Drives - Motors - Circuits Protection

973 products

Showing 553 - 576 of 973 products

Showing 553 - 576 of 973 products
View
A9C30812 Schneider Electric
Schneider A9C30812 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 iTL is a modular impulse relay. This 2P device has 2 normally open contacts. Rated current is 16A, 24VAC to 250VAC operating voltage and it operates with 230VAC to 240VAC or 110VDC control voltage. Electrical endurance goes up to 200000 cycles for AC-21 or 100000 cycles for AC-22. The switching frequency is 5 switching operations/minute or 100 switching operations/day. The duration of the command order should be between 50ms to 1s. It is mainly used for lighting control applications. The Ui rated insulation voltage is 440VAC. The Uimp rated impulse withstand voltage is 6kV. The operating frequency is 50Hz or 60Hz. It is DIN rail mountable. Pollution degree is 3. Overvoltage category is IV. The dimensions are (W) 18mm x (H) 84mm x (D) 60mm. The degree of protection is IP20 and IP40 in an enclosure. The operating temperature is from -20°C to 50°C. The storage temperature is from -40°C to 70°C. This product is compliant with IEC/EN 60669-1 and IEC/EN 60669-2-2 standard.

Main

Characteristic Value(s)
range of product Acti9
product name Acti9 iTL
Product or component type Impulse relay
Device short name iTL
Device application Standard
Poles 2P
Pole contact composition 2 NO
[In] rated current 16 A
Network type AC
[Uc] control circuit voltage 230...240 V AC 50/60 Hz
110 V DC

Complementary

Characteristic Value(s)
Network frequency 50/60 Hz
[Ue] rated operational voltage 250 V AC 50/60 Hz
control type Remote and manual control
Coil deconnection
Control signal type Impulse
Switching frequency 5 switching operations/minute
100 switching operations/day
Impulse duration 50 ms...1 s
Remote control type Illuminated push-button 3 mA
Local signalling ON/OFF indication
Mounting mode Fixed
Mounting support DIN rail
9 mm pitches 2
Height 84 mm
Width 18 mm
Depth 60 mm
Electrical durability AC-21: 200000 cycles
AC-22: 100000 cycles
Connections - terminals Control circuit: tunnel type terminals 1 cable(s) 0.5…4 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 0.5…4 mm² rigid with cable end
Control circuit: tunnel type terminals 1 cable(s) 1…4 mm² flexible
Control circuit: tunnel type terminals 1 cable(s) 1…4 mm² flexible with ferrule
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² rigid
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² rigid with cable end
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² flexible
Power circuit: tunnel type terminals 1 cable(s) 1.5…4 mm² flexible with ferrule
Wire stripping length 11 mm
Tightening torque 1 N.m
Range compatibility Acti9 iATEt
Acti9 iATL4
Acti9 iATLc
Acti9 iATLc+s
Acti9 iATLm
Acti9 iATLs
Acti9 iATLz
Acti9 iETL iTL 16
Acti9 iATLc+c
Acti9 iATL24
A9C21642 Schneider Electric
Schneider A9C21642 Schneider Electric
Sale price$0.00
Sold Out

iCT 40A 2NO 220...240V 60Hz MO contact

A9C21842 Schneider Electric
Schneider A9C21842 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 iCT is a modular contactor. It is a 2P remote control device with 2 normally open contact. The rated current is 40A for AC-7a and 15A for AC-7b. The Ue rated operational voltage is 250VAC. The Uc control voltage is 220VAC to 240VAC. This device could be used for control circuits. This device could be used for remote switching small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B. The maximum switching operations is 100 per day. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 4 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 85mm x (H) 36mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.

