Main
| Characteristic | Value(s) |
|---|---|
| Range Compatibility | Lexium 62 ILM Lexium 62 Lexium 52 Lexium 32 Lexium 32i |
| Gear box type | Straight teeth |
| Product or Component Type | Angular planetary gearbox |
| Device short name | GBY |
| Product compatibility | BMI 3.9 in (100 mm), 2 BMH 3.9 in (100 mm), 2 BMH 3.9 in (100 mm), 3 BSH 3.9 in (100 mm), 2 SH3 MH3 ILM |
| Gearbox external diameter | 4.7 in (120 mm) |
| Reduction ratio | 8:1 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Maximum torsional backlash | 11 arc.min |
| Torsional rigidity | 12 N.m/arcmin |
| Housing Colour | Black |
| Housing material | Black anodized aluminium |
| Shaft material | C 45 |
| Additional information | Lubricated for life |
| Service life in hours | 30000 h 100 rpm 86 °F (30 °C) |
| Mounting position | Any position |
| Efficiency | 95.0 % |
| Maximum radial force Fr | 1500 N 100 rpm, force applied at mid-distance from output shaft during 30000 hour at 30 °C |
| Maximum axial force Fa | 2100 N 100 rpm, during 30000 hour at 30°C |
| moment of inertia | 2.846 kg.cm² |
| Continuous output torque | 1062.09 lbf.in (120 N.m) 100 rpm 86 °F (30 °C) |
| Maximum output torque | 1699.3 lbf.in (192 N.m) 100 rpm 86 °F (30 °C) |
| Product Weight | 26.5 lb(US) (12 kg) |
| Input diameter | 0.9 in (24.0 mm) |
| No load running torque | 2.7 lbf.in (0.3 N.m) |
| Reduction ratio | 8 |
| Compatibility code | GBY |
| Internal length | 7.7 in (194.5 mm) |

This is a standard motor mechanism for Compact NSX 250 and PowerPact Multistandard J frame devices that allows automatic device spring-charging. It helps the circuit breaker to feature a high mechanical endurance as well as easy and sure opening or closing operations. It provides a double insulation of the front face and all indications remain visible and accessible. The control voltage of this motor mechanism module is 380VAC to 415VAC 50/60Hz or 440VAC to 480VAC 60Hz. The consumption is less than 500VA. Padlocking of the device remains possible. The motor mechanism is supplied with SDE adapter.
Main
| Characteristic | Value(s) |
|---|---|
| Device short name | MT250 |
| Product or Component Type | Motor mechanism |
| Device Application | Automatic spring charging |
| Range compatibility | ComPacT NSX250 ComPacT NSX250 DC |
| Control Type | Standard |
| [Uc] control circuit voltage | 380...415 V AC 50/60 Hz 440...480 V AC 60 Hz |
| circuit breaker mounting mode | Fixed |
| circuit breaker frame rated current | 250 A |
Complementary
| Characteristic | Value(s) |
|---|---|
| Control signal type | Maintained Impulse |
| circuit breaker response time | < 700 ms open < 80 ms closed |
| Maximum operating frequency | 4 per minute |
| Maximum power consumption in VA | 500 VA closing 500 VA opening |
| Provided Equipment | SDE adaptor |
| Locking options description | 1 to 3 padlocks à 5 to à 8 Padlocking in OFF position |

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.



circuit breaker basic frame, Compact NSX250L, 150 kA at 415 VAC 50/60 Hz, 250 A, without trip unit, 3 poles

