
| Product | |
| Article Number (Market Facing Number) | 6GT28316CA50 | 6GT28316CA50 |
| Product Description | SIMATIC RF1000 Access Control Reader RF1040R; LF 125 kHz, HITAG 1/2/S, EM41xx, HF, ISO 14443 A/B, ISO15693; USB port, inc. RS 232 interface; IP65 front, -25 to +55 °C; 90 x 62 x 25 mm LxWxH; with integrated antenna, incl. 1.8 m USB connecting cable . |
| Product family | Not available |
| Product Lifecycle (PLM) | PM490:Start of final year of support |
| Additional Product Information | |
| EAN | 4034106026240 |
| UPC | 804766960741 |
| Commodity Code | 84718000 |
| LKZ_FDB/ CatalogID | ID10.M |
| Product Group | X0AI |
| Group Code | R322 |
| Country of origin | Germany |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 0.265 lb |
| Package size unit of measure | Inch |
| Packaging Quantity | 1 |


| Product | |
| Article Number (Market Facing Number) | 3RV20414RA15 | 3RV20414RA15 |
| Product Description | Circuit breaker size S3 for motor protection, CLASS 10 A-release 65...84 A N-release 1170 A screw terminal Standard switching capacity with transverse auxiliary switches 1 NO+1 NC |
| Product family | SIRIUS 3RV2 motor starter protectors |
| Product Lifecycle (PLM) | PM300:Active Product |
| Additional Product Information | |
| EAN | 4047621014142 |
| UPC | 804766798405 |
| Commodity Code | 85362090 |
| LKZ_FDB/ CatalogID | CC-IC10 |
| Product Group | 3673 |
| Group Code | R711 |
| Country of origin | Germany |
| SCIP number | Not available |
| Delivery information | |
| Net Weight (lb) | 5.011 lb |
| Package size unit of measure | Inch |
| Packaging Quantity | 1 |

This safety relay is designed for monitoring Emergency stop and Guard switch. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This basic safety modules embeds pre-defined safety functions. This safety relay embeds 1 control output, 4 NO safety outputs, and 2 NC diagnostic outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO13849-1, SILCL 3 conforming to IEC62061, SIL 3 conforming to IEC61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÃV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony Safety Automation |
| Product or Component Type | Safety module |
| Safety module name | XPSBAC |
| Safety module application | For emergency stop and protective guard applications |
| Function of module | Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches |
| Safety level | Can reach PL e/category 4 for normally open relay contact ISO 13849-1 Can reach SILCL 3 for normally open relay contact IEC 62061 Can reach SIL 3 for normally open relay contact IEC 61508 Can reach PL c/category 1 for normally closed relay contact ISO 13849-1 Can reach SILCL 1 for normally closed relay contact IEC 62061 Can reach SIL 1 for normally closed relay contact IEC 61508 |
| Safety reliability data | MTTFd > 30 years for normally open relay contact ISO 13849-1 Dcavg >= 99 % for normally open relay contact ISO 13849-1 PFHd = 0.95E-09 for normally open relay contact ISO 13849-1 HFT = 1 for normally open relay contact IEC 62061 PFHd = 0.95E-09 for normally open relay contact IEC 62061 SFF > 99% for normally open relay contact IEC 62061 HFT = 1 for normally open relay contact IEC 61508-1 PFHd = 0.95E-09 for normally open relay contact IEC 61508-1 SFF > 99% for normally open relay contact IEC 61508-1 Type = B for normally open relay contact IEC 61508-1 MTTFd > 30 years for normally closed relay contact ISO 13849-1 DC > 60 % for normally closed relay contact ISO 13849-1 PFHd = 0.95E-09 for normally closed relay contact ISO 13849-1 HFT=0 for normally closed relay contact IEC 62061 PFHd = 0.95E-09 for normally closed relay contact IEC 62061 SFF > 60% for normally closed relay contact IEC 62061 HFT=0 for normally closed relay contact IEC 61508-1 PFHd = 0.95E-09 for normally closed relay contact IEC 61508-1 SFF > 60% for normally closed relay contact IEC 61508-1 Type = B for normally closed relay contact IEC 61508-1 |
