PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
EA-300 |
|||
Analysis optical system |
Detection principle |
Laser-induced breakdown spectroscopy |
||
Supported elements |
H1 to U92 |
|||
Laser |
Laser type |
Nd: YAG laser |
||
Laser class |
Class 1 laser product (IEC/EN 60825-1, JIS C 6802, FDA (CDRH) Part 1040.10) |
|||
Laser wavelength |
355 nm |
|||
Spot size |
10 μm (typ.) |
|||
Observation optical system |
Image sensor |
1/1.8-inch, 3.19-megapixel CMOS image sensor |
||
Observation magnification |
300× to 1000× |
|||
Scanning system |
Progressive |
|||
Frame rate |
50 fps (max.) |
|||
Optical system |
Lens type |
Specially designed reflective objective lens |
||
Objective lens working distance |
25 mm 0.98" |
|||
High dynamic range |
16-bit intensity range through RGB data from each pixel |
|||
Gain |
Manual, Preset |
|||
Electronic shutter |
Auto, Manual, 1/60, 1/120, 1/250, 1/500, 1/1000, 1/2000, 1/5000, 1/9000, 1/19000 |
|||
Supercharge shutter |
Can be set in 0.01 s increments from 0.02 to 16 s |
|||
White balance |
Push-set, Manual, Preset (2700K, 3200K, 5600K, 9000K) |
|||
Built-in coaxial illumination light source |
Type |
High-brightness LED |
||
Service life |
100000 hours (reference value) |
|||
Color temperature |
5810K (typ.) |
|||
Built-in ring illumination light source |
Type |
High-brightness LED |
||
Service life |
100000 hours (reference value) |
|||
Color temperature |
5810K (typ.) |
|||
Power supply |
Power supply method |
Power supplied via dedicated cable from VHX Series controller camera port |
||
Environmental resistance |
Ambient temperature |
10 to 33°C 50.0°F to 91.4°F |
||
Relative humidity |
35 to 80% RH (No condensation) |
|||
Dimensions |
280 (W) × 375 (H) × 210 (D) mm 11.02"(W) × 14.76" (H) × 8.27" (D) (with lens stored) (excluding protrusions) |
|||
Weight |
Approx. 7.2 kg 15.87 lb (Analysis system main unit) |
|||

Specifications
Model |
GS-51PCSO(3195) |
|||
Lock type |
Power-to-release type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
220 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 380 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
SV2-L1A |
|||
Type |
MECHATROLINK-III conversion cable (RJ45/IMI conversion) |
|||
Length |
1 m 3.3' |
|||

Specifications
Model |
OP-84292 |
|||
Type |
Tungsten electrode probes/Tungsten accelerating electrode probes |
|||
Applicable product |
Made for SJ-H |
|||
Number included |
Tungsten electrode probes (four) |
|||
Material |
Tungsten |
|||

Specifications
Model |
FL-SP180 |
|||
Total length (at 25 °C) |
1833 |
|||
Measurement range (dead zone excluded) |
1,764 (1,719)*1 |
|||
Weight |
Approx. 980 g |
|||
*1 Values for water. For oil | ||||

Specifications
Model |
FR-LP20 |
|||
Type |
Long range Chemical model |
|||
Measuring range |
Up to 20 m 65.6'*1 |
|||
Display range |
Up to 25 m 82.0'*1 |
|||
Measurable dielectric constant of medium |
2 or higher*2 |
|||
Resolution |
1 mm 0.04" |
|||
Precision |
Up to 0.1 m 0.3': ±10 mm 0.39"; |
|||
Response time |
0.4 s, 1.5 s, 4 s (default value), 10 s |
|||
Tank pressure |
-0.1 to +0.1 Mpa |
|||
Material |
Tank interior |
Lens: PTFE |
||
Housing |
PPS PPSU |
|||
Connection diameter |
G1-1/2 (40 A) |
|||
Output |
No. of control outputs |
Maximum 5 |
||
Control output/auxiliary output |
NPN/PNP open collector (switching type) |
|||
Analog output |
0–20 mA/4–20 mA maximum load resistance 260 Ω |
|||
External input |
─ |
|||
Network compatibility |
IO-Link v1.1/COM2 |
|||
Analog output accuracy |
Resolution |
1 mm 0.04"*4 |
||
Zero accuracy |
±0.1 mA (zero point = 4 mA)*4 |
|||
F.S. accuracy |
±0.2 mA (full-scale = 20 mA)*4 |
|||
Power supply |
Power voltage |
24 VDC + 25%/–20% |
||
Power consumption |
98 mA or less (Excluding Load Current) |
|||
Environmental resistance |
Ambient temperature |
Display part when combined and separated: –10 to +50°C 14°F to 122°F (no freezing)*5*6 |
||
Relative humidity |
Up to 85% RH (no condensation) |
|||
Temperature of coupling used |
–10 to +85°C 14°F to 185°F (no freezing)*5*7 |
|||
Vibration resistance |
10–500 Hz Power spectral density: 0.816 G2; X, Y and Z directions |
|||
Shock resistance |
100 m/s2 (10 G), 16 ms pulses, 1000 times each for X, Y and Z directions |
|||
Enclosure rating |
IP67 (IEC60529), Enclosure Type 4X (NEMA250) |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent protection, and output surges |
|||
Weight |
Approx. 400 g 14.11 oz |
|||
*1 Guaranteed value in water with the recommended installation. Static water can be measured up to the edge of the lens. An undetectable area on the short-range side is created due to the environment and measurement medium. The maximum measuring distance is also shortened. | ||||

