Machine Vision Systems

5768 products

Showing 5569 - 5592 of 5768 products

Showing 5569 - 5592 of 5768 products
View
Keyence Stock Image
Keyence OP-42382 Keyence
Sale price$0.00
Sold Out
Buy the Keyence OP-42382 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence OP-42382 is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence New Stock Image
Keyence TH-315 Keyence
Sale price $495.00
Only 5 units left

Specifications

Model

TH-315

Type

Detecting minute metallic objects

Minimum detectable object

0.3 mm dia.
x 0.75 mm
0.01" dia. x 0.03"
steel wire*1

Detecting area

15 mm
0.59" dia.

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 170 g

*1 Data obtained with the amplifi er set at maximum sensitivity when target was travelling at 500 mm 19.69".

Keyence Stock Image
Keyence KV-E16R Keyence
Sale price $639.44
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence Stock Image
Keyence LV-21P Keyence
Sale price $576.21
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence PH-114 Keyence
Sale price $739.89
Only 4 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence TA-340 Keyence
Sale price $772.50
Only 7 units left

Specifications

Model

TA-340

Sensitivity adjustment

Sensitivity selector switch and fi ne-adjustment trimmer

Output

Control output
(One shot)

Solid-state
(NPN)

100 mA (40 V max.)*1

Relay contact

SPDT 250 VAC 2 A*2

Control output

1 ms

10 ms

OFF-delay time

65 ms (contact output only)

Rating

Power voltage

100/200 VAC ±10 %, 50/60 Hz

Power consumption

5 VA max.

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Accessories

Plastic screwdriver

Weight

Approx. 330 g

*1 Both the solid-state and contact outputs of the amplifi er are one-shot signals; the signals turn on as the object enters the sensor head. NPN output can easily be converted to PNP output by connecting the optional OP-5148 PNP Output Converter.
*2 Both the solid-state and contact outputs of the amplifi er are one-shot signals; the signals turn on as the object enters the sensor head.

keyence Stock Image
Keyence SV2-BE20G Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV2-BE20G

Type

Encoder cable, Hi-flex robotic cable with battery

Length

20 m 65.6'

Note

for 50 to 750 W motor

keyence Stock Image
Keyence OP-84350 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84350

Type

L-shaped Mounting Bracket

Applicable product

LV-S62

Material

SUS304, SUS(Screw)

Note

Screw (SUS) attached. Optional.

keyence Stock Image
Keyence SV2-M005AS Keyence
Sale price $1,085.10
Only 6 units left

Specifications

Model

SV2-M005AS

General specifications

Applicable servo amplifier

SV2-005L2

Rated output

50 W

Rated torque

0.159 N·m *1

Instant maximum torque

0.557 N·m

Rated current

0.55 Arms

Instant maximum current

2.0 Arms

Rated rotation speed

3000min-1

High rotation speed

6000 min-1

Torque constant

0.316 N·m/Arms

Rotor moment of inertia

0.0395 ×10-4kg·m2

Rated power rating

6.40 kW/s

Rated angle acceleration

40200 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

22 bits

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20 to 80% RH (no condensation)

Operating atmosphere

Indoors (no corrosive gas, flammable gas, oil mist, or dust)

Altitude

2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: phase A, CE: phase B

Min. insulation resistance

500 VDC, 10 MΩ or more with insulation resistance tester

Isolation voltage tolerance

1500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part15 B, ICES-003. Class A

Allowable load inertia moment

35 ×

Approx. weight

0.3 kg

*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

keyence Stock Image
Keyence AP-N10D Keyence
Sale price$0.00
Sold Out

Specifications

Model

AP-N10D

Type

Dual output type

Applicable sensor head

AP-41M, AP-41, AP-43, AP-44, AP-48

Configuration/Display range

-15 to +110 % of F.S.

Repeatability

±0.2 % of F.S.

Display resolution

AP-41M/41/44/48: Standard mode 0.1 kPa, High resolution mode 0.01 kPa
AP-43: Standard mode 0.001 MPa, High resolution mode 0.1 kPa

Power consumption

Normal

770 mW or less (at 24 V, 32 mA or less/at 12 V, 54 mA or less)

Eco mode

560 mW or less (at 24 V, 23 mA or less/at 12 V, 37 mA or less)

Expansion units

Max. 16 units (Dual output type is counted as 2 units.)*1

Control output(s)

2*2

Display temperature characteristic

±1 % of F.S. (When the temperature varies from 25 °C 77 °F)

Response time (Chattering prevention function)

1 ms/2.5 ms/5 ms/100 ms/500 ms/1,000 ms/5,000 ms selectable

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % max. Class2

Environmental resistance

Ambient temperature

0 to +50 °C 32 to 122 °F (No freezing)*3

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Material

Main unit and cover: Polycarbonate

Weight

Approx. 20 g

*1 Can connect to other N-bus sensor amplifiers. N-bus represents the wire-saving system for KEYENCE-manufactured sensor amplifiers.
*2 Number of outputs when connected to the communication unit NU Series. There are no control output wires.
*3 11 to 16 units connected: 0 to +45 °C 32 to 113 °F (When the sensor amplifier is installed on DIN rail on a metal plate)

keyence Stock Image
Keyence WM-SG Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SJ-L005MT Keyence
Sale price $2,287.90
Only 5 units left

Specifications

Model

SJ-L005MT

Type

Tube type

Voltage application method

High frequency AC method (68 kHz)

Applied voltage

2.5 kVAC

Ion balance

±10 V*1

Static elimination time

See Data Sheet.

Air supply pressure

0.05 to 0.5 MPa

Air supply temperature

0 to +50°C 32 to 122°F

Connection tube

Outer diameter: ø6 0.24", inner diameter: ø4 0.16"

Ozone concentration

0.05 ppm or less*2

Control input

Static elimination stop input

Switchable between non-voltage input and voltage input
Non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA or lower (short circuit)
Voltage input: Maximum input rating 30 V, ON voltage 7 V or higher, OFF current 0.1 mA or lower, ON current 1.5 mA or lower (at 30 V)*3

Reset input

LPC mode input

Control output

Alarm (N.C.)/Ion level alarm (N.O.)

Open-collector output 30 VDC or less
50 mA max., residual voltage 1.5 V or less
NPN/PNP settings switchable*3*4

Ratings

Power voltage

24 VDC ±10% (including ripple) or
12 VDC (dedicated AC adapter OP-88020/87722*5)

Current consumption

0.2 A or less (24 VDC)
0.3 A or less (12 VDC)

Environmental resistance

Ambient temperature

0 to +50°C 32 to 122°F (0 to +40°C 32 to 104°F when OP-87722 is used)

Relative humidity

35 to 65% RH (no condensation)

Overvoltage category

I

Pollution degree

2

Material

Main unit case: PBT / Charge indicator: TPU / Securing bracket: SUS303, PBT
Cable: PVC, TPE, copper alloy
Connector: PBT, brass + gold plating, phosphor bronze + gold plating, coper alloy + gold plating
Fitting: Brass + electroless Ni plating, POM, NBR

Weight

Approx. 65 g

*1 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 50 mm 1.97", and air supply pressure of 0.2 MPa (typical values)
*2 Measurement results taken with tube length of 500 mm 19.69", an installation distance of 300 mm 11.81", and air supply pressure of 0.1 MPa (typical values)
*3 Cannot be used when the power supply is the AC adapter.
*4 To use the ion level alarm with the tube type, use it with air supply pressure of 0.3 MPa or less.
*5 Rated input of 100 to 240 VAC, 50/60 Hz

keyence Stock Image
Keyence IV4-G500MA Keyence
Sale price $6,733.65
Only 3 units left

Specifications

Model

IV4-G500MA

Type

Standard model
[IV4-G500MA+OP-88909] Ultra-narrow field of view model

Installed distance

From 50 mm 1.97"
[IV4-G500MA+OP-88909] 23 mm to 40 mm 0.91" to 1.57"

Field of view

Installation distance of 50 mm 1.97": 22 (H) × 16 (V) mm to
Installation distance of 3000 mm: 118.11" 1184 (H) × 888 (V) mm
(reference value)
[IV4-G500MA+OP-88909]
Installation distance of 23 mm 0.91": 9.8 (H) × 7.3 (V) mm to
Installation distance of 40 mm 1.57": 15 (H) × 11.2 (V) mm
(reference value)

Image receiving element

Type

1/2.9 inch monochrome CMOS

Number of pixels

1280 (H) × 960 (V)

Focus adjustment

Auto *1

Exposure time

12 μs to 9 ms *2 *3

Lights

Illumination

Infrared LED

Lighting method

Pulse lighting

Indicators

2 indicators (both displaying same content)

Power supply

Average power consumption

2.5 W (without AI imaging illumination unit installed)
6.6 W (with AI imaging illumination unit installed)
[IV4-G500MA+OP-88909] 2.5 W

Environmental resistance

Enclosure rating

IP67 *4
[IV4-G500MA+OP-88909] ─

Ambient temperature

0 to +50°C 32 to +122°F (no freezing) *5

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Frequency: 10 to 500 Hz;
Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 3 times in each of 6 directions

Material

Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *6

Weight

Approx. 75 g 2.65 oz (no AI imaging illumination unit)
Approx. 225 g 7.94 oz (with AI imaging illumination unit)
[IV4-G500MA+OP-88909] Approx. 85 g 3.00 oz

*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program.
*2 With an AI imaging illumination unit installed, exposure time is up to 6.25 ms.
*3 Maximum exposure time is 500 ms only when lighting is set to OFF.
*4 Except when polarizing filters (OP-88642/OP-88643/OP-88646/OP-88647) are installed.
*5 When the operating ambient temperature exceeds 40°C 104°F, install in accordance with KEYENCE instructions, taking appropriate measures for heat dissipation to ensure that the case temperature does not exceed the rated 65°C 149°F. For the case temperature, measure the side with the “IV4 series” label.
*6 ESD safe and IEC61340-5-1 compliant.

Keyence Stock Image
Keyence SZ-01SSAFETY Keyence
Sale price $4,122.98
Only 3 units left
Buy the Keyence SZ-01SSAFETY - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence SZ-01SSAFETY is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence New Stock Image
Keyence FD-XS8E Keyence
Sale price $1,157.65
Only 7 units left

Specifications

Model

FD-XS8E

Supported pipe materials

Metal pipes, Plastic pipes (soft/hard) *1

Supported fluids

Liquids (water, oil, adhesive, grease, chemical solutions, etc.) *1

Supported fluid temperature

0 °C (no freezing on the pipe surface) to 100 °C 32 to 212 °F (Pipe surface temperature)

Clamp set model

Plastic pipe/tube attachment

FD-XC8R1, FD-XC8R2, FD-XC8R3

Metal pipe attachment

FD-XC8M*2

Maximum rated flow rate

Outer diameter of pipe ø 6 0.24 ", 1/4 " (6.35 mm) : 3000 mL/min
Outer diameter of pipe ø 8 0.31 ": 8000 mL/min

Zero cut flow rate

50 mL/min*3 (variable, default)

Display resolution

Instantaneous flow rate

1/10 mL/min (Displayed on controller)

Repeatability

Response time 50 ms: ±20 % of RD
Response time 500 ms: ±15 % of RD

Hysteresis

Variable

Display method

Status indicator

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529) , IP68G (JIS C0920) *4

Ambient temperature

-10 to 60 °C 14 to 140 °F (No freezing)

Relative humidity

35 % to 85 %RH (No condensation)

Vibration resistance

10 to 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

Shock resistance

50 G 11 ms 3 times each for X,Y,Z direction

Material

Sensor head

Head body: PPS/PPSU, relay amplifier: PPS, cable: PVC, controller connector: PPS/PBT/POM

Clamp set

For plastic pipe

Body, fixing screw: PPS, detection surface: special rubber, pipe support rubber: FKM, sensor head fixing screw: SUSXM7

For metal pipe

Metal: SUS304/SUSXM7, detection surface: special rubber, clamp support rubber: FKM, sensor head fixing screw: SUSXM7

Weight

Approx. 250 g

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Readings may become unstable depending on the type of pipe.
*2 When using stainless steel or iron pipes, the ideal pipe wall thickness is as follows, FD-XS1E: approx. 0.5 mm 0.02", FD-XS8E: approx. 1 mm 0.04", FD-XS20E: approx. 1 0.04" to 2 mm 0.08". FD-X signal strength and stability will decrease as the thickness of the pipe wall increases or decreases from the suggested size.
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 The connector part of the sensor head cable is IP65/IP67.