Main

Characteristic Value(s)
range of product Acti9
product name Acti9 iCT
Product or component type Contactor
Device short name iCT
Device application Motor-heating-lighting
Poles 2P
[Ie] rated operational current 40 A AC-7A
15 A AC-7B
Pole contact composition 2 NO
Network type AC
control type Remote and manual control
[Uc] control circuit voltage 220...240 V AC 50 Hz

Complementary

Characteristic Value(s)
Network frequency 50 Hz
[Ue] rated operational voltage 250 V AC 50 Hz
Maximum power 1.6 W at 250 V AC
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 4 kV
Control signal type Maintained
Switching frequency 100 switching operations/day
Local signalling Action indicator
Hold-in power consumption in VA 4.6 VA
Inrush power in VA 34 VA
Mounting mode Clip-on
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 4
Height 85 mm
Width 36 mm
Depth 60 mm
Colour White
Mechanical durability 1000000 cycles
Electrical durability 100000 cycles IEC/EN 61095 40 A 50 Hz AC-7A
30000 cycles IEC/EN 61095 15 A 50 Hz AC-7B
30000 cycles IEC/EN 61095 50 Hz AC-7C
100000 cycles EN/IEC 60947-4-1 50 Hz AC-1
30000 cycles EN/IEC 60947-4-1 50 Hz AC-3
30000 cycles EN/IEC 60947-4-1 50 Hz AC-5a
30000 cycles EN/IEC 60947-4-1 50 Hz AC-5b
Connections - terminals Control circuit: tunnel type terminals2 cable(s) 1.5 mm² rigid
Control circuit: tunnel type terminals1 cable(s) 1.5…2.5 mm² rigid
Power circuit: tunnel type terminals1 cable(s) 6…16 mm² flexible
Power circuit: tunnel type terminals1 cable(s) 6…25 mm² rigid
Control circuit: tunnel type terminals2 cable(s) 1.5…2.5 mm² flexible
Tightening torque Control circuit: 0.8 N.m
Power circuit: 3.5 N.m
Product compatibility IACTp
IACTs
IATEt
IACTc
Compatibility code ICT
Market segment Small commercial
Residential
A9C30831 Schneider Electric
Schneider A9C30831 Schneider Electric
Sale price$0.00
Sold Out

impulse relay iTL - 1P - 1NO - 32A - coil 110 VDC - 230...240 VAC 50/60Hz

A9L20421 Schneider Electric
Schneider A9L20421 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 iPRD20r surge arrester protects 4P installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for medium risk level and incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode (between phase and earth) is 460VAC. The Up Voltage protection level in common mode (L/PE or N/PE) is 1.8kV. The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 72mm x (H) 85mm x (D) 69mm. The weight is 450g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.

Main

Characteristic Value(s)
Range of product IPRD
range of product Acti9
product name Acti9 iPRD
Product or component type Surge arrester with pluggable cartridge
Device short name iPRD20r
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Poles description 4P
Remote signalling With
Signal contacts composition 1 SD (1 C/O)
Surge arrester type Electrical distribution network
Earthing system IT

Complementary

Characteristic Value(s)
Surge arrester class type Type 2
Surge arrester technology MOV
[Ue] rated operational voltage 230/400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 5 kA (L/PE)
Common mode: 5 kA (N/PE)
Maximum discharge current Common mode: 20 kA L/PE
Common mode: 20 kA N/PE
[Uc] maximum continuous operating voltage Common mode: 460 V L/PE
Maximum [Up] voltage protection level Common mode <1.8 kV type 2 L/PE
Common mode <1.8 kV type 2 N/PE
[Ut] temporary overvoltage 337 V L/N 5 s withstand
1455 V L/PE 200 ms safe failure mode
1455 V N/PE 200 ms safe failure mode
Short-circuit withstand 5 kA 415 V Ph/Ph
Disconnector device type Associated circuit breaker IC60N 20 A curve C - Icu 10 kA
Associated circuit breaker iC60H 20 A curve C - Icu 15 kA
Associated circuit breaker iC60L 20 A curve C - Icu 25 kA
Associated fuse gG 40 A - Icu 15 kA
Associated fuse gG 80 A - Icu 50 kA
Associated circuit breaker NG125H 20 A curve C - Icu 36 kA
Associated circuit breaker NG125L 20 A curve C - Icu 50 kA
Signalling circuit voltage 0.25 A/250 V AC 50/60 Hz
Mounting mode Clip-on (DIN rail)
9 mm pitches 8
Height 85 mm
Width 72 mm
Depth 69 mm
Product weight 450 g
Colour White (RAL 9003)
[Ipe] Ground residual current 0.6 mA
Connections - terminals Tunnel type terminal (top or bottom) 2.5…25 mm² rigid
Tunnel type terminal (top or bottom) 4…16 mm² flexible
Tunnel type terminal (top or bottom) 4…16 mm² flexible with ferrule
Wire stripping length 14 mm
Tightening torque 3.5 N.m
Targeted country All
Compatibility code IPRD20r
A9C30811 Schneider Electric
Schneider A9C30811 Schneider Electric
Sale price$0.00
Sold Out

