


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
XM-P2000 *1 |
|||
Type |
Probe |
|||
Marker |
No. of markers |
12 |
||
Housing material |
Marker body |
Quartz glass |
||
Probe housing |
PBT plastic |
|||
Light source |
Near-infrared LED (870 nm) |
|||
Applicable stylus |
M5 (Commercially available styluses can be used) |
|||
Camera |
Compact CMOS image sensor |
|||
Status LED |
Green: Measurement possible |
|||
Weight |
Approx. 500 g (including cable) |
|||
*1 Included with XM-2000, XM-T2000, XM-2200, and XM-T2200 models. | ||||

Specifications
Model |
VHX-S660E |
|||
XYθ stage |
XY stage: Motorized/Manual |
Motorized |
||
XY-stage movement range |
±50 mm ±1.97" |
|||
XYθ stage size |
Top surface: 233 × 185 mm 9.17" × 7.28" (Center disc: ø168 ø6.61") |
|||
Transmitted lighting |
Provided |
|||
Z stage |
Z stage: Motorized/Manual |
Motorized |
||
Z-motorized stage motor |
5-phase stepping motor |
|||
Z-motorized stage travel speed |
17 mm 0.67"/sec (max) |
|||
Z-stage movement range |
49 mm 1.93" |
|||
Load capacity |
5 kg |
|||
XYθ stage |
XY-motorized stage motor |
2-phase stepping motor |
||
XY-motorized stage resolution |
1 µm (typ.) |
|||
XY-motorized stage movement speed |
20 mm 0.79"/sec (max.) |
|||
Z stage |
Z-motorized stage resolution |
0.1 µm (typ.) |
||
Power supply |
Power voltage |
100 to 240 VAC, 50/60 Hz |
||
Power consumption |
60 VA |
|||
Environmental resistance |
Ambient temperature |
+5 to +40 °C 41 to 104 °F |
||
Relative humidity |
35 to 80 % RH (No condensation) |
|||
Weight |
Approx. 20 kg |
|||

Specifications
Model |
OP-25431 |
|||
Type |
Fittings |
|||
Overview |
Mounting bracket for FSーT1/M1 and PS-T1. |
|||
Applicable product |
FSーT1/M1/V11/V21, PS-T1, AP-V41, LV-11S, ES-M1/M2 |
|||
Material |
Polyacetal |
|||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
TM-X5120 |
|||
Transmitter/receiver distance |
436.7 mm 17.19" |
|||
Measuring range |
Field of view |
High-accuracy measurement area |
ø60 mm ø2.36" |
|
Measurement area |
ø124 mm ø4.88" |
|||
Depth of field |
High-accuracy measurement area |
20 mm 0.79" |
||
Measurement area |
40 mm 1.57" |
|||
Exposure time |
25/50/100 μs (Adjustable 3-stage) |
|||
Imaging time (Trigger interval) |
Approx. 24 ms (at “Full” vertical/horizontal measurement range sizes) |
|||
Light source |
InGaN green LED |
|||
Measurement position accuracy |
High-accuracy measurement area |
±2.5 μm ±0.000098" *1 |
||
Measurement area |
±3.5 μm 0.000138" *1 |
|||
Repeatability |
±0.2 μm ±0.000008" *2 |
|||
Pixel resolution |
Approx. 66 μm 0.002598" |
|||
Environmental resistance |
Enclosure rating |
IP64 *3 |
||
Ambient temperature |
0 to +45°C 32 to 113°F |
|||
Relative humidity |
85% RH or less (No condensation) |
|||
Material |
Aluminum/PBT |
|||
Weight |
Transmitter: Approx. 5900 g 13.01 lb |
|||
*1 Error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
FU-95Z |
|||
Type |
Liquid-level detection fiber unit |
|||
Detecting method |
Pipe mounting type |
|||
Mounting transparent tube diameter |
ø4 to 26 mmø0.157" to 1.024" |
|||
No. of beam axes |
1 mm0.039" |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R2 mm0.079" Tough-Flex |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Accessories |
Binding band × 2, nonslip rubber × 2, spacer × 2, screw × 2, nut × 2 |
|||
Weight |
Approx. 7 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
FS-N11N |
|||
Type |
Standard 1 output |
|||
Output |
NPN |
|||
Main unit/expansion unit |
Main unit |
|||
Control output |
1 |
|||
Monitor output (1-5 V) |
- |
|||
External input | ||||
Light source LED |
Red, 4-element LED |
|||
APC |
ON/OFF switchable (Factory setting: OFF) |
|||
Response time |
50 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER) /4 ms (ULTRA) /16 ms (MEGA) |
|||
Number of interference prevention units |
0 for HIGH SPEED; 4 for FINE; 8 for TURBO/SUPER/ULTRA/MEGA |
|||
Unit expansion |
Up to 16 units can be connected total (two output type is treated as two units) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current Consumption |
Normal: 900 mW or less (36 mA max. at 24 V, 48 mA max. at 12 V)*1 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux or less, Sunlight: 30,000 lux or less |
||
Ambient temperature |
-20 to +55 °C -4 to +131 °F (No freezing)*2 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Both main unit and expansion unit housing material: Polycarbonate |
|||
Weight |
Approx. 75 g |
|||
*1 Increases 100 mW (4.0 mA) for High Speed mode | ||||


