector, 30 V 50 mA or less*2, residual voltage 1 V or less

Response time

hsp(3)/5/10/100/500/1,000 ms
(When using GT2-Pxxx, hsp(12)/20/40/400/2,000/4,000 ms)

Environmental resistance

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 0.15 mm 0.006", 2 hours in each of the X, Y, and Z directions

Material

Main body case: Polycarbonate, Key top: Polyacetal, Front sheet: PET

Power supply/I/O cable

Power supply: Terminal block, I/O: 20-pin connector (MIL standard)

Weight

Approx. 380 g

*1 For GT2-100 Series, when the maximum number of sensor heads are connected and all units are set to power saving mode.
*2 When 2 or more sensor heads are connected, 20 mA or less.

Keyence New Stock Image
Keyence GT2-A32 Keyence
Sale price $884.78
In stock, 19 units

Specifications

Model

GT2-A32

Detection system

Quartz glass scale, CMOS image sensor projection system, Absolute type (without tracking error)

Measuring range

32 mm 1.26"

Resolution

0.5 μm 0.02 Mil

Indicated accuracy

3 µm 0.12 Mil (p-p)*1

Measuring force

Downward mounting

2.1 N*2

Side mounting

1.8 N*2

Upward mounting

1.5 N*2

Sampling cycle

1 ms

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67*3

Pressure resistance

1 MPa

Applied pressure range

0.25 to 0.5 MPa

Ambient temperature

0 to +55 °C 32 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions*4

Materials

Main body

Main body case: Zinc die-casting; Cylinder part: Aluminium alloy;
Air joint resin part: Polyacetal; Air joint metal part: Brass nickel plating; Indicator: Polyarylate

Dust boot

NBR

Contact

TYPE304, 440C Stainless steel*5

Sensor head cable

Optional (connect to the M8 connector)

Weight

Approx. 340 g (excluding cable)

*1 Value when the ambient temperature is 20 °C 68 °F.
*2 Value at center of measuring range. Please note that the measurement force changes depending on the installation state of the dust boots.
*3 Make sure the air tube is connected to the air exhaust joint and that no foreign materials enter inside from the joint.
*4 In the case where a mounting bracket D is used with GT2-A32 and GT2-A50, the double amplitude becomes 0.75 mm 0.03".
*5 The contact is included with the sensor.

Keyence New Stock Image
Keyence GT2-S5 Keyence
Sale price $1,135.15
In stock, 16 units

Specifications

Model

GT2-S5*1

Detection system

Differential transformer

Measuring range

5 mm 0.20"*2

Operating range

7 mm 0.28"*2

Resolution

0.1 µm

Indicated accuracy

1 µm (P-P)*3*4

Measuring force

Downward mounting

1.0 N*5

Side mounting

0.95 N*5

Upward mounting

0.9 N*5

Sampling cycle

1 ms

Mechanical response

20 Hz*4

Operation indicator light

2-color LED (red, green)

Environmental resistance

Enclosure rating

IP67G (JIS)*6, IP67 (IEC)

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

10 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2 (IEC60068-2-27)

Materials

Main body

Main body case: SUS430F, Sensor head-relay connector cable: PUR, Relay amplifier: PPSU

Dust boot

NBR

Contact

SUS304, cemented tungsten carbide*7

Sensor head cable

Optional (connect to relay connector)

Weight

Approx. 40 g (not including cable)*8

*1 Note: You may not be able to connect the sensor head to the amplifier unit depending on when the amplifier unit was purchased. For details, contact your local sales office.
*2 The measuring range represents the range at which measured values can be displayed. The operating range is the actual movable range of the spindle.
*3 Within ±0.3 mm 0.012" from the center of the measuring range, the width for any 0.2 mm 0.008" is 1 µm. The entire area is 2 µm.
The linearity for the entire measuring range is ±0.15 % of F.S. (F.S.: 5 mm 0.20")
*4 Value when the ambient temperature is 20 °C 68 °F.
*5 Representative value at the center of the measuring range. Please note that the measuring force varies depending on the installation orientation of the dust boot.
*6 When an M8 oil-resistant cable (GT2-CHP2M/CHP5M/CHP10M) is used for the sensor head cable.
*7 Contacts are available as options sold separately.
*8 Including the relay connector.

EX-110V Keyence
Keyence EX-110V Keyence
Sale price $228.35
In stock, 44 units

Specifications

Model

EX-110V*1

Type

Sensor head

Amplifier unit

NPN: EX-V02
PNP: EX-V02P

Shape

M10 x 18 mm
0.71" Threaded

Measuring range

0 to 2 mm 0 to 0.08"

Display range

-19,999 to +19,999

Linearity

±0.3% of F.S.