| Electrical circuit type | NC pair |
| Connections - terminals | Removable screw terminal block, 0.2...2.5 mm² solid or flexible Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel |
| [Us] Rated Supply Voltage | 24 V AC - 15...10 % 24 V DC - 20...20 % |
Complementary
| Characteristic | Value(s) |
|---|---|
| Synchronisation time between inputs | Unlimited |
| Type of start | Automatic/manual/monitored |
| Power consumption in W | 1.5 W 24 V DC |
| Power consumption in VA | 3.5 VA 24 V AC 50/60 Hz |
| Input protection type | Internal, electronic |
| safety outputs | 4 NO + 1 NC |
| safety inputs | 0 |
| Input compatibility | Normally closed circuit ISO 14119 XC limit switch ISO 14119 Mechanical contact ISO 14119 Normally closed circuit ISO 13850 |
| input terminal | Power supply |
| [Ie] rated operational current | 5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 3 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact |
| control outputs | 0 |
| [Ith] conventional free air thermal current | 6 A |
| Associated fuse rating | 10 A gG NO relay output circuit IEC 60947-1 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 5 V relay output |
| Response time | 150 ms at 24 V AC 80 ms at 24 V DC |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-1 |
| [Uimp] rated impulse withstand voltage | 4 kV II IEC 60947-1 |
| Local signalling | LED green power power ON LED red error error LED yellow state status LED yellow start1 start input LED yellow start2 start input |
| Mounting Support | 35 mm symmetrical DIN rail |
| Depth | 4.7 in (120 mm) |
| Height | 3.9 in (100 mm) |
| Width | 0.9 in (22.5 mm) |
| Product Weight | 0.441 lb(US) (0.200 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | Lexium 05 |
| Product or component type | Motion servo drive |
| Component name | LXM05A |
| Network number of phases | Three phase |
| power supply voltage | 380...480 V - 15...10 % |
| Continuous output current | 5 A at 8 kHz 6 A at 4 kHz |
| Nominal power | 1.4 kW at 4 kHz |
| Discrete input number | 2 safety discrete input(s) 4 logic discrete input(s) |
| Analogue input number | 2 |
| Type of polarization | Integrated and switchable impedances for CANopen No polarization impedances for Modbus |
Complementary
| Characteristic | Value(s) |
|---|---|
| power supply voltage limits | 323â¦528 V |
| Supply frequency | 50/60 Hz - 5...5 % |
| power supply frequency limits | 47.5â¦63 Hz |
| transient RMS output current | 10 A at 4 kHz for 3 s 7.5 A at 8 kHz for 3 s |
| Line current | 3.3 A at 480 V 4.2 A at 380 V |
| maximum prospective line Isc | 5 kA |
| Switching frequency | 8 kHz 4 kHz |
| Overvoltage category | III |
| Inrush current | 60 A |
| Maximum leakage current | 30 mA |
| Output voltage | <= power supply voltage |
| Insulation | Electrical between power and control |
| recommended type of cable for mounting in an enclosure | Single-strand IEC cable (temperature: 45 °C) copper 70 °C PVC Single-strand IEC cable (temperature: 45 °C) copper 90 °C XLPE/EPR |
| Electrical connection | Terminal, clamping capacity: 6 mm², AWG 10 (PA/+, PBI, PBe) Terminal, clamping capacity: 6 mm², AWG 10 (R/L1, S/L2, T/L3) |
| Tightening torque | PA/+, PBI, PBe: 1.2 N.m R/L1, S/L2, T/L3: 1.2 N.m |