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | INF200...800 |
| Range | FuPact |
| product name | Fupact INF |
| Device short name | INFD250 |
| Product or component type | Switch-disconnector-fuse |
| Device application | Protection |
| Poles description | 4P |
| Protected poles description | 4f |
| Fuse type | DIN |
| Fuse size | NH0 NH1 |
| Network type | DC AC |
| Network frequency | 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| control type | Operating shaft (without handle) |
| Rotary handle mounting location | Front |
| Mounting mode | Fixed |
| Mounting support | Mounting plate |
| [Ie] rated operational current | AC-22A: 250 A at 220/240 V AC 50/60 Hz AC-22A: 250 A at 380/415 V AC 50/60 Hz AC-22A: 250 A at 440/480 V AC 50/60 Hz AC-22A: 250 A at 500/525 V AC 50/60 Hz AC-22A: 250 A at 660/690 V AC 50/60 Hz AC-23A: 250 A at 220/240 V AC 50/60 Hz AC-23A: 250 A at 380/415 V AC 50/60 Hz AC-23A: 250 A at 440/480 V AC 50/60 Hz AC-23A: 250 A at 500/525 V AC 50/60 Hz AC-23A: 250 A at 660/690 V AC 50/60 Hz DC-22A: 250 A at 250 V DC (2 poles in series) DC-22A: 250 A at 500 V DC (3 poles in series) DC-23A: 250 A at 250 V DC (2 poles in series) DC-23A: 250 A at 500 V DC (3 poles in series) AC-22A: 250 A at 480 V AC 50/60 Hz conforming to NEMA AC-23A: 250 A at 480 V AC 50/60 Hz conforming to NEMA DC-22A: 250 A at 125 V DC (1 pole) DC-23A: 250 A at 125 V DC (1 pole) DC-22A: 230 A at 750 V DC (4 poles in series) DC-23A: 230 A at 750 V DC (4 poles in series) |
| [Ith] conventional free air thermal current | 200 A ( 60 °C ) vertical 250 A ( 40 °C ) power dissipation per fuse: 23 W vertical 177 A ( 70 °C ) horizontal 177 A ( 70 °C ) vertical 189 A ( 65 °C ) horizontal 189 A ( 65 °C ) vertical 200 A ( 60 °C ) horizontal 211 A ( 55 °C ) horizontal 211 A ( 55 °C ) vertical 222 A ( 50 °C ) horizontal 222 A ( 50 °C ) vertical 231 A ( 45 °C ) horizontal 232 A ( 45 °C ) vertical 241 A ( 40 °C ) horizontal 250 A ( 35 °C ) horizontal |
| [Ithe] conventional enclosed thermal current | 230 A at 40 °C, Power dissipation per fuse: 27 W (800 mm x 400 mm x 330 mm) 250 A at 40 °C, Power dissipation per fuse: 20 W (800 mm x 400 mm x 330 mm) |
| Maximum power | AC-23: 140 kW at 380/400 V AC 50/60 Hz AC-23: 145 kW at 415 V AC 50/60 Hz AC-23: 170 kW at 500/525 V AC 50/60 Hz AC-23: 250 kW at 660/690 V AC 50/60 Hz AC-23: 75 kW at 220/240 V AC 50/60 Hz |
| Rated duty | Uninterrupted |
| [Ui] rated insulation voltage | 1000 V AC 50/60 Hz 1000 V DC |
| [Uimp] rated impulse withstand voltage | 12 kV |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz 1000 V AC 50/60 Hz AC-20 1000 V DC DC-20 750 V DC |
| [Im] rated making and breaking capacity | Icm 220 kA at 500 V conforming to DIN (with fuse) Icn 100 kA at 500 V conforming to DIN (with fuse) Icm 176 kA at 415 V conforming to DIN (with fuse) Icm 176 kA at 690 V conforming to DIN (with fuse) Icm 28 kA at 690 V (without fuse) Icn 80 kA at 415 V conforming to DIN (with fuse) Icn 80 kA at 690 V conforming to DIN (with fuse) Icm 37.5 kA at 500 V (without fuse) Icm 40.5 kA at 415 V (without fuse) |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Contact position indicator | Yes |
| Contact operation | Double-break |