impulse relay iTL - 1P - 1NO - 16A - coil 110 VDC - 230...240 VAC 50/60Hz

A9L08601 Schneider Electric
Schneider A9L08601 Schneider Electric
Sale price $456.99
Only 1 unit left

iPRD8r modular surge arrester - 3P + N - 350V - with remote transfert

A9C22115 Schneider Electric
Schneider A9C22115 Schneider Electric
Sale price$0.00
Sold Out

iCT 16A 1NO 1NC 24V 50Hz contactor

A9L40321 Schneider Electric
Schneider A9L40321 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 iPRD40r surge arrester protects 3P installations. It allows quick replacement of damaged cartridges. This Type 2 device is recommended for high risk level in incoming panel board. It offers remote reporting of the "cartridge must be changed" message. It can be turned over to allow the phase/neutral/earth cables to enter through either the top or the bottom. The associated circuit breaker Isc breaking capacity can go up to 50kA. It is compatible with TT and TN-S earthing system. The Uc maximum continuous operating voltage in common mode (between phase and earth) is 460VAC. The Up Voltage protection level in common mode (between phase and earth) is 2.2kV. The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The weight is 340g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.

Main

Characteristic Value(s)
Range of product IPRD
range of product Acti9
product name Acti9 iPRD
Product or component type Surge arrester with pluggable cartridge
Device short name iPRD40r
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Poles description 3P
Remote signalling With
Signal contacts composition 1 SD (1 C/O)
Surge arrester type Electrical distribution network
Earthing system IT

Complementary

Characteristic Value(s)
Surge arrester class type Type 2
Surge arrester technology MOV
[Ue] rated operational voltage 400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 15 kA (L/PE)
Maximum discharge current Common mode: 40 kA L/PE
[Uc] maximum continuous operating voltage Common mode: 460 V L/PE
Maximum [Up] voltage protection level Common mode <2.2 kV type 2 L/PE
[Ut] temporary overvoltage 337 V L/N 5 s withstand
1455 V L/PE 200 ms safe failure mode
1455 V N/PE 200 ms safe failure mode
Short-circuit withstand 5 kA 415 V Ph/Ph
Disconnector device type Associated fuse gG 63 A - Icu 15 kA
Associated fuse gG 80 A - Icu 50 kA
Associated circuit breaker NG125L 40 A curve C - Icu 50 kA
Associated circuit breaker NG125H 40 A curve C - Icu 36 kA
Associated circuit breaker IC60N 40 A curve C - Icu 10 kA
Associated circuit breaker iC60H 40 A curve C - Icu 15 kA
Associated circuit breaker NG125N 40 A curve C - Icu 25 kA
Signalling circuit voltage 0.25 A/250 V AC 50/60 Hz
Mounting mode Clip-on (DIN rail)
9 mm pitches 6
Height 85 mm
Width 54 mm
Depth 69 mm
Product weight 340 g
Colour White (RAL 9003)
[Ipe] Ground residual current 0.6 mA
Connections - terminals Tunnel type terminal (top or bottom) 2.5…25 mm² rigid
Tunnel type terminal (top or bottom) 4…16 mm² flexible
Tunnel type terminal (top or bottom) 4…16 mm² flexible with ferrule
Wire stripping length 14 mm
Tightening torque 3.5 N.m
Targeted country All
Compatibility code IPRD40r
A9C30815 Schneider Electric
Schneider A9C30815 Schneider Electric
Sale price$0.00
Sold Out

impulse relay iTLI - 2P - 1NO+1NC - 16A - coil 110 VDC - 230...240 VAC 50/60Hz

A9L16292 Schneider Electric
Schneider A9L16292 Schneider Electric
Sale price $584.55
Only 1 unit left

iQuick PRD40r modular surge arrester - 1 pole + N - 350V - with remote transfer

A9C61240 Schneider Electric
Schneider A9C61240 Schneider Electric
Sale price$0.00
Sold Out

It is a 2P circuit breaker with protected poles, 40 A rated current and B tripping curve. As circuit breaker, its breaking capacity, according to IEC/EN 60947-2, is 20kA at 220VAC to 240VAC, and 10kA at 380VAC to 415VAC. It allows to execute remote control, to indicate the state of the control circuit and circuit breaker state information, to connect it to the Acti9 Smartlink thanks to the prefabricated cables.

