This Acti9 iTLs is a modular impulse relay. This 1P device has 1 normally open contact. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 48VAC or 24VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 100 switching operations/day or 5 switching operations/minute. The duration of the command order should be between 50ms to 1s. It is mainly used for lighting control applications. This impulse relays allow remote indication of their operating state. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 18mm x (H) 84mm x (D) 60mm. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -20°C to 50°C. The storage temperature is from -40°C to 70°C. This product is compliant with IEC/EN 60669-1 and IEC/EN 60669-2-2 standard.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iTL |
| Product or component type | Impulse relay |
| Device short name | iTLs |
| Device application | Remote indication |
| Poles | 1P |
| Pole contact composition | 1 NO |
| Auxiliary contact composition | 1 C/O |
| [In] rated current | 16 A |
| Network type | AC |
| [Uc] control circuit voltage | 48 V AC 50/60 Hz 24 V DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 250 V AC 50/60 Hz |
| control type | Remote and manual control Coil deconnection |
| Control signal type | Impulse |
| Switching frequency | 100 switching operations/day 5 switching operations/minute |
| Impulse duration | 50 ms...1 s |
| Remote control type | Illuminated push-button 3 mA |
| Local signalling | ON/OFF indication |
| Signalling circuit voltage | AC: 24...240 V DC: 24...240 V |
| Signalling output current | 0.01...6 A |
| Mounting mode | Fixed |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 84 mm |
| Width | 18 mm |
| Depth | 60 mm |
| Electrical durability | AC-21: 200000 cycles AC-22: 100000 cycles |
| Connections - terminals | Control circuit: tunnel type terminals 1 cable(s) 0.5â¦4 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 0.5â¦4 mm² rigid with cable end Control circuit: tunnel type terminals 1 cable(s) 1â¦4 mm² flexible Control circuit: tunnel type terminals 1 cable(s) 1â¦4 mm² flexible with ferrule Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² rigid Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² rigid with cable end Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² flexible Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² flexible with ferrule |
| Wire stripping length | 11 mm |
| Tightening torque | 1 N.m |
| Range compatibility | Acti9 iATEt Acti9 iATLc Acti9 iATLc+s Acti9 iATLm Acti9 iATLs Acti9 iETL iTL 16 Acti9 iATLc+c |

Main
| Characteristic | Value(s) |
|---|---|
| Device application | Distribution Control |
| Range | Acti9 |
| product name | Reflex iC60 |
| Device short name | Reflex iC60N |
| Product or component type | Integrated control circuit breaker |
| Poles description | 2P |
| Number of protected poles | 2 |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | B |
Complementary
| Characteristic | Value(s) |
|---|---|
| [In] rated current | 63 A |
| Network frequency | 50/60 Hz |
| Breaking capacity code | N |
| Breaking capacity | 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Ui] rated insulation voltage | 500 V AC |
| Contact position indicator | Yes |
| control type | Remote control by pulse ON/OFF button Remote control by continuous command Toggle |
| Control signal type | Maintained very low voltage Maintained Impulse |
| Local signalling | Green LED: device ON Red LED: fault Flashing LED: device overheat Flashing LED: device tripped Flashing LED: device ready |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz 24 V AC 50/60 Hz 48 V AC 50/60 Hz 24 V DC 48 V DC |
| [Us] rated supply voltage | 230 V AC at 50/60 Hz |
| Mounting mode | Fixed |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 9 |
| Height | 84 mm |
| Width | 81 mm |
| Depth | 77 mm |
| Colour | White |
| Mechanical durability | 50000 cycles |
| Electrical durability | AC-1: 50000 cycles AC 50 Hz |
