Machine Vision Systems

5768 products

Showing 5161 - 5184 of 5768 products

Showing 5161 - 5184 of 5768 products
View
Keyence Stock Image
Keyence VT2-8TB Keyence
Sale price $1,774.80
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence FU-86 Keyence
Sale price $360.00
Only 2 units left

Specifications

Model

FU-86

Heat resistant temperature

105°C 221°F*1

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø2.2

Minimum bend radius

R25 mm0.984"

Minimum detectable object

Object with a diameter of 0.005 mm0.0002"*2

Environmental resistance

Ambient temperature

-40 to +105 °C -40 to 221 °F

Weight

Approx. 22 g

*1 Use in a dry state. Also, when using the heat resistant type, make a selection with ample room for the ambient temperature.
*2 The minimum detectable object is the value when the detecting distance and sensitivity have been set to their optimal state.

keyence Stock Image
Keyence SK-C3 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CV-022U Keyence
Sale price $403.53
Only 9 units left
Buy the Keyence CV-022U - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence CV-022U is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence Stock Image
Keyence XG-H500M Keyence
Sale price $427.50
Only 5 units left
Buy the Keyence XG-H500M Vision System Component - an industrial machine vision device for automated inspection, measurement, or identification. Features high-resolution imaging and industrial-grade design. The Keyence XG-H500M is a direct replacement for existing installations.
Keyence Stock Image
Keyence SJ-E036L Keyence
Sale price $1,123.29
Only 6 units left

Specifications

Model

SJ-E036L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

440 mm 17.32"*3

Total length

350 mm 13.78"

No. ofelectrodes

5

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40 °C 32 to 104 °F

Relative humidity

35 to 85 % RH (No condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

670 g 23.63oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

Keyence Stock Image
Keyence KV-40R Keyence
Sale price $1,084.49
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-85588 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-85588

Overview

This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance.

Applicable product

M8 connector sensor

Cable end

M8 L-shaped connector - M12 straight

Length

5 m 16.40'

Material

Cable: Polyurethane (PUR)

Weight

Approx. 170 g

keyence Stock Image
Keyence GL-VM44LP Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-VM44LP

Beam axis spacing/Lens diameter

40 mm 1.57": ø5 ø0.197"

Number of beam axes

44

Total length

1760 mm 69.29"

Detection height

1720 mm 67.72"

Protection height

1805 mm 71.06"

Minimum detectable object size

ø45 mm ø1.77" *1

Detecting distance

0.3 to 15 m 1.0' to 49.2' *2

Effective angular aperture

Up to ±2.5° (3 m 9.8' or above)

Light source

Infrared LED (850 nm)
Exempt Group (IEC62471)

Detection mode

ON when all beam axes received

Synchronization method

Optical synchronization

Interference prevention function

Interference prevention up to 2 units by series connection and switch setting

Control output (OSSD output)

Output type

Transistor output ×2 (PNP/NPN)

Maximum load current

150 mA or less

Residual voltage (when ON)

Up to 2.5 V (with 5 m 16.4' cable)

OFF voltage

Up to 2.0 V (with 5 m 16.4' cable)

Leakage current

Up to 0.8 mA

Maximum load capacity

0.8 μF

Load wiring resistance

Up to 2.5Ω

Protection circuit

Power supply reverse connection protection, short circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC/EN61496-1, UL61496-1

EMI

EN55011 Class A, FCC Part15B Class A, ICES-003 Class A

Safety

IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2/EN61496-2, UL61496-2 (Type 4 AOPD)
EN ISO13849-1 (Category 4, PL e)
IEC61508/EN61508 (SIL3)
UL60947-1 / CSA C22.2 No. 60947-1
UL1998

Response time (OSSD)

With channel 0

ON→OFF

5.6

OFF→ON

49.1 *3

All blocked→ON

56.8 *4

With channel A or B

ON→OFF

16.4

OFF→ON

66.9 *3

All blocked→ON

89.7 *4

Inputs

Short circuit current: Approx. 3 mA

Power supply

Power voltage

24 VDC -20/+25% 10% ripple (P-P) or less, class 2

Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control

Transmitter

166 *5

Receiver

181 *5

Current consumption (at maximum) (mA) Indicator : OFF

Transmitter

56 *5

Receiver

61 *5

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less

Operating ambient temperature

-30 to +55°C -22 to +131°F (no freezing) *6

Operating relative humidity

Up to 95%RH (no condensation)

Storage temperature

-30 to +70°C -22 to +158°F (no freezing)

Storage relative humidity

Up to 95% RH

Overvoltage category

ll

Vibration resistance

5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes

Shock resistance

15 G 6 ms pulses 100 times each in X, Y, and Z axes

Material

Main unit case

Aluminum alloy

Upper case/lower case

PPS (GF40%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

1140 g 40.24 oz

Receiver

1160 g 40.94 oz

Total

2300 g 81.19 oz

*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s.
*2 When the optional front protection cover is attached to either the transmitter or receiver, the detecting distance is shortened by 0.5 m 1.6'. When attached to both, it is shortened by 1 m 3.3'.
*3 If light blocking time is 80 ms or less, the response time (OFF>ON) will be slowed down to a minimum of 80 ms to ensure that the OSSD remains OFF for 80 ms or more.
*4 “All blocked > ON” is the time it takes for the transmitter and receiver to turn ON from an unsynchronized state (both upper and lower end beam axes are blocked).
Since the reception or blockage of light is determined after the transmitter and receiver are synchronized, the response time is long.
*5 The current of control output (OSSD) is not included.
*6 When the ambient operating temperature is between 50 and 55°C 122°F and 131°F, set the indicator mode to Light OFF mode.

