keyence

6950 products

Showing 6385 - 6408 of 6950 products

Showing 6385 - 6408 of 6950 products
View
keyence Stock Image
Keyence SV3-020L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-020L2

General specifications

Capacity

200 W

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 0.8 kg 28.22 oz

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/Single-phase 200 V/DC 270 V

Max. applicable motor capacity

200 W

Power supply capacity for 1 amplifier

Three-phase 200 V: 0.5 kVA
Single-phase 200 V: 0.6 kVA
DC 270 V: 0.5 kVA

Output current

Continuous

1.6 Arms

Max.

5.9 Arms

Main circuit power loss

Three-phase 200 V: 11.9 W
Single-phase 200 V: 12.1 W
DC 270 V: 9.8 W

Regenerative resistor power loss

Control circuit power loss

12 W

Total power loss

Three-phase 200 V: 23.9 W
Single-phase 200 V: 24.1 W
DC 270 V: 21.8 W

Rated input current

Main circuit

Three-phase 200 V: 1.3 Arms
Single-phase 200 V: 2.4 Arms
DC 270 V: 1.5 Arms

Control circuit

0.2 Arms

Rush current

Main circuit

29 A *3

Control circuit

34 A *3

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*4)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*5 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-040L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-040L2

General specifications

Capacity

400 W

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 1.1 kg 2.43 lb

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/Single-phase 200 V/DC 270 V

Max. applicable motor capacity

400 W

Power supply capacity for 1 amplifier

Three-phase 200 V: 1.0kVA
Single-phase 200 V: 1.2kVA
DC 270 V: 1.0kVA

Output current

Continuous

2.8 Arms

Max.

9.3 Arms

Main circuit power loss

Three-phase 200 V: 22.5 W
Single-phase 200 V: 23.7 W
DC 270 V: 17.5 W

Regenerative resistor power loss

Control circuit power loss

12 W

Total power loss

Three-phase 200 V: 34.5 W
Single-phase 200 V: 35.7 W
DC 270 V: 29.5 W

Rated input current

Main circuit

Three-phase 200 V: 2.5 Arms
Single-phase 200 V: 5.0 Arms
DC 270 V: 3 Arms

Control circuit

0.2 Arms

Rush current

Main circuit

29 A *3

Control circuit

34 A *3

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*4)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*5 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-075L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-075L2

General specifications

Capacity

750 W

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 1.6 kg 3.53 lb

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/Single-phase 200 V/DC 270 V

Max. applicable motor capacity

750 W

Power supply capacity for 1 amplifier

Three-phase 200 V: 1.6 kVA
Single-phase 200 V: 1.9 kVA
DC 270 V: 1.6 kVA

Output current

Continuous

5.5 Arms

Max.

16.9 Arms

Main circuit power loss

Three-phase 200 V: 38.9 W
Single-phase 200 V: 39.2 W
DC 270 V: 30.7 W

Regenerative resistor power loss

Three-phase 200 V: 15 W
Single-phase 200 V: 15 W
DC 270 V: ―

Control circuit power loss

14 W

Total power loss

Three-phase 200 V: 52.9 W
Single-phase 200 V: 53.2 W
DC 270 V: 44.7 W

Rated input current

Main circuit

Three-phase 200 V: 4.1 Arms
Single-phase 200 V: 8.7 Arms
DC 270 V: 4.9 Arms

Control circuit

0.2 Arms

Rush current

Main circuit

34 A *3

Control circuit

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*4)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*5 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-100L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-100L2

General specifications

Capacity

1.0 kW

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 1.6 kg 3.53 lb

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/DC 270 V

Max. applicable motor capacity

1.0 kW

Power supply capacity for 1 amplifier

2.3 kVA

Output current

Continuous

7.6 Arms

Max.