| Discrete input type | Logic (LI1, LI2, LI3, LI4 terminals) Safety (PWRR_A, PWRR_B terminals) |
| Sampling duration | ANA1+/ANA1-, ANA2+/ANA2-: 0.25 ms analog LI1, LI2, LI3, LI4: 0.25 ms discrete |
| Discrete input voltage | 24 V DC for logic 24 V DC for safety |
| Discrete input logic | Negative (LI1, LI2, LI3, LI4) at State 0: > 19 V at State 1: < 9 V conforming to EN/IEC 61131-2 type 1 Positive logic (compliment of PWRR_A, compliment of PWRR_B) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1 Positive logic (LI1, LI2, LI3, LI4) at State 0: < 5 V at State 1: > 15 V conforming to EN/IEC 61131-2 type 1 |
| Response time | <= 10 ms |
| Discrete output number | 2 |
| Discrete output type | Logic output(s) (LO1, LO2)24 V DC |
| Discrete output voltage | <= 30 V DC |
| Discrete output logic | Negative (LO1, LO2) conforming to EN/IEC 61131-2 Positive (LO1, LO2) conforming to EN/IEC 61131-2 |
| Contact bounce time | 1 ms for LI1...LI4 |
| Braking current | 50 mA |
| Response time on output | 1 ms (LO1, LO2) for discrete output(s) |
| Absolute accuracy error | < +/- 1 % 25 °C < +/- 2 % over operating temperature range |
| Linearity error | < +/- 0.5 % |
| Analogue input type | ANA1+/ANA1-, ANA2+/ANA2- analog input: differential +/- 10 V, impedance: >= 10000 Ohm, resolution: 14 bits |
| Protection type | Inputs signal: against reverse polarity Outputs signal: against short-circuits |
| Safety function | PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2 PWR protection of the machine stop and/or prevent unintended operation of the servo motor conforming to ISO 13849-1 level d PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to EN/IEC 61508 level SIL2 PWR protection of the system process stop and/or prevent unintended operation of the servo motor conforming to IEC/EN 61800-5-2 |
| Communication port protocol | Modbus CANopen CANopen Motionbus |
| Connector type | RJ45 (labelled CN4) for CANopen, CANopen Motionbus RJ45 (labelled CN4) for Modbus Spring terminals (labelled CN1) for CANopen, CANopen Motionbus |
| Method of access | Slave CANopen, CANopen Motionbus |
| Physical interface | 2-wire RS485 multidrop Modbus RS422 for 1 A/B input(s), <= 400 kHz RS422 for 1 CW/CCW input(s), <= 400 kHz RS422 for 1 ESIM output input(s), <= 400 kHz RS422 for 1 P/D input(s), <= 400 kHz |
| Transmission rate | 50 kbps, 125 kbps, 250 kbps, 500 kbps, 1 Mbps for CANopen, CANopen Motionbus 9600, 19200, 38400 bps for Modbus |
| Data format | 8 bits, no parity, 1 or 2 stop for Modbus 8 bits, odd or even parity, 1 stop for Modbus |
| Number of addresses | 1â¦127 for CANopen, CANopen Motionbus 1â¦247 for Modbus |
| Communication service | 1 receive SDO + 1 transmit SDO for CANopen Motionbus 2 PDO for CANopen Motionbus 2 receive SDO + 2 transmit SDO for CANopen 3 PDO + 1 configurable mapping PDO for CANopen CiA DSP 402 profile for CANopen CiA DSP 402 profile for CANopen Motionbus Communication monitoring for Modbus Diagnostics (08) for Modbus Read device identification (43) for Modbus Read holding registers (03) for Modbus Read/write multiple registers (23) for Modbus Write multiple registers (16) for Modbus Write single register (06) for Modbus |
| diagnostics | Drive voltage: 1 LED (red) Error: 1 LED (CANopen) RUN: 1 LED (CANopen) |
| Signalling function | Display of faults integrated 7-segment display terminal |
| max nodes number | 31 for Modbus |
| Input resistance | 5 kOhm |
| Marking | CE |
| type of cooling | Fan |
| Operating position | Vertical +/- 10 degree |
| Product weight | 1.4 kg |

This Altistart 22 soft starter can feed 3-phase asynchronous motors in supply line connection. It has a rating of 75A, a rated power from 18.5kW to 45kW and a rated voltage from 230V to 500V AC. It is designed for simple and complex machines such as centrifugal and piston pumps, fans, screw compressors and material handling equipment. Slim form factor improves versatility; allows mounting in frames of any kind of machines. It features an Integrated bypass, this reduces noise and decreases heat dissipation. Compatibility with SoMove software allows configurations and settings to be easily transferred, meaning spares can be quickly installed. It provides smooth starting for your machinery, avoiding mechanical stresses and extending their service life.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Altistart 22 |
| Product or Component Type | Soft starter |
| Product destination | Asynchronous motors |
| Product Specific Application | Pumps and fans |
| Component name | ATS22 |
| Phase | 3 phase |
| [Us] rated supply voltage | 230...600 V - 15...10 % |
| Motor power kW | 37 kW 400 V 37 kW 440 V 18.5 kW 230 V 45 kW 500 V |
| Factory setting current | 65 A |
| Power dissipation in W | 63 W for standard applications |
| Utilisation category | AC-53A |
| Type of start | Start with torque control (current limited to 3.5 In) |
| IcL starter rating | 75 A connection in the motor supply line for standard applications |
| IP Degree of Protection | IP20 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Assembly style | With heat sink |
| Function Available | Internal bypass |
| Supply voltage limits | 195â¦660 V |
| Supply frequency | 50...60 Hz - 10...10 % |
| Network Frequency | 45...66 Hz |
| Device connection | In the motor supply line |
| [Uc] control circuit voltage | 230 V - 15...10 % 50/60 Hz |
| Control circuit consumption | 20 W |
| Discrete output number | 2 |
| Discrete output type | Relay outputs R1 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O Relay outputs R2 230 V running, alarm, trip, stopped, not stopped, starting, ready C/O |
| Minimum switching current | 100 mA 12 V DC relay outputs) |
| Maximum switching current | 5 A 250 V AC resistive 1 relay outputs 5 A 30 V DC resistive 1 relay outputs 2 A 250 V AC inductive 0.4 20 ms relay outputs 2 A 30 V DC inductive 7 ms relay outputs |
| Discrete input number | 3 |
| Discrete input type | LI1, LI2, LI3) logic, 5 mA 4.3 kOhm |
| Discrete input voltage | 24 V <= 30 V |
| Discrete input logic | Positive logic LI1, LI2, LI3 < 5 V <= 2 mA > 11 V, >= 5 mA |
| Output current | 0.4...1 Icl adjustable |
| PTC probe input | 750 Ohm |
| Communication Port Protocol | Modbus |
| Connector Type | 1 RJ45 |
| Communication data link | Serial |
| Physical interface | RS485 multidrop |
| Transmission Rate | 4800, 9600 or 19200 bps |
| Installed device | 31 |
| Protection type | Phase failure line Thermal protection motor Thermal protection starter |
| Marking | CE |
| type of cooling | Forced convection |
| Operating position | Vertical +/- 10 degree |
| Height | 11.6 in (295 mm) |
| Width | 5.7 in (145 mm) |
| Depth | 8.1 in (207 mm) |
| Product Weight | 26.5 lb(US) (12 kg) |
| Motor power range AC-3 | 30â¦50 kW 480â¦500 V 3 phase 15â¦25 kW 200â¦240 V 3 phase 30â¦50 kW 380â¦440 V 3 phase |
| Motor starter type | Soft starter |

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

