Specifications
Model |
KV-C64TD |
|||
Type |
Output unit |
|||
External connection method |
Connector (MIL standard)*1 |
|||
Output |
Number of outputs |
64 points |
||
Output mode |
MOSFET (sink) (with overcurrent protection function) |
|||
Rated load |
30 VDC, 0.2 A |
|||
Leakage current at OFF |
100 μA or less |
|||
Residual voltage at ON |
0.5 V or less |
|||
ON resistance |
- |
|||
Common method |
64 points/1 common (4 terminals)*2 |
|||
Operation time |
OFF to ON: 150 μs or less,ON to OFF: 300 μs or less |
|||
Internal current consumption |
120 mA or less |
|||
Weight |
Approx. 140 g |
|||
*1 Connectors for connector-type I/O units are not included XC Series Terminal Block Conversion Unit is available. | ||||



Specifications
Model |
FU-24X*1 |
|||
Size |
M3 |
|||
Detection arrangement |
Coaxial |
|||
Fibre unit length |
50 cm19.685" cannot be cut |
|||
Shape |
Straight |
|||
Minimum bend radius |
R10 mm0.394" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 4 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
GL-R16H |
|||
Detection capability |
ø0.98" ø25 mm |
|||
Total length |
12.60" 320mm |
|||
No. of beam |
16 |
|||
Detection height |
11.81" 300mm |
|||
Protection height |
13.58" 345mm |
|||
Beam axis spacing/Lens diameter |
20 mm / ø5 0.79" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
6.6 |
|
OFF→ON |
48.7*2 |
|||
All blocked→ON |
63.1*3 |
|||
Optical synchronization system |
ON→OFF |
8.1 |
||
OFF→ON |
50.9*2 |
|||
All blocked→ON |
69.1*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
50 |
||
Receiver |
69 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
430 g |
||
Receiver |
440 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||


Specifications
Model |
SZ-VP5 |
|||
Type |
18-core Power cable |
|||
Applicable product |
SZ-V Series |
|||
Cable end |
Connector (connected to the SZ-V) - Loose wires |
|||
Length |
5 m 16.40' |
|||
Material |
PVC |
|||
Weight |
Approx. 400 g |
|||

Specifications
Model |
GL-VM31FN |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
31 |
|||
Total length |
320 mm 12.60" |
|||
Detection height |
300 mm 11.81" |
|||
Protection height |
324 mm 12.76" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
5.1 |
|
OFF→ON |
48.4 *3 |
|||
All blocked→ON |
55.4 *4 |
|||
With channel A or B |
ON→OFF |
14.2 |
||
OFF→ON |
63.3 *3 |
|||
All blocked→ON |
82.9 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
73 *5 |
||
Receiver |
83 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
54 *5 |
||
Receiver |
59 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
220 g 7.76 oz |
||
Receiver | ||||
Total |
440 g 15.53 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
SJ-H060A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
600 mm 23.62" *3 |
|||
No. ofelectrodes |
8 |
|||
Static elimination bar length |
560 mm 22.05" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
780 g 27.51 oz |
||
*1 Measured under the following conditions. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FU-85Z*1 |
|||
Heat resistant temperature |
100°C 212°F*2*3 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Minimum bend radius |
R5 mm0.197" Tough-Flex |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *4 |
|||
Environmental resistance |
Ambient temperature |
-40 to +100 °C -40 to 212 °F |
||
Weight |
Approx. 25 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||



Specifications
Model |
NR-CT050 |
|||
Primary side rated current (In) |
50 A |
|||
Overcurrent withstand capability |
1.2 times the primary side rated current (can be continuous) |
|||
Maximum wire diameter that can be installed |
ø10 0.39" |
|||
Installation method |
Clamp type (split core) |
|||
Ratio error to current load |
±0.5% of rdg |
|||
Phase difference for current load |
± 90’ (20% In) |
|||
Protection element |
Internal clamping element |
|||
Environmental resistance |
Insulation resistance |
500 V DC/100 M Ω or more |
||
Ambient temperature |
-10°C to +55°C 14°F to 131°F (no freezing) |
|||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Withstand voltage |
2300 V AC/minute |
|||
Weight |
Approx. 140 g 4.94 oz (with cable) |
|||

Specifications
Model |
MS2-H75 |
|||
Input conditions |
Input voltage |
85 to 264 VAC, 110 to 370 VDC*1 |
||
Frequency |
47 to 63 Hz, DC*1 |
|||
Inputconditions |
Input current (100/200 VAC) |
1.9/0.9A or less |
||
Efficiency (100/200 VAC) |
82, 85% typ. (at 100% load) |
|||
Leakage current (100/200 VAC) |
0.4, 0.75 mA or less (at 100% load) |
|||
Rush current (100/200 VAC) |
25, 50 A or less (at 100% load with a +25°C 77°F cold start) |
|||
Output characteristics |
Rated voltage |
24V |
||
Variable voltage range |
±5% (with V.ADJ) |
|||
Rated current |
3.2A |
|||
Ripple/noise voltage |
180mV (p-p) or less |
|||
Input fluctuation |
0.4% or less |
|||
Load fluctuation |
1.5% or less |
|||
Temperature fluctuation |
0.02%/°C or less |
|||
Startup time |
500 ms or less (when the ambient usage temperature is between 0 and +55°C 32 and 131°F with rated I/O conditions) |
|||
Output holding time |
20 ms or more (when the ambient usage temperature is +25°C 77°F and with rated I/O conditions) |
|||
Protection |
Overcurrent protection |
Constant current drop method, automatic recovery, 4.0 A or more |
||
Overvoltage protection |
Activates at 26.4 V or more, voltage interruption method, recovers when input is applied again*2 |
|||
Display |
Display power |
3-digit 7-segment LED (character height: 10 mm 0.39") |
||
Power off memory time |
Approx. 10 years (at +20°C 68°F) |
|||
Display resolution |
0.1A/0.4V /1% |
|||
Applicable standards |
Safety standards |
UL: UL508, UL60950-1; C-UL: CSA C22.2 number 14-M95, CSA C22.2 number 60950-1-03; EN: EN60950-1, EN50178; IEC: IEC60950-1 |
||
EMC standard |
FCC Part 15 B Class A, EN55011 Class A, EN61000-6-2 |
|||
Limits for harmonic current emissions |
EN61000-3-2*3 |
|||
Other |
Parallel operation |
Possible (requires OP-42207)*4 |
||
Series operation |
Possible (requires external diode)*4 |
|||
Cooling method |
Natural air cooling |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more at 500 VDC |
||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) (see the derating characteristics) |
|||
Relative humidity |
25 to 85 % RH (No condensation) |
|||
Storage temperature |
-20 to +70 °C -4 to 158 °F (No freezing) |
|||
Withstand voltage |
3.0 kVAC, 50/60 Hz, 1 min (across input and output terminals) |
|||
Vibration resistance |
10 to 57 Hz, Double amplitude 0.3 mm 0.01", 57 to 500 Hz, 19.6 m/s2 (2 G), cycle: 5.5 minutes, 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
Peak acceleration: 300 m/s2, 2 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 470 g |
|||
*1 The rated input voltage and rated frequency when applying for safety standards are 100 to 240 VAC, 50/60 Hz. | ||||