keyence Stock Image
Keyence CA-DWC30 Keyence
Sale price$0.00
Sold Out

Specifications

Model

CA-DWC30

Peak wavelength after conversion

615 nm 0.024 Mil

Conversion efficiency

Approx. 80 to 90 %*1

Sheet size

A4 (210 × 297 mm 8.27" × 11.69"), thickness: 0.2 mm 0.01"*2

Sheet composition

(1) Laminate: Polyester film (transparent, sand mat treatment)
(2) Special wavelength converting material
(3) Foamed polyester film (white)
(4) Highly adhesive, re-peelable type*3
(5) Release liner with graduated grid

Weight

Approx. 20 g (including the peelable sheet)

*1 This is the value only for the special wavelength converting material.
*2 The wavelength converting material is applied on the entire A4-sized surface with no margins.
*3 Adhesive strength: 9.4 N/25 mm 0.98" 30 minutes after application, 10.8 N/25 mm 0.98" 24 hours after application

keyence Stock Image
Keyence FD-XA5 Keyence
Sale price $1,269.56
Only 6 units left

Specifications

Model

FD-XA5

Type

Panel type, main unit

Display method

Output indicator, 4-digit 7 segment display, OLED, Stability level display

Display refresh frequency

Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second

Response time

50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms)

Integration data storage interval

Written to the memory every 10 seconds

Memory back up

EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more) *1

Detection mode

ch.1

Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable)

ch.2

Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable)

Input/output

Output

NPN/PNP setting switch
Open collector output: 30 V or lower, main unit: 50 mA or lower/ch.*2/expansion unit: 20 mA or lower/ch., residual voltage: 2 V or lower

Analog output

4-20 mA/0-20 mA (selectable) load resistance: 500 ohms or lower

External input

Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable)
Short circuit current: NPN 1 mA or lower/PNP 2 mA or lower, input time: 20 ms or longer

Network support

IO-Link*3

Unit expansion

-

Protection circuit

Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection

Power supply

Power voltage

20 to 30 VDC including 10 % ripple (P-P) , Class 2

Power consumption

195 mA or lower (including the sensor head, excluding the load current)

Environmental resistance

Ambient temperature

-10 to +50 °C (No freezing) 14 to 122 °F

Relative humidity

35 % to 85 %RH (No condensation)

Vibration resistance

10 - 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

Shock resistance

100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction

Material

Main body case/front sheet: PC, Key top: POM, Cable: PVC

Weight

Approx. 210 g

*1 Internal data from full time recording can be read via USB (Ver.2.0) communication.
*2 20 mA or lower/ch when adding expansion units.
*3 IO-Link: Specification v1.1/COM2 (38.4 kbps) is supported. If the end of the cable needs to be an M12 connector when supporting IO-Link communication, connect an M12 conversion connector (OP-88296) to the cable.

keyence Stock Image
Keyence OP-88715 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence PX-H72G Keyence
Sale price $679.89
Only 5 units left

Specifications

Model

PX-H72G*1

Type

M12 Thrubeam Armored

Light source LED

Infrared LED
(Wavelength:870 nm)

Detecting distance

TURBO

10 m 32.8'

SUPER

15 m 49.2'

ULTRA

30 m 98.4'

MEGA

40 m 131.2'

Detectable object

ø7.5 mm ø0.30"
Opaque materials

Spot diameter

Environmental resistance

Enclosure rating

IEC: IP68/JEM: IP68g/NEMA: 4X, 6P, 13/DIN: IP69K

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Case material

Housing :SUS303 (Plastic parts:PMP, POM) Lens :BK7

Accessories

Screw nut (SUS303) x 4, toothed washer (SUS304) x 2

Weight

Approx. 260 g (Including cable)

*1 The PX-H72 is available with a 30 m 98.4' cable for the transmitter and 10 m 32.8' cable for the receiver.