Resolution (No. of averaging
measurements: 64)

0.4 μm

Sampling rate

40,000 samplings max./sec. *2

Display speed

20 times/sec.

Display power

7-segment 2-color LED

Over-range alarm

±FFFF is displayed.

Control input

NPN open-collector or non-voltage contact (Timing input, Reset input, Auto-zero input, Comparator output disable input, Synchronous input, External setting input)/PNP: Applied voltage; 10 to 30 V

Control output

Setting method

Upper/lower 2-level setting x 4 patterns (selectable)

Signal

NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.)
PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.)

Response time

0.075 ms (at maximum speed)

OFF-delay time

60 ms

Strobe output

NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.)

Alarm output

NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.)

Analog output voltage

Output voltage

±5V

Impedance

100 Ω

Response time

0.075 ms (at maximum speed)

Temperature characteristics

0.07% of F.S./°C *3

Major functions

FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.

Rating

Power voltage

24 VDC ±10%, Ripple (P-P): 10% max.

Current consumption

240 mA max.

Environmental resistance

Ambient temperature

-10 to +60 °C 14 to 140 °F, No freezing

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 55 g (including 3 m 9.8' cable)

*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials.
*2 When the digital filter function is used, the sampling rate is 20,000 sampling/sec.
*3 When the distance between the sensor head and the target is within 50% of the measuring range.

Keyence Stock Image
Keyence OP-87057 Keyence
Sale price $191.84
Only 8 units left

Specifications

Model

OP-87057

Type

Sensor head cable

Applicable product

IL,IG,GV-T Series head

Cable end

M8 straight - e-con

Length

5 m 16.40'

Material

Cable: Polyvinyl chloride (PVC)

Note

The cable is common to the transmitter and receiver sides, and can be used on either of them.

Weight

Approx. 190 g

Keyence Stock Image
Keyence CB-B3 Keyence
Sale price $216.12
In stock, 12 units

Specifications

Model

CB-B3*1

Type

Head cable

Cable min. bending R

22 mm 0.87"

Cable length

3 m 9.84'

Environmental resistance

Enclosure rating

IP67 (IEC60529)*2

Material

PVC

Weight

Approx. 250 g

*1 Regarding cable extension between the head and controller: Up to 2 cables can be connected with the CB-BxxE, and these cables should be kept to a total length of 30 m 98.4' or less.
*2 This value is from a case in which the sensor head has been connected. However, the controller side connector is not included.

Keyence Stock Image
Keyence CB-B10 Keyence
Sale price $446.94
Only 10 units left

Specifications

Model

CB-B10*1

Type

Head cable

Cable min. bending R

22 mm 0.87"

Cable length

10 m 32.8'

Environmental resistance

Enclosure rating

IP67 (IEC60529)*2

Material

PVC

Weight

Approx. 750 g

*1 Regarding cable extension between the head and controller: Up to 2 cables can be connected with the CB-BxxE, and these cables should be kept to a total length of 30 m 98.4' or less.
*2 This value is from a case in which the sensor head has been connected. However, the controller side connector is not included.

keyence Stock Image
Keyence TM-X5006 Keyence
Sale price$0.00
Sold Out

Specifications

Model

TM-X5006

Transmitter/receiver distance

60 mm 2.36"

Measuring range

Field of view

High-accuracy measurement area

ø4 mm ø0.16"

Measurement area

ø6 mm ø0.24"

Depth of field

High-accuracy measurement area

2 mm 0.08"

Measurement area

4 mm 0.16"

Exposure time

25/50/100 μs (Adjustable 3-stage)

Imaging time (Trigger interval)

Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes)
Approx. 3 ms (at “4/16” vertical/horizontal measurement range sizes)

Light source

InGaN green LED

Measurement position accuracy

High-accuracy measurement area

±0.2 μm ±0.000008" *1

Measurement area

±0.3 μm ±0.000012" *1

Repeatability

±0.03 μm ±0.000001" *2

Pixel resolution

Approx. 3.5 μm 0.000138"

Environmental resistance

Enclosure rating

IP64 *3

Ambient temperature

0 to +45°C 32 to 113°F

Relative humidity

85% RH or less (No condensation)

Material

Aluminum

Weight

Transmitter: Approx. 160 g 5.65 oz
Receiver: Approx. 480 g 16.94 oz
Base: Approx. 210 g 7.41 oz

*1 Error when measuring width of KEYENCE standard object (glass calibration scale).
*2 Average value of ±2σ measuring the width of a KEYENCE standard object (glass calibration scale) 16 times in the center of the measurement area.
*3 Excluding connectors and cable boxes.