This Harmony XB4, light block with body/fixing collar is red, operates with an integral LED. It has a metal body and is compatible with Harmony XB4 pilot lights. This light block allows fast and easy replacement and configuration of your signaling units. It is easily installed and replaced on compatible illuminated push button or selector switch units via clip together assembly and connected with simple screw-clamp connections. It enables visual distinction of signaling units via illumination by integral LED. It protects operators from unexpected contact with live circuits thanks to its IP20 protection index. It is designed to fit with a standard 22mm control and signaling units, ensuring compatibility when installing in pre-existing machinery. Its wide range of operating temperatures from -40°C to 55°C allows versatility in usage of product.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Harmony XB4 |
| Product or Component Type | Complete body/light block assembly |
| Device short name | ZB4 |
| Fixing collar material | Zamak |
| Sale per indivisible quantity | 1 |
| Connections - terminals | Screw clamp terminals, <= 2 x 1.5 mm² with cable end Screw clamp terminals, >= 1 x 0.22 mm² without cable end |
| Light source | Protected LED |
| Bulb base | Integral LED |
| Light source colour | Red |
| [Us] rated supply voltage | 24 V AC/DC 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| CAD overall width | 1.2 in (30 mm) |
| CAD overall height | 1.9 in (47 mm) |
| CAD overall depth | 1.5 in (37 mm) |
| Terminals description ISO n°1 | (X1-X2)PL |
| Product Weight | 0.119 lb(US) (0.054 kg) |
| Tightening torque | 7.08â¦10.6 lbf.in (0.8â¦1.2 N.m) EN 60947-1 |
| Shape of screw head | Cross Philips no 1 Cross pozidriv No 1 Slotted flat à 4 mm Slotted flat à 5.5 mm |
| [Ui] rated insulation voltage | 600 V 3)EN 60947-1 |
| [Uimp] rated impulse withstand voltage | 6 kV EN 60947-1 |
| Signalling type | Steady |
| Supply voltage limits | 19.2â¦30 V DC 21.6â¦26.4 V AC |
| Current Consumption | 18 mA |
| Service life | 100000 h at rated voltage and 25 °C |
| Surge withstand | 1 kV IEC 61000-4-5 |
| Device presentation | Basic sub-assemblies |

Altivar Soft Starter ATS480 is intended to start and stop asynchronous motors supplied from 208V to 690V. It meets the requirements of the most demanding applications in normal and heavy duty. With an operational rated current of 75A in normal duty, it supplies motor from 18,5kW to 55kW according to mains voltage. Designed for digitization, connected, optimized to meet cybersecurity standard, it simplifies project execution and maximizes the availability of applications. Its torque control (TCS) masters acceleration and deceleration. It efficiently stops high inertia application thanks to the dynamic braking and DC injection. It could be connected in-line or inside the delta to reduce its operational current. The embedded test routine simplifies the commissioning inside the delta. Its dimensions are 190mm (width) x 247mm (depth) x 290mm (height) and it weighs 8,3kg. Altivar Soft Starter ATS480 is designed to address process, infrastructures and industrial machines. It conforms to IEC/EN60947-4-1. It is certified CE, cULus, UKCA, CCC, RCM, EAC, and Marine certified DNV, ABS, BV and CCS. Display terminals, remote mounting kit, communication modules are common with Altivar Drives. Line chokes, DNV kits are common with ATS48. ATS480 is compatible with ATS48, it has same footprint, fixing, torque control algorithm, I/O, menus⦠The integration of Altivar Soft Starter ATS480 in EcoStruxure drastically simplifies architecture selection, detailed design and execution in automation and electrical systems.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Altivar Soft Starter ATS480 |
| Product or Component Type | Soft starter |