Keyence Stock Image
Keyence KV-XH16ML Keyence
Sale price $732.45
Only 9 units left

Specifications

Model

KV-XH16ML

Type

Positioning/motion unit

No. of control axes

16 axes (total including virtual axes)

Appropriated device

Relay: 2112 points (132 channels)
Data memory: 4 words

Output format

MECHATROLINK-III

Connectable CPU unit

KV-X Series/KV-8000A

Max. number of connectable units

7

Refresh

Automatic refresh, direct refresh, synchronous refresh between units

Control mode

Positioning control, Torque control, Speed control, ML-III command, I/O control

Control period

62.5 μs or more (With SV2 Series: 125 μs or more)

Starting time

125 μs

Axis control function execution method

Ladder program, unit program (flow, C language)

Unit program capacity

3 MB (Max. number of blocks: 20000)

Flow

Block type

Positioning control block, synchronization control block, speed control block, torque control block, origin return block, current coordinate change block, speed change block, target coordinate change block, continuous positioning start block, “continuous-point number block” continuous–independent/linear interpolation block, continuous–arc interpolation block, continuous positioning complete standby block, calculation block, standby block, program execute block, program stop/restart block, force close program block, unit interrupt block, cam data read/write block, selection branch block, parallel branch block, merge block, GOTO block, start block, end block

flow

Max. number of flows

256

Number of simultaneous activities

No upper limit

Flow

Internal data Memory

524288 words

Position unit

mm, inch, deg (angle), PLS (number of pulses) Decimal point position from 0 to 9 digits, unit conversion function available

Cumulative address

-2147483648 to +2147483647 specification units

Positioning control

Positioning mode

Absolute value/relative value

Position setting range

-2147483648 to +2147483647 specification units

Interpolation

Linear interpolation, arc interpolation, helical interpolation

Single operation address

-2147483648 to +2147483647 specification units

Acceleration/deceleration curve

Linear, SIN

Acceleration/deceleration time

0 to 65535 ms

M-code

1 to 65000, WITH/AFTER mode

Sensor positioning

External input-based switching control from speed to position

Number of points

100 points/axis (Trajectory control at 100 points or more possible with flows)

Special function

Synchronous tracking control, absolute position tracking control

Synchronization control

Input

External reference, instruction coordinates, current coordinates

Input filter

Interference prevention function

Clutch

Select from direct, slide, and follow-up

Cam

Resolution: 2048 to 32768 Data points: 4 to 64 (changes according to the resolution)

Compensation during operation

Compensation via auxiliary input, phase compensation, and step angle compensation

Origin return

Origin return method

Data set type, dog type (push),
dog type (selectable from “with Z phase” or “without Z phase”),
dog type sizing (selectable from “with Z phase” or “without Z phase”),
immediate Z phase, origin sensor and Z phase,
rising edge of limit switch,
origin sensor midpoint/rising edge

JOG/inching

JOG (high speed/low speed), inching (specifiable pulses)

Teaching

Current coordinate teaching

Memory data

Point parameters (each axis), synchronization parameters (each axis), cam data, unit program, servo parameters, setting read/write during RUN (with some restrictions)

Output display

LINK, CONNECT, error status

Self-diagnosis function

Diagnosis can be made through hardware errors, various parameter errors, error numbers, and error messages

Parameter setting

Parameters can be set from KV STUDIO, ladder programs, and unit programs (flow)

Data backup

Coordinates: nonvolatile memory backup (unlimited) Parameter settings: flash ROM backup (20000 switches)

Internal current consumption

400 mA or less

Weight

Approx. 280 g

keyence Stock Image
Keyence MP-FR10 Keyence
Sale price $622.25
Only 2 units left

Specifications

Model

MP-FR10

Type

Single model

Connection bore diameter

Rc3/8" (10 A)

Supported gases

Air and non-corrosive gases

Supported gas temperature

-5 to +50°C, 23 to 122°F

Operating pressure range

0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1

Pressure resistance

1.5 MPa, 15 bar, 217.5 psi

Flow rate

Detection principle

Heat based (mass flow rate)

Rated flow range (normal)

2.0 to 1000.0 L/min
0.12 to 60.00 m3/h 4.24 to 2118.88 ft3/h 0.07 to 35.31 CFM

Zero cut flow rate

2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM

Measurement accuracy

±(1.5% of RD + 0.5% of F.S.) *2 *3

Repeatability

±1.0% of F.S. (with an averaging time of 1.0 s)

Display resolution

0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM

Response time

150 ms (63% response) *4

Averaging time

OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable)

Pressure (Digital value, gauge pressure)

Rated pressure range

0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi

Measurement accuracy

±2.0% of F.S.

