Specifications
Model |
FS-N12CN |
|||
Type |
Standard 1 output |
|||
Output |
NPN |
|||
Main unit/expansion unit |
Expansion unit |
|||
Control output |
1 |
|||
Monitor output (1-5 V) |
- |
|||
External input |
1 |
|||
Light source LED |
Red, 4-element LED |
|||
APC |
ON/OFF switchable (Factory setting: OFF) |
|||
Response time |
50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||
Number of interference prevention units |
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA |
|||
Unit expansion |
Up to 16 units can be connected total (two output type is treated as two units) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current Consumption |
Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*2 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less |
||
Ambient temperature |
-20 to +55 °C -4 to +131 °F (No freezing)*3 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Both main unit and expansion unit housing material: Polycarbonate |
|||
Weight |
Approx. 22 g |
|||
*1 Use a cable length of 30 m 98.43' or less for M8 connector and e-CON connector types. | ||||

Specifications
Model |
OP-86939 |
|||
Type |
Dedicated L-shaped mounting bracket with angle alignment |
|||
Applicable product |
SZ |
|||
Material |
SPHC |
|||
Weight |
Approx. 960 g |
|||

Specifications
Model |
MP-FG20 |
|||
Type |
Single model |
|||
Connection bore diameter |
G1/2" (15A) |
|||
Supported gases |
Air and non-corrosive gases |
|||
Supported gas temperature |
-5 to +50°C, 23 to 122°F |
|||
Operating pressure range |
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 |
|||
Pressure resistance |
1.5 MPa, 15 bar, 217.5 psi |
|||
Flow rate |
Detection principle |
Heat based (mass flow rate) |
||
Rated flow range (normal) |
4 to 2000 L/min |
|||
Zero cut flow rate |
4 L/min, 0.2 m3/h 7.06 ft3/h, 0.1 CFM |
|||
Measurement accuracy |
±(1.5% of RD + 0.5% of F.S.) *2 *3 |
|||
Repeatability |
±1.0% of F.S. (with an averaging time of 1.0 s) |
|||
Display resolution |
1 L/min, 0.1 m3/h 3.53 ft3/h, 0.1 CFM |
|||
Response time |
150 ms (63% response) *4 |
|||
Averaging time |
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) |
|||
Pressure (Digital value, gauge pressure) |
Rated pressure range |
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi |
||
Measurement accuracy |
±2.0% of F.S. |
|||
Repeatability |
±0.2% of F.S. (with a response time of 50 ms) |
|||
Display resolution |
0.001 MPa, 0.01 bar, 0.1 psi |
|||
Response time |
Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4 |
|||
Humidity (Dew point) |
Rated relative humidity range/ dew point range |
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 |
||
Measurement accuracy |
±4°C, ±7°F *5 *6 |
|||
Display resolution |
5%RH/1°C, 1°F *5 *6 |
|||
Temperature |
Measurement accuracy |
±2.0°C, ±3.6°F *7 |
||
Display resolution |
0.1°C, 0.1°F *7 |
|||
Shut-off valve |
Response time |
1 s or less (closed → open) |
||
Leakage amount |
50 mL/min 0.002 CFM (N) or less |
|||
Filter/regulator (Standard model only) |
Pressure adjustment range |
─ |
||
Filtration degree | ||||
Drainage cup capacity | ||||
Check valve |
Available |
|||
Display |
Color LCD, status indicator |
|||
Data accumulation |
Accumulation period |
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks |
||
Data reading |
USB 2.0/Ethernet |
|||
I/O |
Control output (Ch.1/2/3/4/5) |
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less |
||
Analog output (Ch.1/2) |
4 to 20 mA, load resistance: 260 Ω or less *4 |
|||
External input (Ch.2/3/6) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output |
|||
Power supply |
Power voltage |
24 VDC +25%/-20% (including ripple), Class 2 or LPS |
||
Power consumption |
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current) |
|||
Communication interface |
USB2.0 |
|||
Network compatibility |
When using only this unit: IO-Link (Specification v1.1/COM3) *9 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient temperature |
−5°C to +50°C 23°F to 122°F (no freezing) *11 |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
300 m/s2, XYZ axes, 10 times for each axis |
|||
Material |
Sensor part : PET/PPS/PBT/POM/aluminum/SPHC |
|||
Weight |
Approx. 1020 g 35.98 oz |
|||
*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve. | ||||