| Provision for padlocking | Padlockable |
| Locking options description | Padlock in OFF position |
| Earth-leakage protection | Separate block |
| Product compatibility | With PLC |

This Acti9 iQuick PRD40r surge arrester protects 3P+N residential and larger buildings installations against indirect transient overvoltages. This Type 2 device autoprotected by an integrated circuit-breaker is recommanded for high risk level in incoming panel board. It offers remote reporting of the "cartridge must be changed" message. This prewired surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It incorporates its end of life safety disconnector. The Isc integrated breaking capacity is 20kA. This Acti9 iQuick PRD40r is compatible with TT and TN-S earthing system. The Imax maximum discharge current is 40kA. The In nominal discharge current is 20kA. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in common mode is 264VAC between neutral and earth, and is 350VAC between phase and earth. The Up voltage protection level in differential mode (between phase and neutral) is below or equal to 2.5kV. The Up Voltage protection level in common mode is below or equal to 1.5kV between phase and earth, or neutral and earth. The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 131.5mm x (H) 103.8mm x (D) 75.9mm. The width in 9mm pitches is 15. The weight is 850g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product complies with IEC/EN 60947-5-1 and EN 61643-11: 2012 Type 2, IEC 61643-11: 2011 T2 standards.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | IQuick PRD |
| range of product | Acti9 |
| product name | Acti9 iQuick PRD |
| Product or component type | Surge arrester with pluggable cartridge |
| Device short name | iQuick PRD40r |
| Device application | Distribution |
| Standards | EN 61643-11:2012 IEC 61643-11:2011 |
| Product certifications | CE |
| Quality labels | KEMA-KEUR NF |
| Poles description | 3P + N |
| Remote signalling | With |
| Signal contacts composition | 1 SD (1 C/O) |
| Surge arrester type | Electrical distribution network |
| Earthing system | TN-S TT |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 |
| Surge arrester technology | MOV + GDT |
| [Ue] rated operational voltage | 230/400 V AC (+/- 10 %) at 50/60 Hz |
| Nominal discharge current | Common mode: 20 kA (L/PE) Common mode: 20 kA (N/PE) Differential mode: 20 kA (L/N) |
| Maximum discharge current | Common mode: 40 kA L/PE Common mode: 40 kA N/PE Differential mode: 40 kA L/N |
| [Uc] maximum continuous operating voltage | Common mode: 264 V N/PE Common mode: 350 V L/PE Differential mode: 350 V L/N |
| Maximum [Up] voltage protection level | Common mode <1.5 kV type 2 L/PE Common mode <1.5 kV type 2 N/PE Differential mode <2.5 kV type 2 L/N |
| Disconnector device type | Integrated circuit breaker - Icu 20 kA |
| Signalling circuit voltage | 2 A/250 V AC 50/60 Hz |
| Mounting mode | Clip-on (DIN rail) |
| 9 mm pitches | 14.7 |
| Height | 94 mm |
| Width | 131.5 mm |
| Depth | 75.9 mm |
| Product weight | 0.86 kg |
| Colour | White (RAL 9003) |
| Connections - terminals | Tunnel type terminal (upside) 2.5â¦35 mm² Tunnel type terminal (downside) 2.5â¦25 mm² |
| Tightening torque | 2.5 N.m |
| Compatibility code | IQuick PRD40r |

This Acti9 C120N is a low voltage multistandard miniature circuit breaker (MCB). It is a 2P circuit breaker with 2 protected poles, 125A rated current and C tripping curve. The Icn rated short circuit breaking capacity is up to 10000A at 230VAC to 400VAC conforming to IEC/EN 60898-1 standard. This product complies with industrial standard IEC/EN 60898-1 and residential standard IEC/EN 60947-2. This miniature circuit breaker protects circuit against short circuit and overload current. The presence of green strip guarantees contact open physically and allows work to be carried out safely on the downstream circuit. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is going from 380VAC to 415VAC. The Ui rated insulation voltage is 500VAC. Its limitation class 3 (according to IEC/EN 60947-2 standard) improves downstream circuit protection cost. The product can be clipped on a DIN rail. Its width is 6 pitches of 9mm. Pollution degree is 3. Overvoltage category is IV. The product colour is white (RAL 9003). The dimensions are (W) 54mm x (H) 81mm x (D) 73mm. The weight is 0.41kg. It has an IP20 degree of protection (as per IEC 60529 standard) on its terminals. The operating temperature is from -25°C to +70°C. The storage temperature is from -40°C to +85°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| product name | Acti9 C120 |
| Product or component type | Miniature circuit-breaker |
| Device short name | C120N |
| Device application | Distribution |
| Poles description | 2P |
| Number of protected poles | 2 |
| Neutral position | Left |
| [In] rated current | 125 A at 30 °C |
| Network type | AC |
| Trip unit technology | Thermal-magnetic |
| Curve code | C |
| Breaking capacity | 10000 A Icn at 230...400 V AC 50/60 Hz conforming to EN/IEC 60898-1 6 kA Icu at 440 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at <= 250 V DC conforming to EN/IEC 60947-2 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2 10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-2 |
| Standards | EN/IEC 60947-2 EN/IEC 60898-1 |
| Product certifications | EAC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 380...415 V AC 50/60 Hz 220...240 V AC 50/60 Hz 440 V AC 50/60 Hz <= 250 V DC 230...400 V AC 50/60 Hz |
| Magnetic tripping limit | 5...10 x In |
| [Ics] rated service breaking capacity | 7500 A 75 % conforming to EN/IEC 60898-1 - 230...400 V AC 50/60 Hz 4.5 kA 75 % conforming to EN/IEC 60947-2 - 440 V AC 50/60 Hz 7.5 kA 75 % conforming to EN/IEC 60947-2 - 380...415 V AC 50/60 Hz 15 kA 75 % conforming to EN/IEC 60947-2 - 220...240 V AC 50/60 Hz 10 kA 100 % conforming to EN/IEC 60947-2 - <= 250 V DC |
| Limitation class | 3 conforming to EN/IEC 60947-2 |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz conforming to EN/IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to EN/IEC 60947-2 |
| Contact position indicator | Yes |
| control type | Toggle |
| Local signalling | ON/OFF indication |
| Mounting mode | Clip-on |
| Mounting support | 35 mm symmetrical DIN rail |
| Comb busbar and distribution block compatibility | YES |
| 9 mm pitches | 6 |
| Height | 81 mm |
| Depth | 73 mm |
| Width | 54 mm |
| Product weight | 0.41 kg |
| Colour | White |
| Mechanical durability | 20000 cycles |
| Electrical durability | 5000 cycles conforming to IEC 60947-2 |
| Locking options description | Handle sealable with cable diameter 0.7mm in OFF or ON position |
| Connections - terminals | Tunnel type terminals1â¦50 mm² rigid Tunnel type terminals1.5â¦35 mm² flexible |
| Wire stripping length | 15 mm |
| Tightening torque | 3.5 N.m |
| Earth-leakage protection | Separate block |

This Acti9 iPRD40 surge arrester protects 3P installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level and incoming panel board. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode (between phase and earth) is 350VAC. The Up maximum voltage protection level in common mode (between phase and earth) is 1.4kV. The Ue rated operational voltage is 230VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The weight is 317g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | IPRD |
| range of product | Acti9 |
| product name | Acti9 iPRD |
| Product or component type | Surge arrester with pluggable cartridge |
| Device short name | iPRD40 |
| Device application | Distribution |
| Standards | EN 61643-11:2012 IEC 61643-11:2011 |
| Product certifications | CE |
| Quality labels | KEMA-KEUR NF |
| Poles description | 3P |
| Remote signalling | Without |
| Surge arrester type | Electrical distribution network |
| Earthing system | TN-C IT 230 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 |
