ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
1 piece
85365080
Finland
Dimensions
226 mm
185 mm
107 mm
3.2 kg
7.1 lb
3.2 kg
7.1 lb
Container Information
box 1 piece
250 mm
9.8 in
250 mm
9.8 in
290 mm
11.4 in
290 mm
11.4 in
170 mm
6.7 in
170 mm
6.7 in
3.5 kg
7.7 lb
3.5 kg
7.7 lb
6417019337371
Technical
Θ = 40 °C 400 A
Fully Enclosed 400 A
Front IP00
Standard
Handle and shaft not included
16000
Base mounting
3P
Side operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 10 W
12 kV
acc. to IEC/EN 60664-1 1000 V
(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
(380 ... 415 V) 400 A
(500 V) 400 A
(690 V) 400 A
(220 ... 240 V) 132 kW
(400 ... 415 V) 230 kW
(500 V) 280 kW
(690 V) 400 kW
(220 ... 240 V) 132 kW
(400 ... 415 V) 230 kW
(500 V) 280 kW
(690 V) 400 kW
Main Circuit 1000 V
(690 V) 65 kA
for 1 s 15 kA
No
IEC 60947-3
Mechanism at the End of the Switch
30 (Right Side)
Mechanism at the End of the Switch
30 (Right Side)
Lug terminals
acc. IEC 60947-1 30 … 44 N·m
Technical UL/CSA
acc. IEC 60947-1 30 … 44 N·m
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
1 piece
85389099
Finland
Dimensions
80 mm
158.5 mm
167 mm
0.8 kg
Container Information
1 piece
150 mm
200 mm
100 mm
0.86 kg
6417019338804
Technical
L/4
Certificates and Declarations
External Classifications and Standards
N/A
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
39122221
5219 >> Switch part or accessory
V11.1 : 27371392
Product Not in WEEE Scope
3661826

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
IP65
Ordering
1 piece
85389099
Finland
Dimensions
400 mm
15.75 in
400 mm
15.75 in
69 mm
2.72 in
69 mm
2.72 in
71 mm
2.8 in
71 mm
2.8 in
0.6 kg
1.32 lb
0.6 kg
1.32 lb
Container Information
bag 1 piece
69 mm
400 mm
71 mm
0.6 kg
6417019395371
Technical
Black
IP65
Black
400 mm
Pistol
J12E011
Certificates and Declarations
External Classifications and Standards
N/A
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
39122221
3038 >> Handles or knobs
V11.1 : 27370414
Product Not in WEEE Scope
3650356

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
IP65
Ordering
1 piece
85389099
Finland
Dimensions
178 mm
45 mm
66 mm
0.175 kg
Container Information
bag 1 piece
70 mm
180 mm
50 mm
0.18 kg
6417019352169
Technical
Black
IP65
Black
145 mm
Pistol
J12E-RUH
Certificates and Declarations
External Classifications and Standards
N/A
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
V11.1 : 27370414
Product Not in WEEE Scope

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
1 piece
85389099
Finland
Dimensions
80 mm
372 mm
131.5 mm
4.9 kg
Container Information
box 1 piece
153 mm
335 mm
260 mm
5.5 kg
6417019353623
Certificates and Declarations
External Classifications and Standards
N/A
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
V11.1 : 27371392
Product Not in WEEE Scope

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
IP65
Ordering
1 piece
85389099
Germany
Dimensions
66 mm
66 mm
59 mm
0.055 kg
Container Information
bag 1 piece
66 mm
59 mm
66 mm
0.06 kg
4034656511531
Technical
Red-Yellow
IP65
Red / Yellow
Selector
PRY
Certificates and Declarations
External Classifications and Standards
N/A
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
39122221
5219 >> Switch part or accessory
V11.1 : 27370414
5. Small Equipment (No External Dimension More Than 50 cm)
3602369

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
10 piece
85389099
Finland
Dimensions
6 mm
6 mm
85 mm
0.02 kg
Container Information
bag 1 piece
6 mm
85 mm
6 mm
0.23 kg
6417019365718
Technical
6 mm
85 mm
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope
3661942
4363598
3171328

