Drives - Motors - Circuits Protection

1561 products

Showing 169 - 192 of 1561 products

Showing 169 - 192 of 1561 products
View
E3N2500PR122/P-LSIIn=2500A3pWMP ABB - 1SDA056132R1

E3N2500PR122/P-LSIIn=2500A3pWMP,SACE EMAX MOVING PART FOR CIRCUIT-BREAKER E3N 2500A THRE-POLE OVERCURRENT RELEASE PR122/P-LSI R2500 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

1SDA056136R1 ABB
ABB 1SDA056136R1 ABB
Sale price$0.00
Sold Out

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644574765
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
558 mm
Product Net Height:
461 mm
Product Net Depth / Length:
396.5 mm
Product Net Weight:
81 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
785 mm
Package Level 1 Gross Weight:
96 kg
Package Level 1 EAN:
8015644574765

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
350 W
Rated Current (In):
2500 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
2500 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 65 kA
for 3 s 65 kA
for 1 s 65 kA
for 3 s 65 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
Rated Uninterrupted Current (Iu):
2500 A
Rated Voltage (Ur):
690 V
Release:
PR121/P-LI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E3
Terminal Connection Type:
Withdrawable Circuit-Breakers

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)
E3N2500PR121/P-LSIGIn=2500A3pWMP ABB - 1SDA056130R1

E3N2500PR121/P-LSIGIn=2500A3pWMP, SACE EMAX MOVING PART FOR CIRCUIT-BREAKER E3N 2500A THRE-POLE OVERCURRENT RELEASE PR121/P-LSIG R2500 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

1SDA056140R1 ABB
ABB 1SDA056140R1 ABB
Sale price$0.00
Sold Out

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644574802
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
558 mm
Product Net Height:
461 mm
Product Net Depth / Length:
396.5 mm
Product Net Weight:
81 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
785 mm
Package Level 1 Gross Weight:
96 kg
Package Level 1 EAN:
8015644574802

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 7000 cycle
20 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
350 W
Rated Current (In):
2500 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
2500 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 65 kA
for 3 s 65 kA
for 1 s 65 kA
for 3 s 65 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
Rated Uninterrupted Current (Iu):
2500 A
Rated Voltage (Ur):
690 V
Release:
PR122/P-LSI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E3
Terminal Connection Type:
Withdrawable Circuit-Breakers

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)
E3N2500PR122/P-LIIn=2500A3pWMP ABB - 1SDA056131R1

E3N2500PR122/P-LIIn=2500A3pWMP, SACE EMAX MOVING PART FOR CIRCUIT-BREAKER E3N 2500A THRE-POLE OVERCURRENT RELEASE PR122/P-LI R2500 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

E3N2500PR121/P-LSIGIn=2500A4pWMP ABB - 1SDA056138R1

E3N2500PR121/P-LSIGIn=2500A4pWMP, SACE EMAX MOVING PART FOR CIRCUIT-BREAKER E3N 2500A FOUR-POLE OVERCURRENT RELEASE PR121/P-LSIG R2500 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

E3N2500PR121/P-LIIn=2500A3pWMP ABB - 1SDA056128R1

E3N2500PR121/P-LIIn=2500A3pWMP, SACE EMAX MOVING PART FOR CIRCUIT-BREAKER E3N 2500A THRE-POLE OVERCURRENT RELEASE PR121/P-LI R2500 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

E3N2500PR122/P-LIIn=2500A4pFHR ABB - 1SDA056123R1

E3N2500PR122/P-LIIn=2500A4pFHR, SACE EMAX CIRCUIT-BREAKER E3N 2500A FOUR-POLE FIXED WITH TERMINALS REAR HORIZONTAL OVERCURRENT RELEASE PR122/P-LI R2500 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