| Surge arrester technology | MOV |
| [Ue] rated operational voltage | 400 V AC (+/- 10 %) at 50/60 Hz |
| Nominal discharge current | Common mode: 15 kA (L/PE) Common mode: 15 kA (N/PE) |
| Maximum discharge current | Common mode: 40 kA L/PE |
| [Uc] maximum continuous operating voltage | Common mode: 350 V L/PE |
| Maximum [Up] voltage protection level | Common mode <1.4 kV type 2 L/PE |
| [Ut] temporary overvoltage | 337 V L/N 5 s withstand 1200 V N/PE 200 ms safe failure mode |
| Disconnector device type | Associated circuit breaker iC60H 40 A curve C - Icu 15 kA Associated circuit breaker IC60N 40 A curve C - Icu 10 kA Associated circuit breaker NG125H 40 A curve C - Icu 36 kA Associated circuit breaker NG125L 40 A curve C - Icu 50 kA Associated circuit breaker NG125N 40 A curve C - Icu 25 kA Associated fuse gG 63 A - Icu 15 kA Associated fuse gG 80 A - Icu 50 kA |
| Mounting mode | Clip-on (DIN rail) |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 69 mm |
| Product weight | 0.317 kg |
| Colour | White (RAL 9003) |
| [Ipe] Ground residual current | 0.003 mA 0.6 mA |
| Connections - terminals | Tunnel type terminal (downside) 2.5â¦35 mm² Tunnel type terminal (upside) 2.5â¦35 mm² |
| Tightening torque | 2.5 N.m |
| Compatibility code | IPRD40 |

This Acti9 iPRD-DC 40r direct current surge arresters protects 2P photovoltaic installations. It allows quick replacement of damaged cartridges. The Iscpv short circuit breaking capacity is 200A. The Itotal discharge current is 40kA. The In nominal discharge current is 15kA. This Type 2 device is recommended to protect against indirect lightning strikes. The surge arresters with r indication have remote transfer of the information Cartridge to be replaced. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The Uc maximum continuous operating voltage is 1000VDC. The Up protection level is 3.9kV in differential mode and in common mode. The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 4. The weight is 400g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product complies with UTE C 61470-51 and EN 50539-11:2013 standards.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iPRD PV-DC |
| Device short name | iPRD PV-DC |
| Product or component type | Surge arrester with pluggable cartridge |
| Poles description | 2P |
| Output type | Contact (volt-free) |
| Signal contacts composition | 1 SD (1 C/O) |
| Surge arrester type | Electrical distribution network |
| Uoc stc: Maximum open circuit voltage of PV generator in standard test condition | 833 V |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 |
| Surge arrester technology | MOV |
| [Ue] rated operational voltage | 1000 V +/- 10 % DC |
| [In] nominal discharge current | 15 kA |
| [Imax] maximum discharge current | 40 kA |
| [Ucpv] maximum continuous operating voltage | Differential mode: 1000 V L+/L- Common mode: 1000 V L+/PE Common mode: 1000 V L-/PE |
| Maximum [Up] voltage protection level | Common mode <3.9 kV type 2 L+/PE Common mode <3.9 kV type 2 L-/PE Differential mode <3.9 kV type 2 L+/L- |
| Disconnector device type | Integrated disconnector |
| [Iscpv] short-circuit current rating | 200 A |
| Local signalling | White/red flag |
| Signalling circuit voltage | AC: 250 V 50/60 Hz |
| Signalling output current | 0.25 A |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 69 mm |
| Product weight | 400 g |
| Colour | White (RAL 9003) |
| Response time | <= 25 ns |
| Connections - terminals | Tunnel type terminal 2.5â¦25 mm² rigid Tunnel type terminal 2.5â¦16 mm² flexible Tunnel terminal 2.5â¦16 mm² flexible with ferrule |
| Wire stripping length | 14 mm |
| Tightening torque | 3.5 N.m |