Main

Characteristic Value(s)
Device application Control
Distribution
Range Acti9
product name Reflex iC60
Device short name Reflex iC60N
Product or component type Integrated control circuit breaker
Poles description 2P
Number of protected poles 2
Network type AC
Trip unit technology Thermal-magnetic
Curve code B

Complementary

Characteristic Value(s)
[In] rated current 40 A
Network frequency 50/60 Hz
Breaking capacity code N
Breaking capacity 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC
Contact position indicator Yes
control type Remote control by continuous command
ON/OFF button
Toggle
Remote control by pulse
Control signal type Maintained
Maintained very low voltage
Impulse
Local signalling Flashing LED: device overheat
Red LED: fault
Flashing LED: device ready
Green LED: device ON
Flashing LED: device tripped
[Uc] control circuit voltage 230 V AC 50/60 Hz
24 V AC 50/60 Hz
48 V AC 50/60 Hz
24 V DC
48 V DC
[Us] rated supply voltage 230 V AC at 50/60 Hz
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 9
Height 84 mm
Width 81 mm
Depth 77 mm
Colour White
Mechanical durability 50000 cycles
Electrical durability AC-1: 50000 cycles AC 50 Hz
Provision for padlocking Padlockable
Locking options description Padlock in OFF position
Earth-leakage protection Separate block
Product compatibility With PLC
A9C61416 Schneider Electric
Schneider A9C61416 Schneider Electric
Sale price$0.00
Sold Out

Reflex iC60N Ti24 16 A 4P curve B integrated control MCB

A9L16619 Schneider Electric
Schneider A9L16619 Schneider Electric
Sale price$0.00
Sold Out

Acti 9 - iSR remote signal auxiliary Surge Arrester

A9L08321 Schneider Electric
Schneider A9L08321 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 iPRD8r surge arrester protects 3P installations. It allows quick replacement of damaged cartridges. The Imax maximum discharge current is 8kA .The In nominal discharge current is 2.5kA. The iPRD8r ensures secondary protection of loads to be protected and is placed in cascade with the incoming surge arresters. This surge arrester is required when the loads to be protected are at a distance of more than 10 m from the incoming surge arrester. The surge arresters with "r" indication have remote transfer of the information "Cartridge to be replaced". The Uc maximum continuous operating voltage in common mode (between neutral and earth) is 460VAC. The Up Voltage protection level in common mode (between phase and earth) is 1.6kV in type2. The Up Voltage protection level in common mode (between phase and earth) is 1.8kV in type 3. The Ue rated operational voltage is 230VAC or 400VAC +/- 10%. The product colour is white (RAL9003).The dimensions are (W) 54mm x (H) 85mm x (D) 69mm. The weight is 340g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to 60°C. The storage temperature is -40°C to 85°C. This product is compliant with EN 61643-11 and IEC 61643-11 standards.

Main

Characteristic Value(s)
Range of product IPRD
range of product Acti9
product name Acti9 iPRD
Product or component type Surge arrester with pluggable cartridge
Device short name iPRD8r
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Poles description 3P
Remote signalling With
Signal contacts composition 1 SD (1 C/O)
Surge arrester type Electrical distribution network
Earthing system IT