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
10 piece
85389099
Finland
Dimensions
6 mm
6 mm
115 mm
0.03 kg
Container Information
bag 1 piece
6 mm
115 mm
6 mm
0.031 kg
6417019365732
Technical
6 mm
115 mm
lov
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
9c601301-d4d5-4298-a3e1-eed1ad16d25e Finland
cb1884b4-ce2c-4acb-a208-9e01a025e333 Germany
2b0f63ce-34cd-4ae8-b123-00a45210a4a8 Poland
7cfc32a8-1672-40ec-96c1-72498d971e99 Italy
0b4d9393-5f50-489e-841c-1bc56c899adc Germany
5cc4fd5c-960e-44f1-bf0a-4ccb6a384eda Germany
be020cbf-0bd1-484a-bc74-ed692c9d2613 Germany
56e3748e-4cf7-4079-99cb-7d730f0665e3 Poland
8ea8e3cd-22c6-460f-a507-ef8308af2a49 Belgium
a036ed0f-f208-4d9f-b0cb-18bccb791ff5 Netherlands
a74fad45-059d-49c0-9dba-e1444e0b405e Norway
b9536cef-c094-40f9-90be-9214ec15c875 Poland
8d99360a-33c4-4ce4-9631-b9ad5c00ba1d Sweden
2021d629-cf9f-4986-81aa-14cc5b3933bc Bulgaria
ebbfc13d-c92a-4be2-ba79-40ccdb49025f Greece
ea070e55-028a-445a-87dd-2ea4a78dba75 Estonia
d16fdec6-c352-498b-a186-6e193edf8644 Hungary
78d87c18-23b4-4996-9f5a-1322f290f5af Belgium
0ab29dc8-7356-48e8-8ab6-196bb6bb26c3 Spain
6126aa33-ce3a-4e52-b9d3-483dd91affe1 Hungary
e29af053-9541-4ad6-aead-3ef9b3f84605 Portugal
ebda8420-4926-4ad6-8f61-0078550cd989 France
06cbae5a-248f-4add-b3dc-84780c187a53 Sweden
a39c6cd0-f294-4b71-8234-b46c84840fb8 Czech Republic
a5c3b3ab-8cd5-43dd-a1fa-0b304e3af8b0 Croatia
a76340c0-9cea-4bab-bbbf-d4f9dfb4ae83 France
6a82df3f-07cc-481e-8deb-1633604ca18c Denmark
a456e745-a090-4ee1-acdc-580bf02116c7 Germany
cb1884b4-ce2c-4acb-a208-9e01a025e333 Germany
2b0f63ce-34cd-4ae8-b123-00a45210a4a8 Poland
7cfc32a8-1672-40ec-96c1-72498d971e99 Italy
0b4d9393-5f50-489e-841c-1bc56c899adc Germany
5cc4fd5c-960e-44f1-bf0a-4ccb6a384eda Germany
be020cbf-0bd1-484a-bc74-ed692c9d2613 Germany
56e3748e-4cf7-4079-99cb-7d730f0665e3 Poland
8ea8e3cd-22c6-460f-a507-ef8308af2a49 Belgium
a036ed0f-f208-4d9f-b0cb-18bccb791ff5 Netherlands
a74fad45-059d-49c0-9dba-e1444e0b405e Norway
Popular Downloads
Ordering
10 piece
85389099
Estonia
Dimensions
6 mm
6 mm
120 mm
0.03 kg
Container Information
bag 1 piece
6 mm
120 mm
6 mm
0.32 kg
6417019365787
Technical
6 mm
120 mm
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope
3661945
4363599
3171334

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
10 piece
85389099
Estonia
Dimensions
6 mm
6 mm
130 mm
0.03 kg
Container Information
bag 1 piece
6 mm
130 mm
6 mm
0.35 kg
6417019365770
Technical
6 mm
130 mm
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope
3661944
4363600
3171335

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
10 piece
85389099
Estonia
Dimensions
6 mm
6 mm
160 mm
0.05 kg
Container Information
bag 1 piece
6 mm
160 mm
6 mm
0.53 kg
6417019365800
Technical
6 mm
160 mm
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope
3661946
4363604
3171336

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
10 piece
85389099
Finland
Dimensions
6 mm
6 mm
180 mm
0.05 kg
Container Information
bag 1 piece
6 mm
180 mm
6 mm
0.55 kg
6417019365831
Technical
6 mm
180 mm
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope
3661947
4363601
3171338

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
10 piece
85389099
Finland
Dimensions
6 mm
6 mm
250 mm
0.06 kg
Container Information
bag 1 piece
6 mm
250 mm
6 mm
0.74 kg
6417019365848
Technical
6 mm
250 mm
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope
3661948
4363603
3171339