It is a Compact NSXm molded case circuit breaker, 125A, 36kA at 415VAC, for all LV standard applications. It offers new features like Everlink technology, DIN rail and plate mounting capability. It embeds new spring type auxiliaries externally visible. Compact NSXm is one of the smallest MCCB on the market, 81mm (W) x 137mm (H) x 80mm (D). This is a 3 poles version with an embedded thermal-magnetic trip unit. It ensures compliance with international standards (IEC 60947/CCC/EAC) and marine specifications.
Main
| Characteristic | Value(s) |
|---|---|
| Range | ComPact |
| product name | ComPact NSXm |
| Range of product | ComPact NSXm |
| Device short name | NSXm 125F |
| Product or component type | Circuit breaker |
| Device application | Distribution Protection |
| Number of poles | 3P |
| Protected poles description | 3D |
| [In] rated current | 125 A at 40 °C |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz |
| Network type | AC |
| Network frequency | 50/60 Hz |
| Suitability for isolation | Yes conforming to EN/IEC 60947-2 |
| Utilisation category | Category A |
| [Icu] rated ultimate short-circuit breaking capacity | 85 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 35 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 |
| Performance level | F 36 kA 415 V AC |
| Trip unit name | TM-D |
| Trip unit technology | Thermal-magnetic |
| Trip unit protection functions | LI |
| control type | Toggle |
| Circuit breaker mounting mode | By screws Clip-on |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ics] rated service short-circuit breaking capacity | 85 kA at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 36 kA at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 30 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| Mechanical durability | 20000 cycles |
| Electrical durability | 10000 cycles at 440 V In 20000 cycles at 440 V In/2 5000 cycles at 690 V In 10000 cycles at 690 V In/2 |
| Mounting support | Plate DIN rail |
| Connection terminals | 1 Everlink lug wire size 2.5â¦70 mm², flexible copper 1 Everlink lug wire size 2.5â¦95 mm², rigid or stranded copper |
| Connection pitch | 35 mm with spreaders 27 mm without spreaders |
| 9 mm pitches | 9 module |
| Protection type | L : for overload protection (thermal) I : for short-circuit protection (magnetic) |
| Trip unit rating | 125 A at 40 °C |
| Long-time pick-up adjustment type Ir (thermal protection) | Adjustable |
| [Ir] long-time protection pick-up adjustment range | 0.7...1 x In |
| Long-time protection delay adjustment type tr | Fixed |
| [Im] magnetic protection pick-up range | 1250 A |
| Earth-leakage protection | Without |
| Number of slots for electrical auxiliaries | 1 slot(s) for auxiliary switch OF 1 slot(s) for alarm switch SD 1 slot(s) for voltage release MN or MX |
| Width (W) | 81 mm |
| Height (H) | 137 mm |
| Depth (D) | 80 mm |
| Product weight | 1.06 kg |
| Colour | Grey (RAL 7016) |






PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


TeSys F contactor, 3 poles (3NO), 630A/1000V AC-3, for motor applications up to 250kW@400V. It provides a low sealed consumption 120/127V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 1200 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys |
| Range of Product | TeSys F |
| Product or Component Type | Contactor |
| Device short name | LC1F |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-1 AC-4 AC-3 |
| Poles description | 3P |
| [Ue] rated operational voltage | <= 1000 V AC 50/60 Hz <= 460 V DC |
| [Uc] control circuit voltage | 120 V AC 40...400 Hz |
| [Ie] rated operational current | 1000 A (at <104 °F (40 °C)) at <= 440 V AC AC-1 630 A (at <131 °F (55 °C)) at <= 440 V AC AC-3 |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 1000 A (at 104 °F (40 °C)) 1250 A |
| Rated breaking capacity | 5040 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 5050 A 104 °F (40 °C) - 10 s 4400 A 104 °F (40 °C) - 30 s 3400 A 104 °F (40 °C) - 1 min 2200 A 104 °F (40 °C) - 3 min 1600 A 104 °F (40 °C) - 10 min |
| Associated fuse rating | 1000 A gG at <= 440 V 630 A aM at <= 440 V |
| Average impedance | 0.12 mOhm - Ith 1000 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V IEC 60947-4-1 1500 V VDE 0110 group C |
| Power dissipation per pole | 120 W AC-1 48 W AC-3 |
| Overvoltage category | III |
| power pole contact composition | 3 NO |
| Motor power kW | 335 kW at 380...400 V AC 50/60 Hz (AC-3) 375 kW at 415 V AC 50/60 Hz (AC-3) 400 kW at 440 V AC 50/60 Hz (AC-3) 400 kW at 500 V AC 50/60 Hz (AC-3) 450 kW at 660...690 V AC 50/60 Hz (AC-3) 450 kW at 1000 V AC 50/60 Hz (AC-3) 200 kW at 220...230 V AC 50/60 Hz (AC-3) 100 kW at 400 V AC 50/60 Hz (AC-4) |
| Control circuit voltage limits | Operational 0.85...1.1 Uc 40...400 Hz 131 °F (55 °C)) Drop-out 0.25...0.5 Uc 40...400 Hz 131 °F (55 °C)) |
| Mechanical durability | 5 Mcycles |
| Inrush power in VA | 1650 VA, 40...400 Hz 0.9 68 °F (20 °C)) |
| Hold-in power consumption in VA | 22 VA, 40...400 Hz 0.9 68 °F (20 °C)) |
| Maximum operating rate | 1200 cyc/h 131 °F (55 °C) |
| Operating time | 40...80 ms closing 100...200 ms opening |
| Connections - terminals | Control circuit screw clamp terminals 1 0.002â¦0.006 in² (1â¦4 mm²)flexible without cable end Control circuit screw clamp terminals 2 0.002â¦0.006 in² (1â¦4 mm²)flexible without cable end Control circuit screw clamp terminals 1 0.002â¦0.006 in² (1â¦4 mm²)flexible with cable end Control circuit screw clamp terminals 2 0.002â¦0.004 in² (1â¦2.5 mm²)flexible with cable end Control circuit screw clamp terminals 1 0.002â¦0.006 in² (1â¦4 mm²)solid without cable end Control circuit screw clamp terminals 2 0.002â¦0.006 in² (1â¦4 mm²)solid without cable end Power circuit bar 2 60 x 5 mm Power circuit bolted connection |
| Tightening torque | Control circuit 10.6 lbf.in (1.2 N.m) Power circuit 513.3 lbf.in (58 N.m) |
| Mounting Support | Plate |
| Heat dissipation | 20 W |
| Standards | JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1 EN 60947-4-1 EN 60947-1 |
| Product Certifications | LROS (Lloyds register of shipping) RINA CCC BV ABS UL DNV CB RMRoS UKCA |
| Compatibility code | LC1F |
| Control circuit type | AC 40...400 Hz |

trip unit Micrologic 6.2 E for Compact NSX 160/250 circuit breakers, electronic, rating 160A, 4 poles 4d


trip unit Micrologic 2.2 G for Compact NSX 160/250 circuit breakers, electronic, rating 160 A, 4 poles 4d