Specifications
Model |
FU-56TZ*1 |
|||
Type |
fibre unit |
|||
Shape |
Thrubeam |
|||
Minimum bend radius |
R2 mm |
|||
Minimum detectable object |
Opaque material with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-40 to +50 °C -40 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 20 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
KV-SSC02 |
|||
Type |
High-speed counter unit |
|||
Input frequency |
Single phase 4 MHz (16 MHz during 2-phase, 4-multiplication) |
|||
Counting range |
32 bits |
|||
Number of channels |
2 ch |
|||
Mode |
Input selection |
External terminal (CH0, CH1), internal clock (0.05 μs, 1 μs, 10 μs, 100 μs), other CH coincidence output, communication: EnDat2.2/22, BiSS (C-mode), YASKAWA serial |
||
Input mode |
1-pulse with/without direction, 2-pulse addition/subtraction operation, 2-phase 1-multiplication/2-multiplication/4-multiplication |
|||
Counting operation mode |
• Up-down counting mode • Enable counting mode • Preset counting mode • Set timer counting mode • Enable accumulative counting mode |
|||
Counting mode |
Linear, ring |
|||
Frequency, revolution counter operation mode |
• Frequency counting mode • Revolution counter B mode (1-revolution time measurement) • Revolution counter A mode (pulse interval measurement) |
|||
Input |
Count input |
A-phase/B-phase/Z-phase (preset), 3 points for each channel, 6 points in total |
||
Control input |
Enable (also used for input capture) input, 1 point for each channel, 2 points in total |
|||
Output |
Comparator coincidence output |
2 points for each channel, 4 points in total, photocoupler insulation |
||
Input capture function |
By external input (max. 4 points) |
|||
Buffering function |
Buffering period: 1 μs or more |
|||
Input filter function |
Input time constant switching (6 types of counting/9 types of control) |
|||
Preset function |
Possible to select from preset (Z-phase) input and internal relay-based rising edge/falling edge/level (only when an external input is used) |
|||
Serial encoder communication function |
Supported encoder |
Absolute encoders that support EnDat2.2/22, BiSS (C-mode), and YASKAWA serial |
||
Communication cycle |
EnDat2.2/22: 50 μs, BiSS (C-mode): 50 μs, YASKAWA serial: 62.5 μs |
|||
Input |
Equivalent to a differential line receiver that meets the EIA RS485 standard |
|||
Output |
Equivalent to a differential line driver that meets the EIA RS485 standard |
|||
Encoder 5 V power |
5 VDC (±5%), 300 mA or less |
|||
Others |
Unit interrupt, inter-unit synchronization |
|||
Internal current consumption |
190 mA or less |
|||
Weight |
Approx. 130 g |
|||

Specifications
Model |
CA-DBB8 |
|||
Type |
Bar Light |
|||
LED color |
Blue |
|||
Diffusion plate |
OP-87042 |
|||
Polarizing plate |
OP-87043 |
|||
Power consumption |
4.8 W |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 60 g |
|||

Specifications
Model |
SV2-D20AG |
|||
Type |
Motor power cable, Hi-flex robotic cable with electromagnetic brake |
|||
Length |
20 m 65.6' |
|||
Note |
for 50 W / 100 W motor |
|||

