Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
97.8 mm
86.05 mm
0.265 kg
Technical
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(400 V AC) 100 kA
200 A
6.3 ... 10 A
Main Circuit 690 V AC
10 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 0.7 ... 1.7 W
3P
Main Circuit 10 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Main Circuit 0.8 ... 1.2 N·m
Main Circuit 9 mm
M3.5
Pozidriv 2
M3.5
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 9 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 9 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
IEC 60335-2-40 A2L
Technical UL/CSA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Main Circuit 600 V AC
(120 V AC) Single Phase 0.5 Hp
(220 ... 240 V AC) Single Phase 1.5 Hp
(120 V AC) Single Phase 0.5 Hp
(220 ... 240 V AC) Single Phase 1.5 Hp
(120 V AC) Single Phase 9.8 A
(220 ... 240 V AC) Single Phase 10 A
(120 V AC) Single Phase 9.8 A
(220 ... 240 V AC) Single Phase 10 A
(120 V AC) Single Phase 58.8 A
(220 ... 240 V AC) Single Phase 58.8 A
(120 V AC) Single Phase 58.8 A
(220 ... 240 V AC) Single Phase 58.8 A
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Main Circuit 10 ... 12 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
102 mm
50 mm
0.28 kg
4013614485008
carton 40 piece
280 mm
395 mm
210 mm
11.586 kg
4013614487200
External Classifications and Standards
F
EC000228 - Power circuit-breaker for trafo/generator/installation protection
EC000228 - Power circuit-breaker for trafo/generator/installation protection
V11.0 : 27370409
39121601
4864 >> Enclosed 3 Pole Circuit Breakers
3707271
4364109

Environmental
Ordering
8015644202903
1 piece
85389099
Dimensions
180 mm
240 mm
0.19 m
5.028 kg
Container Information
1 piece
240 mm
180 mm
5.028 kg
8015644202903
Additional Information
Spare Parts
Accessory
S3
Isomax
Technical
1 piece
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.25 kg
Technical
4
0
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NO) 25 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
4 kV
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4.5 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.25 kg
4013614524431
48 piece
280 mm
395 mm
210 mm
12.5 kg
4013614538827
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707805

Ordering
1 piece
85365080
Popular Downloads
Dimensions
18 mm
90 mm
75.5 mm
0.1 kg
Technical
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Auxiliary Circuit 6 kV
690 V
132.5 W
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Auxiliary Circuit 0.8 ... 1.2 N·m
Auxiliary Circuit 10 mm
Pozidriv 2
1 ... 6
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-4-1
UL 508
UL 60947-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-4-1
UL 508
UL 60947-1
UL 60947-4-1
Please consider 15 min OFF-period after 5s ON-period.
The mechanical and electrical durability of manual motor starters in combination with UA1/AA1 is reduced. Values are provided on request.
Please consider 15 min OFF-period after 5s ON-period.
The mechanical and electrical durability of manual motor starters in combination with UA1/AA1 is reduced. Values are provided on request.
Technical UL/CSA
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Auxiliary Circuit 7 in·lb
Environmental
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
11 ms Pulse 15g
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
93 mm
25 mm
80 mm
0.11 kg
4013614343308
carton 80 piece
280 mm
395 mm
210 mm
9.175 kg
4013614526046
External Classifications and Standards
Q
EC001023 - Shunt release (for power circuit breaker)
EC001023 - Shunt release (for power circuit breaker)
V11.0 : 27370418
39121601
4879 >> Shunt release (for power circuit breaker)
3705824
4364016

Ordering
1 piece
85365080
Popular Downloads
Dimensions
36 mm
65 mm
85 mm
0.235 kg
Technical
3
1
0
0
4P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(NC) 25 A
(NO) 25 A
(NC) 25 A
(NO) 25 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 6 A
(230 V) Single Phase, NO 9 A
(400 V) Three Phase, NO 9 A
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 1.3 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 5.8 kW
(230 V) Single Phase, NO 5.8 kW
(400 V) Three Phase, NO 17.3 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
(230 V) Single Phase, NC 0.9 kW
(230 V) Single Phase, NO 1.3 kW
(400 V) Three Phase, NO 4 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 72 A
500 V
6 kV
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
AC-1 (NC) 50000 cycle
AC-1 (NO) 130000 cycle
AC-3 (NC) 340000 cycle
AC-3 (NO) 500000 cycle
AC-7a (NC) 50000 cycle
AC-7a (NO) 130000 cycle
AC-7b (NC) 340000 cycle
AC-7b (NO) 500000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
400 ... 415 V
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
Average Holding Value 50 / 60 Hz 4 V·A
Average Holding Value DC 4 W
Average Pull-in Value 50 Hz 4 V·A
Average Pull-in Value 60 Hz 4 V·A
Average Pull-in Value DC 4 W
at Rated Operating Conditions AC-1 per Pole 2 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1.5 ... 10 mm²
Flexible with Ferrule 2x 1.5 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 2x 1.5 mm²
Flexible 1x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 4 mm²
Rigid 1x 1.5 ... 10 mm²
Rigid 2x 1.5 ... 4 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 10 mm
Control Circuit 7 mm
Main Circuit 10 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit Pozidriv 1
Main Circuit Pozidriv 1
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Control Circuit 0.9 N·m
Main Circuit 1 N·m
Screw Terminals
2.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(acc. to UL 240 V) 25 A
(acc. to UL 480 V) 25 A
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
(220 ... 240 V AC) Single Phase, NC 1 Hp
(220 ... 240 V AC) Single Phase, NO 1 Hp
(220 ... 240 V AC) Three Phase, NO 3 Hp
(440 ... 480 V AC) Single Phase, NC 2 Hp
(440 ... 480 V AC) Single Phase, NO 2 Hp
(440 ... 480 V AC) Three Phase, NO 5 Hp
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-8 AWG
Stranded 16-8 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 9 in·lb
Control Circuit 8 in·lb
Main Circuit 9 in·lb
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
(220 ... 240 V AC) Single Phase, NC 9.6 A
(220 ... 240 V AC) Single Phase, NO 9.6 A
(220 ... 240 V AC) Three Phase, NO 9.6 A
(440 ... 480 V AC) Single Phase, NC 7.6 A
(440 ... 480 V AC) Single Phase, NO 7.6 A
(440 ... 480 V AC) Three Phase, NO 7.6 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
39 mm
69.5 mm
0.235 kg
4013614524318
48 piece
280 mm
395 mm
210 mm
11.8 kg
4013614538711
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
4190269