Specifications
Model |
CA-HS200C |
|||
Image element |
Color CMOS, 7×/16× high-speed reading using square-pixel |
|||
Unit cell size |
3.45 µm × 3.45 µm 0.14 Mil × 0.14 Mil |
|||
Valid pixel count |
2 megapixel mode: 1600 (H) × 1200 (V), 1 megapixel mode: 1024 (H) × 960 (V) |
|||
Image size |
Equivalent to 1/2" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
At 7× transfer speed: 86 MHz (43 MHz × 2)*1, At 16× transfer speed: 198 MHz*2 |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.05 to 9000 msec by specifying the following numerical inputs: |
|||
Lens mount |
Special mount (M15.5 P0.5 male) |
|||
Environmental resistance |
Ambient temperature |
0 to 45°C 32 to 113°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 45 g (not including lens) |
|||
*1 Transfer speed setting: Standard | ||||

Specifications
Model |
GL-VM14LP |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
14 |
|||
Total length |
560 mm 22.05" |
|||
Detection height |
520 mm 20.47" |
|||
Protection height |
605 mm 23.82" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.5 |
|
OFF→ON |
46.5 *3 |
|||
All blocked→ON |
52.5 *4 |
|||
With channel A or B |
ON→OFF |
11.4 |
||
OFF→ON |
58.8 *3 |
|||
All blocked→ON |
74.0 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
83 *5 |
||
Receiver |
96 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
50 *5 |
||
Receiver |
57 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
370 g 13.06 oz |
||
Receiver |
380 g 13.41 oz |
|||
Total |
750 g 26.47 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||



PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
ET-305 |
|||
Type |
Sensor Head, Shielded Type |
|||
Shape |
Cylindrical |
|||
Detecting distance |
0 to 1.0 mm 0.04" |
|||
Detectable object |
Nonferrous metals |
|||
Standard target (aluminum, t=1 mm 0.04") |
5 x 5 mm 0.20" |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Response frequency |
1 kHz |
|||
Hysteresis adjustment |
1-turn trimmer (240°), approx. 2 to 10% of detecting distance (variable) |
|||
Operation mode |
15-turn trimmer |
|||
Temperature characteristics |
+25 to -15% max. of detecting distance at 23°C 73.4°F, |
|||
Output |
Control output |
100 mA max. (40 V max.), Residual voltage: 1 V max. |
||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Current consumption |
45 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Accessories |
― |
|||
Weight |
Approx. 50 g (including 3m cable) |
|||

Specifications
Model |
ER-GW12P |
|||
Type |
Weld-resistant all-metal shielded type Screw type M12 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
7 mm 0.28" ±10% *2 |
||
With distance switching (Mode 2) |
3 mm 0.12" ±10% *2 |
|||
Response frequency |
2 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
21 × 21 mm 0.83" × 0.83" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
1000 mW or less (42 mA or less at 24 V, 63 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +85°C -13°F to +185°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface and case: SUS303 with ceramic coating, Button: PBT, Nut: SUS303 with ceramic coating, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 75 g 2.65 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
GS-MB21 |
|||
Type |
Hinged door |
|||
Applicable model |
for GS-M9 Series |
|||
Frame size |
30 - 40 mm 1.18" - 1.57" |
|||
Weight |
Approx. 85 g 3.00 oz |
|||


Specifications
Model |
CL-P150 *1 |
|||
Type |
Sensor head (150 mm・Focused spot type) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FS-V32C |
|||
Type |
1-output + 1-input |
|||
Output |
NPN |
|||
Main unit/Expansion unit |
Expansion unit |
|||
Control output |
1 output |
|||
Monitor output (1 to 5 V) |
N/A |
|||
External input |
1 input |
|||
Connector |
M8 |
|||
Light source LED |
Red, 4-element LED (Wavelength: 640 nm) |
|||
Response time |
33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO) |
|||
Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
|||
Display indicator |
Operation indicator: Red LED/Dual digital monitor: Dual 7-segment display, Preset Value (4-digit green LED indicator) and |
|||
Size |
30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D) |
|||
Detection mode |
Light intensity (area detection possible, automatic sensitivity-tracking function provided) |
|||
Timer function |
OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable |
|||
Control output |
NPN open-collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max. |
|||
External inputy |
Input time: 2 ms (ON)/20 ms (OFF) min.*2 |
|||
Unit expansion |
Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units. |
|||
Number of interference prevention units |
Normal operation |
HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台 |
||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Power consumption |
Normal: 710 mW max. (Using 24 V, 29 mA max., using 12 V, 40 mA max.)/Power saving: 540 mW max. (Using 24 V, 22 mA max., using 12 V, 28 mA max.)*3 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*4 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Polycarbonate |
|||
Accessories |
N/A |
|||
Weight |
Approx. 45 g |
|||
*1 Total current of two outputs should be less than 100 mA. | ||||