17 Arms

Main circuit power loss

Three-phase 200 V: 49.2 W
DC 270 V: 38.7 W

Regenerative resistor power loss

Three-phase 200 V: 15 W
DC 270 V: ―

Control circuit power loss

14 W

Total power loss

Three-phase 200 V: 63.2 W
DC 270 V: 52.7 W

Rated input current

Main circuit

Three-phase 200 V: 5.7 Arms
DC 270 V: 6.9 Arms

Control circuit

0.2 Arms

Rush current

Main circuit

34 A *3

Control circuit

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*4)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*5 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-150L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-150L2

General specifications

Capacity

1.5 kW

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 2.1 kg 4.63 lb

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/DC 270 V

Max. applicable motor capacity

1.5 kW

Power supply capacity for 1 amplifier

3.2 kVA

Output current

Continuous

11.6 Arms

Max.

28 Arms

Main circuit power loss

Three-phase 200 V: 72.6 W
DC 270 V: 55.8 W

Regenerative resistor power loss

Three-phase 200 V: 30 W
DC 270 V: ―

Control circuit power loss

15 W

Total power loss

Three-phase 200 V: 87.6 W
DC 270 V: 70.8 W

Rated input current

Main circuit

Three-phase 200 V: 7.3 Arms
DC 270 V: 11 Arms

Control circuit

0.2 Arms

Rush current

Main circuit

34 A *3

Control circuit

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*4)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*5 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-200L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-200L2

General specifications

Capacity

2.0 kW

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 2.8 kg 6.17 lb

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/DC 270 V

Max. applicable motor capacity

2.0 kW

Power supply capacity for 1 amplifier

4.0 kVA

Output current

Continuous

18.5 Arms

Max.

42 Arms

Main circuit power loss

Three-phase 200 V: 104.2 W
DC 270 V: 82.7 W

Regenerative resistor power loss

Three-phase 200 V: 30 W
DC 270 V: ―

Control circuit power loss

16 W

Total power loss

Three-phase 200 V: 120.2 W
DC 270 V: 98.7 W

Rated input current

Main circuit

Three-phase 200 V: 10 Arms
DC 270 V: 14 Arms

Control circuit

0.25 Arms

Rush current

Main circuit

34 A *3

Control circuit

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*4)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*5 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-300L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-300L2

General specifications

Capacity

3.0 kW

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 2.8 kg 6.17 lb

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/DC 270 V

Max. applicable motor capacity

3.0 kW

Power supply capacity for 1 amplifier

5.9 kVA

Output current

Continuous

19.6 Arms

Max.

56 Arms

Main circuit power loss

Three-phase 200 V: 114.2 W
DC 270 V: 83.5 W

Regenerative resistor power loss

Three-phase 200 V: 30 W
DC 270 V: ―

Control circuit power loss

16 W

Total power loss

Three-phase 200 V: 130.2 W
DC 270 V: 99.5 W

Rated input current

Main circuit

Three-phase 200 V: 15 Arms
DC 270 V: 20 Arms

Control circuit

0.25 Arms

Rush current

Main circuit

34 A *3

Control circuit

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*4)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*5

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*5 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-500L2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-500L2

General specifications

Capacity

5.0 kW

Input power supply

Voltage/frequency

Main circuit

3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Control circuit

Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2

Allowable frequency fluctuation

Main circuit/control circuit

±5% max.

Overvoltage category

III

Control mode

Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system

Feedback

Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback

Operating environment

Operating atmosphere

Enclosure rating

IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2
IP10:SV3-200L2/300L2/500L2

Pollution degree

2 (in an IP54 or higher control panel) However, the product must be used in the following environments:
• No corrosive or flammable gases
• No exposure to water, oil, or chemicals
• No dust

Operating ambient temperature

-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher)

Storage ambient temperature

-20 to +85°C -4 to +185°F (No freezing)

Operating/storage ambient temperature

95% RH or less (No condensation)

Altitude

No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher)

Vibration resistance

4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6)

Impact resistance

19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27)

Other

No static noise, strong electric or magnetic fields, or radiation

Applied standard

UL/CSA standards

UL 61800-5-1, CSA 22.2 No. 274

CE marking

Machinery Directive

EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Structure

Type

Base mount installation

Safety function

STO function (STO/EN 61800-5-2)

Safety function

Safety parameters

SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015

Response time

4 ms(max)

Input

STO1, STO2: Power module base block signals
Internal impedance: 5.1 kΩ
Operable voltage range: +24 V, ±20%
Max. delay time: 4 ms
(Time from when STO1 and STO2 are turned off until motor current is interrupted)

Output

EDM: Built-in safety circuit status monitoring (fixed output)
Max. allowable voltage: 30 VDC
Max. allowable current: 50 mA DC
Max. voltage drop at ON: 1.5 V
Max. delay time: 4 ms
(Time from STO1 and STO2 change to EDM change)

Protection function

Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc.