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.37 kg
Technical
2
0
0
0
2P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 63 A
(230 V) Single Phase, NO 30 A
(NO) 63 A
(230 V) Single Phase, NO 30 A
(230 V) Single Phase, NO 14.5 kW
(230 V) Single Phase, NO 5 kW
(230 V) Single Phase, NO 14.5 kW
(230 V) Single Phase, NO 5 kW
8 x Ie / AC-3
10 x Ie / AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 240 A
500 V
6 kV
AC-1 (NO) 100000 cycle
AC-3 (NO) 240000 cycle
AC-7a (NO) 100000 cycle
AC-7b (NO) 240000 cycle
AC-1 (NO) 100000 cycle
AC-3 (NO) 240000 cycle
AC-7a (NO) 100000 cycle
AC-7b (NO) 240000 cycle
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
(AC-1) 300 cycles per hour
(AC-3) 600 cycles per hour
(AC-7a) 300 cycles per hour
(AC-7b) 600 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
24 V
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 60 V·A
Average Pull-in Value 60 Hz 60 V·A
Average Pull-in Value DC 70 W
Average Holding Value 50 / 60 Hz 4.5 V·A
Average Holding Value DC 5 W
Average Pull-in Value 50 Hz 60 V·A
Average Pull-in Value 60 Hz 60 V·A
Average Pull-in Value DC 70 W
at Rated Operating Conditions AC-1 per Pole 4.5 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 1.5 ... 16 mm²
Flexible with Ferrule 2x 1.5 ... 10 mm²
Flexible with Insulated Ferrule 1x 1.5 ... 16 mm²
Flexible with Insulated Ferrule 2x 1.5 ... 10 mm²
Flexible 2x 1.5 ... 10 mm²
Flexible 1x 1.5 ... 16 mm²
Rigid 1x 1.5 ... 25 mm²
Rigid 2x 1.5 ... 10 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.0 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.0 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 4.0 mm²
Flexible 2x 1 ... 2.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 13 mm
Control Circuit 7 mm
Main Circuit 13 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Control Circuit 0.9 N·m
Main Circuit 2.5 N·m
Screw Terminals
3.0
Installation Contactor
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 240 V) 63 A
(acc. to UL 480 V) 63 A
(acc. to UL 240 V) 63 A
(acc. to UL 480 V) 63 A
(220 ... 240 V AC) Single Phase, NO 5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
(220 ... 240 V AC) Single Phase, NO 5 Hp
(440 ... 480 V AC) Single Phase, NO 7.5 Hp
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-4 AWG
Stranded 16-4 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 20 in·lb
Control Circuit 8 in·lb
Main Circuit 20 in·lb
(220 ... 240 V AC) Single Phase, NO 28 A
(440 ... 480 V AC) Single Phase, NO 21 A
(220 ... 240 V AC) Single Phase, NO 28 A
(440 ... 480 V AC) Single Phase, NO 21 A
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Yes
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.37 kg
4013614525247
32 piece
280 mm
395 mm
210 mm
12.2 kg
4013614539640
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707594