TeSys F contactor, 3 poles (3NO), 500A/1000V AC-3, for motor applications up to 250kW@400V. It provides a low sealed consumption 230V 40-400Hz AC coil, bolt terminals for bars or cables with lugs. For high operating rates until 2400 cycles/hour and environments until 55°C, it procures high reliability and durability. It makes installation and maintenance easy thanks to its drawer-mounted coil and a large choice of add-on blocks and accessories (to be ordered separately). Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys |
| Range of product | TeSys F |
| Product or component type | Contactor |
| Device short name | LC1F |
| Contactor application | Motor control Resistive load |
| Utilisation category | AC-1 AC-4 AC-3 |
| Poles description | 3P |
| [Ue] rated operational voltage | <= 690 V AC 50/60 Hz <= 460 V DC |
| [Uc] control circuit voltage | 230 V AC 40...400 Hz |
| [Ie] rated operational current | 700 A (at <40 °C) at <= 440 V AC AC-1 500 A (at <55 °C) at <= 440 V AC AC-3 |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Uimp] rated impulse withstand voltage | 8 kV |
| [Ith] conventional free air thermal current | 700 A (at 40 °C) |
| Rated breaking capacity | 4000 A conforming to IEC 60947-4-1 |
| [Icw] rated short-time withstand current | 4200 A 40 °C - 10 s 3200 A 40 °C - 30 s 2400 A 40 °C - 1 min 1500 A 40 °C - 3 min 1200 A 40 °C - 10 min |
| Associated fuse rating | 500 A aM at <= 440 V 800 A gG at <= 440 V |
| Average impedance | 0.18 mOhm - Ith 700 A 50 Hz |
| [Ui] rated insulation voltage | 1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C |
| Power dissipation per pole | 88 W AC-1 45 W AC-3 |
| Overvoltage category | III |
| power pole contact composition | 3 NO |
| Motor power kW | 250 kW at 380...400 V AC 50/60 Hz (AC-3) 280 kW at 415 V AC 50/60 Hz (AC-3) 295 kW at 440 V AC 50/60 Hz (AC-3) 355 kW at 500 V AC 50/60 Hz (AC-3) 335 kW at 660...690 V AC 50/60 Hz (AC-3) 335 kW at 1000 V AC 50/60 Hz (AC-3) 147 kW at 220...230 V AC 50/60 Hz (AC-3) 80 kW at 400 V AC 50/60 Hz (AC-4) |
| Control circuit voltage limits | Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C) Drop-out: 0.3...0.5 Uc 40...400 Hz (at 55 °C) |
| Mechanical durability | 10 Mcycles |
| Inrush power in VA | 1100 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Hold-in power consumption in VA | 18 VA, 40...400 Hz cos phi 0.9 (at 20 °C) |
| Maximum operating rate | 2400 cyc/h 55 °C |
| Operating time | 40...65 ms closing 100...170 ms opening |
| Connections - terminals | Control circuit: screw clamp terminals 1 cable(s) 1â¦4 mm²flexible without cable end Control circuit: screw clamp terminals 2 cable(s) 1â¦4 mm²flexible without cable end Control circuit: screw clamp terminals 1 cable(s) 1â¦4 mm²flexible with cable end Control circuit: screw clamp terminals 2 cable(s) 1â¦2.5 mm²flexible with cable end Control circuit: screw clamp terminals 1 cable(s) 1â¦4 mm²solid without cable end Control circuit: screw clamp terminals 2 cable(s) 1â¦4 mm²solid without cable end Power circuit: bar 2 cable(s) - busbar cross section: 40 x 5 mm Power circuit: lugs-ring terminals 2 cable(s) 240 mm² Power circuit: bolted connection |
| Tightening torque | Control circuit: 1.2 N.m Power circuit: 35 N.m |
| Mounting support | Plate |
| Heat dissipation | 18 W |
| motor power range | 250â¦500 kW at 380â¦440 V 3 phases 110â¦220 kW at 380â¦440 V 3 phases 110â¦220 kW at 200â¦240 V 3 phases 250â¦500 kW at 480â¦500 V 3 phases |
| Motor starter type | Direct on-line contactor |
| Contactor coil voltage | 230 V AC standard |
| Standards | IEC 60947-4-1 JIS C8201-4-1 EN 60947-1 IEC 60947-1 EN 60947-4-1 |
| Product certifications | DNV RINA RMRoS ABS UL CSA BV CB LROS (Lloyds register of shipping) UKCA |
| Compatibility code | LC1F |
| Control circuit type | AC at 40...400 Hz |