Complementary

Characteristic Value(s)
Surge arrester class type Type 2 + 3
Surge arrester technology MOV
[Ue] rated operational voltage 400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 2.5 kA (L/PE)
Maximum discharge current Common mode: 8 kA L/PE
[Uc] maximum continuous operating voltage Common mode: 460 V L/PE
Maximum [Up] voltage protection level Common mode <1.6 kV type 2 L/PE
Common mode <1.8 kV type 3 L/PE
[Ut] temporary overvoltage 337 V L/N 5 s withstand
1455 V L/PE 200 ms safe failure mode
1455 V N/PE 200 ms safe failure mode
Short-circuit withstand 5 kA 415 V Ph/Ph
Disconnector device type Associated circuit breaker iC60L 10 A curve C - Icu 25 kA
Associated fuse gG 25 A - Icu 15 kA
Associated fuse gG 80 A - Icu 50 kA
Signalling circuit voltage 0.25 A/250 V AC 50/60 Hz
Mounting mode Clip-on (DIN rail)
9 mm pitches 6
Height 85 mm
Width 54 mm
Depth 69 mm
Product weight 340 g
Colour White (RAL 9003)
[Ipe] Ground residual current 0.6 mA
Connections - terminals Tunnel type terminal (top or bottom) 2.5…25 mm² rigid
Tunnel type terminal (top or bottom) 4…16 mm² flexible
Tunnel type terminal (top or bottom) 4…16 mm² flexible with ferrule
Tightening torque 3.5 N.m
Targeted country All
Compatibility code IPRD8r
A9L16300 Schneider Electric
Schneider A9L16300 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 iQuick PRD8r surge arrester protects 3P+N residential and larger buildings installations against indirect transient overvoltages. This Type 2 or Type 3 device autoprotected by integrated circuit-breaker is recommended for moderate risk level in secondary panel board. It offers remote reporting of the "cartridge must be changed" message. This prewired surge arrester allows quick replacement of withdrawable cartridges when they are damaged. It incorporates its end of life safety disconnector. The Isc integrated breaking capacity is 25kA. This Acti9 iQuick PRD8r is compatible with TT and TN-S earthing system. The Imax maximum discharge current is 8kA. The In nominal discharge current is 2kA. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in common mode is 264VAC between neutral and earth, and is 350VAC between phase and earth. The Up Voltage protection level in type 2 is 1.5kV in common mode (L/PE or N/PE), and is 1.2kV in differential mode (L/N). The Up Voltage protection level in type 3 is 1.4kV in common mode (L/PE), 1.5kV in common mode (N/PE), and 1.4kV in differential mode (L/N). The Un rated service voltage is 230VAC or 400VAC. The operating frequency is 50Hz or 60Hz. The dimensions are (W) 131.5mm x (H) 103.8mm x (D) 75.9mm. The width in 9mm pitches is 15. The weight is 810g. The degree of protection is IP20 and IP40 in modular enclosure. The operating temperature is -25°C to +60°C. The storage temperature is -40°C to +85°C. This product complies with IEC/EN 60947-5-1 and EN 61643-11: 2012 and IEC 61643-11: 2011 Type 2 standards.

Main

Characteristic Value(s)
Range of product IQuick PRD
range of product Acti9
product name Acti9 iQuick PRD
Product or component type Surge arrester with pluggable cartridge
Device short name iQuick PRD8r
Device application Distribution
Standards EN 61643-11:2012
IEC 61643-11:2011
Product certifications CE
Quality labels KEMA-KEUR
NF
Poles description 3P + N
Remote signalling With
Signal contacts composition 1 SD (1 C/O)
Surge arrester type Electrical distribution network
Earthing system TT
TN-S

Complementary

Characteristic Value(s)
Surge arrester class type Type 2 + 3
Surge arrester technology MOV + GDT
[Ue] rated operational voltage 230/400 V AC (+/- 10 %) at 50/60 Hz
Nominal discharge current Common mode: 2 kA (L/PE)
Common mode: 2 kA (N/PE)
Differential mode: 2 kA (L/N)
Maximum discharge current Common mode: 8 kA L/PE
Common mode: 8 kA N/PE
Differential mode: 8 kA L/N
[Uoc] open circuit voltage 10 kV type 3 common mode L/PE
10 kV type 3 common mode N/PE
10 kV type 3 differential mode L/N
[Uc] maximum continuous operating voltage Common mode: 264 V N/PE
Common mode: 350 V L/PE
Differential mode: 350 V L/N
Maximum [Up] voltage protection level Common mode <1.5 kV type 2 L/PE
Common mode <1.7 kV type 2 N/PE
Differential mode <1.2 kV type 2 L/N
Common mode <1.4 kV type 3 L/PE
Differential mode <1.4 kV type 3 L/N
Common mode <1.5 kV type 3 N/PE
Disconnector device type Integrated circuit breaker - Icu 25 kA
Signalling circuit voltage 2 A/250 V AC 50/60 Hz
Mounting mode Clip-on (DIN rail)
9 mm pitches 14.6
Height 94 mm
Width 131.5 mm
Depth 75.9 mm
Product weight 0.84 kg
Colour White (RAL 9003)
Connections - terminals Tunnel type terminal (downside) 2.5…25 mm²
Tunnel type terminal (upside) 2.5…25 mm²
Tightening torque 2.5 N.m
Compatibility code IQuick PRD8r
A9C61210 Schneider Electric
Schneider A9C61210 Schneider Electric
Sale price$0.00
Sold Out