Ordering
1 piece
85364900
Popular Downloads
Dimensions
54.9 mm
101.4 mm
106.9 mm
0.372 kg
Technical
36 ... 47 A
Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Main Circuit 440 V DC
Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Main Circuit 440 V DC
47 A
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Auxiliary Circuit 6 kV
Main Circuit 8 kV
Auxiliary Circuit 6 kV
Main Circuit 8 kV
690 V
3P
1
1
3
Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
(120 V) NC 3 A
(120 V) NO 0.5 A
(240 V) NC 3 A
(240 V) NO 0.5 A
(400 V) NC 0.75 A
(400 V) NO 0.5 A
(500 V) NC 0.75 A
(500 V) NO 0.5 A
(120 V) NC 3 A
(120 V) NO 0.5 A
(240 V) NC 3 A
(240 V) NO 0.5 A
(400 V) NC 0.75 A
(400 V) NO 0.5 A
(500 V) NC 0.75 A
(500 V) NO 0.5 A
(125 V) NC 0.55 A
(125 V) NO 0.55 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(500 V) NC 0.15 A
(500 V) NO 0.15 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
(125 V) NC 0.55 A
(125 V) NO 0.55 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(500 V) NC 0.15 A
(500 V) NO 0.15 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 1 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 1 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Flexible with Ferrule 1/2x 2.5 ... 10 mm²
Flexible with Ferrule 1x 2.5 ... 35 mm²
Flexible with Insulated Ferrule 1x 2.5 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 2.5 ... 10 mm²
Flexible 1/2x 2.5 ... 16 mm²
Flexible 1x 2.5 ... 35 mm²
Rigid 1/2x 2.5 ... 16 mm²
Rigid 1x 2.5 ... 35 mm²
Flexible with Ferrule 1/2x 2.5 ... 10 mm²
Flexible with Ferrule 1x 2.5 ... 35 mm²
Flexible with Insulated Ferrule 1x 2.5 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 2.5 ... 10 mm²
Flexible 1/2x 2.5 ... 16 mm²
Flexible 1x 2.5 ... 35 mm²
Rigid 1/2x 2.5 ... 16 mm²
Rigid 1x 2.5 ... 35 mm²
Auxiliary Circuit 1 ... 1.2 N·m
Main Circuit 4.0 ... 4.5 N·m
Auxiliary Circuit 1 ... 1.2 N·m
Main Circuit 4.0 ... 4.5 N·m
Auxiliary Circuit 9 mm
Main Circuit 17 mm
Auxiliary Circuit 9 mm
Main Circuit 17 mm
Auxiliary Circuit Pozidriv 2
Main Circuit Pozidriv 2
Auxiliary Circuit Pozidriv 2
Main Circuit Pozidriv 2
1 ... 6
at Rated Operating Conditions per Pole 2.1 ... 3.6 W
AF40
AF52
AF65
AF40
AF52
AF65
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Technical UL/CSA
Main Circuit 600 V AC
(NC:) B600
(NC:) Q600
(NO:) Q600
(NO:) D300
(NC:) B600
(NC:) Q600
(NO:) Q600
(NO:) D300
Flexible 1x 12-2 AWG
Flexible 2x 12-6 AWG
Stranded 1x 12-2 AWG
Stranded 2x 12-6 AWG
Flexible 1x 12-2 AWG
Flexible 2x 12-6 AWG
Stranded 1x 12-2 AWG
Stranded 2x 12-6 AWG
Flexible 1/2x 18-12 AWG
Stranded 1/2x 18-12 AWG
Flexible 1/2x 18-12 AWG
Stranded 1/2x 18-12 AWG
Auxiliary Circuit 9 ... 11 in·lb
Main Circuit 35 ... 40 in·lb
Auxiliary Circuit 9 ... 11 in·lb
Main Circuit 35 ... 40 in·lb
Environmental
Operation -40 ... +70 °C
Operation Compensated -40 ... +70 °C
Storage -50 ... +80 °C
Operation -40 ... +70 °C
Operation Compensated -40 ... +70 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Material Compliance
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
123 mm
121 mm
82 mm
0.456 kg
4013614482946
12 piece
280 mm
210 mm
395 mm
5.858 kg
4013614485343
External Classifications and Standards
F
EC000106 - Thermal overload relay
EC000106 - Thermal overload relay
V11.0 : 27371501
39122330
5366 >> Thermal overload relay
3706586
4116789
3210266