Specifications
Model |
OP-88666 |
|||
Type |
Ethernet cable (M12 X-coded 8-pin) NFPA79-compatible |
|||
Length |
10 m 32.8' |
|||
Weight |
Approx. 650 g |
|||

Specifications
Model |
CA-DC30E |
|||
Type |
Illumination Controller |
|||
Input |
- |
|||
Output |
Light control method |
Constant current control method |
||
Intensity range |
255 level digital [Program setting] |
|||
Connection points |
2 ch |
|||
Voltage |
LumiTraxTM light dedicated power supply |
|||
Capacity |
Max. 81 W |
|||
Synchronization |
Camera trigger/shutter speed synchronization |
|||
Response speed |
Under 1 ms |
|||
Display |
LED display |
Power indication, light status indication (2 ch individually) |
||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
5 A (at maximum load)*1 |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*2*3 |
||
Relative humidity |
85%RH or less (No condensation)*4 |
|||
Weight |
Approx. 430 g |
|||
*1 Out of which the current consumption of controller is 1.6 A. | ||||

Specifications
Model |
SV2-300L2 |
|||
General specifications |
Capacity |
3.0 kW |
||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase 200 to 240 VAC +10 to -15%, 50/60 Hz |
|
Control circuit |
Single-phase 200 to 240 VAC +10 to -15%, 50/60 Hz |
|||
Allowable frequency fluctuation |
Main circuit/control circuit |
No more than ±5% |
||
Overvoltage category |
III |
|||
Control mode |
Three-phase full-wave rectification, IGBT, PWM control, sine-wave current driving method |
|||
Feedback |
22-bit serial encoder (absolute) communication, |
|||
Operating environment |
Operating atmosphere |
Enclosure rating |
IP10 |
|
Pollution degree |
Pollution degree: 2 (in an IP54 or higher control panel) |
|||
Operating ambient temperature |
-5 to +60°C 23 to 140°F (no freezing; reduced ratings at +55°C 131°F or more) |
|||
Storage ambient temperature |
-20 to +85°C -4 to +185°F (no freezing) |
|||
Operating/storage ambient temperature |
95% RH or less (no condensation) |
|||
Altitude |
2000 m 6561.7' or less above sea level (usable at reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration resistance |
4.9 m/s2 16.1'/s2 (JIS C60068-2-6 compliant) |
|||
Impact resistance |
19.6 m/s2 64.3'/s2 ( JIS C60068-2-27 compliant) |
|||
Other |
No static electricity noise, strong electric fields, magnetic fields, or radiation present |
|||
Min. insulation resistance |
500 VDC, 1 MΩ or more with insulation resistance tester |
|||
Applied standard |
UL/CSA standards |
UL61800-5-1, CSA22.2 No.274 |
||
CE marking |
Low-voltage directive |
EN61800-5-1, EN50178 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Structure |
Type |
Attached to base mount |
||
Safety function |
STO function (STO/EN61800-5-2) |
|||
Safety function |
Safety parameters |
SIL3/EN61508, SIL CL 3/EN62061, |
||
Response time |
8 ms (max.) |
|||
Input |
STO1, STO2: Base block signal for power module |
|||
Output |
EDM: Built-in safety circuit status monitoring (fixed output) |
|||
Applied standard |
EN61800-5-2, EN ISO13849-1: 2008, EN61508, EN62061, EN60204-1, EN61326-3-1 |
|||
Protection function |
Overcurrent, overvoltage, undervoltage, overload, regenerative abnormalities, etc. |
|||
Insulation withstand voltage |
1500 VAC or more (between primary side and ground) |
|||
Weight |
Approx. 2.7 kg |
|||
Power supply/current capacity and power loss |
Main circuit power supply |
Three-phase 200 V |
||
Max. applicable motor capacity |
3.0 kW |
|||
Power supply capacity for 1 amplifier |
Three-phase 200 V: 5.9 kVA |
|||
Output current |
Continuous |
19.6 Arms |
||
Max. |
56 Arms |
|||
Main circuit power loss |
113.8 W |
|||
Regenerative resistor power loss |
16 W |
|||
Control circuit power loss |
22 W |
|||
Total power loss |
151.8 W |
|||
Rated input current |
Main circuit |
Three-phase 200 V: 15 Arms |
||
Control circuit |
0.25 Arms |
|||
Rush current |
Main circuit |
34 A |
||
Control circuit | ||||
Performance specifications |
Performance |
Speed control range |
1:5000 (load torque ≤ rated torque conditions) |
|
Speed fluctuation rate |
At load fluctuation |
±0.01% or less with load fluctuations of 0 to 100% (at rated rotation speed) |
||
At main circuit voltage change |
0% with ±10% of rated voltage (at rated rotation speed) |
|||
At ambient temperature change |
±0.1% or less with ambient temperatures of 0 to +50°C 32 to 122°F (at rated rotation speed) |
|||
Torque control accuracy (reproducibility) |
±1% |
|||
Speed frequency response frequency |
2.6 kHz |
|||
Dynamic brake |
Operated at main circuit power supply OFF, servo alarm, limit switch detection (LSP/LSN), forced stop detection (FSTOP) |
|||
Regenerative resistor |
Built-in regenerative resistor: 50 W to 400 W ... not installed |
|||
Display Function |
Panel function |
7-segment LED |
||
Status display LED |
CHARGE: For notification of main circuit power supply input (orange) |
