Specifications
Model |
OP-85139 |
|||
Overview |
Polarizing filter for the red IR LED type. (Used for thrubeam models to prevent interference.) |
|||
Applicable product |
PZ-G52 |
|||
Number included |
3 pcs. |
|||
Material |
Acetate plastic |
|||
Weight |
Approx. 1 g |
|||

Specifications
Model |
EG-530 |
|||
Type |
DC |
|||
Sensitivity adjustment |
15-turn trimmer |
|||
Function |
Operation mode |
N.O./N.C. (switch-selectable) |
||
Operation mode |
External synchronization |
― |
||
Output |
Control output 1 (NPN) |
100 mA max. (40 V max.) Residual voltage: 1 V max. |
||
Control output 2 |
― |
|||
Disconnection alarm output |
100 mA max. |
|||
Response |
1 ms |
|||
― | ||||
OFF-delay time | ||||
Temperature characteristics |
0.08%/°C*1 |
|||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less |
||
Power consumption |
100 mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 75 g |
|||
*1 Above values obtained when the detecting distance is set at 50% of the maximum stable detecting distance. | ||||

Specifications
Model |
RC-14 |
|||
Type |
1-level preset counter/timer, DC type |
|||
Operation method |
Addition, subtraction |
|||
Operation mode |
Overcount, auto reset |
|||
Return method |
Manual reset, external reset, automatic reset (in auto reset mode) |
|||
Display power |
7-segment LED (character height: 10 mm) |
|||
Number of digits |
6-digit display, -99,999 to 999,999*1 |
|||
Power off memory time |
Approx 10 years (at 20°C 68°F) |
|||
Mounting method |
Panel mount (embedding), surface mount, DIN rail mount*2 |
|||
Highest counting speed |
With contacts: 30 Hz, without contacts: 5 kHz (1:1 ON:OFF ratio) |
|||
Input signal |
No-voltage input (with contacts, without contacts [count input, inhibit input, reset input]) |
|||
Output |
Control output |
Maximum NPN open-collector output: 100 mA (40 V or less) |
||
Control output |
One-shot output time |
0.01 s to 0.5 s (variable) |
||
Relay |
15 ms or less (when set to 30 Hz), 3 ms or less (when set to 5 kHz) |
|||
DC output |
― |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Power consumption |
― |
|||
Current consumption |
150 mA or less |
|||
Environmental resistance |
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between all the external terminals and the case |
||
Noise resistance |
Square wave noise generated by a noise simulator, between the power supply terminals, 2 kV for 1 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Withstand voltage |
1,000 VAC for 1 minute (between all the external terminals and the case) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Weight |
Approx. 120 g (main unit only) |
|||
*1 Display uses the zero suppression method. | ||||

Specifications
Model |
CA-LHR35 |
|||
Focal point |
35 mm 1.38" |
|||
F-stop range (aperture) |
F2.0 to F16 |
|||
Minimum WD |
0.1 m 0.3' |
|||
Mount |
C-mount |
|||
Filter size |
34.0 mm 1.34" P0.5 |
|||
Compatible image sensor size |
2/3" |
|||
TV distortion |
0.05 % (-0.01 %)*1 |
|||
Resolving power |
200 cycles/mm at center, 140 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Lens coating |
WIDE, BAND MULTICOATING |
|||
Weight |
Approx. 160 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||

Specifications
Model |
OP-33155 |
|||
Type |
Screw Pipe Joint |
|||
Applicable product |
AP-41, AP-43, AP-44 |
|||
Cable end |
M5 male threads (2) and M5 male thread (1). |
|||

Specifications
Model |
OP-88395*1 |
|||
Material |
Nylon Zinc nickel plating |
|||
Weight |
Approx.12 g |
|||
*1 Use this when using a M12 connector type pressure sensor. | ||||

Specifications
Model |
OP-87627 |
|||
Number included |
1 |
|||
Cable end |
M8 straight - Loose wire |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: PVCConnector: Zinc nickel plating |
|||
Weight |
Approx. 60 g |
|||



Specifications
Model |
GL-SS2 |
|||
Type |
Standard cable |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
1 |
|||
Cable end |
Main unit connection connector - Main unit connection connector |
|||
Length |
2 m 6.56' |
|||
Note |
Use this with one-line systems and series connections. |
|||
Weight |
70 g |
|||

Specifications
Model |
OP-75722 |
|||
Type |
Connector Cable |
|||
Applicable product |
M12 connector sensor |
|||
Cable end |
Sensor side: M12 4-pin L-shape, Cable end: Loose wires |
|||
Length |
2 m 6.56' |
|||
Material |
PVC (Polyvinyl chloride) |
|||
Weight |
Approx. 65 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FD-G200 |
|||
Pipe size |
DN (Diameter Nominal) |
150 A, 200 A |
||
NPS (Nominal Pipe Size) |
6", 8" |
|||
Outer diameter of pipe |
ø163 to 171 mm 6.42" to 6.73", ø214 to 222 mm 8.43" to 8.74" |
|||
Pipe thickness |
3.5 to 8.7 mm 0.14" to 0.34" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||
Rated velocity of flow range |
Up to 15 m/s |
|||
Actual flow rate range (typical) |
m3/h |
Pipe size 150 A: 1000.0 |
||
L/min |
Pipe size 150 A: 17000 |
|||
CFM |
Pipe size 150 A: 600.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 150 A: 2842.15 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 150 A: 3603.18 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 150 A: 4364.21 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 150 A: 5125.24 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
Instantaneous flow rate |
0.1 m3/h, 1 L/min, 0.1 CFM |
||
Consumption/leakage amount |
0.1 m3, 1 L, 1 CF |
|||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||
Zero point error |
±0.15% of F.S.*2*6 |
|||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||
Hysteresis |
Variable |
|||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||
I/O wiring connection port |
M12 4-pin connector (male) |
|||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||
Communication interface |
USB |
USB 2.0 |
||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||
Connector |
M12 connector (female, D-code) |
|||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||
Events |
100 |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||
Relative humidity |
5 to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||
Mounting/damping bracket |
SUS304 |
|||
Weight |
Approx. 2.8 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. | ||||