Min. insulation resistance

500 VDC 1 MΩ or more with insulation resistance meter

Insulation withstand voltage

1,500 VAC or more (between primary side and ground)
3,000 VAC or more (between primary and secondary)
350 VAC: between secondary circuit and ground

Weight

Approx. 4.4 kg 9.70 lb

Power supply/current capacity and power loss

Main circuit power supply

Three-phase 200 V/DC 270 V

Max. applicable motor capacity

5.0 kW

Power supply capacity for 1 amplifier

7.5 kVA

Output current

Continuous

32.9 Arms

Max.

84 Arms

Main circuit power loss

Three-phase 200 V: 226.6 W
DC 270 V: 146.2 W

Regenerative resistor power loss

Three-phase 200 V: 36 W
DC 270 V: ―

Control circuit power loss

19 W

Total power loss

Three-phase 200 V: 245.6 W
DC 270 V: 165.2 W

Rated input current

Main circuit

Three-phase 200 V: 25 Arms
DC 270 V: 34 Arms

Control circuit

0.3 Arms

Rush current

Main circuit

Three-phase 200 V: 68 A *3
DC 270 V: 68 A *3*4
(External: 5 Ω)

Control circuit

34 A *3

Performance specifications

Performance

Speed control range

1:5000 (Under conditions where load torque is equal to or less than rated torque)

Speed fluctuation rate

At load fluctuation

0 to 100% load variation: ±0.01% or less (at rated rotation speed)

At main circuit voltage change

Rated voltage ±10%: 0% (at rated rotation speed)

At ambient temperature change

Ambient temperature 0 to +50°C 32 to 122°F:
±0.1% or less (at rated rotation speed)

Torque control accuracy (reproducibility)

±1%

Velocity frequency response

3.1 kHz

Dynamic brake

Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP)

Regenerative resistor

Built-in regenerative resistor: Disabled at 50 to 400 W
Enabled at 750 W to 5.0 kW
External regenerative resistor: OP-84399 (50 W to 1.0 kW)
OP-87073 (1.5 kW*5)

Display Function

Panel function

7-segment LED
Two rotary switches (16 ch)

Communication status indicator LED

EtherCAT® communication: L/A × 2
EtherCAT® communication status: RUN×1
EtherCAT® error status: ERR×1

Servo functions

Tuning

Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc.

Monitor

Lifespan prediction, vibration, load factor, power consumption, temperature, etc.

I/O specifications

Sequence input signal

Number of inputs

7 (3 high-speed inputs, 4 general-purpose inputs)

Max. input voltage

28.8 VDC

Rated input voltage

24 VDC

Min. ON voltage

19 VDC

Max. OFF current/voltage

High-speed input: 0.1 mA, General-purpose input: 0.3 mA

Common point mode

7 points/1 common (1 terminal) (bidirectional)

Input time constant

250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms

Input current

High-speed input: 4.4 mA, General-purpose input: 4.5 mA

Input impedance

Approx. 5.1 kΩ

Assignable input signals

All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL)

Sequence output signal

Number of outputs

4

Output mode

Transistor NPN output

Rated load

30 VDC/50 mA

Leakage current when OFF

0.5 mA

Residual voltage when ON

1.5 VDC or less

Common point mode

Independent common

Assignable output signals

Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR)

Analog Feedback Input signal monitor

Max. input voltage

±12 V

Accuracy

±1% of F.S.

Resolution

±12 bits

Input impedance

30 kΩ

Encoder division pulse output signal

Output mode

A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output

Line driver

SN75ALS174 (T.I.) equivalent

Output frequency

1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*6

Analog monitor output

No. of channels

2 ch

Output range

±10 V (Linearity effective range: ±8 V)

Resolution

16 bits

Conversion precision

±20 mV (typ.)