Keyence New Stock Image
Keyence TM-X5000 Keyence
Sale price $24,975.00
Only 4 units left

Specifications

Model

TM-X5000

Number of connectable sensor heads

2

Number of setting registrations

Up to 1000 settings (depending on SD card capacity and setting contents) for SD card 1 and SD card 2 individually. External switching is possible.

Memory cards

• SD card slot × 2
• Supports OP-87133 (512 MB), CA-SD1G (1 GB: Equipped as standard for SD1 slot), CA-SD4G (4 GB), CA-SD16G (16 GB)

Number of configurable tools

Up to 100 measurement tools and 100 element tools per head *1

Interface

Control inputs

20 (Terminal block: 5, Parallel I/O: 15)

Control outputs

• 28 (Terminal block: 6, Parallel I/O: 22)
• Photo MOSFET *2

RS-232C

Numerical value output and control input/output

PLC link

Numerical value output and control input/output using Ethernet port
(Cannot be used in conjunction with EtherNet/IP™, PROFINET, and EtherCAT®)
Compatible models: Mitsubishi Electric PLCs (MELSEC Q Series, L Series, iQ-R Series, iQ-F Series)

Ethernet

• Numerical value output and control input/output
• Connection to KEYENCE dedicated monitor (TM-MP120)
• Connection to KEYENCE PC application software
• Support for FTP client/server functions, SFTP client functions, and BOOTP functions
• 1000BASE-T/100BASE-TX/10BASE-T
• Support for jumbo frames (Ethernet port on main unit only)

USB

• Connection to KEYENCE dedicated monitor (TM-MP120)
• Connection to KEYENCE PC application software
• USB 2.0 only

EtherNet/IP™

• Numerical value output and control input/output using Ethernet port or optional EtherNet/IP™ unit CB-NEP20E
(Cannot be used in conjunction with PLC link, PROFINET, and EtherCAT®)
• Supports cyclic communication (max. 1436 bytes) and message communication
• Maximum connections: 32 (Ethernet port) / 1: Exclusive Owner, 4: Input only (CB-NEP20E)
• Conforms to conformance test Version CT17 (Ethernet port) / CT17 (CB-NEP20E)

PROFINET

• Numerical value output and control input/output using Ethernet port or optional PROFINET unit CB-NPN20EA (Cannot be used in conjunction with PLC link, EtherNet/IP™, and EtherCAT®)
• Supports cyclic communication (max. 1408 bytes (Ethernet port) / 1212 bytes (CB-NPN20EA))
• Supports non-cyclic communication (recorded data)
• Conforms to Conformance Class A (Ethernet port) / C (CB-NPN20EA)

EtherCAT®

• Numerical value output and control input/output using optional EtherCAT® unit CB-NEC20E
(Cannot be used in conjunction with PLC link, EtherNet/IP™, and PROFINET)
• Supports cyclic communication (process data object communication) (Input: max. 530 bytes / Output: max. 534 bytes)
• Supports non-cyclic communication (mailbox communication)
• Supports CoE
• Conforms to conformance test V2.2.1.0

SNTP

Automatic date and time correction when connected to SNTP server

USB HDD

Various data output, including image data, when connecting an HDD (2 TB max.) to dedicated USB port
(USB 3.0 support, bus-powered, rated output: 900 mA)

Simple monitor output

Analog RGB output, XGA (1024 × 768 (24-bit color, 60 Hz))

Minimum display unit

0.01 μm, 0.0001°, 0.0001 mm2

Display language (Simple monitor output)

Switchable between English, Japanese, Simplified Chinese, Traditional Chinese, Korean, Thai, German, French, Italian,
Spanish (Mexico), Czech, Hungarian, and Polish

Ratings

Power voltage

24 VDC ±10%

Current consumption

3.5 A

Environmental resistance

Ambient temperature

0 to +45°C 32 to 113°F (when installed on a DIN rail) / 0 to +40°C 32 to 104°F (when installed on a surface)

Relative humidity

35 to 85% RH (No condensation)

Weight

Approx. 1600 g 3.53 lb

*1 Up to 7 master comparison tools (area/contour), 19 pitch measurement tools (distance/angle), 13 foreign particle distance tools (rotating rectangle), 8 foreign particle distance tools (circle/arc), and 7 profile extraction tools (depending on SD card capacity and settings).
*2 Positive common connection for NPN input devices and negative common connection for PNP input devices supported.