It is a 2P circuit breaker with protected poles, 10 A rated current and B tripping curve. As circuit breaker, its breaking capacity, according to IEC/EN 60947-2, is 20kA at 220VAC to 240VAC, and 10kA at 380VAC to 415VAC. It allows to execute remote control, to indicate the state of the control circuit and circuit breaker state information, to connect it to the Acti9 Smartlink thanks to the prefabricated cables.

Main

Characteristic Value(s)
Device application Control
Distribution
Range Acti9
product name Reflex iC60
Device short name Reflex iC60N
Product or component type Integrated control circuit breaker
Poles description 2P
Number of protected poles 2
Network type AC
Trip unit technology Thermal-magnetic
Curve code B

Complementary

Characteristic Value(s)
[In] rated current 10 A
Network frequency 50/60 Hz
Breaking capacity code N
Breaking capacity 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC
Contact position indicator Yes
control type Toggle
ON/OFF button
Remote control by pulse
Remote control by continuous command
Control signal type Impulse
Maintained very low voltage
Maintained
Local signalling Flashing LED: device ready
Red LED: fault
Flashing LED: device overheat
Green LED: device ON
Flashing LED: device tripped
[Uc] control circuit voltage 230 V AC 50/60 Hz
24 V AC 50/60 Hz
48 V AC 50/60 Hz
24 V DC
48 V DC
[Us] rated supply voltage 230 V AC at 50/60 Hz
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 9
Height 84 mm
Width 81 mm
Depth 77 mm
Colour White
Mechanical durability 50000 cycles
Electrical durability AC-1: 50000 cycles AC 50 Hz
Provision for padlocking Padlockable
Locking options description Padlock in OFF position
Earth-leakage protection Separate block
Product compatibility With PLC
A9L16339 Schneider Electric
Schneider A9L16339 Schneider Electric
Sale price$0.00
Sold Out

The Uc maximum continuous operating voltage in common mode (between phase and earth) is 37 VAC or 53VDC. The Uc maximum continuous operating voltage in differential mode (between phase and neutral) is 37VAC or 53VDC.

Main

Characteristic Value(s)
range of product Acti9
product name Acti9 iPRI
Device short name iPRI
Product or component type Surge arrester
number of protected lines 4
Surge arrester type Signal protection

Complementary

Characteristic Value(s)
Remote signalling Without
Surge arrester technology GDT
[In] rated current 0.3 A at 45 °C
[Ue] rated operational voltage 48 V DC
Nominal discharge current Common mode: 20 kA (L/PE)
[Iimp] impulse current 70 A
[Uc] maximum continuous operating voltage Common mode: 37 V AC L/PE
Common mode: 53 V DC L/PE
Differential mode: 37 V AC L/N
Differential mode: 53 V DC L/N
Maximum [Up] voltage protection level Common mode <70 V type 2 L/PE
Differential mode <70 V type 2 L/N
Output voltage limits Common mode: < 70 V at 1 kV/µs
[I total] discharge current 20 kA
Local signalling electrical
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 2
Height 90 mm
Width 18 mm
Depth 66 mm
Product weight 65 g
Colour White
Material PA6
Response time < 1 ns
Connections - terminals Screw clamp terminal0.2…4 mm² rigid
Screw clamp terminal0.2…2.5 mm² flexible
Screw clamp terminal0.2…2.5 mm² flexible with ferrule
Wire stripping length 8 mm
Tightening torque 0.8 N.m
A9C61310 Schneider Electric
Schneider A9C61310 Schneider Electric
Sale price$0.00
Sold Out