Max. allowable load current

±10 mA

Conversion speed

1.2 ms (typ.)

Communication specifications

EtherCAT® communication

Applicable communication standards

IEC 61158 Type12,
IEC 61800-7 CiA402 Drive Profile

Physical layer

100 BASE-TX(IEEE802.3)

Cable

Category 5 STP, 2 pair
Automatic cable identification is performed by the AUTO MDI/MDI-X function.

Mailbox

Emergency messages, SDO requests, SDO responses

Distributed clocks

Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments)

Max. distance between stations

50 m 164.0'

USB communication

Connected device

PC

Communication standard

USB 2.0–compliant

Function

Status display, Parameter settings, Tuning, etc.

*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2.
*2 When using a DC power supply input, set “*AC/DC power supply” to “DC”.
*3 The inrush current duration is 20 ms or less when used at the above current levels.
*4 When using the SV3-500L2 with DC power input, connect an external inrush current protection circuit and design it so that the circuit follows the power on/off sequence recommended by KEYENCE.
Otherwise, the equipment may become damaged. Refer to the SV3 Series user’s manual for the power-on/off sequence.
*5 Depending on operating conditions, 2 kW, 3 kW, and 5 kW servo amplifiers can also be used.
*6 The frequency divider ratio can be set as desired with a parameter.

keyence Stock Image
Keyence SV3-B005AK Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B005AK *1

General specifications

Applicable servo amplifier

SV3-005L2

Rated output

50 W

Rated torque

0.159 N·m *2

Instant maximum torque

0.557 N·m

Rated current

0.55 Arms

Instant maximum current

2.0 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.316 N·m/Arms

Rotor moment of inertia

0.0537 ×10-4 kg·m2

Rated power rating

4.70 kW/s

Rated angle acceleration

29,600 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

35×

Approx. weight

0.6 kg 21.16 oz

Electromagnetic brake specifications

Capacity

5.5 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.23 A

Holding torque

0.159 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

keyence Stock Image
Keyence SV3-B005AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B005AS *1

General specifications

Applicable servo amplifier

SV3-005L2

Rated output

50 W

Rated torque

0.159 N·m *2

Instant maximum torque

0.557 N·m

Rated current

0.55 Arms

Instant maximum current

2.0 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.316 N·m/Arms

Rotor moment of inertia

0.0537 ×10-4 kg·m2

Rated power rating

4.70 kW/s

Rated angle acceleration

29,600 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

35×

Approx. weight

0.6 kg 21.16 oz

Electromagnetic brake specifications

Capacity

5.5 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.23 A

Holding torque

0.159 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

keyence Stock Image
Keyence SV3-B010AK Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B010AK *1

General specifications

Applicable servo amplifier

SV3-010L2

Rated output

100 W

Rated torque

0.318 N·m *2

Instant maximum torque

1.11 N·m

Rated current

0.85 Arms

Instant maximum current

3.1 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.413 N·m/Arms

Rotor moment of inertia

0.0785 ×10-4 kg·m2

Rated power rating

12.8 kW/s

Rated angle acceleration

40,500 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

35×

Approx. weight

0.7 kg 24.69 oz

Electromagnetic brake specifications

Capacity

5.5 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.23 A

Holding torque

0.318 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

keyence Stock Image
Keyence SV3-B010AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B010AS *1

General specifications

Applicable servo amplifier

SV3-010L2

Rated output

100 W

Rated torque

0.318 N·m *2

Instant maximum torque

1.11 N·m

Rated current

0.85 Arms

Instant maximum current

3.1 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.413 N·m/Arms

Rotor moment of inertia

0.0785 ×10-4 kg·m2

Rated power rating

12.8 kW/s

Rated angle acceleration

40,500 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

35×

Approx. weight

0.7 kg 24.69 oz

Electromagnetic brake specifications

Capacity

5.5 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.23 A

Holding torque

0.318 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

keyence Stock Image
Keyence SV3-B020AK Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B020AK *1