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Ordering
10 piece
85389099
Finland
Dimensions
6 mm
6 mm
330 mm
0.08 kg
Container Information
bag 1 piece
6 mm
330 mm
6 mm
0.90 kg
6417019365855
Technical
6 mm
330 mm
Certificates and Declarations
External Classifications and Standards
N/A
EC000916 - Switch operating shaft
EC000916 - Switch operating shaft
39122221
5219 >> Switch part or accessory
V11.1 : 27370413
Product Not in WEEE Scope
3661949
4363602
3171342

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
IP54
Ordering
10 piece
85389099
Lithuania
Dimensions
48 mm
48 mm
40 mm
0.035 kg
Container Information
1 piece
48 mm
48 mm
41 mm
0.04 kg
6417019409740
Technical
Black
IP54
Black
Selector
Certificates and Declarations
External Classifications and Standards
N/A
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
31162801
3038 >> Handles or knobs
V11.1 : 27370414
Product Not in WEEE Scope
3661900
4363577
3171312

Popular Downloads
Environmental
acc. to IEC 60529 IP65
3
Ordering
1 piece
85363030
Mexico
Dimensions
146 mm
5.75 in
146 mm
5.75 in
200 mm
7.87 in
200 mm
7.87 in
103.5 mm
4.07 in
103.5 mm
4.07 in
1.18 kg
2.6 lb
1.18 kg
2.6 lb
Container Information
1 piece
150 mm
200 mm
146 mm
1.2 kg
2.65 lb
1.2 kg
2.65 lb
6417019383415
Technical
Up/Down
2x(ø1 / 25.4+ø0.75 / 19.1)
Screw Clamp 1.5…35 mm²
Screw Clamp / PE Terminal 1pcs, 0.5…16 mm²
Screw Clamp 1.5…35 mm²
Screw Clamp / PE Terminal 1pcs, 0.5…16 mm²
60 A
acc. to IEC 60529 IP65
Plastic
NEMA Type 4/4X Watertight
Black
Pistol handle
20000
1 NO, 0 NC
3P
3
Top In - Bottom Out
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 63 A
(690 V) 63 A
(380 ... 415 V) 63 A
(690 V) 63 A
(690 V) 63 A
(690 V) 380415V20 A
(690 V) 63 A
(690 V) 380415V20 A
(690 V AC) 1.4 kA
for 1 s 1 kA
IEC 60947-1, -3 / UL 508
Screw Terminals
acc. IEC 60947-1 2 N·m
Technical UL/CSA
600 V
60 A
(220 ... 240 V AC) Three Phase 15 Hp
(480 V AC) 30 Hp
(600 V AC) 30 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(480 V AC) 30 Hp
(600 V AC) 30 Hp
acc. IEC 60947-1 2 N·m
Main Circuit 18 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5293 >> Switch disconnector
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
IP66
Ordering
1 piece
85389099
China
Dimensions
400 mm
45 mm
66 mm
1.9 kg
Container Information
box 1 piece
95 mm
335 mm
67 mm
1.9 kg
6417019483610
Technical
Metal
IP66
Stainless Steel
400 mm
Pistol
L12
Certificates and Declarations
External Classifications and Standards
N/A
EC000229 - Handle for power circuit breaker
EC000229 - Handle for power circuit breaker
31162801
3038 >> Handles or knobs
V11.1 : 27370414
Product Not in WEEE Scope
3601524

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
10 piece
85365080
Finland
Dimensions
35 mm
68 mm
56 mm
0.09 kg
Container Information
box 1 piece
67 mm
79 mm
46 mm
0.1 kg
6417019389554
Technical
Cu 0.75 ... 10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Θ = 40 °C 25 A
Fully Enclosed 25 A
Front IP20
Standard
Knob
Handle and shaft not included
Knob
Handle and shaft not included
20000
Base mounting
3P
Front operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 0.3 W
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
8 kV
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Main Circuit 750 V
(690 V) 0.71 kA
for 1 s 0.5 kA
Main Circuit Pozidriv 2
No
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 0.8 N·m
Main Circuit 9-10 mm
Technical UL/CSA
600 V
20 A
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 9-10 mm
Main Circuit Pozidriv 2
acc. IEC 60947-1 0.8 N·m
7 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5290 >> Disconnect switch
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601419
4363520
3170937