Specifications
Model |
OP-87639 |
|||
Number included |
1 |
|||
Cable end |
M12 L-shaped - Loose wire |
|||
Length |
10 m 32.81' |
|||
Material |
Cable: PVCConnector: Zinc nickel plating |
|||
Weight |
Approx. 410 g |
|||

Specifications
Model |
MD-F5100 |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-Axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: fiber laser, Class 4 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
||
Wavelength |
1090 nm |
|||
Output |
50W |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
|||
Marking area |
120 x 120 x 42 mm 4.72" x 4.72" x 1.65" |
|||
Standard working distance (±variable width) |
168 mm (± 21 mm) 6.614"(± 0.827") |
|||
Marking resolution |
2 µm 0.08 Mil |
|||
Scan speed |
12000 mm 472.44/s max. |
|||
Character type |
Font |
KEYENCE original font (numerical value, alphabet, katakana, hiragana, and kanji)/user font/true type font |
||
Barcode |
CODE39/ITF/2of5/NW7 (CODABAR)/JAN/EAN/UPC/CODE128 |
|||
2D code |
QR code/micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar Truncated/GS1 DataBar Truncated CC-A/GS1 DataBar Stacked/GS1 DataBar Stacked CC-A/GS1 DataBarLimited/GS1 DataBar Limited CC-A |
|||
Logo image |
Custom font, logo (CAD) data BMP/JPEG/PNG/TIF |
|||
Machinery operation |
Fixed point/straight line/dashed line/oval |
|||
Marking conditions |
Workpiece style |
Stationary marking/movement marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 120 mm 0.004" to 4.72" |
|||
No. of registered programs |
2000 settings max. |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block input and output/MIL connector input and output |
|||
Interface |
RS-232C, RS-422A, USB 2.0,*2 Ethernet (100BASE-TX/10BASE-T) |
|||
CF memory card slot |
Compact flash memory card*3 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4 m 13.12' |
|||
Cooling method |
Controller: forced air cooling, head: natural air cooling |
|||
Rated voltage and power consumption |
100 to 120 VAC or 200 to 240 VAC ± 10 %, 50/60 Hz, Max. 750 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 27.5 kg |
|||
*1 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA [CDRH] Laser Notice. | ||||

Specifications
Model |
OP-3145 |
|||
Type |
Reflector R-1 |
|||
Overview |
Reflector used with polarized retro-reflective photoelectric sensor. |
|||
Applicable product |
PZ, PW |
|||
Material |
Reflector: Acrylic, Base: ABS |
|||

Specifications
Model |
PR-FB30CN |
|||
Type |
Reflective (Background suppression) |
|||
Output |
NPN |
|||
Shape |
Flat |
|||
Cable connection |
M8 connector (4 pin) |
|||
Detection distance |
1 to 30 mm 0.039" to 1.181" |
|||
Number of control outputs |
2 |
|||
Output operation |
Output 1 |
Light-ON |
||
Output 2 |
Dark-ON |
|||
Response time |
Output 1 |
0.5 ms |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. ø5 mm (at 30 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 % |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 10 g |
|||

Specifications
Model |
CA-LH16 |
|||
Focal point |
16 mm 0.63" |
|||
F-stop range (aperture) |
F1.4 to F16 |
|||
Minimum WD |
0.2 m 0.7' |
|||
Mount |
C-mount |
|||
Filter size |
25.5 mm 1.00" P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
-0.05 % (-0.1 %)*1 |
|||
Resolving power |
100 cycles/mm at center, 80 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Weight |
Approx. 81 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||

Specifications
Model |
GL-VM143FN |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
143 |
|||
Total length |
1440 mm 56.69" |
|||
Detection height |
1420 mm 55.91" |
|||
Protection height |
1444 mm 56.85" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
9.8 |
|
OFF→ON |
54.8 *3 |
|||
All blocked→ON |
68.8 *4 |
|||
With channel A or B |
ON→OFF |
33.0 |
||
OFF→ON |
94.6 *3 |
|||
All blocked→ON |
142.3 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
157 *5 |
||
Receiver |
176 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
65 *5 |
||
Receiver |
73 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
940 g 33.18 oz |
||
Receiver |
950 g 33.53 oz |
|||
Total |
1890 g 66.71 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||