General specifications

Applicable servo amplifier

SV3-020L2

Rated output

200 W

Rated torque

0.637 N·m *2

Instant maximum torque

2.23 N·m

Rated current

1.6 Arms

Instant maximum current

5.8 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.444 N·m/Arms

Rotor moment of inertia

0.327 ×10-4 kg·m2

Rated power rating

12.4 kW/s

Rated angle acceleration

19,400 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

15×*3

Approx. weight

1.4 kg 3.09 lb

Electromagnetic brake specifications

Capacity

6 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.25 A

Holding torque

0.637 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 6,000 min-1. At 7,000 min-1, 200 W becomes 10×, 400 W becomes 5×, and 750 W becomes 8×.

keyence Stock Image
Keyence SV3-B020AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B020AS *1

General specifications

Applicable servo amplifier

SV3-020L2

Rated output

200 W

Rated torque

0.637 N·m *2

Instant maximum torque

2.23 N·m

Rated current

1.6 Arms

Instant maximum current

5.8 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.444 N·m/Arms

Rotor moment of inertia

0.327 ×10-4 kg·m2

Rated power rating

12.4 kW/s

Rated angle acceleration

19,400 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

15×*3

Approx. weight

1.4 kg 3.09 lb

Electromagnetic brake specifications

Capacity

6 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.25 A

Holding torque

0.637 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 6,000 min-1. At 7,000 min-1, 200 W becomes 10×, 400 W becomes 5×, and 750 W becomes 8×.

keyence Stock Image
Keyence SV3-B040AK Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B040AK *1

General specifications

Applicable servo amplifier

SV3-040L2

Rated output

400 W

Rated torque

1.27 N·m *2

Instant maximum torque

4.46 N·m

Rated current

2.5 Arms

Instant maximum current

9.3 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.544 N·m/Arms

Rotor moment of inertia

0.550 ×10-4 kg·m2

Rated power rating

29.3 kW/s

Rated angle acceleration

23,000 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

10×*3

Approx. weight

1.7 kg 3.75 lb

Electromagnetic brake specifications

Capacity

6 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.25 A

Holding torque

1.27 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 6,000 min-1. At 7,000 min-1, 200 W becomes 10×, 400 W becomes 5×, and 750 W becomes 8×.

keyence Stock Image
Keyence SV3-B040AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B040AS *1

General specifications

Applicable servo amplifier

SV3-040L2

Rated output

400 W

Rated torque

1.27 N·m *2

Instant maximum torque

4.46 N·m

Rated current

2.5 Arms

Instant maximum current

9.3 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.544 N·m/Arms

Rotor moment of inertia

0.550 ×10-4 kg·m2

Rated power rating

29.3 kW/s

Rated angle acceleration

23,000 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

10×*3

Approx. weight

1.7 kg 3.75 lb

Electromagnetic brake specifications

Capacity

6 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.25 A

Holding torque

1.27 N·m

Release time

60 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 6,000 min-1. At 7,000 min-1, 200 W becomes 10×, 400 W becomes 5×, and 750 W becomes 8×.

keyence Stock Image
Keyence SV3-B075AK Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B075AK *1

General specifications

Applicable servo amplifier

SV3-075L2

Rated output

750 W

Rated torque

2.39 N·m *2

Instant maximum torque

8.36 N·m

Rated current

4.4 Arms

Instant maximum current

16.9 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.584 N·m/Arms

Rotor moment of inertia

1.76 ×10-4 kg·m2

Rated power rating

32.4 kW/s

Rated angle acceleration

13,500 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

12×*3

Approx. weight

2.8 kg 6.17 lb

Electromagnetic brake specifications

Capacity

6.5 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.27 A

Holding torque

2.39 N·m

Release time

80 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 6,000 min-1. At 7,000 min-1, 200 W becomes 10×, 400 W becomes 5×, and 750 W becomes 8×.

keyence Stock Image
Keyence SV3-B075AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B075AS *1

General specifications

Applicable servo amplifier

SV3-075L2

Rated output

750 W

Rated torque

2.39 N·m *2

Instant maximum torque

8.36 N·m

Rated current

4.4 Arms

Instant maximum current

16.9 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.584 N·m/Arms

Rotor moment of inertia

1.76 ×10-4 kg·m2

Rated power rating

32.4 kW/s

Rated angle acceleration

13,500 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

12×*3

Approx. weight

2.8 kg 6.17 lb

Electromagnetic brake specifications

Capacity

6.5 W

Rated voltage

24 VDC ±10%

Rated current (@20°C 68°F)