Specifications
Model |
GS-71P10 |
|||
Lock type |
Power-to-lock type |
|||
Type |
Standard type |
|||
Response time |
Lock |
Lock→Unlock |
320 ms*1*2 |
|
Unlock→Lock |
220 ms*1*2*3 |
|||
Lock |
Locking force (Fzh) |
Min. 2,000 N |
||
Alignment tolerance of lock |
±2 mm ±0.08" |
|||
Mechanical life-span |
1 million cycles or more (with door operation speed of 1 m/s) |
|||
Acceptable operation frequency |
1 Hz*4 |
|||
Door radius |
Min. 250 mm 9.84" |
|||
Auxiliary release |
Front, back *5 |
|||
Cascading |
Max. 25 units |
|||
Control output (OSSD output) |
Output |
Transistor outputs × 2 |
||
Max. load current |
Max. 150 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
OFF state voltage |
Max 2.0 V (with a cable length of 5 m 16.40') |
|||
Leakage current |
Max. 0.5 mA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
AUX (Non-safety related output) |
Output |
Transistor output |
||
Number of outputs |
1 |
|||
Max. load current |
50 mA |
|||
Residual voltage (during ON) |
Max 2.5 V (with a cable length of 5 m 16.40') |
|||
External input (Short-circuit current) |
Safety input |
Approx.1.5 mA × 2 |
||
Reset/EDM input |
- |
|||
Lock control input |
Approx. 2.5 mA × 1 |
|||
OSSD operation switching input |
- |
|||
Applicable Standards (Safety) |
EN 61508, IEC 61508(SIL2/SIL3) |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Power supply |
Power voltage |
24 V DC ±20 % (Ripple P-P 10 % or less, Class2) |
||
Power consumption |
3.4 W*6 |
|||
Environmental resistance |
Enclosure rating |
IP65/67(IEC60529), IP69K(ISO 20653) (TÜV SÜD certified), |
||
Operating ambient temperature |
-20°C to +55C° -4°F to 131°F (No freezing) |
|||
Operating relative humidity |
5% to 95%RH |
|||
Storage temperature |
-25°C to +70°C -13°F to 158°F (No freezing)*7 |
|||
Storage relative humidity |
5% to 95%RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 2.0 mm 0.08", 5 minutes in each of the X, Y, and Z directions (IEC 60947-5-3) |
|||
Shock resistance |
30 G in X, Y, Z directions 6 times each axis (IEC 60947-5-3) |
|||
Material |
Sensor main unit |
Case |
SUS304, PPS, PBT, PAR, PA66, NBR |
|
Lock |
Aluminum alloy, Zinc die cast (Nickel chrome plating) |
|||
Cable |
PVC |
|||
Actuator |
Case |
PPS, PBT, NBR |
||
Lock |
Aluminum alloy, SUS303 |
|||
Weight |
Approx. 770 g |
|||
*1 Risk time according to IEC60947-5-3 is 150 ms + 2 ms × (number of units cascaded -1). | ||||

Specifications
Model |
OP-88100 |
|||
Type |
Vertical Mounting Bracket |
|||
Applicable product |
AI-H010, AI-H020 |
|||
Note |
Short range, for Separate amplifier models |
|||

Specifications
Model |
KV-NC32ET |
|||
Expansion output unit |
External connectionmethod |
MOSFET (With overcurrent protection function)*1*2 |
||
External connection method |
Connector |
|||
Rated load |
30 VDC. 0.2 A *3 |
|||
Leakage current (when output is OFF) |
100 μA or less |
|||
Residual voltage (at ON) |
0.6 VDC or less |
|||
ON resistance |
− |
|||
Common method |
32 points/1 common (2 terminals)*4*5 |
|||
Response time |
OFF to ON |
100 μs or less (with a load of 1 mA or more) |
||
ON to OFF |
200 μs or less (with a load of 1 mA or more) |
|||
Relay life |
− |
|||
Relay replacement | ||||
Internal current consumption |
50 mA or less |
|||
Weight |
Approx. 110 g |
|||
*1 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic recovery are repeated for all outputs within the shared common (The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 015 or 100 to 115 for the KV-NC32ET(P).) , until the cause of the problem is removed. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
PX-H61 |
|||
Type |
M12 Reflective Standard |
|||
Light source LED |
Red 4-element LED |
|||
Detecting distance |
TURBO |
400 mm 15.7" |
||
SUPER |
600 mm 23.6" |
|||
ULTRA |
1200 mm 47.2" |
|||
MEGA |
2000 mm 78.7" |
|||
Detectable object |
― |
|||
Spot diameter |
Approx. 15 x 15 mm 0.59" |
|||
Environmental resistance |
Enclosure rating |
IEC: IP68/JEM: IP68g/NEMA: 4X, 6P, 13/DIN: IP69K |
||
Ambient light |
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Case material |
Housing :SUS303 (Plastic parts:PMP, POM) Lens :BK7 |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 80 g*1 (Including cable) |
|||
*1 The PX-H71G, H72G and H61G have SUS304 spiral protective tube on the cables. | ||||