This Acti9 iPRD40 surge arrester protects 1P+N installations. It allows quick replacement of damaged cartridges. Modular design (cartridge type) DIN rail mounted The associated circuit breaker Isc breaking capacity can go up to 50kA. This Acti9 iPRD40 is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode is 260VAC between neutral and earth, and 350VAC between phase and earth. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Up Voltage protection level is 1.4kV in common mode (N/PE) and in differential mode (L/N). The Ue rated operational voltage is 230VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 36mm x (H) 85mm x (D) 69mm. The weight is 0.211kg. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standard.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | IPRD |
| range of product | Acti9 |
| product name | Acti9 iPRD |
| Product or component type | Surge arrester with pluggable cartridge |
| Device short name | iPRD40 |
| Device application | Distribution |
| Standards | EN 61643-11:2012 IEC 61643-11:2011 |
| Product certifications | CE |
| Quality labels | KEMA-KEUR NF |
| Poles description | 1P + N |
| Remote signalling | Without |
| Surge arrester type | Electrical distribution network |
| Earthing system | TN-S TT |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 |
| Surge arrester technology | MOV + GDT |
| [Ue] rated operational voltage | 230 V AC (+/- 10 %) at 50/60 Hz |
| Nominal discharge current | Common mode: 15 kA (L/PE) Common mode: 15 kA (N/PE) Differential mode: 15 kA (L/N) |
| Maximum discharge current | Common mode: 40 kA L/PE Common mode: 40 kA N/PE Differential mode: 40 kA L/N |
| [Uc] maximum continuous operating voltage | Common mode: 260 V N/PE Common mode: 350 V L/PE Differential mode: 350 V L/N |
| Maximum [Up] voltage protection level | Common mode <1.4 kV type 2 N/PE Differential mode <1.4 kV type 2 L/N |
| [Ut] temporary overvoltage | 337 V L/N 5 s withstand 1200 V N/PE 200 ms safe failure mode 442 V L/PE 5 s withstand 1453 V L/PE 200 ms safe failure mode |
| Disconnector device type | Associated circuit breaker iC60H 40 A curve C - Icu 15 kA Associated circuit breaker IC60N 40 A curve C - Icu 10 kA Associated circuit breaker NG125H 40 A curve C - Icu 36 kA Associated circuit breaker NG125L 40 A curve C - Icu 50 kA Associated circuit breaker NG125N 40 A curve C - Icu 25 kA Associated fuse gG 63 A - Icu 15 kA Associated fuse gG 80 A - Icu 50 kA |
| Mounting mode | Clip-on (DIN rail) |
| 9 mm pitches | 4 |
| Height | 85 mm |
| Width | 36 mm |
| Depth | 69 mm |
| Product weight | 0.211 kg |
| Colour | White (RAL 9003) |
| [Ipe] Ground residual current | 0.6 mA 0.003 mA |
| Connections - terminals | Tunnel type terminal (downside) 2.5â¦35 mm² Tunnel type terminal (upside) 2.5â¦35 mm² |
| Tightening torque | 2.5 N.m |
| Compatibility code | IPRD40 |

This PowerTag Energy F63 1P+N 110V is a wireless communication energy sensor. With its Flex design, it is dedicated to 3P+N devices, rating less than or equal 63A. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. The Performance category is Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage are Phase-to-neutral 220VAC to 240VAC +/- 20% and Phase-to-phase 380VAC to 415VAC +/- 20%. The maximum consumption is below or equal to 2VA. It can be either mounted on the top or the bottom of the protective device. The product color is white (RAL9003). The weight is 40g. The degree of protection is IP20 and IK05 The operating temperature is between -25°C to +60°C. The Storage temperature is between -40°C to +85°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | PowerLogic |
| product name | PowerTag A9 F63 |
| Product or component type | Energy sensor |
| Poles | 3P + N |
| Maximum current [Imax] | 63 A |
| [Ib] Basic current | 10 A |
| Starting current | 40 mA |
| Saturation current | 130 A |
| Product specific application | Cost allocation Load monitoring Overload alarm Circuit monitoring Energy management |
| Concentrator compatibility | Acti9 Smartlink SI B Acti9 Smartlink SI D Acti9 PowerTag Link C Acti9 PowerTag Link Acti9 PowerTag Link HD Harmony Hub Wiser IP module EcoStruxure Panel Server Universal EcoStruxure Panel Server Advanced PrismaSet Active |