E3N2500PR121/P-LSIIn=2500A4pWMP ABB - 1SDA056137R1

E3N2500PR121/P-LSIIn=2500A4pWMP, SACE EMAX MOVING PART FOR CIRCUIT-BREAKER E3N 2500A FOUR-POLE OVERCURRENT RELEASE PR121/P-LSI R2500 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

E3N3200PR121/P-LIIn=3200A3pFHR ABB - 1SDA056144R1

E3N3200PR121/P-LIIn=3200A3pFHR, SACE EMAX CIRCUIT-BREAKER E3N 3200A THRE-POLE FIXED WITH TERMINALS REAR HORIZONTAL OVERCURRENT RELEASE PR121/P-LI R3200 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED

E2N2000PR121/P-LSIGIn=2000A3pFHR ABB - 1SDA055922R1

E2N 2000 PR121/P-LSIG In=2000A 3p F HR

E2N1600PR121/P-LSIGIn=1600A4pWMP ABB - 1SDA055914R1

E2N 1600 PR121/P-LSIG In=1600A 4p W MP

E2N1600PR122/P-LIIn=1600A3pWMP ABB - 1SDA055907R1

E2N 1600 PR122/P-LI In=1600A 3p W MP

E2S1250PR121/P-LIIn=1250A4pFHR ABB - 1SDA055960R1

E2S 1250 PR121/P-LI In=1250A 4p F HR

E2S1250PR121/P-LSIGIn=1250A3pFHR ABB - 1SDA055954R1

E2S 1250 PR121/P-LSIG In=1250A 3p F HR

E2N1600PR122/P-LIIn=1600A4pWMP ABB - 1SDA055915R1

E2N 1600 PR122/P-LI IN=1600A 4P W MP

E2S2000PR122/P-LSIIn=2000A4pFHR ABB - 1SDA056028R1

E2S 2000 PR122/P-LSI In=2000A 4p F HR

E2N1600PR121/P-LSIIn=1600A3pWMP ABB - 1SDA055905R1

E2N 1600 PR121/P-LSI In=1600A 3p W MP

E2N1600PR121/P-LSIIn=1600A4pWMP ABB - 1SDA055913R1

E2N 1600 PR121/P-LSI In=1600A 4p W MP

E2N1600PR121/P-LSIGIn=1600A3pWMP ABB - 1SDA055906R1

E2N 1600 PR121/P-LSIG IN=1600A 3P W MP

E2N2000PR121/P-LSIIn=2000A4pWMP ABB - 1SDA055945R1

E2N 2000 PR121/P-LSI In=2000A 4p W MP

1SDA055978R1 ABB - E2S1250PR121/P-LSIGIn=1250A4pWMP

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644573188
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
414 mm
Product Net Height:
461 mm
Product Net Depth / Length:
396.5 mm
Product Net Weight:
61 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
73 kg
Package Level 1 EAN:
8015644573188

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
130 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
1250 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 65 kA
for 3 s 50 kA
for 1 s 65 kA
for 3 s 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
Rated Uninterrupted Current (Iu):
1250 A
Rated Voltage (Ur):
690 V
Release:
PR121/P-LSIG
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC
Sub-type:
E2
Terminal Connection Type:
Withdrawable Circuit-Breakers

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
1SDA055912R1 ABB - E2N1600PR121/P-LIIn=1600A4pWMP

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644572525
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
414 mm
Product Net Height:
461 mm
Product Net Depth / Length:
396.5 mm
Product Net Weight:
61 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
73 kg
Package Level 1 EAN:
8015644572525

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
215 W
Rated Current (In):
1600 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
1600 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
Rated Uninterrupted Current (Iu):
1600 A
Rated Voltage (Ur):
690 V
Release:
PR121/P-LI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E2
Terminal Connection Type:
Withdrawable Circuit-Breakers

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
E2S1250PR121/P-LIIn=1250A3pFHR ABB - 1SDA055952R1

E2S 1250 PR121/P-LI IN=1250A 3P F HR

Recently viewed