Ordering
1 piece
85364900
Popular Downloads
Dimensions
45 mm
88.3 mm
70.5 mm
0.13 kg
Technical
0.55 ... 0.74 A
Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Main Circuit 600 V DC
Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Main Circuit 600 V DC
0.74 A
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Auxiliary Circuit 6 kV
Main Circuit 6 kV
Auxiliary Circuit 6 kV
Main Circuit 6 kV
690 V
3P
1
1
3
Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 4 A
(120 V) NC 3 A
(120 V) NO 0.5 A
(240 V) NC 3 A
(240 V) NO 0.5 A
(400 V) NC 0.75 A
(400 V) NO 0.5 A
(500 V) NC 0.75 A
(500 V) NO 0.5 A
(120 V) NC 3 A
(120 V) NO 0.5 A
(240 V) NC 3 A
(240 V) NO 0.5 A
(400 V) NC 0.75 A
(400 V) NO 0.5 A
(500 V) NC 0.75 A
(500 V) NO 0.5 A
(125 V) NC 0.55 A
(125 V) NO 0.55 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(500 V) NC 0.15 A
(500 V) NO 0.15 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
(125 V) NC 0.55 A
(125 V) NO 0.55 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(500 V) NC 0.15 A
(500 V) NO 0.15 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
IP20
3
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 1 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible 1/2x 0.75 ... 1 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²
Flexible 1/2x 0.75 ... 4 mm²
Rigid 1/2x 0.75 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 4 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 4 mm²
Flexible 1/2x 0.75 ... 4 mm²
Rigid 1/2x 0.75 ... 4 mm²
Auxiliary Circuit 1 ... 1.2 N·m
Main Circuit 1.5 ... 2.5 N·m
Auxiliary Circuit 1 ... 1.2 N·m
Main Circuit 1.5 ... 2.5 N·m
Auxiliary Circuit 9 mm
Main Circuit 12 mm
Auxiliary Circuit 9 mm
Main Circuit 12 mm
Main Circuit Pozidriv 2
at Rated Operating Conditions per Pole 1.1 ... 2.0 W
AF09
AF12
AF16
AF26
AF30
AF38
AF09
AF12
AF16
AF26
AF30
AF38
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Technical UL/CSA
Main Circuit 600 V AC
(NC:) B600
(NC:) Q600
(NO:) Q600
(NO:) D300
(NC:) B600
(NC:) Q600
(NO:) Q600
(NO:) D300
Flexible 1/2x 18-10 AWG
Stranded 1/2x 18-10 AWG
Flexible 1/2x 18-10 AWG
Stranded 1/2x 18-10 AWG
Flexible 1/2x 18-12 AWG
Stranded 1/2x 18-12 AWG
Flexible 1/2x 18-12 AWG
Stranded 1/2x 18-12 AWG
Auxiliary Circuit 9 ... 11 in·lb
Main Circuit 13 ... 22 in·lb
Auxiliary Circuit 9 ... 11 in·lb
Main Circuit 13 ... 22 in·lb
Environmental
Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Material Compliance
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
carton 1 piece
48 mm
92 mm
78 mm
0.145 kg
4013614398032
carton 40 piece
280 mm
210 mm
395 mm
7.346 kg
4013614440076
External Classifications and Standards
F
EC000106 - Thermal overload relay
EC000106 - Thermal overload relay
V11.0 : 27371501
39122330
5366 >> Thermal overload relay
3706116
4116757
3211960

Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
97.8 mm
86.55 mm
0.31 kg
Technical
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
300 A
16 ... 20 A
(400 V) Three Phase 7.5 kW
(400 V) Three Phase 7.5 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
20 A
20 A
20 A
20 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 1.5 ... 2.3 W
3P
Main Circuit 20 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Main Circuit 2 N·m
Main Circuit 10 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 5 Hp
(208 V AC) Three Phase 5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 15 Hp
(200 V AC) Three Phase 5 Hp
(208 V AC) Three Phase 5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 15 Hp
(200 V AC) Three Phase 17.5 A
(208 V AC) Three Phase 16.7 A
(220 ... 240 V AC) Three Phase 15.2 A
(440 ... 480 V AC) Three Phase 14 A
(550 ... 600 V AC) Three Phase 17 A
(200 V AC) Three Phase 17.5 A
(208 V AC) Three Phase 16.7 A
(220 ... 240 V AC) Three Phase 15.2 A
(440 ... 480 V AC) Three Phase 14 A
(550 ... 600 V AC) Three Phase 17 A
(200 V AC) Three Phase 105.8 A
(208 V AC) Three Phase 102 A
(220 ... 240 V AC) Three Phase 92 A
(440 ... 480 V AC) Three Phase 81 A
(550 ... 600 V AC) Three Phase 93 A
(200 V AC) Three Phase 105.8 A
(208 V AC) Three Phase 102 A
(220 ... 240 V AC) Three Phase 92 A
(440 ... 480 V AC) Three Phase 81 A
(550 ... 600 V AC) Three Phase 93 A
(600 V AC) 20 A
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Main Circuit 18 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
102 mm
50 mm
0.325 kg
4013614400131
carton 40 piece
280 mm
395 mm
210 mm
13.386 kg
4013614409035
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3705997
4364081
3112128

Ordering
1 piece
85365080
Popular Downloads
Dimensions
54 mm
65 mm
85 mm
0.405 kg
Technical
2
0
0
0
2P
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 61095
UL 60947-1
UL 60947-4-1
Main Circuit 220 V DC
Main Circuit 400 V AC
Main Circuit 220 V DC
Main Circuit 400 V AC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
Control Circuit 400 Hz
Control Circuit 50 Hz
Control Circuit 60 Hz
Control Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit DC
(NO) 100 A
(NO) 100 A
(230 V) Single Phase, NO 23 kW
(230 V) Single Phase, NO 23 kW
500 V
6 kV
AC-1 (NO) 50000 cycle
AC-7a (NO) 50000 cycle
AC-1 (NO) 50000 cycle
AC-7a (NO) 50000 cycle
(AC-1) 150 cycles per hour
(AC-7a) 150 cycles per hour
(AC-1) 150 cycles per hour
(AC-7a) 150 cycles per hour
Nr. Operations 1000000 cycle
(acc. to IEC 60947-4-1) 0.85 ... 1.1 x Uc (at θ ≤ 55 °C)
230 V
Average Holding Value 50 / 60 Hz 7.5 V·A
Average Holding Value DC 8.5 W
Average Pull-in Value 50 Hz 90 V·A
Average Pull-in Value 60 Hz 90 V·A
Average Pull-in Value DC 100 W
Average Holding Value 50 / 60 Hz 7.5 V·A
Average Holding Value DC 8.5 W
Average Pull-in Value 50 Hz 90 V·A
Average Pull-in Value 60 Hz 90 V·A
Average Pull-in Value DC 100 W
at Rated Operating Conditions per Pole 4.2 W
at Rated Operating Conditions AC-1 per Pole 6 W
at Rated Operating Conditions per Pole 4.2 W
at Rated Operating Conditions AC-1 per Pole 6 W
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Flexible with Ferrule 1x 10 ... 35 mm²
Flexible with Insulated Ferrule 1x 10 ... 35 mm²
Flexible 1x 10 ... 35 mm²
Rigid 1x 10 ... 50 mm²
Flexible with Ferrule 1x 10 ... 35 mm²
Flexible with Insulated Ferrule 1x 10 ... 35 mm²
Flexible 1x 10 ... 35 mm²
Rigid 1x 10 ... 50 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Flexible with Ferrule 1x 1 ... 2.5 mm²
Flexible with Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 1 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1 mm²
Flexible 1x 1 ... 2.5 mm²
Flexible 2x 1 ... 1.5 mm²
Rigid 1x 1 ... 4 mm²
Rigid 2x 1 ... 2.5 mm²
Control Circuit 7 mm
Main Circuit 15 mm
Control Circuit 7 mm
Main Circuit 15 mm
IP20
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit Pozidriv 1
Main Circuit Pozidriv 2
Control Circuit 0.9 N·m
Main Circuit 3 N·m
Control Circuit 0.9 N·m
Main Circuit 3 N·m
Screw Terminals
3.0
Installation Contactors
Technical UL/CSA
Main Circuit 480 V AC
(acc. to UL 480 V) 100 A
Solid 8-0 AWG
Stranded 8-0 AWG
Solid 8-0 AWG
Stranded 8-0 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Solid 16-10 AWG
Stranded 16-10 AWG
Control Circuit 8 in·lb
Main Circuit 27 in·lb
Control Circuit 8 in·lb
Main Circuit 27 in·lb
Environmental
Operation -25 ... +55 °C
Storage -40 ... +80 °C
Operation -25 ... +55 °C
Storage -40 ... +80 °C
2000 m
11 ms Pulse 15g
3
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Consumer
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
57 mm
69.5 mm
0.405 kg
4013614533037
External Classifications and Standards
Q
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
EC001653 - Installation contactor for distribution board
V11.0 : 27142308
39121529
4759 >> Installation contactor for distribution board
3707802
3210575

Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
90 mm
86.75 mm
0.265 kg
Technical
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
125 A
None
(400 V) Three Phase 4 kW
(400 V) Three Phase 4 kW
Main Circuit 690 V AC
10 A
10 A
10 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 2.2 W
3P
Main Circuit 10 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Main Circuit 0.8 ... 1.2 N·m
Main Circuit 9 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
(600 V AC) 10 A
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Main Circuit 10 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
No
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
95 mm
50 mm
0.28 kg
4013614400254
carton 40 piece
280 mm
395 mm
210 mm
11.586 kg
4013614443701
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3705888
4364094
3110038

Material Compliance
Environmental
Ordering
Dimensions
76 mm
130 mm
70 mm
1 kg
Container Information
1 piece
128 mm
135 mm
143 mm
1.11 kg
8015644513351
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
CB
T1
Moulded Case Circuit Breakers
F
Technical
8000 cycle
120 cycles per hour
8000 cycle
120 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
3P
at Rated Operating Conditions per Pole 10,7 W
125 A
8 kV
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
160 A
TMD
TM
N
IEC 60947
T1
Fixed Circuit-Breakers
Front for Copper Cables
Fixed Circuit-Breakers
Front for Copper Cables
3000 V
3000 V
Certificates and Declarations
External Classifications and Standards
Q
39121100

Material Compliance
Environmental
Ordering
Dimensions
76 mm
130 mm
70 mm
1 kg
Container Information
1 piece
128 mm
135 mm
143 mm
1.11 kg
8015644513344
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
CB
T1
Moulded Case Circuit Breakers
F
Technical
8000 cycle
120 cycles per hour
8000 cycle
120 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
3P
at Rated Operating Conditions per Pole 7 W
100 A
8 kV
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
160 A
TMD
TM
N
IEC 60947
T1
Fixed Circuit-Breakers
Front for Copper Cables
Fixed Circuit-Breakers
Front for Copper Cables
3000 V
3000 V
Certificates and Declarations
External Classifications and Standards
Q
39121100