0.27 A

Holding torque

2.39 N·m

Release time

80 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 6,000 min-1. At 7,000 min-1, 200 W becomes 10×, 400 W becomes 5×, and 750 W becomes 8×.

keyence Stock Image
Keyence SV3-B100AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B100AS *1

General specifications

Applicable servo amplifier

SV3-100L2

Rated output

0.85k W

Rated torque

5.39 N·m *2

Instant maximum torque

14.2 N·m

Rated current

6.9 Arms

Instant maximum current

17 Arms

Rated rotation speed

1,500 min-1

High rotation speed

4,000 min-1

Torque constant

0.859 N·m/Arms

Rotor moment of inertia

16.0 ×10-4 kg·m2

Rated power rating

18.2 kW/s

Rated angle acceleration

3,370 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right)
24.5 m/s2 80.4 ft/s2 (forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

Class F

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

*3

Approx. weight

7.5 kg 16.53 lb

Electromagnetic brake specifications

Capacity

10 W

Rated voltage

24 VDC (−0%/+10%)

Rated current (@20°C 68°F)

0.41 A

Holding torque

12.7 N·m

Release time

100 ms

Operating time

80 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 3,000 min-1. At 4,000 min-1, 1 kW becomes 2×, 1.5 kW becomes 2×, 3 kW (with the SV3-300L2 connected) becomes 2.2×, 3 kW (with the SV3-500L2 connected) becomes 4×, and 5 kW becomes 2.4×.

keyence Stock Image
Keyence SV3-B150AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B150AS *1

General specifications

Applicable servo amplifier

SV3-150L2

Rated output

1.3k W

Rated torque

8.34 N·m *2

Instant maximum torque

23.3 N·m

Rated current

10.7 Arms

Instant maximum current

28 Arms

Rated rotation speed

1,500 min-1

High rotation speed

4,000 min-1

Torque constant

0.891 N·m/Arms

Rotor moment of inertia

22.0 ×10-4 kg·m2

Rated power rating

31.6 kW/s

Rated angle acceleration

3,790 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right)
24.5 m/s2 80.4 ft/s2 (forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

Class F

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

*3

Approx. weight

9.0 kg 19.84 lb

Electromagnetic brake specifications

Capacity

10 W

Rated voltage

24 VDC (−0%/+10%)

Rated current (@20°C 68°F)

0.41 A

Holding torque

19.6 N·m

Release time

100 ms

Operating time

80 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 3,000 min-1. At 4,000 min-1, 1 kW becomes 2×, 1.5 kW becomes 2×, 3 kW (with the SV3-300L2 connected) becomes 2.2×, 3 kW (with the SV3-500L2 connected) becomes 4×, and 5 kW becomes 2.4×.

keyence Stock Image
Keyence SV3-B200AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B200AS *1

General specifications

Applicable servo amplifier

SV3-200L2

Rated output

1.8k W

Rated torque

11.5 N·m *2

Instant maximum torque

28.7 N·m

Rated current

16.7 Arms

Instant maximum current

42 Arms

Rated rotation speed

1,500 min-1

High rotation speed

4,000 min-1

Torque constant

0.748 N·m/Arms

Rotor moment of inertia

28.1 ×10-4 kg·m2

Rated power rating

47.1 kW/s

Rated angle acceleration

4,090 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right)
24.5 m/s2 80.4 ft/s2 (forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

Class F

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

Approx. weight

11.0 kg 24.25 lb

Electromagnetic brake specifications

Capacity

10 W

Rated voltage

24 VDC (−0%/+10%)

Rated current (@20°C 68°F)

0.41 A

Holding torque

19.6 N·m

Release time

100 ms

Operating time

80 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

keyence Stock Image
Keyence SV3-B300AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B300AS *1

