
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-86 |
|||
Heat resistant temperature |
105°C 221°F*1 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Object with a diameter of 0.005 mm0.0002"*2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +105 °C -40 to 221 °F |
||
Weight |
Approx. 22 g |
|||
*1 Use in a dry state. Also, when using the heat resistant type, make a selection with ample room for the ambient temperature. | ||||




Specifications
Model |
SJ-E036L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
440 mm 17.32"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
5 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
670 g 23.63oz |
|||
*1 Measured under the following conditions. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-85588 |
|||
Overview |
This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M8 connector sensor |
|||
Cable end |
M8 L-shaped connector - M12 straight |
|||
Length |
5 m 16.40' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 170 g |
|||

Specifications
Model |
GL-VM44LP |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
44 |
|||
Total length |
1760 mm 69.29" |
|||
Detection height |
1720 mm 67.72" |
|||
Protection height |
1805 mm 71.06" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
5.6 |
|
OFF→ON |
49.1 *3 |
|||
All blocked→ON |
56.8 *4 |
|||
With channel A or B |
ON→OFF |
16.4 |
||
OFF→ON |
66.9 *3 |
|||
All blocked→ON |
89.7 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
166 *5 |
||
Receiver |
181 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
56 *5 |
||
Receiver |
61 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1140 g 40.24 oz |
||
Receiver |
1160 g 40.94 oz |
|||
Total |
2300 g 81.19 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-E204L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
2120 mm 83.46"*3 |
|||
Total length |
2000 mm 78.74" |
|||
No. ofelectrodes |
33 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2100 g 74.08oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
FU-R67*1 |
|||
Type |
Threaded and Hex-Shaped Active Receiver Fibers |
|||
Size |
M6 |
|||
Fibre unit length |
2 m6.6'Free-cut |
|||
Fibre unit diameter |
ø 2.2ø 0.09" x 2 |
|||
Shape |
Threaded |
|||
Minimum bend radius |
R2 mmR0.08"ToughFlex |
|||
Environmental resistance |
Ambient temperature |
−40 to +60 ˚C -40 to +140 °F |
||
Weight |
Approx. 21 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||



Specifications
Model |
ER-GR18P |
|||
Type |
Environment-resistant all-metal shielded type Screw type M18 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
10 mm 0.39" ±10% *2 |
|||
Response frequency |
50 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
30 × 30 mm 1.18" × 1.18" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 100 mA or less for 1 output; |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP68G (JIS C 0920), IP69K (DIN40050) |
||
Ambient temperature |
-40 to +85°C -40°F to +185°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface and case: SUS316L, Nut: SUS316L, Toothed lock washer: SUS316L |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 110 g 3.88 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
GL-RP10P |
|||
Type |
Unit connection cable |
|||
Number included |
1 cable |
|||
Cable end |
Main unit plug (Black) - Loose wires |
|||
Length |
10 m 32.81' |
|||
Material |
Main unit connection connector: PBT, Cable: PVC |
|||
Note |
Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2) |
|||
Weight |
Approx. 400 g |
|||

Specifications
Model |
KV-B16RC |
|||
Type |
Output unit |
|||
External connection method |
Removable terminal block |
|||
Output |
Number of outputs |
16 points |
||
Output mode |
Relay |
|||
Rated load |
250 VAC/30 VDC, 2A (8 A/1 common) |
|||
Leakage current at OFF |
- |
|||
Residual voltage at ON | ||||
ON resistance |
50 mΩ or less |
|||
Common method |
8 points/1 common |
|||
Operation time |
OFF to ON/ON to OFF: 10 ms or less |
|||
Internal current consumption |
120 mA or less |
|||
Weight |
Approx. 190 g |
|||


Specifications
Model |
OP-87262 |
|||
Type |
Dedicated Stand for Mounting 12-inch LCD Monitor |
|||
Applicable product |
CA-MP120T, CA-MP120 |
|||

Specifications
Model |
FU-95HA |
|||
Type |
Liquid-level detection fiber unit |
|||
Detecting method |
Pipe mounting type |
|||
No. of beam axes |
1 mm0.039" |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Environmental resistance |
Ambient temperature |
-40 to +105 °C -40 to 221 °F*1 |
||
Accessories |
Binding band × 2, nonslip rubber × 2, spacer × 2, screw × 2, nut × 2, Fiber cutter × 1, Adaptor B × 1 |
|||
Weight |
Approx. 22 g |
|||
*1 When this product is used in an environment with a consistently high temperature, we recommend an ambient usage temperature of 90 °C 194 °F or less. | ||||




