Specifications
Model |
SJ-E036A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
420 mm 16.54"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
5 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
670 g 23.63oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E036H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
420 mm 16.54"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
680 g 23.99oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E036L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
440 mm 17.32"*3 |
|||
Total length |
350 mm 13.78" |
|||
No. ofelectrodes |
5 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
670 g 23.63oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E060A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
660 mm 25.98"*3 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
850 g 29.98oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E060H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
660 mm 25.98"*3 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
17 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
870 g 30.69oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E060L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
680 mm 26.77"*3 |
|||
Total length |
560 mm 22.05" |
|||
No. ofelectrodes |
9 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
850 g 29.98oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E084A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
900 mm 35.43"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
13 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1070 g 37.74oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E084H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
900 mm 35.43"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
25 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1100 g 38.80oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E084L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
920 mm 36.22"*3 |
|||
Total length |
800 mm 31.50" |
|||
No. ofelectrodes |
13 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1070 g 37.74oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E108A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1140 mm 44.88"*3 |
|||
Total length |
1040 mm 40.94" |
|||
No. ofelectrodes |
17 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1270 g 44.80oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E108H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1140 mm 44.88"*3 |
|||
Total length |
1040 mm 40.94" |
|||
No. ofelectrodes |
33 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1300 g 45.86oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E108L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1160 mm 45.67"*3 |
|||
Total length |
1040 mm 40.94" |
|||
No. ofelectrodes |
17 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1270 g 44.80oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E132A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1380 mm 54.33"*3 |
|||
Total length |
1280 mm 50.39" |
|||
No. ofelectrodes |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1500 g 52.91oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E132H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1380 mm 54.33"*3 |
|||
Total length |
1280 mm 50.39" |
|||
No. ofelectrodes |
41 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1550 g 54.67oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E132L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1400 mm 55.12"*3 |
|||
Total length |
1280 mm 50.39" |
|||
No. ofelectrodes |
21 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1500 g 52.91oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E156A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1620 mm 63.78"*3 |
|||
Total length |
1520 mm 59.84" |
|||
No. ofelectrodes |
25 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1700 g 59.97oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E156H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1620 mm 63.78"*3 |
|||
Total length |
1520 mm 59.84" |
|||
No. ofelectrodes |
49 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1750 g 61.73oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E156L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1640 mm 64.57"*3 |
|||
Total length |
1520 mm 59.84" |
|||
No. ofelectrodes |
25 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1700 g 59.97oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E180A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1860 mm 73.23"*3 |
|||
Total length |
1760 mm 69.29" |
|||
No. ofelectrodes |
29 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1900 g 67.02oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E180H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1860 mm 73.23"*3 |
|||
Total length |
1760 mm 69.29" |
|||
No. ofelectrodes |
57 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1950 g 68.78oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E180L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1880 mm 74.02"*3 |
|||
Total length |
1760 mm 69.29" |
|||
No. ofelectrodes |
29 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1900 g 67.02oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E204A |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
2100 mm 82.68"*3 |
|||
Total length |
2000 mm 78.74" |
|||
No. ofelectrodes |
33 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2100 g 74.08oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E204H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
2100 mm 82.68"*3 |
|||
Total length |
2000 mm 78.74" |
|||
No. ofelectrodes |
65 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2150 g 75.84oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
SJ-E204L |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
2120 mm 83.46"*3 |
|||
Total length |
2000 mm 78.74" |
|||
No. ofelectrodes |
33 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
2100 g 74.08oz |
|||
*1 Measured under the following conditions. | ||||