| Application | Buildings: breaker voltage monitoring Buildings: cost allocation Buildings: overload alarm |
| Range compatibility | Acti 9 Vigi DT40 Acti 9 Vigi iC40 Acti 9 Vigi iDT40 Acti 9 Vigi N40 Acti 9 Vigi C40 Acti 9 Vigi iC60 Acti 9 Acti9 iDD40 Acti 9 Acti9 iDD40 XA Acti 9 Acti9 iCV40 XA Acti 9 Vigi iDPN Acti 9 Acti9 iCV40 Acti 9 Vigi iTG40 Acti 9 Vigi iCG40 |
| Type of measurement | Voltage Active energy Active power Current Power factor |
| Accuracy class | Class 1 current conforming to IEC 61557-12 Class 0.5 voltage conforming to IEC 61557-12 Class 1 active power conforming to IEC 61557-12 Class 1 active energy conforming to IEC 61557-12 Class 1 power factor conforming to IEC 61557-12 |
| Mounting location | Top or bottom |
| Mounting support | On circuit breaker |
| Product destination | Switchboard |
| Event management | Voltage loss with measured current at voltage loss |
| Transmission support medium | Radio frequency 2.4â¦2.4835 GHz conforming to IEEE 802.15.4 |
| Emission power | 10 mW |
Complementary
| Characteristic | Value(s) |
|---|---|
| Form factor | Flex |
| Mounting mode | By screws (terminals) |
| Electrical connection (voltage sensing & power supply) | Wires with cable end |
| Cable cross section | 1 rigid cable 1.5â¦16 mm² 2 stranded cable 1.5â¦2.5 mm² 2 rigid cable 1.5â¦2.5 mm² 1 stranded cable 1.5â¦16 mm² |
| Cable length | 0.25 m |
| supply voltage | 220...240 V AC, +/- 20 %, between phase and neutral 380...415 V AC, +/- 20 %, between phases |
| Network frequency | 50 Hz 60 Hz |
| Maximum power consumption | 2 VA |
| Standards | IEC 61557-12 IEC 61010-1 IEC 61010-2-030 IEC 61326-1 ETSI EN 300 328 ETSI EN 301 489-1 |
| Height | Sensor element: 20 mm |
| Width | Sensor element: 54 mm |
| Depth | Sensor element: 46.6 mm |
| Product weight | 40 g |
| Colour | White (RAL 9003) |
| Compatibility code | PowerTag A9 P63 |

This Acti9 iPRD-DC 40r direct current surge arresters protects 2P photovoltaic installations. It allows quick replacement of damaged cartridges. The Itotal discharge current is 40kA. The In nominal discharge current is 15kA. This Type 2 device is recommended to protect against indirect lightning strikes. The surge arresters with r indication have remote transfer of the information Cartridge to be replaced. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The Uc maximum continuous operating voltage is 800VDC. The Up protection level is 3kV in differential mode and in common mode. The Ue rated operational voltage is 800VDC +/- 10%. The product colour is white (RAL9003). The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The width in 9mm pitches is 4. The weight is 400g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product complies with UTE C 61470-51 and EN 50539-11:2013 standards.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iPRD PV-DC |
| Device short name | iPRD PV-DC |
| Product or component type | Surge arrester with pluggable cartridge |
| Poles description | 2P |
| Output type | Contact (volt-free) |
| Signal contacts composition | 1 SD (1 C/O) |
| Surge arrester type | Electrical distribution network |
| Uoc stc: Maximum open circuit voltage of PV generator in standard test condition | 666 V |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 |
| Surge arrester technology | MOV |
| [Ue] rated operational voltage | 800 V +/- 10 % DC |
| [In] nominal discharge current | 15 kA |
| [Imax] maximum discharge current | 40 kA |
| [Ucpv] maximum continuous operating voltage | Differential mode: 800 V L+/L- Common mode: 800 V L+/PE Common mode: 800 V L-/PE |
| Maximum [Up] voltage protection level | Differential mode <3 kV type 2 L+/L- Common mode <3 kV type 2 L+/PE Common mode <3 kV type 2 L-/PE |
| Disconnector device type | Integrated disconnector |
| Local signalling | White/red flag |
| Signalling circuit voltage | AC: 250 V 50/60 Hz |
| Signalling output current | 0.25 A |
| Mounting mode | Clip-on |
| Mounting support | DIN rail |
| 9 mm pitches | 6 |