keyence Stock Image
Keyence OP-87928 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87606 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87606

Type

Mounting brackets

Applicable product

IL-2000

Material

SUS304

Weight

Approx. 338 g

keyence Stock Image
Keyence OP-87663 Keyence
Sale price $442.89
Only 1 unit left

Specifications

Model

OP-87663

Applicable product

IL Series

Number included

1 cable

Cable end

M8 L-shaped type - e-con

Length

20 m 65.62'

Note

If you cut the cable, you will require a connector (OP-84338) for connecting to the display unit (amplifier unit).

Weight

Approx. 680 g

keyence Stock Image
Keyence OP-87662 Keyence
Sale price $375.00
Only 1 unit left

Specifications

Model

OP-87662

Applicable product

IL Series

Number included

1 cable

Cable end

M8 L-shaped type - e-con

Length

10 m 32.81'

Note

If you cut the cable, you will require a connector (OP-84338) for connecting to the display unit (amplifier unit).

Weight

Approx. 360 g

keyence Stock Image
Keyence OP-87661 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87661

Applicable product

IL Series

Number included

1 cable

Cable end

M8 L-shaped type - e-con

Length

5 m 16.40'

Note

If you cut the cable, you will require a connector (OP-84338) for connecting to the display unit (amplifier unit).

Weight

Approx. 190 g

keyence Stock Image
Keyence OP-87660 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87660

Applicable product

IL Series

Number included

1 cable

Cable end

M8 L-shaped type - e-con

Length

2 m 6.56'

Note

If you cut the cable, you will require a connector (OP-84338) for connecting to the display unit (amplifier unit).

Weight

Approx. 80 g

keyence Stock Image
Keyence IL-S600 Keyence
Sale price$0.00
Sold Out

Specifications

Model

IL-S600*1

Mounting distance

600 mm

Measurement range

200 to 1000 mm

Light source

Amplifier type

Red semiconductor laser; wavelength 655 nm
(visible light)

Laser Class

Class 2 Laser Product
(FDA (CDRH) Part1040.10*2, IEC 60825-1): 2014

Output

560 μW

Spot diameter

Approx. 600 × 7500 μm (at the reference distance)

Linearity

±0.1% of F.S. (When used under 200 to 600 mm)
±0.3% of F.S. (When used under 200 to 1000 mm)
*3*4

Repeatability

50 μm*5

Sampling rate

0.33/1/2/5 ms (Variable to 4 levels)

Operating indicators

Laser emission warning indicator: green LED,
Analog range indicator: orange LED,
Reference distance indicator: red/green LED

Temperature characteristic

0.02% of F.S./°C*4

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp: 10000 lx*6

Ambient temperature

-10 to +50°C (No condensation and freezing)

Relative humidity

35 to 85% RH (No condensation)

Pollution degree

3

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude,
2 hours each for X, Y, and Z axes

Material

Housing material: PBT, Metal: SUS304,
Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 135 g

*1 Amplifiers purchased before August 16th, 2011 cannot be used.
*2 The classification is implemented based on IEC60825-1 following the requirement of Laser Notice of FDA (CDRH).
*3 Value when measuring the KEYENCE standard target (white diffuse object).
*4 The F.S. is as shown to the right. IL-S600: ±400 mm
*5 Is the value for when our standard object (white diffuse object) is measured at an average of 128 times and with a sampling rate of 2 ms from a standard distance
*6 Value when the sampling rate is set to 2 ms or 5 ms.

keyence Stock Image
Keyence IL-S300 Keyence
Sale price$0.00
Sold Out

Specifications

Model

IL-S300*1

Mounting distance

300 mm

Measurement range

160 to 450 mm

Light source

Amplifier type

Red semiconductor laser; wavelength 655 nm
(visible light)

Laser Class

Class 2 Laser Product
(FDA (CDRH) Part1040.10*2, IEC 60825-1): 2014

Output

560 μW

Spot diameter

Approx. 300 × 5000 μm (at the reference distance)

Linearity

±0.05% of F.S. (When used under 160 to 300 mm)
±0.125% of F.S. (When used under 160 to 440 mm)
*3*4

Repeatability

30 μm*5

Sampling rate

0.33/1/2/5 ms (Variable to 4 levels)

Operating indicators

Laser emission warning indicator: green LED,
Analog range indicator: orange LED,
Reference distance indicator: red/green LED

Temperature characteristic

0.02% of F.S./°C*4

Environmental resistance

Enclosure rating

IP67

Ambient light

Incandescent lamp: 10000 lx*6

Ambient temperature

-10 to +50°C (No condensation and freezing)

Relative humidity

35 to 85% RH (No condensation)

Pollution degree

3

Vibration resistance

10 to 55 Hz, 1.5 mm double amplitude,
2 hours each for X, Y, and Z axes

Material

Housing material: PBT, Metal: SUS304,
Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 135 g

*1 Amplifiers purchased before August 16th, 2011 cannot be used.
*2 The classification is implemented based on IEC60825-1 following the requirement of Laser Notice of FDA (CDRH).
*3 Value when measuring the KEYENCE standard target (white diffuse object).
*4 The F.S. is as shown to the right. IL-S300: ±140 mm
*5 Is the value for when our standard object (white diffuse object) is measured at an average of 128 times and with a sampling rate of 2 ms from a standard distance.
*6 Value when the sampling rate is set to 2 ms or 5 ms.

Keyence Stock Image
Keyence IL-1550 Keyence
Sale price $1,774.05
Only 6 units left

Specifications

Model

IL-1550

Type

Panel mount

Main unit/Expansion unit

Expansion unit

Head compatibility

Compatible

Display

Minimum
displayable unit

IL-030: 1 µm, IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm, IL-2000: 100 µm

Display range

IL-030/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable),
IL-2000: ±9999.9 mm to ±9999 mm (2 levels selectable)

Display rate

Approx. 10 times/sec.

Analog voltage output

None

Analog current output

Control input

Bank switch input

Non-voltage input*1

Zero-shift input

Stop emission input

Timing input

Reset input

Control output

Judgement output

Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*2

Alarm output

Open collector output (NPN, PNP changeover possible/N.C.)*2

Current

Power voltage

Supplied by main unit*3

Power consumption

2200 mW or less (at 30 V: 74 mA or less)

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC

Weight

Approx. 160 g (including attachments)

*1 Assign an input of your choice to the 4 external input lines before using.
*2 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit)
The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit)
*3 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.

Keyence New Stock Image
Keyence IL-1500 Keyence
Sale price $908.91
In stock, 16 units

Specifications

Model

IL-1500

Type

Panel mount

Main unit/Expansion unit

Main unit

Head compatibility

Compatible

Display

Minimum
displayable unit

IL-030: 1 µm, IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm, IL-2000: 100 µm

Display range

IL-030/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable),
IL-2000: ±9999.9 mm to ±9999 mm (2 levels selectable)

Display rate

Approx. 10 times/sec.

Analog voltage output

±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω*1

Analog current output

4 to 20 mA Maximum load resistance of 350 Ω*1

Control input

Bank switch input

Non-voltage input*2

Zero-shift input

Stop emission input

Timing input

Reset input

Control output

Judgement output

Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*3

Alarm output

Open collector output (NPN, PNP changeover possible/N.C.)*3

Current

Power voltage

10 to 30 VDC ripple (P-P) 10% included, Class 2*4

Power consumption

2500 mW or less (at 30 V: 84 mA or less)

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC

Weight

Approx. 170 g (including attachments)

*1 Select and use one of ±5 V, 1 to 5 V, 0 to 5 V or 4 to 20 mA.
*2 Assign an input of your choice to the 4 external input lines before using.
*3 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit)
The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit)
*4 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.

Keyence New Stock Image
Keyence IL-1050 Keyence
Sale price $378.14
In stock, 13 units

Specifications

Model

IL-1050

Type

DIN-rail mount

Main unit/Expansion unit

Expansion unit

Head compatibility

Compatible

Display

Minimum
displayable unit

IL-030: 1 µm, IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm, IL-2000: 100 µm

Display range

IL-030/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable),
IL-2000: ±9999.9 mm to ±9999 mm (2 levels selectable)

Display rate

Approx. 10 times/sec.

Analog voltage output

None

Analog current output

Control input

Bank switch input

Non-voltage input*1

Zero-shift input

Stop emission input

Timing input

Reset input

Control output

Judgement output

Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*2

Alarm output

Open collector output (NPN, PNP changeover possible/N.C.)*2

Current

Power voltage

Supplied by main unit*3

Power consumption

2000 mW or less (at 30 V: 67 mA or less)

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC

Weight

Approx. 140 g (including attachments)

*1 Assign an input of your choice to the 4 external input lines before using.
*2 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit)
The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit)
*3 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.