Reflex iC60N Ti24 10 A 3P curve B integrated control MCB

A9C21834 Schneider Electric
Schneider A9C21834 Schneider Electric
Sale price$0.00
Sold Out

iCT 25A 4NO 220...240V 50Hz MO contact

A9L08200 Schneider Electric
Schneider A9L08200 Schneider Electric
Sale price$0.00
Sold Out

iPRD8 modular surge arrester - 2P - 350V

A9C61410 Schneider Electric
Schneider A9C61410 Schneider Electric
Sale price$0.00
Sold Out

It is a 4P circuit breaker with protected poles, 10 A rated current and B tripping curve. As circuit breaker, its breaking capacity, according to IEC/EN 60947-2, is 20kA at 220VAC to 240VAC, and 10kA at 380VAC to 415VAC. It allows to execute remote control, to indicate the state of the control circuit and circuit breaker state information, to connect it to the Acti9 Smartlink thanks to the prefabricated cables.

Main

Characteristic Value(s)
Device application Distribution
Control
Range Acti9
product name Reflex iC60
Device short name Reflex iC60N
Product or component type Integrated control circuit breaker
Poles description 4P
Number of protected poles 4
Network type AC
Trip unit technology Thermal-magnetic
Curve code B

Complementary

Characteristic Value(s)
[In] rated current 10 A
Network frequency 50/60 Hz
Breaking capacity code N
Breaking capacity 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC
Contact position indicator Yes
control type Toggle
ON/OFF button
Remote control by pulse
Remote control by continuous command
Control signal type Impulse
Maintained very low voltage
Maintained
Local signalling Flashing LED: device overheat
Red LED: fault
Flashing LED: device ready
Green LED: device ON
Flashing LED: device tripped
[Uc] control circuit voltage 230 V AC 50/60 Hz
24 V AC 50/60 Hz
48 V AC 50/60 Hz
24 V DC
48 V DC
[Us] rated supply voltage 230 V AC at 50/60 Hz
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 13
Height 84 mm
Width 117 mm
Depth 77 mm
Colour White
Mechanical durability 50000 cycles
Electrical durability AC-1: 50000 cycles AC 50 Hz
Provision for padlocking Padlockable
Locking options description Padlock in OFF position
Earth-leakage protection Separate block
Product compatibility With PLC
A9C62225 Schneider Electric
Schneider A9C62225 Schneider Electric
Sale price$0.00
Sold Out

Reflex iC60N Ti24 25 A 2P curve C integrated control MCB

A9C61340 Schneider Electric
Schneider A9C61340 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Device application Control
Distribution
Range Acti9
product name Reflex iC60
Device short name Reflex iC60N
Product or component type Integrated control circuit breaker
Poles description 3P
Number of protected poles 3
Network type AC
Trip unit technology Thermal-magnetic
Curve code B

Complementary

Characteristic Value(s)
[In] rated current 40 A
Network frequency 50/60 Hz
Breaking capacity code N
Breaking capacity 20 kA Icu at 220...240 V AC 50/60 Hz conforming to EN/IEC 60947-2
10 kA Icu at 380...415 V AC 50/60 Hz conforming to EN/IEC 60947-2
[Ui] rated insulation voltage 500 V AC
Contact position indicator Yes
control type Remote control by continuous command
Remote control by pulse
ON/OFF button
Toggle
Control signal type Maintained
Impulse
Maintained very low voltage
Local signalling Green LED: device ON
Flashing LED: device overheat
Flashing LED: device tripped
Flashing LED: device ready
Red LED: fault
[Uc] control circuit voltage 230 V AC 50/60 Hz
24 V AC 50/60 Hz
48 V AC 50/60 Hz
24 V DC
48 V DC
[Us] rated supply voltage 230 V AC at 50/60 Hz
Mounting mode Fixed
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 11
Height 84 mm
Width 99 mm
Depth 77 mm
Colour White
Mechanical durability 50000 cycles
Electrical durability AC-1: 50000 cycles AC 50 Hz
Provision for padlocking Padlockable
Locking options description Padlock in OFF position
Earth-leakage protection Separate block
Product compatibility With PLC

Recently viewed