Keyence Stock Image
Keyence CV-S035MH Keyence
Sale price $577.49
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence SJ-E204L Keyence
Sale price$0.00
Sold Out

Specifications

Model

SJ-E204L

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method / Applied voltage

Pulse AC method/±8000 V

Ion balance control method

Hi-Power I.C.C. method

Ion balance

±30 V*1

Installation distance

50 to 2000 mm 1.97" to 78.74"

Control input

Static elimination stop input

NPN open collector or contact point signal without voltage

Control output

Ion level warning, condition warning, alarm output

NPN open collector, Maximum 100 mA (40 VDC or less)

Condition alarm output

Alarm output

Communication function

Remote control communication

Major functions

Condition alarm, ion level alarm, alarm output

Air connection port

Rc 1/8

Air supply pressure

0.1 MPa to 0.5 MPa*2
(recommended air pressure of 0.2 MPa)

Effective length

2120 mm 83.46"*3

Total length

2000 mm 78.74"

No. ofelectrodes

33

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

700 mA (at 24 V), 500 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main body

ABS/PBT/PP/LCP/PPS/SPS/SUS

Weight

2100 g 74.08oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" or more, Air supply pressure: 0.2 Mpa, Frequency: The highest device driving frequency, Operating ambient temperature: 0 to +40°C 32 to 104°F, Operating ambient humidity: 35 to 65% RH
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence FU-R67 Keyence
Sale price$0.00
Sold Out

Specifications

Model

FU-R67*1

Type

Threaded and Hex-Shaped Active Receiver Fibers

Size

M6

Fibre unit length

2 m6.6'Free-cut

Fibre unit diameter

ø 2.2ø 0.09" x 2

Shape

Threaded

Minimum bend radius

R2 mmR0.08"ToughFlex

Environmental resistance

Ambient temperature

−40 to +60 ˚C -40 to +140 °F

Weight

Approx. 21 g

*1 For details on the detecting distance, see the fiber amplifier catalog.

Keyence New Stock Image
Keyence PJ-V90 Keyence
Sale price $2,644.67
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88949 Keyence
Sale price $37,597.50
Only 1 unit left

Specifications

Model

OP-88949

Length

2 m 6.6'

keyence Stock Image
Keyence OP-90755 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-84394 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84394

Type

Panel mounting bracket

Applicable product

GT2-75/76

keyence Stock Image
Keyence OP-88760 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88760

Type

Communication cable, PVC

Length

5 m 16.4'

keyence Stock Image
Keyence ER-GR18P Keyence
Sale price$0.00
Sold Out

Specifications

Model

ER-GR18P

Type

Environment-resistant all-metal shielded type Screw type M18 Cable PNP output

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

None

Button

Function

Detecting distance

10 mm 0.39" ±10% *2

Response frequency

50 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

30 × 30 mm 1.18" × 1.18"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±20% or less of detecting distance at +25°C +77°F (-40 to -25°C -40°F to -13°F, +55 to +85°C 131°F to 185°F)

Control output

Open-collector, 30 VDC or less; 100 mA or less for 1 output;
100 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.1 V or less (Output current: 10 mA or less) /
2.4 V or less (Output current: 10 to 100 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP68G (JIS C 0920), IP69K (DIN40050)

Ambient temperature

-40 to +85°C -40°F to +185°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions

Material

Detecting surface and case: SUS316L, Nut: SUS316L, Toothed lock washer: SUS316L
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP)
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 110 g 3.88 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +70°C +158°F or higher is 33% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

Keyence Stock Image
Keyence GL-RP10P Keyence
Sale price $191.84
In stock, 12 units

Specifications

Model

GL-RP10P

Type

Unit connection cable

Number included

1 cable

Cable end

Main unit plug (Black) - Loose wires

Length

10 m 32.81'

Material

Main unit connection connector: PBT, Cable: PVC

Note

Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2)

Weight

Approx. 400 g

keyence Stock Image
Keyence OP-84459 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-84459

Applicable product

GT2-H32

Keyence Stock Image
Keyence KV-B16RC Keyence
Sale price $762.84
Only 6 units left

Specifications

Model

KV-B16RC

Type

Output unit

External connection method

Removable terminal block

Output

Number of outputs

16 points

Output mode

Relay

Rated load

250 VAC/30 VDC, 2A (8 A/1 common)

Leakage current at OFF

-

Residual voltage at ON

ON resistance

50 mΩ or less

Common method

8 points/1 common

Operation time

OFF to ON/ON to OFF: 10 ms or less

Internal current consumption

120 mA or less

Weight

Approx. 190 g

Keyence New Stock Image
Keyence CA-U2 Keyence
Sale price $654.12
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87262 Keyence
Sale price $2,324.98
Only 1 unit left

Specifications

Model

OP-87262

Type

Dedicated Stand for Mounting 12-inch LCD Monitor

Applicable product

CA-MP120T, CA-MP120

Keyence Stock Image
Keyence FU-95HA Keyence
Sale price $1,305.87
Only 1 unit left

Specifications

Model

FU-95HA

Type

Liquid-level detection fiber unit

Detecting method

Pipe mounting type

No. of beam axes

1 mm0.039"

Fibre unit length

2 m78.74" free-cut

Fibre unit diameter

ø1.0×2

Minimum bend radius

R10 mm0.394"

Environmental resistance

Ambient temperature

-40 to +105 °C -40 to 221 °F*1

Accessories

Binding band × 2, nonslip rubber × 2, spacer × 2, screw × 2, nut × 2, Fiber cutter × 1, Adaptor B × 1

Weight

Approx. 22 g

*1 When this product is used in an environment with a consistently high temperature, we recommend an ambient usage temperature of 90 °C 194 °F or less.

Recently viewed