Keyence New Stock Image
Keyence IL-1000 Keyence
Sale price $378.14
In stock, 14 units

Specifications

Model

IL-1000

Type

DIN-rail mount

Main unit/Expansion unit

Main unit

Head compatibility

Compatible

Display

Minimum
displayable unit

IL-030: 1 µm, IL-065/IL-100: 2 µm, IL-300: 10 µm, IL-600: 50 µm, IL-2000: 100 µm

Display range

IL-030/IL-065/IL-100: ±99.999 mm to ±99 mm (4 levels selectable),
IL-300/IL-600: ±999.99 mm to ±999 mm (3 levels selectable),
IL-2000: ±9999.9 mm to ±9999 mm (2 levels selectable)

Display rate

Approx. 10 times/sec.

Analog voltage output

±5 V, 1 to 5 V, 0 to 5 V Output impedance 100 Ω*1

Analog current output

4 to 20 mA Maximum load resistance of 350 Ω*1

Control input

Bank switch input

Non-voltage input*2

Zero-shift input

Stop emission input

Timing input

Reset input

Control output

Judgement output

Open collector output (NPN, PNP changeover possible/N.O., N.C. changeover possible)*3

Alarm output

Open collector output (NPN, PNP changeover possible/N.C.)*3

Current

Power voltage

10 to 30 VDC ripple (P-P) 10% included, Class 2*4

Power consumption

2300 mW or less (at 30 V: 77 mA or less)

Environmental resistance

Pollution degree

2

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Case / Front sheet: Polycarbonate; Key tops: Polyacetel; Cable: PVC

Weight

Approx. 150 g (including attachments)

*1 Select and use one of ±5 V, 1 to 5 V, 0 to 5 V or 4 to 20 mA.
*2 Assign an input of your choice to the 4 external input lines before using.
*3 The NPN open collector rated output is: 50 mA max./ch (20 mA when adding an expansion unit) less than 30 V, residual voltage less than 1 V (less than 1.5 V when adding over 6 units including the main unit)
The PNP open collector rated output is: 50 mA max./ch (20 mA/ch when adding expansion units), less than power voltage, and less than 2 V residual voltage (less than 2.5 V when adding over 6 units including the main unit)
*4 If there are over 6 additional expansion units, please use a power voltage of 20 to 30 V.

Keyence New Stock Image
Keyence IL-S100 Keyence
Sale price $676.10
In stock, 18 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence IL-300 Keyence
Sale price $691.77
In stock, 19 units

Specifications

Model

IL-300

Reference distance

300 mm 11.81"

Measurement range

160 to 450 mm 6.30" to 17.72"

Light source

Type

Red semiconductor laser, wavelength: 655 nm (visible light)

Laser class

Class 2 (FDA (CDRH) Part1040.10)*1
Class 2 (IEC 60825-1)

Output

560 µW

Spot diameter (at standard distance)

Approx. ø0.5 mm ø0.02"

Linearity

±0.25% of F.S. (160 to 440 mm 6.30" to 17.32")*2*3

Repeatability

30 µm*4

Sampling rate

0.33/1/2/5 ms (4 levels available)

Operation status indicators

Laser emission warning indicator: Green LED, Analog range indicator: Orange LED, Reference distance indicator: Red/Green LED

Temperature characteristics

0.08% of F.S./°C*5

Environmental resistance

Enclosure rating

IP67

Pollution degree

3

Ambient light

Incandescent lamp: 5,000 lux*6

Ambient temperature

-10 to +50 °C 14 to 122 °F (No condensation or freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Housing material: PBT, Metal parts: SUS304, Packing: NBR, Lens cover: Glass, Cable: PVC

Weight

Approx. 135 g

*1 The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.
*2 Value when measuring the KEYENCE standard target (white diffuse object).
*3 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75" IL-2000: +1000 to -1500 mm 39.37" to -59.05"
*4 Value when measuring the KEYENCE standard target (white diffuse object) at the reference distance, sampling rate: 1 ms, and average number of times: 128. For the IL-300/IL-600, the sampling rate is 2 ms. For the IL-2000, the sampling rate is set to 5ms.
*5 F.S. of each model is as follows. IL-030: ±5 mm ±0.20" IL-065: ±10 mm ±0.39" IL-100: ±20 mm ±0.79" IL-300: ±140 mm ±5.51" IL-600: ±400 mm ±15.75"
*6 Value when the sampling rate is set to 2 ms or 5 ms.

Recently viewed