| Product destination | Asynchronous motors |
| Product Specific Application | Process and infrastructures |
| Device short name | ATS480 |
| Phase | 3 phase |
| Utilisation category | AC-3A AC-53A |
| Ue power supply voltage | 208...690 V - 15...10 % |
| power supply frequency | 50...60 Hz - 20...20 % |
| [Ie] rated operational current | Normal duty 75.0 A 104 °F (40 °C)) |
| rated current in heavy duty | 62.0 A at 104 °F (40 °C) heavy duty |
| Torque control | True |
| IP Degree of Protection | IP20 |
| Motor power kW | 18.5 kW 230 V in the motor supply line normal duty 15.0 kW 230 V in the motor supply line heavy duty 37.0 kW 400 V in the motor supply line normal duty 30.0 kW 400 V in the motor supply line heavy duty 37.0 kW 440 V in the motor supply line normal duty 30.0 kW 440 V in the motor supply line heavy duty 45.0 kW 500 V in the motor supply line normal duty 37.0 kW 500 V in the motor supply line heavy duty 45.0 kW 525 V in the motor supply line normal duty 37.0 kW 525 V in the motor supply line heavy duty 55.0 kW 660 V in the motor supply line normal duty 45.0 kW 660 V in the motor supply line heavy duty 55.0 kW 690 V in the motor supply line normal duty 45.0 kW 690 V in the motor supply line heavy duty 37.0 kW 230 V to the motor delta terminals normal duty 30.0 kW 230 V to the motor delta terminals heavy duty 55.0 kW 400 V to the motor delta terminals normal duty 55.0 kW 400 V to the motor delta terminals heavy duty |
| Maximum Horse Power Rating | 20.0 hp 208 V normal duty 15.0 hp 208 V heavy duty 25.0 hp 230 V normal duty 20.0 hp 230 V heavy duty 50.0 hp 460 V normal duty 40.0 hp 460 V heavy duty 60.0 hp 575 V normal duty 50.0 hp 575 V heavy duty |
| Option card | Communication module Profibus DP V1 Communication module Modbus TCP/EtherNet/IP Communication module CANopen daisy chain Communication module CANopen Sub-D Communication module CANopen open style Communication module PROFINET |
Complementary
| Characteristic | Value(s) |
|---|---|
| Device connection | In the motor supply line To the motor delta terminals |
| [Us] control circuit voltage | 110...230 V AC 50/60 Hz - 15...10 % |
| Apparent power | 0.09 kVA |
| Integrated motor overload protection | True |
| motor thermal protection class | Class 10E |
| Protection type | Phase failure line Integrated thermal protection motor Thermal protection starter Current overload motor Underload motor Excessive starting time, locked rotor motor Motor phase loss motor Line supply phase loss line Line supply phase loss motor Thermal protection motor |
| current limiting %In (5 x Ie maximum) | 150â¦700 % |
| [In] Rated current pwr loss specifctn | 75.0 A |
| Power loss static current independent | 25.0 W |
| Power loss per device current dependent | 225.0 W |
| Standards | IEC 60947-4-2 UL 60947-4-2 IEC 60664-1 |
| Product Certifications | CE cULus CCC UKCA RCM EAC DNV ABS BV CCS |
| Marking | CE CCC UKCA EAC RCM CULus |
| [Uc] control circuit voltage | 24 V DC |
| Discrete input number | 4 |
| Discrete input type | STOP) logic inputs, 3500 Ohm RUN) logic inputs, 3500 Ohm DI3) programmable as logic input, 3500 Ohm DI4) programmable as logic input, 3500 Ohm |
| Input compatibility | STOP discrete input level 1 PLC IEC 61131-2 RUN discrete input level 1 PLC IEC 61131-2 DI3 discrete input level 1 PLC IEC 61131-2 DI4 discrete input level 1 PLC IEC 61131-2 |
| Discrete input logic | Programmable digital input < 5 V |
| Relay output number | 3 |
| Relay output type | Relay outputs R1A 1 NO Relay outputs R1B 1 NO Relay outputs RIC NO/NC programmable |
| Minimum switching current | 100 mA 12 V DC relay outputs |
| Maximum switching current | Relay outputs 2 A 250 V AC Relay outputs 2 A 30 V DC |
| Discrete output number | 2 |
| Discrete output type | DQ1) programmable digital output <= 30 V DQ2) programmable digital output <= 30 V |
| Output compatibility | Open collector level 1 PLC IEC 65A-68 |
| Analogue input number | 1 |
| Analogue input type | AI1/PTC PTC/Pt 100 temperature probe PTC2 PTC/Pt 100 temperature probe PTC3 PTC/Pt 100 temperature probe |
| Analogue output number | 1 |
| Analogue output type | Current output AQ1 0...20 mA or 0...10 V 500 Ohm |
| Communication Port Protocol | Modbus serial |
| Connector Type | 1 RJ45 |
| Communication data link | Serial |
| Physical interface | 2-wire RS 485 |
| Transmission Rate | 1200...256000 bit/s |
| Transmission frame | RTU |
| Data format | 8 bits, configurable odd, even or no parity |
| Type of polarization | No impedance Modbus serial |
| Number of addresses | 0â¦227 Modbus serial |
| Method of access | Slave Modbus serial |
| Function Available | External bypass control Pre-heating Smoke extraction Multi-motor cascade Second motor set User management Ports and services hardening Security event logging Cybersecure firmware update Single direction |
| Display screen available | True |
| Operating position | Vertical +/- 10 degree |
| Height | 11.4 in (290.0 mm) |
| Width | 7.5 in (190.0 mm) |
| Depth | 9.7 in (247.0 mm) |
| Product Weight | 18.3 lb(US) (8.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Modicon M238 logic controller |
| Product or Component Type | I/O expansion module |
| Analogue input number | 4 |
| Input level | High level |
| Analogue input type | current 4...20 mA non differential voltage 0...10 V non differential |
| Analogue output number | 2 |
| Analogue output type | Current 4...20 mA Voltage 0...10 V |
| Cross talk | <= 2 LSB |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range Compatibility | Twido Advantys OTB |
| Analogue input resolution | 12 bits |
| Analogue output resolution | 12 bits |
| LSB value | 2.5 mV voltage voltage 4 µA current current |
| Permissible continuous overload | 40 mA current 13 V voltage |
| Input impedance | >= 1 Ohm voltage <= 250 MOhm current |
| Load type | Resistive |
| Load impedance ohmic | >= 2000 Ohm voltage <= 300 Ohm current |
| Stabilisation time | 20 ms |
| Conversion time | 20 ms + 1 controller cycle time |
| Sampling duration | 16 ms |
| Acquisition period | 16 ms per channel + 1 controller cycle time |
| Measurement error | +/- 0.5 % of full scale 0...10 V 25 °C +/- 0.5 % of full scale 4...20 mA 25 °C +/- 0.9 % of full scale 0...10 V 25 °C +/- 0.9 % of full scale 4...20 mA 25 °C |
| Temperature coefficient | +/- 0.02 %FS/°C 0...10 V +/- 0.02 %FS/°C 4...20 mA +/-0.015 %FS/°C 0...10 V 0...10 V +/-0.015 %FS/°C 4...20 mA 4...20 mA |
| Repeat accuracy | +/- 1 %FS output +/-0.5 %FS input |
| Non-linearity | +/- 0.4 %FS current +/- 0.4 %FS voltage +/- 0.5 %FS current +/- 0.5 %FS voltage |
| Output error | +/- 1 %FS |
| Output ripple | <= 1 LSB |
| Total error | +/- 1.5 %FS current +/- 1.5 %FS voltage +/-1 %FS current current +/-1 %FS voltage voltage |
| Type of Cable | Shielded cable |
| Insulation between channel and internal logic | Photocoupler |
| Supply | External supply |
| [Us] rated supply voltage | 24 V DC |
| Supply voltage limits | 19.2â¦30 V |
| Electrical connection | 1 removable screw terminal block |
| Current consumption | 60 mA 5 V DC internal 80 mA 24 V DC external |
| Product Weight | 0.187 lb(US) (0.085 kg) |