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
10 piece
85365080
Finland
Dimensions
48 mm
68 mm
56 mm
0.125 kg
Container Information
box 1 piece
67 mm
79 mm
61 mm
0.14 kg
6417019389738
Technical
Cu 0.75 ... 10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Θ = 40 °C 25 A
Fully Enclosed 25 A
Front IP20
Standard
Right Side
Switched - Simultaneous Function
Knob
Handle and shaft not included
Knob
Handle and shaft not included
20000
Base mounting
4P
Front operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 0.3 W
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
8 kV
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Main Circuit 750 V
(690 V) 0.71 kA
for 1 s 0.5 kA
Main Circuit Pozidriv 2
No
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 0.8 N·m
Main Circuit 9-10 mm
Technical UL/CSA
600 V
20 A
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 9-10 mm
Main Circuit Pozidriv 2
acc. IEC 60947-1 0.8 N·m
7 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5293 >> Switch disconnector
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601422
4363521

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Front IP20
3
Ordering
1 piece
85365080
Finland
Dimensions
96 mm
3.78 in
96 mm
3.78 in
68 mm
2.68 in
68 mm
2.68 in
68 mm
2.68 in
68 mm
2.68 in
0.31 kg
0.68 lb
0.31 kg
0.68 lb
Container Information
box 1 box
80 mm
3.15 in
80 mm
3.15 in
108 mm
4.25 in
108 mm
4.25 in
79 mm
3.11 in
79 mm
3.11 in
0.31 kg
0.68 lb
0.31 kg
0.68 lb
6417019389752
Technical
0.75 ... 10 mm²
Θ = 40 °C 25 A
Fully Enclosed 25 A
Front IP20
Standard
Right Side
Switched - Simultaneous Function
Black
Handle and shaft not included
Base mounting
4P
Front operated
3
Top In - Bottom Out, Bottom In - Top Out
at Rated Operating Conditions per Pole 0.3 W
8 kV
750 V
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(380 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(380 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Main Circuit 750 V
for 1 s 0.5 kiloampere rms
UL 98 / IEC60947-3
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 0.8 N·m
Open
Technical UL/CSA
16 A
(acc. to UL 200 V) 3 Hp
(acc. to UL 208 V) 3 Hp
(acc. to UL 240 V) 5 Hp
(acc. to UL 480 V) 10 Hp
(acc. to UL 600 V) 10 Hp
(acc. to UL 200 V) 3 Hp
(acc. to UL 208 V) 3 Hp
(acc. to UL 240 V) 5 Hp
(acc. to UL 480 V) 10 Hp
(acc. to UL 600 V) 10 Hp
acc. IEC 60947-1 0.8 N·m
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5290 >> Disconnect switch
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601423
4363549

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
1 piece
85365080
Finland
Dimensions
70 mm
68 mm
68 mm
0.21 kg
Container Information
box 1 piece
80 mm
112 mm
80 mm
0.25 kg
6417019389783
Technical
Cu 0.75 ... 10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Θ = 40 °C 25 A
Fully Enclosed 25 A
Front IP20
Standard
Knob
Handle and shaft not included
Knob
Handle and shaft not included
20000
Base mounting
6P
Front operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 0.3 W
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
8 kV
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Main Circuit 750 V
(690 V) 0.71 kA
for 1 s 0.5 kA
Main Circuit Pozidriv 2
No
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 0.8 N·m
Main Circuit 9-10 mm
Technical UL/CSA
600 V
20 A
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 9-10 mm
Main Circuit Pozidriv 2
acc. IEC 60947-1 0.8 N·m
7 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5290 >> Disconnect switch
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601424
4363562
3172087

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
1 piece
85365080
Finland
Dimensions
96 mm
68 mm
68 mm
0.27 kg
Container Information
box 1 piece
80 mm
112 mm
80 mm
0.31 kg
6417019389806
Technical
Cu 0.75 ... 10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Θ = 40 °C 25 A
Fully Enclosed 25 A
Front IP20
Standard
Left and Right Side
Switched - Simultaneous Function
Knob
Handle and shaft not included
Knob
Handle and shaft not included
20000
Base mounting
8P
Front operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 0.3 W
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
8 kV
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(750 V) 16 A
(750 V) 550V'16 A
(800 V) 16 A
(750 V) 16 A
(750 V) 550V'16 A
(800 V) 16 A
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Main Circuit 750 V
(690 V) 0.71 kA
for 1 s 0.5 kA
Main Circuit Pozidriv 2
No
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 0.8 N·m
Main Circuit 9-10 mm
Technical UL/CSA
600 V
20 A
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 9-10 mm
Main Circuit Pozidriv 2
acc. IEC 60947-1 0.8 N·m
7 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5290 >> Disconnect switch
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601425
4363569