General specifications

Applicable servo amplifier

SV3-300L2, SV3-500L2

Rated output

SV3-300L2: 2.4k W
SV3-500L2: 2.9k W

Rated torque

SV3-300L2: 15.1 N·m
SV3-500L2: 18.6 N·m
*2

Instant maximum torque

SV3-300L2: 45.1 N·m
SV3-500L2: 54.0 N·m

Rated current

SV3-300L2: 19.6 Arms
SV3-500L2: 23.8 Arms

Instant maximum current

SV3-300L2: 56 Arms
SV3-500L2: 70 Arms

Rated rotation speed

1,500 min-1

High rotation speed

4,000 min-1

Torque constant

0.826 N·m/Arms

Rotor moment of inertia

53.9 ×10-4 kg·m2

Rated power rating

SV3-300L2: 42.3 kW/s
SV3-500L2: 64.2 kW/s

Rated angle acceleration

SV3-300L2: 2,800 rad/s2
SV3-500L2: 3,450 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right)
24.5 m/s2 80.4 ft/s2 (forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

Class F

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

SV3-300L2: 3×
SV3-500L2: 5×
*3

Approx. weight

19.5 kg 42.99 lb

Electromagnetic brake specifications

Capacity

18.5 W

Rated voltage

24 VDC (−0%/+10%)

Rated current (@20°C 68°F)

0.77 A

Holding torque

43.1 N·m

Release time

170 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 3,000 min-1. At 4,000 min-1, 1 kW becomes 2×, 1.5 kW becomes 2×, 3 kW (with the SV3-300L2 connected) becomes 2.2×, 3 kW (with the SV3-500L2 connected) becomes 4×, and 5 kW becomes 2.4×.

keyence Stock Image
Keyence SV3-B500AS Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-B500AS *1

General specifications

Applicable servo amplifier

SV3-500L2

Rated output

4.4k W

Rated torque

28.4 N·m *2

Instant maximum torque

71.6 N·m

Rated current

32.8 Arms

Instant maximum current

84 Arms

Rated rotation speed

1,500 min-1

High rotation speed

4,000 min-1

Torque constant

0.932 N·m/Arms

Rotor moment of inertia

75.4 ×10-4 kg·m2

Rated power rating

107 kW/s

Rated angle acceleration

3,770 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right)
24.5 m/s2 80.4 ft/s2 (forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

Class F

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

*3

Approx. weight

23.5 kg 51.81 lb

Electromagnetic brake specifications

Capacity

18.5 W

Rated voltage

24 VDC (−0%/+10%)

Rated current (@20°C 68°F)

0.77 A

Holding torque

43.1 N·m

Release time

170 ms

Operating time

100 ms

*1 The open and operation times of the electromagnetic brake depend on the discharge circuit.
*2 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.
*3 This is the value at 3,000 min-1. At 4,000 min-1, 1 kW becomes 2×, 1.5 kW becomes 2×, 3 kW (with the SV3-300L2 connected) becomes 2.2×, 3 kW (with the SV3-500L2 connected) becomes 4×, and 5 kW becomes 2.4×.

keyence Stock Image
Keyence SV3-M005AK Keyence
Sale price$0.00
Sold Out

Specifications

Model

SV3-M005AK

General specifications

Applicable servo amplifier

SV3-005L2

Rated output

50 W

Rated torque

0.159 N·m *1

Instant maximum torque

0.557 N·m

Rated current

0.55 Arms

Instant maximum current

2.0 Arms

Rated rotation speed

3,000 min-1

High rotation speed

7,000 min-1

Torque constant

0.316 N·m/Arms

Rotor moment of inertia

0.0457 ×10-4 kg·m2

Rated power rating

5.53 kW/s

Rated angle acceleration

34,700 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

26 bit

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20% to 80% RH (No condensation)

Operating atmosphere

Indoors (No corrosive gas, flammable gas, oil mist, or dust)

Altitude

2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8 ft/s2 with servo motor flange surface as reference
(3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: Class A, CE: Class B

Min. insulation resistance

500 VDC 10 MΩ or more with insulation resistance meter

Isolation voltage tolerance

1,500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part 15 B, ICES-003. Class A

Allowable load inertia moment

35×

Approx. weight

0.3 kg 10.58 oz

*1 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

Recently viewed