| Height | 85 mm |
| Width | 54 mm |
| Depth | 69 mm |
| Product weight | 400 g |
| Colour | White (RAL 9003) |
| Response time | <= 25 ns |
| Connections - terminals | Tunnel type terminal 2.5â¦25 mm² rigid Tunnel type terminal 2.5â¦16 mm² flexible Tunnel type terminal 2.5â¦16 mm² flexible stranded |
| Wire stripping length | 14 mm |
| Tightening torque | 3.5 N.m |

This Acti9 iTLs is a modular impulse relay. This 1P device has 1 normally open contact. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 24VAC or 12VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 100 switching operations/day or 5 switching operations/minute. The duration of the command order should be between 50ms to 1s. It is mainly used for lighting control applications. This impulse relays allow remote indication of their operating state. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 18mm x (H) 84mm x (D) 60mm. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -20°C to 50°C. The storage temperature is from -40°C to 70°C. This product is compliant with IEC/EN 60669-1 and IEC/EN 60669-2-2 standard.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iTL |
| Product or component type | Impulse relay |
| Device short name | iTLs |
| Device application | Remote indication |
| Poles | 1P |
| Pole contact composition | 1 NO |
| Auxiliary contact composition | 1 C/O |
| [In] rated current | 16 A |
| Network type | AC |
| [Uc] control circuit voltage | 24 V AC 50/60 Hz 12 V DC |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network frequency | 50/60 Hz |
| [Ue] rated operational voltage | 250 V AC 50/60 Hz |
| control type | Remote and manual control Coil deconnection |
| Control signal type | Impulse |
| Switching frequency | 100 switching operations/day 5 switching operations/minute |
| Impulse duration | 50 ms...1 s |
| Remote control type | Illuminated push-button 3 mA |
| Local signalling | ON/OFF indication |
| Signalling circuit voltage | AC: 24...240 V DC: 24...240 V |
| Signalling output current | 0.01...6 A |
| Mounting mode | Fixed |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 84 mm |
| Width | 18 mm |
| Depth | 60 mm |
| Electrical durability | AC-21: 200000 cycles AC-22: 100000 cycles |
| Connections - terminals | Control circuit: tunnel type terminals 1 cable(s) 0.5â¦4 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 0.5â¦4 mm² rigid with cable end Control circuit: tunnel type terminals 1 cable(s) 1â¦4 mm² flexible Control circuit: tunnel type terminals 1 cable(s) 1â¦4 mm² flexible with ferrule Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² rigid Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² rigid with cable end Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² flexible Power circuit: tunnel type terminals 1 cable(s) 1.5â¦4 mm² flexible with ferrule |
| Wire stripping length | 11 mm |
| Tightening torque | 1 N.m |
| Range compatibility | Acti9 iATEt Acti9 iATLc Acti9 iATLc+s Acti9 iATLm Acti9 iATLs Acti9 iETL iTL 16 Acti9 iATLc+c |

This PowerTag Energy P63 3P+N Top is a wireless communication energy sensor. It is dedicated to Acti9 and Multi9 3P+N PhaseNeutral devices with 9mm pitch between phase and neutral, rating less than or equal 63A. It has to be associated with a concentror or a gateway to provide circuit monitoring and diagnosis down to load level. It is designed specifically for Energy Management, Load Monitoring and Power Availability applications. It incorporates accurate real-time measurements of active energy, active power, current, voltage and power factor. In case of power outage, it sends a voltage loss alarm and the current-per-phase value before being de-energized. PowerTag Energy 63A complies with IEC 61557-12 standard. It is a PMD-I/DD/K55/1. The Performance category is Class 1. The Imax Maximum current is 63A. The Ib Base current is 10A. The Saturation current is 130A. The Ist Starting current is 40mA. The Un rated voltage are Phase-to-neutral 220VAC to 240VAC +/- 20% and Phase-to-phase 380VAC to 415VAC +/- 20%. The maximum consumption is below or equal to 2VA. It can be only mounted on the top of the protective device. The product color is white (RAL9003). The weight is 48g. The degree of protection is IP20 and IK05 The operating temperature is between -25°C to +60°C. The Storage temperature is between -40°C to +85°C.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | PowerLogic |