|||
Auxiliary function |
Gain control, alarm history, Z-phase search, etc. |
|||
I/O specifications |
Sequence input signal |
Number of inputs |
7 (3 high-speed input, 4 general input) |
|
Max. input voltage |
28.8 VDC |
|||
Rated input voltage |
24 VDC |
|||
Min. ON voltage |
19 VDC |
|||
Min. OFF current/voltage |
High-speed input: 0.6 mA, general input: 0.3 mA |
|||
Common point mode |
7 points/1 common point (1 terminal) (bidirectional) |
|||
Input time constant |
250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
|||
Input current |
High-speed input: 4.5 mA, general input: 3.7 mA |
|||
Input impedance |
Approx. 4.7 kΩ |
|||
Assignable input signals |
Full signal assignment, logic-settable forced stop (FSTOP), |
|||
Sequence output signal |
Number of outputs |
4 |
||
Output mode |
Transistor NPN output |
|||
Rated load |
30 VDC / 50 mA |
|||
Leakage current when OFF |
0.1 mA |
|||
Residual voltage when ON |
1.5 VDC or less |
|||
Common point mode |
Independent common |
|||
Assignable output signals |
Individual signal assignment excluding ALARM signal, logic-settable alarm (ALARM), |
|||
Analog Feedback Input signal monitor |
Max. input voltage |
±12 V |
||
Accuracy |
±1% of F.S. |
|||
Resolution |
±10 bits |
|||
Input impedance |
30 kΩ |
|||
Encoder division pulse output signal |
Output mode |
Phase A (A+/A−), phase B(B+/B−), phase Z (Z+/Z−): Differential line-driver output |
||
Line driver |
SN75ALS174 (T.I.) or equivalent |
|||
Output frequency |
1.6 Mbps (with 2-phase, 4 times multiplication, 6.4 MHz or equivalent) *3 |
|||
Analog monitor output |
No. of channels |
2 ch |
||
Output range |
±10 V (linearity valid range ±8 V) |
|||
Resolution |
16 bits |
|||
Conversion precision |
±20 mV (typ.) |
|||
Max. allowable load current |
±10 mA |
|||
Conversion speed |
1.2 ms (typ.) |
|||
Communication specifications |
MECHATROLINK-III communication |
Communication protocol |
MECHATROLINK-III |
|
Station address |
03H to EFH (Max. number of connectable slaves: 62) |
|||
Transmission speed |
100 Mbps |
|||
Transmission frequency |
125 μs, 250 μs, 500 μs, 750 μs, 1 to 4 ms (in multiples of 0.5 ms) |
|||
Communication cycle |
Support for values starting at transmission frequency × 1 |
|||
Number of transmitted bytes |
32 bytes/station, 48 bytes/station (selectable with slide switch) |
|||
Transmission media/cable |
Category 5e-compliant, STP cross cable |
|||
Operating specifications |
Position control / speed control / torque control |
|||
Command input |
MECHATROLINK-III command |
|||
Max. transmission distance |
50 m 164.0' *4 |
|||
USB communication |
Connected device |
PC |
||
Communication standard |
USB 2.0-compliant |
|||
Function |
Status display, parameter setting, tuning, etc. |
|||
*1 When using a DC power supply input, set “*AC/DC power supply” to “DC”. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-R77G*1 |
|||
Type |
Threaded and Hex-Shaped Active Receiver Fibers |
|||
Optical axis diameter |
Transmitter: ø 1ø 0.04" Receiver: ø 3.2ø 0.13" |
|||
Size |
M4 |
|||
Fibre unit length |
1 m3.3'Cut not allowed |
|||
Shape |
Threaded |
|||
Minimum bend radius |
R10 mmR0.39"Stainless Steel |
|||
Environmental resistance |
Ambient temperature |
−40 to +60 ˚C -40 to +140 °F |
||
Weight |
Approx. 41 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CL-S015 *1 |
|||
Type |
Sensor head (Ultra-high-accuracy 15 mm model) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
SJ-Q132 |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 Vmax |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±3 V *1 |
|||
Clean rating |
ISO14644-1 Class 3 *2 |
|||
Installation distance |
10 mm 0.39" or more |
|||
Control input |
Static elimination stop input |
NPN open collector or non-voltage contact signal |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector |
||
Condition alarm output | ||||
Alarm output | ||||
Communication functions |
Remote control |
|||
Average power consumption |
Normal operation: 8.4 W, |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc1/8 |
|||
Air supply pressure |
0.1 to 0.5 MPa 14.50 to 72.52 PSI (recommended air pressure: 0.2 MPa 29.01 PSI)*4 |
|||
Effective length |
1400 mm 55.12" *5 |
|||
Total length |
1280 mm 50.39" |
|||
No. ofelectrodes |
21 |
|||
Rating |
Power voltage |
24 to 36 VDC±10% |
||
Current consumption |
Normal operation: 700 mA or less, |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
85% RH or less (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1580 g 55.77 oz |
|||
*1 Measured under the following conditions. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-26500 |
|||
Type |
Adapter A for f1.3 Fiber Unit |
|||
Applicable product |
ø1.3 fiber unit |
|||
Number included |
1 pcs. |
|||
Note |
Necessary when small diameter fiber unit is used with FS-N/V/T/M Series. |
|||

Specifications
Model |
TM-X5040 |
|||
Transmitter/receiver distance |
180 mm 7.09" |
|||
Measuring range |
Field of view |
High-accuracy measurement area |
ø26 mm ø1.02" |
|
Measurement area |
ø40 mm ø1.57" |
|||
Depth of field |
High-accuracy measurement area |
10 mm 0.39" |
||
Measurement area |
20 mm 0.79" |
|||
Exposure time |
25/50/100 μs (Adjustable 3-stage) |
|||
Imaging time (Trigger interval) |
Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes) |
|||
Light source |
InGaN green LED |
|||
Measurement position accuracy |
High-accuracy measurement area |
±1 μm ±0.000039" *1 |
||
Measurement area |
±2 μm ±0.000079" *1 |
|||
Repeatability |
±0.08 μm ±0.000003" *2 |
|||
Pixel resolution |
Approx. 21 μm 0.000827" |
|||
Environmental resistance |
Enclosure rating |
IP64 *3 |
||
Ambient temperature |
0 to +45°C 32 to 113°F |
|||
Relative humidity |
85% RH or less (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter: Approx. 620 g 21.89 oz |
|||
*1 Error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
CA-LS4 |
|||
Type |
Lens |
|||
Overview |
Specialised lens for the compact camera (ø12 ø0.47"). |
|||



Specifications
Model |
SJ-E300A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
3060 mm 120.47"*3 |
|||
Total length |
2960 mm 116.54" |
|||
No. ofelectrodes |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2900 g 102.29oz |
|||
*1 Measured under the following conditions. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
OP-87586 |
|||
Cable end |
M12 L-shaped type - Loose wires |
|||
Length |
2 m 6.56' |
|||
Material |
Covering: PUR, Nut: Nickel plating over zinc die-cast |
|||

Specifications
Model |
EM-054 |
|||
Type |
Shielded |
|||
Shape |
5.4 mm 0.21" dia Cylindrical. |
|||
Detecting distance |
1.2 mm 0.05" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
6 x 6 mm 0.24" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Output |
NPN |
|||
Control output |
NPN: 200 mA (40 V) max., Residual voltage: 1 V max. |
|||
Housing |
Stainless steel |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*1 |
||
Current consumption |
12 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 40 g (including nuts and 2-m 6.6' cable) |
|||
*1 Make sure that the power voltage stays within 10.8 V to 30 V even if it is affected by ripple effects. | ||||