Ordering
1 piece
85364900
Popular Downloads
Dimensions
44.4 mm
74.6 mm
57 mm
0.15 kg
Technical
0.80 ... 2.7 A
Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
Auxiliary Circuit 600 V AC/DC
Main Circuit 690 V AC
2.7 A
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 50 Hz
Main Circuit 60 Hz
Auxiliary Circuit 6 kV
Main Circuit 6 kV
Auxiliary Circuit 6 kV
Main Circuit 6 kV
690 V
3P
1
1
3
Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 6 A
Auxiliary Circuit NC 6 A
Auxiliary Circuit NO 6 A
(240 V) NC 3 A
(240 V) NO 3 A
(400 V) NC 1.1 A
(400 V) NO 1.1 A
(500 V) NC 0.72 A
(500 V) NO 0.72 A
(240 V) NC 3 A
(240 V) NO 3 A
(400 V) NC 1.1 A
(400 V) NO 1.1 A
(500 V) NC 0.72 A
(500 V) NO 0.72 A
(125 V) NC 0.55 A
(125 V) NO 0.5 A
(24 V) NC 1.5 A
(24 V) NO 1.5 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
(125 V) NC 0.55 A
(125 V) NO 0.5 A
(24 V) NC 1.5 A
(24 V) NO 1.5 A
(250 V) NC 0.27 A
(250 V) NO 0.27 A
(60 V) NC 0.55 A
(60 V) NO 0.55 A
IP20
3
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Auxiliary Circuit 0.8 ... 1.2 N·m
Main Circuit 0.8 ... 1.5 N·m
Auxiliary Circuit 0.8 ... 1.2 N·m
Main Circuit 0.8 ... 1.5 N·m
Auxiliary Circuit 9 mm
Main Circuit 9 mm
Auxiliary Circuit 9 mm
Main Circuit 9 mm
Auxiliary Circuit Pozidriv 2
Main Circuit Pozidriv 2
Auxiliary Circuit Pozidriv 2
Main Circuit Pozidriv 2
1 ... 6
at Rated Operating Conditions per Pole 0.005 ... 0.058 W
B6
B7
BC6
BC7
A09
A12
A16
AL09
AL12
AL16
VB6
VB7
VBC6
VBC7
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Technical UL/CSA
Main Circuit 600 V AC
B600
Q300
B600
Q300
Flexible 1/2x 16-10 AWG
Stranded 1/2x 16-10 AWG
Flexible 1/2x 16-10 AWG
Stranded 1/2x 16-10 AWG
Flexible 1/2x 16-10 AWG
Stranded 1/2x 16-10 AWG
Flexible 1/2x 16-10 AWG
Stranded 1/2x 16-10 AWG
Auxiliary Circuit 7 in·lb
Main Circuit 7 in·lb
Auxiliary Circuit 7 in·lb
Main Circuit 7 in·lb
Environmental
Operation -25 ... +70 °C
Operation Compensated -25 ... +70 °C
Storage -50 ... +85 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +70 °C
Storage -50 ... +85 °C
Yes
2000 m
11 ms Pulse 15g
5g 3 ... 150 Hz
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Material Compliance
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
65 mm
46 mm
76.5 mm
0.17 kg
4013614395246
External Classifications and Standards
F
EC001080 - Electronic overload relay
EC001080 - Electronic overload relay
V11.0 : 27371502
39122330
5365 >> Electronic overload relay
3709392
4116947
3228762

Ordering
1 piece
85371098
HF
Electronic Starter
Popular Downloads
Dimensions
22.5 mm
99 mm
114.5 mm
0.218 kg
Technical
IEC/EN 60947-1
IEC/EN 60947-4-2
UL 60947-1
UL 60947-4-2
IEC/EN 60947-1
IEC/EN 60947-4-2
UL 60947-1
UL 60947-4-2
Reversed-on-line starter with overload protection
Motor Protection
Main Circuit 500 V AC
Maximum 550 V AC
Minimum 42 V AC
Maximum 550 V AC
Minimum 42 V AC
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
24 V DC
Switching Threshold at Signal <0> -3 ... 9.6 V
Switching Threshold at Signal <1> 19.2 ... 30 V
Switching Threshold at Signal <0> -3 ... 9.6 V
Switching Threshold at Signal <1> 19.2 ... 30 V
Main Circuit 6 kV
500 V
9 A
6.5 A
0.04 A
9 A
0.003 A
≤ 2 Hz
120 starts/min
7200 starts/h
≤ 2 Hz
120 starts/min
7200 starts/h
3 kW
III
Electronic overload protection
1.5 ... 9.0 A
class 10A
3P
Maximum 14.6 W
Minimum 1.1 W
Maximum 14.6 W
Minimum 1.1 W
3
Nr. Operations 10000 cycle
30000000 cycle
Off, Maximum, Switched Off via Supply Voltage 500 ms
Off, Typical, Switched Off via Control Input Voltage 30 ms
Off, Typical, Switched Off via Supply Voltage 25 ms
Off, Maximum, Switched Off with Pushbutton 3 second [unit of time]
Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time]
Off, Maximum, Switched Off via Supply Voltage 500 ms
Off, Typical, Switched Off via Control Input Voltage 30 ms
Off, Typical, Switched Off via Supply Voltage 25 ms
Off, Maximum, Switched Off with Pushbutton 3 second [unit of time]
Off, Minimum, Switched Off with Pushbutton 0.5 second [unit of time]
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
1
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1x 0.5 ... 4 mm²
Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1x 0.5 ... 4 mm²
Flexible with Ferrule 1x 2 ... 2.5 mm²
Flexible 1x 2 ... 2.5 mm²
Rigid 1x 2 ... 2.5 mm²
Flexible with Ferrule 1x 2 ... 2.5 mm²
Flexible 1x 2 ... 2.5 mm²
Rigid 1x 2 ... 2.5 mm²
Control Circuit M3
Main Circuit M3
Control Circuit M3
Main Circuit M3
Screw Terminals
Control Circuit 0.5 ... 0.6 N·m
Main Circuit 0.5 ... 0.6 N·m
Control Circuit 0.5 ... 0.6 N·m
Main Circuit 0.5 ... 0.6 N·m
Control Circuit 8 mm
Main Circuit 8 mm
Control Circuit 8 mm
Main Circuit 8 mm
Phase Asymmetry 33% 120 second [unit of time]
Phase Asymmetry 67% 1.8 second [unit of time]
Phase Failure 1.8 second [unit of time]
Phase Asymmetry 33% 120 second [unit of time]
Phase Asymmetry 67% 1.8 second [unit of time]
Phase Failure 1.8 second [unit of time]
2
Yes
Housing IP20
Main Circuit Terminals IP20
Housing IP20
Main Circuit Terminals IP20
(500 V AC, 30 A Class J or CC) 100 kA
Technical UL/CSA
Main Circuit 500 V AC
Nominal Switching Performance Full Load (power factor = 0.4) 3 Hp
Nominal Switching Performance Full Load (power factor = 0.8) 6.1 Hp
Nominal Switching Performance Full Load (power factor = 0.4) 3 Hp
Nominal Switching Performance Full Load (power factor = 0.8) 6.1 Hp
6.5 A
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 1x 24 ... 14 AWG
Solid 1x 24 ... 14 AWG
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 1x 24 ... 14 AWG
Solid 1x 24 ... 14 AWG
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 16-8 AWG
Solid 1x 24 ... 14 AWG
Flexible with Ferrule 1x 24 ... 14 AWG
Flexible 16-8 AWG
Solid 1x 24 ... 14 AWG
Control Circuit 5 ... 7 in·lb
Main Circuit 5 ... 7 in·lb
Control Circuit 5 ... 7 in·lb
Main Circuit 5 ... 7 in·lb
Safety Information
39.6 year
Environmental
Operation -25 ... +70 °C
Operation Compensated -40 ... + 80 °C
Operation -25 ... +70 °C
Operation Compensated -40 ... + 80 °C
Without Derating 2000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
150 mm
115 mm
34 mm
0.318 kg
4013614515569
External Classifications and Standards
B
EC001037 - Motor starter/motor starter combination
EC001037 - Motor starter/motor starter combination
V11.0 : 27370905
39121521
4727 >> Motor starter controls
3707549
4102015
3210497

Ordering
1 piece
85364900
Popular Downloads
Dimensions
104 mm
151 mm
126 mm
0.77 kg
Technical
130 ... 175 A
Auxiliary Circuit 440 V DC
Auxiliary Circuit 500 V AC
Main Circuit 690 V AC
Main Circuit 440 V DC
Auxiliary Circuit 440 V DC
Auxiliary Circuit 500 V AC
Main Circuit 690 V AC
Main Circuit 440 V DC
175 A
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit DC
Auxiliary Circuit 6 kV
Main Circuit 6 kV
Auxiliary Circuit 6 kV
Main Circuit 6 kV
690 V
3P
1
1
3
Auxiliary Circuit NC 10 A
Auxiliary Circuit NO 6 A
Auxiliary Circuit NC 10 A
Auxiliary Circuit NO 6 A
(120 V) NC 3 A
(120 V) NO 1.5 A
(240 V) NC 3 A
(240 V) NO 1.2 A
(400 V) NC 0.75 A
(400 V) NO 0.37 A
(440 V) NC 0.75 A
(440 V) NO 0.37 A
(500 V) NC 0.3 A
(500 V) NO 0.25 A
(120 V) NC 3 A
(120 V) NO 1.5 A
(240 V) NC 3 A
(240 V) NO 1.2 A
(400 V) NC 0.75 A
(400 V) NO 0.37 A
(440 V) NC 0.75 A
(440 V) NO 0.37 A
(500 V) NC 0.3 A
(500 V) NO 0.25 A
(125 V) NC 0.25 A
(125 V) NO 0.25 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.12 A
(250 V) NO 0.04 A
(60 V) NC 0.25 A
(60 V) NO 0.25 A
(125 V) NC 0.25 A
(125 V) NO 0.25 A
(24 V) NC 1.25 A
(24 V) NO 1.25 A
(250 V) NC 0.12 A
(250 V) NO 0.04 A
(60 V) NC 0.25 A
(60 V) NO 0.25 A
Housing IP20
Main Circuit Terminals IP00
Housing IP20
Main Circuit Terminals IP00
3
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 0.75 ... 4 mm²
Hole Diameter > 10 mm²
Rigid or Flexible with Cable Lug 1x 25 ... 120 mm²
Hole Diameter > 10 mm²
Rigid or Flexible with Cable Lug 1x 25 ... 120 mm²
Auxiliary Circuit 1 ... 1.3 N·m
Main Circuit 25 N·m
Auxiliary Circuit 1 ... 1.3 N·m
Main Circuit 25 N·m
Auxiliary Circuit 9 mm
Auxiliary Circuit Pozidriv 1
Main Circuit Open Bars
Auxiliary Circuit Pozidriv 1
Main Circuit Open Bars
1 ... 6
at Rated Operating Conditions per Pole 3.8 ... 6.9 W
A145
A185
AF145
AF185
AF190
AF205
A145
A185
AF145
AF185
AF190
AF205
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
Technical UL/CSA
Main Circuit 600 V AC
(NO:) B600
(NC:) C600
(NO:) B600
(NC:) C600
Flexible 1x 4-0000 AWG
Stranded 1x 4-0000 AWG
Flexible 1x 4-0000 AWG
Stranded 1x 4-0000 AWG
Flexible 1/2x 18-14 AWG
Stranded 1/2x 18-14 AWG
Flexible 1/2x 18-14 AWG
Stranded 1/2x 18-14 AWG
Auxiliary Circuit 12 in·lb
Main Circuit 220 in·lb
Auxiliary Circuit 12 in·lb
Main Circuit 220 in·lb
Environmental
Operation -5 ... +40 °C
Operation Compensated -5 ... +40 °C
Storage -40 ... +70 °C
Operation -5 ... +40 °C
Operation Compensated -5 ... +40 °C
Storage -40 ... +70 °C
Yes
2000 m
11 ms Pulse 12g
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Material Compliance
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
165 mm
133 mm
151 mm
1.02 kg
4013614305948
4 piece
280 mm
210 mm
395 mm
8.786 kg
4013614494338
External Classifications and Standards
F
EC000106 - Thermal overload relay
EC000106 - Thermal overload relay
V11.0 : 27371501
39121520
5364 >> Overload relay

Material Compliance
Environmental
Ordering
4377342
8015644518264
1 piece
85389099
Dimensions
1.18 kg
Container Information
1 piece
210 mm
170 mm
240 mm
1.28 kg
8015644518264
Additional Information
Accessories for Tmax T
Accessory
ACC
T2
SACE Tmax T
Technical
Loose or configurable
T2
4P
IEC
Certificates and Declarations
External Classifications and Standards
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)

Environmental
Ordering
8015644137823
1 piece
85389099
Dimensions
110 mm
60 mm
0.14 m
0.132 kg
Container Information
1 piece
60 mm
110 mm
0.132 kg
8015644137823
Additional Information
Spare Parts
Accessory
S3
S4
S5
S3
S4
S5
Isomax
Technical
S3-S4-S5
Certificates and Declarations
External Classifications and Standards
Q
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Environmental
Ordering
4377341
8015644518257
1 piece
85389099
Dimensions
1.18 kg
Container Information
1 piece
210 mm
170 mm
240 mm
1.28 kg
8015644518257
Additional Information
Accessories for Tmax T
Accessory
ACC
T2
SACE Tmax T
Technical
Loose or configurable
T2
4P
IEC
Certificates and Declarations
External Classifications and Standards
Q
39121100
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Environmental
Ordering
Dimensions
102 mm
130 mm
70 mm
1.3 kg
Container Information
1 piece
128 mm
135 mm
143 mm
1.4 kg
8015644513450
Additional Information
SACE Tmax T
Moulded Case Circuit Breaker
CB
T1
Moulded Case Circuit Breakers
F
Technical
8000 cycle
120 cycles per hour
8000 cycle
120 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
240 cycles per hour
4P
at Rated Operating Conditions per Pole 7 W
100 A
8 kV
800 V
690 V AC
500 V DC
690 V AC
500 V DC
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 37,5 kA
(230 V AC) 37,5 kA
(380 V AC) 27 kA
(400 V AC) 27 kA
(415 V AC) 27 kA
(440 V AC) 11 kA
(500 V AC) 7,5 kA
(690 V AC) 3 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 5 kA
(230 V AC) 5 kA
(380 V AC) 36 kA
(400 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 22 kA
(500 V AC) 15 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(250 V DC) 3 Poles in Series 40 kA
160 A
TMD
TM
N
IEC 60947
T1
Fixed Circuit-Breakers
Front for Copper Cables
Fixed Circuit-Breakers
Front for Copper Cables
3000 V
3000 V
Certificates and Declarations
External Classifications and Standards
Q
39121100