| product name | PowerTag A9 P63 |
| Product or component type | Energy sensor |
| Poles | 3P + N |
| Maximum current [Imax] | 63 A |
| [Ib] Basic current | 10 A |
| Starting current | 40 mA |
| Saturation current | 130 A |
| Product specific application | Load monitoring Overload alarm Circuit monitoring Cost allocation Energy management |
| Concentrator compatibility | Acti9 Smartlink SI B Acti9 Smartlink SI D Acti9 PowerTag Link C Acti9 PowerTag Link Acti9 PowerTag Link HD Wiser IP module EcoStruxure Panel Server Universal EcoStruxure Panel Server Advanced PrismaSet Active |
| Application | Buildings: breaker voltage monitoring Buildings: cost allocation Buildings: overload alarm |
| Range compatibility | Multi9 Multi9 N40 Vigi Acti 9 Acti9 C40 Vigi Acti 9 Acti9 iDPN Acti 9 Acti9 iC40 Multi9 Multi9 N40 Acti 9 Acti9 iCV40 Acti 9 Acti9 C40 Acti 9 Acti9 DT40 Acti 9 Acti9 DT40 Vigi Acti 9 Acti9 iDPN Vigi |
| Type of measurement | Active power Power factor Active energy Voltage Current |
| Accuracy class | Class 1 current conforming to IEC 61557-12 Class 0.5 voltage conforming to IEC 61557-12 Class 1 active power conforming to IEC 61557-12 Class 1 active energy conforming to IEC 61557-12 Class 1 power factor conforming to IEC 61557-12 |
| Mounting location | Top |
| Mounting support | On circuit breaker |
| Connection pitch | 9 mm Ph/N 18 mm Ph/Ph |
| Product destination | Switchboard |
| Event management | Voltage loss with measured current at voltage loss |
| Transmission support medium | Radio frequency 2.4â¦2.4835 GHz conforming to IEEE 802.15.4 |
| Emission power | 10 mW |
Complementary
| Characteristic | Value(s) |
|---|---|
| Form factor | PhaseNeutral |
| Mounting mode | By screws (terminals) |
| Electrical connection (voltage sensing & power supply) | Connector tooth |
| Cable cross section | 1 rigid cable 1.5â¦16 mm² 2 stranded cable 1.5â¦2.5 mm² 2 rigid cable 1.5â¦2.5 mm² 1 stranded cable 1.5â¦16 mm² |
| supply voltage | 220...240 V AC, +/- 20 %, between phase and neutral 380...415 V AC, +/- 20 %, between phases |
| Network frequency | 50 Hz 60 Hz |
| Maximum power consumption | 2 VA |
| Standards | IEC 61557-12 IEC 61010-1 IEC 61010-2-030 IEC 61326-1 ETSI EN 300 328 ETSI EN 301 489-1 |
| Height | Sensor element: 19.5 mm Base unit: 8 mm |
| Width | Sensor element: 54 mm Base unit: 54 mm |
| Depth | Sensor element: 43 mm Base unit: 48 mm |
| Product weight | 48 g |
| Colour | White (RAL 9003) |
| Compatibility code | PowerTag A9 P63 |

Main
| Characteristic | Value(s) |
|---|---|
| Product or component type | Cartridge |
| Device short name | C20-350 |
| Surge arrester type | Electrical distribution network |
| Standards | IEC 61643-11: 2011 EN 61643-11 |
| Quality labels | CE |
Complementary
| Characteristic | Value(s) |
|---|---|
| Surge arrester class type | Type 2 |
| Surge arrester technology | MOV |
| Product destination | Surge protection device iPRD20r Surge protection device iPRD20 |
| Earthing system | TT TN |
| [Ue] rated operational voltage | 230 V AC 50 Hz |
| Nominal discharge current | 5 kA |
| Maximum discharge current | 20 kA |
| [Uc] maximum continuous operating voltage | 350 V |
| Maximum [Up] voltage protection level | <1.1 kV type 2 |
| Local signalling | Flag (white/red) |
| Mounting mode | Plug-in |
| Mounting support | Into SPD module |
| 9 mm pitches | 2 |
| Height | 57 mm |
| Width | 18 mm |
| Depth | 56 mm |
| Product weight | 0.051 kg |
| Colour | White (RAL 9003) |
| Material | PBT (polybutylene terephthalate) |