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
10 piece
85365080
Finland
Dimensions
43 mm
54 mm
52 mm
0.1 kg
Container Information
box 1 piece
63 mm
65 mm
54 mm
0.11 kg
6417019389820
Technical
Cu 0.75 ... 10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Θ = 40 °C 25 A
Fully Enclosed 25 A
Front IP20
Standard
Handle and shaft not included
20000
Door mounting
3P
Front operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 0.3 W
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
8 kV
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 16 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(380 ... 415 V) 16 A
(500 V) 16 A
(690 V) 10 A
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
(220 ... 240 V) 3 kW
(400 ... 415 V) 7.5 kW
(500 V) 7.5 kW
(690 V) 7.5 kW
Main Circuit 750 V
(690 V) 0.71 kA
for 1 s 0.5 kA
Main Circuit Pozidriv 2
No
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 0.8 N·m
Main Circuit 9-10 mm
Technical UL/CSA
600 V
20 A
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(110 ... 120 V AC) Single Phase 1 Hp
(240 V AC) Single Phase 2 Hp
(440 ... 480 V AC) Single Phase 5 Hp
(550 ... 600 V AC) Single Phase 7.5 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
Main Circuit 9-10 mm
Main Circuit Pozidriv 2
acc. IEC 60947-1 0.8 N·m
7 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5290 >> Disconnect switch
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601426
4363534
3170944

ABB EcoSolutions
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Popular Downloads
Environmental
Ordering
10 piece
85365080
Finland
Dimensions
35 mm
68 mm
56 mm
0.09 kg
Container Information
box 1 piece
67 mm
79 mm
46 mm
0.1 kg
6417019390000
Technical
Cu 0.75 ... 10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Flexible with Ferrule 1x Cu 0.75…4 mm²
Solid 1x Cu 0.75…6 mm²
Flexible 1x Cu 0.75…10 mm²
Stranded 1x Cu 0.75…10 mm²
Θ = 40 °C 32 A
Fully Enclosed 32 A
Front IP20
Standard
Knob
Handle and shaft not included
Knob
Handle and shaft not included
20000
Base mounting
3P
Front operated
3
Top In - Bottom Out
Bottom In - Top Out
Top In - Bottom Out
Bottom In - Top Out
at Rated Operating Conditions per Pole 0.6 W
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
(40 A fuse, ≤415V) 50 kA
(25 A fuse, 690 V) 50 kA
8 kV
acc. to IEC/EN 60664-1 750 V
(380 ... 415 V) 25 A
(500 V) 25 A
(690 V) 25 A
(380 ... 415 V) 25 A
(500 V) 25 A
(690 V) 25 A
(380 ... 415 V) 25 A
(500 V) 25 A
(690 V) 25 A
(380 ... 415 V) 25 A
(500 V) 25 A
(690 V) 25 A
(380 ... 415 V) 20 A
(500 V) 20 A
(690 V) 11 A
(380 ... 415 V) 20 A
(500 V) 20 A
(690 V) 11 A
(220 ... 240 V) 4 kW
(400 ... 415 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
(220 ... 240 V) 4 kW
(400 ... 415 V) 9 kW
(500 V) 9 kW
(690 V) 9 kW
Main Circuit 750 V
(690 V) 0.71 kA
for 1 s 0.5 kA
Main Circuit Pozidriv 2
No
IEC 60947-3 / UL 508 / CSA C22.2 No. 14
Mechanism on Top of the Switch
Screw Terminals
acc. IEC 60947-1 0.8 N·m
Main Circuit 9-10 mm
Technical UL/CSA
600 V
30 A
(110 ... 120 V AC) Single Phase 1.5 Hp
(240 V AC) Single Phase 3 Hp
(440 ... 480 V AC) Single Phase 7.5 Hp
(550 ... 600 V AC) Single Phase 10 Hp
(220 ... 240 V AC) Three Phase 7,5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
(110 ... 120 V AC) Single Phase 1.5 Hp
(240 V AC) Single Phase 3 Hp
(440 ... 480 V AC) Single Phase 7.5 Hp
(550 ... 600 V AC) Single Phase 10 Hp
(220 ... 240 V AC) Three Phase 7,5 Hp
(440 ... 480 V AC) Three Phase 15 Hp
(550 ... 600 V AC) Three Phase 20 Hp
Main Circuit 9-10 mm
Main Circuit Pozidriv 2
acc. IEC 60947-1 0.8 N·m
7 in·lb
Certificates and Declarations
External Classifications and Standards
Q
EC000216 - Switch disconnector (low voltage)
EC000216 - Switch disconnector (AC)
39122233
5290 >> Disconnect switch
V11.1 : 27371403
5. Small Equipment (No External Dimension More Than 50 cm)
3601428
4363522
3170938