Specifications
Model |
SV3-B020AK *1 |
|||
General specifications |
Applicable servo amplifier |
SV3-020L2 |
||
Rated output |
200 W |
|||
Rated torque |
0.637 N·m *2 |
|||
Instant maximum torque |
2.23 N·m |
|||
Rated current |
1.6 Arms |
|||
Instant maximum current |
5.8 Arms |
|||
Rated rotation speed |
3,000 min-1 |
|||
High rotation speed |
7,000 min-1 |
|||
Torque constant |
0.444 N·m/Arms |
|||
Rotor moment of inertia |
0.327 ×10-4 kg·m2 |
|||
Rated power rating |
12.4 kW/s |
|||
Rated angle acceleration |
19,400 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
26 bit |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20% to 80% RH (No condensation) |
|||
Operating atmosphere |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8 ft/s2 with servo motor flange surface as reference |
|||
Impact resistance |
490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: Class A, CE: Class B |
|||
Min. insulation resistance |
500 VDC 10 MΩ or more with insulation resistance meter |
|||
Isolation voltage tolerance |
1,500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
15×*3 |
|||
Approx. weight |
1.4 kg 3.09 lb |
|||
Electromagnetic brake specifications |
Capacity |
6 W |
||
Rated voltage |
24 VDC ±10% |
|||
Rated current (@20°C 68°F) |
0.25 A |
|||
Holding torque |
0.637 N·m |
|||
Release time |
60 ms |
|||
Operating time |
100 ms |
|||
*1 The open and operation times of the electromagnetic brake depend on the discharge circuit. | ||||

Specifications
Model |
MD-X1520 |
|||
Type |
Marking unit (controller + head) 25 W Wide area |
|||
2D code reader add-in (sold separately) |
MD-XAD1/MD-XAD1A |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-Axis simultaneous scanning method |
|||
Marking laser |
Type |
YVO4 laser, Class 4 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*1 |
||
Wavelength |
1,064 nm |
|||
Output |
25 W |
|||
Q-switch frequency |
CW (continuous wave), 1 to 400 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 Laser Product (IEC60825-1, JIS C6802, FDA [CDRH] part 1040.10)*1 |
|||
Marking area |
330 x 330 x 42 mm |
|||
Standard working distance (±variable width) |
300 mm (±21 mm) 11.81" (±0.83") |
|||
Marking resolution |
5 µm |
|||
Scan speed |
Max. 8,000 mm/s 314.96"/s |
|||
Character type |
Font |
KEYENCE original font (numbers, letters, katakana, hiragana, kanji), user font, TrueType font, OpenType font*2 |
||
Barcode |
CODE39, ITF, 2of5, NW7 (CODABAR), JAN, CODE128, EAN, UPC-A, UPC-E |
|||
2D code |
QR code, micro QR code, DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar, GS1 DataBar CC-A, GS1 DataBar Stacked, GS1 DataBar Stacked CC-A, GS1 DataBar Limited, |
|||
Logo image |
Custom character font and logo (CAD) data, BMP/JPEG/PNG/TIFF |
|||
Marking conditions |
Workpiece style |
Stationary marking, Moving marking (constant, encoder) |
||
Character size (marking height/width) |
0.1 to 330 mm 0.004" to 12.99" |
|||
No. of registered programs |
2,000 max. |
|||
No. of program blocks |
256 |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O, contactor control I/O*3 |
|||
Interface |
RS-232C, USB 2.0, Ethernet (100BASE-TX/10BASE-T)*4 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4.3 ±0.1 m 0.17" ±0.01" |
|||
Cooling method |
Forced air cooling |
|||
Rated voltage and power consumption |
100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, 800 VA max. |
|||
Environmental resistance |
Enclosure rating |
IP64 (marking head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 23.0 kg |
|||
*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice. | ||||

Specifications
Model |
SZ-VB03 |
|||
Type |
Mounting bracket |
|||
Applicable product |
SZ-V Series |
|||
Number included |
1 |
|||
Material |
SPHC |
|||
Note |
Accessories: M5 screw x 4 |
|||
Weight |
Approx. 1,350 g |
|||


Specifications
Model |
GL-R71F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
28.35" 720mm |
|||
No. of beam |
71 |
|||
Detection height |
27.56" 700mm |
|||
Protection height |
28.50" 724mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
12.1 |
|
OFF→ON |
56.9*2 |
|||
All blocked→ON |
85.2*3 |
|||
Optical synchronization system |
ON→OFF |
17.6 |
||
OFF→ON |
65.3*2 |
|||
All blocked→ON |
107.4*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
66 |
||
Receiver |
78 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1000 g |
||
Receiver |
1010 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.