Repeatability

±0.2% of F.S. (with a response time of 50 ms)

Display resolution

0.001 MPa, 0.01 bar, 0.1 psi

Response time

Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4

Humidity (Dew point)

Rated relative humidity range/ dew point range

15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6

Measurement accuracy

±4°C, ±7°F *5 *6

Display resolution

5%RH/1°C, 1°F *5 *6

Temperature

Measurement accuracy

±2.0°C, ±3.6°F *7

Display resolution

0.1°C, 0.1°F *7

Shut-off valve

Response time

1 s or less (closed → open)

Leakage amount

50 mL/min 0.002 CFM (N) or less

Filter/regulator (Standard model only)

Pressure adjustment range

Filtration degree

Drainage cup capacity

Check valve

Available

Display

Color LCD, status indicator

Data accumulation

Accumulation period

Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks

Data reading

USB 2.0/Ethernet

I/O

Control output (Ch.1/2/3/4/5)

NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less

Analog output (Ch.1/2)

4 to 20 mA, load resistance: 260 Ω or less *4

External input (Ch.2/3/6)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output

Power supply

Power voltage

24 VDC +25%/-20% (including ripple), Class 2 or LPS

Power consumption

1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current)

Communication interface

USB2.0

Network compatibility

When using only this unit: IO-Link (Specification v1.1/COM3) *9
When connecting MP-FEN1 : EtherNet/IP™, PROFINET, Modbus/TCP, MC protocol/SLMP

Environmental resistance

Enclosure rating

IP67 (IEC60529) *10

Ambient temperature

−5°C to +50°C 23°F to 122°F (no freezing) *11

Relative humidity

35%RH to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions

Shock resistance

300 m/s2, XYZ axes, 10 times for each axis

Material

Sensor part : PET/PPS/PBT/POM/aluminum/SPHC
Filter/regulator : Aluminum/POM/HDPE/NBR/Nylon *12

Weight

Approx. 550 g 19.40 oz

*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve.
*2 This value is guaranteed by KEYENCE inspection facilities while testing with air. Errors will be introduced by factors such as the gas type, gas temperature, and ambient temperature.
*3 Value in an environment with a constant temperature of 25°C 77°F and compressed air evaluated as purity class 1*1 (ISO 8573-1 (2010)/JIS B 8392-1 (2012)).±(5.5% of RD + 0.5% of F.S.) when equivalent to purity class 3*4.
*4 15 ms is added to the analog output response time.
*5 Measurable when at least 2% of F.S. worth of gas is flowing.
*6 The prescribed accuracy may not be met or the unit may be damaged if the compressed air contains a large amount of oil mist, organic solvent, or other gas. (For details, see “Gas Being Measured” on page 4.)
*7 When the flow is 5% of F.S. or higher. Errors due to heat generated by the main unit occur when the flow is too small.
*8 When connecting MP-FEA1 and/or MP-FEN1, add each device’s current consumption (2.1 A or less including load current).
*9 Use an IO-Link master that can supply 1.2 A or more. (1.6 A or less when connecting an MP-FEA1 and an MP-FEN1.) IO-Link is a registered trademark or trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 When protection is provided to prevent dust and liquid from intruding through the exhaust port. The IP67 enclosure rating is lost when a USB connection is established.
*11 If this product is used with a power supply voltage of 26.4 V or more, the upper limit on the ambient temperature is 45°C 113°F.
*12 Nylon is only used on the MP-Fx20R.

Keyence Stock Image
Keyence OP-88439 Keyence
Sale price $418.35
Only 3 units left
Buy the Keyence OP-88439 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence OP-88439 is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence New Stock Image
Keyence OP-87901 Keyence
Sale price $165.95
Only 7 units left

Specifications

Model

OP-87901

Type

Polarised light filter attachment

Applicable product

IV-G600MA

Weight

Approx. 5 g

keyence Stock Image
Keyence CV-X102A Keyence
Sale price $6,580.35
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed