Distance & Measurement Sensors

504 products

Showing 73 - 96 of 504 products

Showing 73 - 96 of 504 products
View
Keyence Stock Image
Keyence LR-XN11N Keyence
Sale price $301.16
Only 6 units left

Specifications

Model

LR-XN11N

Type

NPN Output

Cable/Connector

Cable

Main Unit/Expansion Unit

Main Unit

No. of Control Outputs

2

No. of External Inputs

1

Response Time

500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable

IO-Link

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

Open collector, 30 VDC or lower, N.O./N.C.
When used as a solitary unit: 100 mA or lower for 1 output; 100 mA or lower in total for 2 outputs; When expanding with multiple units: 50 mA or lower for 1 output
Residual voltage NPN: 1.4 V or lower (output current: 10 mA or lower)/2 V or lower (output current: 10 to 100 mA)

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable
Short circuit current - NPN: 1 mA or lower
Input time: 3 ms or more ON, 20 ms or more OFF (25 ms or more ON, 25 ms or more OFF only when External Set is selected)

Unit Expansion

Up to 8 expansion units possible (including main unit, a total of 9 units connected) However, up to 16-unit expansion is possible when the LR-XN10 is used for expansion with the NU Series.

Protection Circuit

Protection against reverse power connection, protection against output overcurrent, protection against output surge, protection against reverse output connection

Number of Interference Prevention Devices

OFF/4 units/8 units selectable*2

Power supply

Power voltage

16 to 30 VDC*3 (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 1060 mW (44 mA or lower at 24 V, 61 mA or lower at 16 V), ECO ON/ALL: 895 mW (37 mA or lower at 24 V, 50 mA or lower at 16 V) (excluding Load Current)

Environmental resistance

Ambient temperature

−20 to +55°C -4°F to 131°F (no freezing)*4

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 (50G); 3 times each for X, Y, and Z axes

Case Material

Main Unit and Cover: Polycarbonate

Accessories

Instruction manual

Weight

Approx. 80 g

*1 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
· The interference prevention function is not supported
*2 Selecting four or eight interference prevention units causes the response time to change as follows: 4 Units selected: 6 ms/18 ms/60 ms/1.2 s selectable; 8 Units selected: 12 ms/36 ms/120 ms/2.4 s selectable.
*3 When expanding the system with 4 or more expansion units, use a power voltage of 20 V or higher.
*4 Expansion by 1 or 2 units: −20 to +55°C -4°F to 131°F; Expansion by 3 to 10 units: -20 to +50°C -4°F to 122°F, Expansion by 11 to 16 units: -20 to +45°C -4°F to 113°F

Keyence Stock Image
Keyence LJ-X8400 Keyence
Sale price $14,272.94
Only 5 units left

Specifications

Model

LJ-X8400

Reference distance

380 mm 14.96"

Measurement range

Z-axis (height)

±60 mm ±2.36" (+95 to -220 mm +3.74" to -8.66" *1) (F.S.=315 mm 12.40")

X-axis (width)

NEAR side

180 mm 7.09" (163 mm 6.42" *1)

Reference distance

210 mm 8.27"

FAR side

240 mm 9.45" (320 mm 12.60" *1)

Light source

Blue semiconductor laser

Light source

Wavelength

405 nm (visible light)

Laser class

Class 2M laser product (IEC60825-1, FDA (CDRH) Part 1040.10 *2) *3

Output

10 mW

Spot size

Approx. 275 mm × 249 μm 10.83" × 0.0098" (reference distance)

Repeatability

Z-axis (height)

5 μm 0.000197" *4*5

X-axis (width)

10 μm 0.0004" *4*6

Linearity

Z-axis (height)

Reference distance: ±60 mm ±2.36" ±0.025% of F.S. (±0.003%)
Total range: ±0.035% of F.S. (±0.005%) *7

Profile data interval

X-axis (width)

75 μm 0.0030" (50 μm 0.0020"~)
100 μm 0.0039" (50 μm 0.0020"~) *1 *8

Profile data count

3200 points

HDR (high dynamic range)

Single-shot HDR *9

Laser irradiation position confirmation function

Light source

Blue LED (405 nm)

Temperature characteristic

0.01% of F.S./°C

Environmental resistance

Enclosure rating

IP67 (IEC60529) *10

Ambient light

Incandescent lamp: 10,000 lux or less *11

Ambient temperature

0 to +45°C 32 to +113°F *12

Relative humidity

85% RH or less (no condensation)

Vibration resistance

10 to 57 Hz, double amplitude 1.5 mm 0.06"; 3 hours each for X, Y, and Z axes

Shock resistance

15 G / 6 msec

Material

Aluminum

Weight

Approx. 1300 g 2.87 lb

*1 When range is extended.
*2 Classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*3 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*4 Values measured by averaging 4096 times at the reference distance.
*5 The measured target is a KEYENCE standard target. Value when the average height of the default setting area is measured with height and position tools. All other settings are default values.
*6 The measured target is a pin gauge. Value when the point of intersection for the pin gauge rounded surface and edge level is measured using height and position tools. All other settings are default values.
*7 The measured target is a KEYENCE standard target. Profile data when measured by smoothing 64 times and averaging 8 times. All other settings are default values. Values inside parentheses are representative examples of averages for all profile data.
*8 The profile data interval can be changed. If changed, the measurement range in the X direction will also change.
*9 A characteristic that allows for stable, high-precision measurement with a single capture (exposure) at all levels of reflectance, from black (low) to glossy surfaces (high).
*10 The value when a head cable (CB-B*) or extension cable (CB-B*E) is connected. Does not include CB-B**L connection.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

keyence Stock Image
Keyence LJ-H1X Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Sick New Stock Image
Sick OD1-B035H15U25 DISPLAC. SENS, OPTICAL Sick
Sale price $800.00
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick Stock Image
Sick OD250-150P142 Sick
Sale price $1,132.45
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD1-B035H15A15 DISPLAC. SENS, OPTICAL Sick
Sale price $2,991.80
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD1-B100C50I14 DISPLAC. SENS, OPTICAL Sick
Sale price $1,549.98
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD5-350W100 DISPLAC. SENS, OPTICAL Sick
Sale price $1,305.00
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick Stock Image
Sick OD85-20T1 Sick
Sale price $5,467.00
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD2000-2452T15 DISTANCE SCANNER Sick
Sale price $2,073.50
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed