
Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
97.8 mm
86.55 mm
0.31 kg
Technical
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
480 A
25 ... 32 A
(400 V) Three Phase 15 kW
(400 V) Three Phase 15 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
32 A
32 A
32 A
32 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 1.9 ... 3.1 W
3P
Main Circuit 32 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Main Circuit 2 N·m
Main Circuit 10 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 27 A
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 27 A
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 146 A
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 146 A
(600 V AC) 32 A
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Main Circuit 18 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
102 mm
50 mm
0.325 kg
4013614400155
carton 40 piece
280 mm
395 mm
210 mm
13.386 kg
4013614409059
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3705999
4364083
3112130

Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
90 mm
86.75 mm
0.215 kg
Technical
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 100 kA
(690 V AC) 100 kA
12.5 A
None
(400 V) Three Phase 0.25 kW
(400 V) Three Phase 0.25 kW
Main Circuit 690 V AC
1 A
1 A
1 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 1.7 W
3P
Main Circuit 1 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Main Circuit 0.8 ... 1.2 N·m
Main Circuit 9 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 47 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 47 kA
Main Circuit 600 V AC
(550 ... 600 V AC) Three Phase 0.5 Hp
(200 V AC) Three Phase 1 A
(208 V AC) Three Phase 1 A
(220 ... 240 V AC) Three Phase 1 A
(440 ... 480 V AC) Three Phase 1 A
(550 ... 600 V AC) Three Phase 1 A
(200 V AC) Three Phase 1 A
(208 V AC) Three Phase 1 A
(220 ... 240 V AC) Three Phase 1 A
(440 ... 480 V AC) Three Phase 1 A
(550 ... 600 V AC) Three Phase 1 A
(200 V AC) Three Phase 6 A
(208 V AC) Three Phase 6 A
(220 ... 240 V AC) Three Phase 6 A
(440 ... 480 V AC) Three Phase 6 A
(550 ... 600 V AC) Three Phase 6 A
(200 V AC) Three Phase 6 A
(208 V AC) Three Phase 6 A
(220 ... 240 V AC) Three Phase 6 A
(440 ... 480 V AC) Three Phase 6 A
(550 ... 600 V AC) Three Phase 6 A
(600 V AC) 1 A
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Main Circuit 10 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
No
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
95 mm
50 mm
0.23 kg
4013614400209
carton 40 piece
280 mm
395 mm
210 mm
9.586 kg
4013614443657
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3705883
4364089
3110033

Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
90 mm
86.75 mm
0.265 kg
Technical
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
78.8 A
None
(400 V) Three Phase 2.2 kW
(400 V) Three Phase 2.2 kW
Main Circuit 690 V AC
6.3 A
6.3 A
6.3 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 1.1 W
3P
Main Circuit 6.3 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Main Circuit 0.8 ... 1.2 N·m
Main Circuit 9 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 1 Hp
(208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
(200 V AC) Three Phase 1 Hp
(208 V AC) Three Phase 1 Hp
(220 ... 240 V AC) Three Phase 1.5 Hp
(440 ... 480 V AC) Three Phase 3 Hp
(550 ... 600 V AC) Three Phase 5 Hp
(200 V AC) Three Phase 6.3 A
(208 V AC) Three Phase 6.3 A
(220 ... 240 V AC) Three Phase 6.3 A
(440 ... 480 V AC) Three Phase 4.8 A
(550 ... 600 V AC) Three Phase 6.1 A
(200 V AC) Three Phase 6.3 A
(208 V AC) Three Phase 6.3 A
(220 ... 240 V AC) Three Phase 6.3 A
(440 ... 480 V AC) Three Phase 4.8 A
(550 ... 600 V AC) Three Phase 6.1 A
(200 V AC) Three Phase 37.8 A
(208 V AC) Three Phase 37.8 A
(220 ... 240 V AC) Three Phase 37.8 A
(440 ... 480 V AC) Three Phase 32 A
(550 ... 600 V AC) Three Phase 36.8 A
(200 V AC) Three Phase 37.8 A
(208 V AC) Three Phase 37.8 A
(220 ... 240 V AC) Three Phase 37.8 A
(440 ... 480 V AC) Three Phase 32 A
(550 ... 600 V AC) Three Phase 36.8 A
(600 V AC) 6.3 A
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Main Circuit 10 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
No
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
95 mm
50 mm
0.28 kg
4013614400247
carton 40 piece
280 mm
395 mm
210 mm
11.586 kg
4013614443695
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3705887
4364093
3110037

Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
90 mm
86.75 mm
0.265 kg
Technical
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
125 A
None
(400 V) Three Phase 4 kW
(400 V) Three Phase 4 kW
Main Circuit 690 V AC
10 A
10 A
10 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 2.2 W
3P
Main Circuit 10 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Main Circuit 0.8 ... 1.2 N·m
Main Circuit 9 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
(200 V AC) Three Phase 2 Hp
(208 V AC) Three Phase 2 Hp
(220 ... 240 V AC) Three Phase 3 Hp
(440 ... 480 V AC) Three Phase 5 Hp
(550 ... 600 V AC) Three Phase 7.5 Hp
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
(200 V AC) Three Phase 7.8 A
(208 V AC) Three Phase 7.5 A
(220 ... 240 V AC) Three Phase 9.6 A
(440 ... 480 V AC) Three Phase 7.6 A
(550 ... 600 V AC) Three Phase 9 A
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
(200 V AC) Three Phase 57.5 A
(208 V AC) Three Phase 55 A
(220 ... 240 V AC) Three Phase 64 A
(440 ... 480 V AC) Three Phase 46 A
(550 ... 600 V AC) Three Phase 50.8 A
(600 V AC) 10 A
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Main Circuit 10 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
No
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
95 mm
50 mm
0.28 kg
4013614400254
carton 40 piece
280 mm
395 mm
210 mm
11.586 kg
4013614443701
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3705888
4364094
3110038

Ordering
1 piece
85362010
Popular Downloads
Dimensions
45 mm
97.8 mm
86.55 mm
0.31 kg
Technical
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
(230 V AC) 100 kA
(400 V AC) 100 kA
(440 V AC) 20 kA
(500 V AC) 20 kA
(690 V AC) 3 kA
200 A
None
(400 V) Three Phase 7.5 kW
(400 V) Three Phase 7.5 kW
Main Circuit 690 V AC
16 A
16 A
16 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 400 Hz
Main Circuit 6 kV
690 V
at Rated Operating Conditions per Pole 1.9 W
3P
Main Circuit 16 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
50000 cycle
Nr. Operations 100000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Main Circuit 1.5 N·m
Main Circuit 10 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 3 Hp
(208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(200 V AC) Three Phase 3 Hp
(208 V AC) Three Phase 3 Hp
(220 ... 240 V AC) Three Phase 5 Hp
(440 ... 480 V AC) Three Phase 10 Hp
(550 ... 600 V AC) Three Phase 10 Hp
(200 V AC) Three Phase 11 A
(208 V AC) Three Phase 10.6 A
(220 ... 240 V AC) Three Phase 15.2 A
(440 ... 480 V AC) Three Phase 14 A
(550 ... 600 V AC) Three Phase 11 A
(200 V AC) Three Phase 11 A
(208 V AC) Three Phase 10.6 A
(220 ... 240 V AC) Three Phase 15.2 A
(440 ... 480 V AC) Three Phase 14 A
(550 ... 600 V AC) Three Phase 11 A
(200 V AC) Three Phase 73.6 A
(208 V AC) Three Phase 71 A
(220 ... 240 V AC) Three Phase 92 A
(440 ... 480 V AC) Three Phase 81 A
(550 ... 600 V AC) Three Phase 64.8 A
(200 V AC) Three Phase 73.6 A
(208 V AC) Three Phase 71 A
(220 ... 240 V AC) Three Phase 92 A
(440 ... 480 V AC) Three Phase 81 A
(550 ... 600 V AC) Three Phase 64.8 A
(600 V AC) 16 A
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Main Circuit 18 in·lb
Environmental
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +60 °C
Storage -50 ... +80 °C
No
2000 m
11 ms Pulse 25g
5g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
92 mm
102 mm
50 mm
0.325 kg
4013614400261
carton 40 piece
280 mm
395 mm
210 mm
13.386 kg
4013614443718
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3705890
4364096
3110039

Ordering
1 piece
85369010
Popular Downloads
Dimensions
115 mm
53 mm
22 mm
0.1 kg
Technical
690 V AC
125 A
8 kV
6P
IP20
3
IEC/EN 60947-4-1
Technical UL/CSA
Main Circuit 600 V AC
Environmental
Operation -25 ... +40 °C
Storage -50 ... +80 °C
Operation -25 ... +40 °C
Storage -50 ... +80 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 10 piece
80 mm
150 mm
80 mm
1.046 kg
4013614502194
External Classifications and Standards
W
EC000215 - Phase busbar
EC000215 - Phase busbar
V11.0 : 27371306
39121117
4378 >> Phase busbar
4364160
3110211

Ordering
1 piece
85369010
Popular Downloads
Dimensions
225 mm
53 mm
22 mm
0.226 kg
Technical
690 V AC
125 A
8 kV
IP20
3
IEC/EN 60947-4-1
Technical UL/CSA
Main Circuit 600 V AC
Environmental
Operation -25 ... +40 °C
Storage -50 ... +80 °C
Operation -25 ... +40 °C
Storage -50 ... +80 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 10 piece
230 mm
270 mm
160 mm
2.452 kg
4013614502217
External Classifications and Standards
W
EC000215 - Phase busbar
EC000215 - Phase busbar
V11.0 : 27371306
39121117
4378 >> Phase busbar
4364162
3110213

Ordering
10 piece
85389099
Popular Downloads
Dimensions
55 mm
24 mm
69.5 mm
0.019 kg
Technical
IEC/EN 60947-4-1
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Product Not in WEEE Scope
Certificates and Declarations
Container Information
box 10 piece
250 mm
250 mm
250 mm
0.201 kg
4013614506635
carton 140 piece
280 mm
395 mm
210 mm
3.265 kg
4013614506628
External Classifications and Standards
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
V11.0 : 27371392
39122221
5219 >> Switch part or accessory
3707447
4364484
3110217

Ordering
1 piece
85369010
Popular Downloads
Dimensions
54 mm
65 mm
59.3 mm
0.172 kg
Technical
690 V AC
250 V DC
690 V AC
250 V DC
125 A
3P
IP20
Screw Terminals
Flexible 1x 10 ... 50 mm²
Rigid 1x 10 ... 50 mm²
Flexible 1x 10 ... 50 mm²
Rigid 1x 10 ... 50 mm²
Main Circuit 6 N·m
Main Circuit 16 mm
IEC/EN 60947-1
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC/EN 60947-1
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
UL/CSA Type E/F and IEC
Technical UL/CSA
Main Circuit 600 V AC
Flexible 1x 8-0 AWG
Stranded 1x 8-0 AWG
Flexible 1x 8-0 AWG
Stranded 1x 8-0 AWG
Main Circuit 54 in·lb
Environmental
Operation -25 ... +60 °C
Storage -50 ... +85 °C
Operation -25 ... +60 °C
Storage -50 ... +85 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
2ade4f22-d224-4870-8572-2f6afc73f2e4 Germany
2202b237-fff3-49ca-982b-5b63ec0fcbfd Germany
c110aeb1-456a-4225-8dcf-cdd07d579697 France
225084f3-949f-44dc-9c24-47601fe6d997 Germany
e5740a91-846c-44d3-bf16-ed3b4581502c Finland
982c546b-3e45-4cfa-b772-2181daf12a28 Sweden
0ec21bcf-a57c-4350-b02d-97604b9b2788 Italy
c7fb676f-c044-43b4-a88c-6d2eb0af53e9 Netherlands
2cccbf9d-54e0-4d0a-b766-b1c9feb792d1 Estonia
f4c2790f-2e2e-4c90-bb51-a0f669b73e18 Greece
dba769f9-d66d-4416-9aa5-a2bc6486251e Bulgaria
b41998db-1c9f-48cd-aa26-e9c8b24e0574 Poland
11ea5fb6-292a-40c4-b60a-aa931583bc0b France
9e686ed5-2bc0-472a-aed4-c525c221543f Spain
49438c16-905c-46ab-8320-e8ca15a61cc8 Germany
667e85f1-6302-42d2-9f2b-dda490cbb5dd Denmark
7b6ad2ec-2afe-4b2a-9757-933d2fec2d2b Germany
903da8ea-c1a5-424c-b640-e4e4b7014fa9 Hungary
cb3d615c-0c28-4973-be8a-b7c456bbd57a Sweden
6bef615d-397f-46b4-a16c-876db70c2751 Belgium
49c21700-6a66-4b21-9fdd-83d6a05ccb3e Belgium
6f7c17b6-b1e2-4178-9951-4bb87c86c4f3 Norway
7a68fea5-691c-45ad-8e06-77e3658f82db Poland
7a79ac9c-42f3-4105-a46a-0a4a4f1052be Croatia
509c98fa-41db-4fe7-a9a1-6e014b838ca6 Czech Republic
a21ed621-d578-4555-ba32-04368b431ba5 Poland
931e3a3c-12bb-48ef-80d4-ffa401e7d11b Hungary
56df1229-a648-4e2c-98a7-9328271915d9 Portugal
2202b237-fff3-49ca-982b-5b63ec0fcbfd Germany
c110aeb1-456a-4225-8dcf-cdd07d579697 France
225084f3-949f-44dc-9c24-47601fe6d997 Germany
e5740a91-846c-44d3-bf16-ed3b4581502c Finland
982c546b-3e45-4cfa-b772-2181daf12a28 Sweden
0ec21bcf-a57c-4350-b02d-97604b9b2788 Italy
c7fb676f-c044-43b4-a88c-6d2eb0af53e9 Netherlands
2cccbf9d-54e0-4d0a-b766-b1c9feb792d1 Estonia
f4c2790f-2e2e-4c90-bb51-a0f669b73e18 Greece
dba769f9-d66d-4416-9aa5-a2bc6486251e Bulgaria
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
80 mm
59 mm
64 mm
0.19 kg
4013614555725
External Classifications and Standards
X
EC000275 - Main line branch terminal
EC000275 - Main line branch terminal
V11.0 : 27400603
39121410
4561 >> Power Blocks & Distribution Blocks

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.




Ordering
1 piece
85362010
Popular Downloads
Dimensions
55 mm
142.65 mm
122.1 mm
0.97 kg
Technical
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
(230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
(230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
480 A
23 ... 32 A
(400 V) Three Phase 15 kW
(400 V) Three Phase 15 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
32 A
32 A
32 A
32 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 415 Hz
Main Circuit 8 kV
1000 V
at Rated Operating Conditions per Pole 2.27 ... 4.40 W
3P
Main Circuit 32 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
25000 cycle
Nr. Operations 50000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Main Circuit 4 N·m
Main Circuit 16 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 32 A
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 32 A
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 174 A
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 174 A
(600 V AC) 32 A
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Main Circuit 35 in·lb
Environmental
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
64 mm
177 mm
140 mm
1.1 kg
4013614486081
carton 12 piece
330 mm
400 mm
320 mm
13 kg
4013614503948
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3707287
4364123
3110054

Ordering
1 piece
85362010
Popular Downloads
Dimensions
55 mm
142.65 mm
122.1 mm
0.97 kg
Technical
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
810 A
40 ... 54 A
(400 V) Three Phase 22 kW
(400 V) Three Phase 22 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
54 A
54 A
54 A
54 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 415 Hz
Main Circuit 8 kV
1000 V
at Rated Operating Conditions per Pole 3.84 ... 6.99 W
3P
Main Circuit 54 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
25000 cycle
Nr. Operations 50000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Main Circuit 4 N·m
Main Circuit 16 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 15 Hp
(208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 15 Hp
(208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 48.3 A
(208 V AC) Three Phase 46.2 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
(200 V AC) Three Phase 48.3 A
(208 V AC) Three Phase 46.2 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
(200 V AC) Three Phase 267 A
(208 V AC) Three Phase 257 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 290 A
(550 ... 600 V AC) Three Phase 290 A
(200 V AC) Three Phase 267 A
(208 V AC) Three Phase 257 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 290 A
(550 ... 600 V AC) Three Phase 290 A
(600 V AC) 54 A
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Main Circuit 35 in·lb
Environmental
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
64 mm
177 mm
140 mm
1.1 kg
4013614486104
carton 12 piece
330 mm
400 mm
320 mm
13 kg
4013614503962
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3707289
4364125
3110056

Ordering
1 piece
85362090
Popular Downloads
Dimensions
55 mm
142.65 mm
122.1 mm
0.98 kg
Technical
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
975 A
52 ... 65 A
(400 V) Three Phase 30 kW
(400 V) Three Phase 30 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
65 A
65 A
65 A
65 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 415 Hz
Main Circuit 8 kV
1000 V
at Rated Operating Conditions per Pole 5.14 ... 8.02 W
3P
Main Circuit 65 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
25000 cycle
Nr. Operations 50000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Main Circuit 4 N·m
Main Circuit 16 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
(200 V AC) Three Phase 20 Hp
(208 V AC) Three Phase 20 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 50 Hp
(550 ... 600 V AC) Three Phase 60 Hp
(200 V AC) Three Phase 62.1 A
(208 V AC) Three Phase 59.4 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(200 V AC) Three Phase 62.1 A
(208 V AC) Three Phase 59.4 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 65 A
(550 ... 600 V AC) Three Phase 62 A
(200 V AC) Three Phase 334 A
(208 V AC) Three Phase 321 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 363 A
(550 ... 600 V AC) Three Phase 348 A
(200 V AC) Three Phase 334 A
(208 V AC) Three Phase 321 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 363 A
(550 ... 600 V AC) Three Phase 348 A
(600 V AC) 65 A
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Main Circuit 35 in·lb
Environmental
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
64 mm
177 mm
140 mm
1.1 kg
4013614486111
carton 12 piece
330 mm
400 mm
320 mm
13 kg
4013614503979
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3707290
4364126
3110057

Ordering
1 piece
85362090
Popular Downloads
Dimensions
55 mm
142.65 mm
122 mm
1 kg
Technical
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 18 kA
(500 V AC) 10 kA
(690 V AC) 6 kA
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 18 kA
(500 V AC) 10 kA
(690 V AC) 6 kA
(230 V AC) 30 kA
(250 V DC) 100 kA
(400 V AC) 30 kA
(440 V AC) 18 kA
(500 V AC) 10 kA
(690 V AC) 8 kA
(230 V AC) 30 kA
(250 V DC) 100 kA
(400 V AC) 30 kA
(440 V AC) 18 kA
(500 V AC) 10 kA
(690 V AC) 8 kA
1120 A
70 ... 80 A
(400 V) Three Phase 45 kW
(400 V) Three Phase 45 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
80 A
80 A
80 A
80 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 415 Hz
Main Circuit 8 kV
1000 V
at Rated Operating Conditions per Pole 6.27 ... 8.33 W
3P
Main Circuit 80 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
20000 cycle
Nr. Operations 50000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Main Circuit 4 N·m
Main Circuit 16 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 10 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 10 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 10 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 10 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 10 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 50 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 10 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 25 Hp
(208 V AC) Three Phase 25 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
(200 V AC) Three Phase 25 Hp
(208 V AC) Three Phase 25 Hp
(220 ... 240 V AC) Three Phase 30 Hp
(440 ... 480 V AC) Three Phase 60 Hp
(550 ... 600 V AC) Three Phase 75 Hp
(110 ... 120 V AC) Three Phase 56 A
(200 V AC) Three Phase 78.2 A
(208 V AC) Three Phase 74.8 A
(220 ... 240 V AC) Three Phase 80 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
(110 ... 120 V AC) Three Phase 56 A
(200 V AC) Three Phase 78.2 A
(208 V AC) Three Phase 74.8 A
(220 ... 240 V AC) Three Phase 80 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
(200 V AC) Three Phase 420 A
(208 V AC) Three Phase 404 A
(220 ... 240 V AC) Three Phase 435 A
(440 ... 480 V AC) Three Phase 435 A
(550 ... 600 V AC) Three Phase 434 A
(200 V AC) Three Phase 420 A
(208 V AC) Three Phase 404 A
(220 ... 240 V AC) Three Phase 435 A
(440 ... 480 V AC) Three Phase 435 A
(550 ... 600 V AC) Three Phase 434 A
(600 V AC) 80 A
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Main Circuit 35 in·lb
Environmental
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Yes
2000 m
11 ms Pulse 25g
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
64 mm
177 mm
140 mm
1.1 kg
4013614536632
carton 12 piece
330 mm
400 mm
320 mm
13 kg
4013614537820
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3708084
4364128
3110789

Ordering
1 piece
85362010
Popular Downloads
Dimensions
55 mm
142.65 mm
122.1 mm
0.97 kg
Technical
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
(230 V AC) 100 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
(230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
(230 V AC) 100 kA
(250 V DC) 100 kA
(400 V AC) 100 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
480 A
None
(400 V) Three Phase 15 kW
(400 V) Three Phase 15 kW
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
32 A
32 A
32 A
32 A
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
0 ... 415 Hz
Main Circuit 8 kV
1000 V
4.4 W
3P
Main Circuit 32 A
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
3
25000 cycle
Nr. Operations 50000 cycle
Screw Terminals
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Main Circuit 4 N·m
Main Circuit 16 mm
Pozidriv 2
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Rotary Handle
ON / OFF / TRIP
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
For overload protection of the motors, an appropriate thermal or electronic overload relays must be used
Technical UL/CSA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Main Circuit 600 V AC
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 30 Hp
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 32 A
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 32 A
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 174 A
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 174 A
(600 V AC) 32 A
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Main Circuit 35 in·lb
Environmental
Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +60 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
No
2000 m
11 ms Pulse 25g
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
64 mm
177 mm
140 mm
1.1 kg
4013614486159
carton 12 piece
330 mm
400 mm
320 mm
13 kg
4013614504013
External Classifications and Standards
F
EC000074 - Motor protection circuit-breaker
EC000074 - Motor protection circuit-breaker
V11.0 : 27370401
39121521
4731 >> Manual Starters
3707294
4364143
3110141

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

MANUAL MOTOR STARTER, SHORT CIRCUIT BREAKING CAPACITY - 230-400 V AC, 450 V DC / 690 V AC, 50/60 HZ, 45-63 AMP, 3 PHASE, 30 KW, 3 POLES



