Variable Frequency Drives

25001 products

Showing 505 - 528 of 25001 products

Showing 505 - 528 of 25001 products
View
Lenze New Stock Image
Lenze EVS9325-ES Lenze
Sale price $5,837.02
In stock, 17 units

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Hitachi New Stock Image
Hitachi SJH300-8LF Hitachi
Sale price $792.00
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Delta Stock Image
Delta VFD9A0MS43AFSAA Delta
Sale price $703.50
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

VFD13AMS43ANSAA Delta
Delta VFD13AMS43ANSAA Delta
Sale price $416.00
Only 8 units left

Standard Models (0-599 Hz) Without EMC Filter Part Number: Delta VFD13AMS43ANSAA Nominal Input VAC: 480 Volts AC Input Range VAC: 460 Volts AC HP: 7.5 HP Amps (HD): 13A Amps (ND): 15.7A Input Phase: 3PH Operator Controls: Sold Separately, See Accessories Brake Type: DC Injection; Dynamic Braking Motor Control-Max Level: Open Loop Vector-(Sensorless Vector) Closed Loop: NO AC Line Regenerative: NO Dynamic Braking Trans: Included Enclosure Rating: IP20 Frame Size: D1 Height: 8.15 Inches Width: 4.29 Inches Depth: 6.06 Inches Net Weight: 8 Lbs. Delta’s MS300 series is a standard compact vector control drive that inherits Delta’s superior drive technology. It supports both IM and PM motor control for application flexibility and provides STO safety mechanism. Also built-in various essential functions, including PLC capacity for simple programming needs, a communication slot for various communication cards, and a USB port to make data uploads and downloads fast and easy. Saving space, reducing setup and wiring time, while providing high efficiency and stability system,all included in the MS300 series with drive size reduced up to 40%. Delta VFD MS300 Micro Drive Accessories

Delta Stock Image
Delta VFD022E23A Delta
Sale price $655.34
Only 3 units left
Buy the Delta Electronics VFD022E23A Variable Frequency Drive (VFD) - an AC motor speed controller providing precise voltage and frequency regulation for three-phase induction motors. Features V/f and vector control, built-in EMC filtering, configurable ramps, and motor protection. The Delta Electronics VFD022E23A is designed for pumps, fans, conveyors, and general-purpose motor control. Direct replacement for existing installations.
Delta Stock Image
Delta AS218PX-A Delta
Sale price $1,113.56
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Control Techniques Stock Image
Control Techniques C200-03400056 Control Techniques
Sale price $540.87
In stock, 11 units

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Control Techniques New Stock Image
Control Techniques SP1402 Control Techniques
Sale price $2,349.59
In stock, 19 units
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Control Techniques New Stock Image
Control Techniques SP3403 Control Techniques
Sale price $4,621.29
Only 6 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Control Techniques New Stock Image
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ACS580-01-03A4-4 ABB
ABB ACS580-01-03A4-4 ABB
Sale price $467.00
Only 7 units left

ACS580 IP21 0.75kW/1.1kW 400V 3ph AC Inverter, HMI, DBr, STO, C2 EMC

ABB New Stock Image
ABB 3AXD50000025965 ABB
Sale price $259.68
Only 8 units left
2CSF202401R1250 ABB - F202 A-25/0.03 AP-R

ABB EcoSolutions

ABB EcoSolutions:
Yes
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 82.05 %
ABB Site Meeting Group Waste To Landfill Target:
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
No non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %):
Recycled Paper - 00 %
Recycled Paper - 04 %
Recycled Cardboard - 29 %
Recycled Cardboard - 61 %
Recycled Cardboard - 03 %
Recycled Paper - 00 %
Recycled Paper - 04 %
Recycled Cardboard - 29 %
Recycled Cardboard - 61 %
Recycled Cardboard - 03 %
Extended Product Lifetime:
Product Durability
End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Technical

Type of Residual Current:
Type A APR
Test Voltage (Ut):
170-254 V
Maximum Surge Current:
3 kA
Leakage Current Type:
A
Power Supply Connection:
Arbitrary
Electrical Endurance:
10000 cycle
Mechanical Endurance:
20000 cycle
Number of Poles:
2P
Number of Modular Spacings per DIN Rail:
2
Operating Characteristic:
Instantaneous
Tightening Torque:
2.8 N·m
Accessory Type:
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Motor Operating Device
Bottom fitting auxiliary contact
Autoreclosing Unit
Home automatic resetting unit
Auxiliary contact
Auxiliary/Signal contact
Shunt trip
Undervoltage release
Overvoltage release
Motor Operating Device
Bottom fitting auxiliary contact
Autoreclosing Unit
Home automatic resetting unit
Screw Terminal Type:
Failsafe Bi-directional Cylinder-lift Terminal
Cage Terminal
Failsafe Biconnect Fork Top/Bottom
Failsafe Biconnect Fork Bottom
Failsafe Bi-directional Cylinder-lift Terminal
Cage Terminal
Failsafe Biconnect Fork Top/Bottom
Failsafe Biconnect Fork Bottom
Options Provided:
None
Accessories Available:
Yes
Connecting Capacity:
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²
Busbar 10 mm²
Rigid 25 ... 25 mm²
Flexible 25 ... 25 mm²
Rated Cross-Section:
4 - Multi-Wired 0...25 mm²
1 - Solid-Core 25...25 mm²
4 - Multi-Wired 0...25 mm²
1 - Solid-Core 25...25 mm²
Wire Stripping Length:
12 mm
Terminal Type:
Screw Terminals

Electrical

Rated Voltage (Ur):
230 V
Rated Operational Voltage:
230 V
Rated Insulation Voltage (Ui):
500 V
Rated Impulse Withstand Voltage (Uimp):
4 kV
Input Voltage Type:
AC
Rated Current (In):
25 A
Rated Residual Current:
30 mA
Rated Conditional Short-Circuit Current (Inc):
10 kA
Frequency (f):
50/60 Hz
Rated Frequency (f):
50 … 60 Hz
Power Loss:
at Rated Operating Conditions per Pole 1 W
Total 2 W
at Rated Operating Conditions per Pole 1 W
Total 2 W

Design

Number of Modules:
2

Technical UL/CSA

Maximum Operating Voltage UL/CSA:
277 V AC

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date:
20211115
REACH Information:
True - contains substances > 0.1 mass percentage
REACH Date:
20240429
Conflict Minerals Reporting Template (CMRT):
SCIP:
18f132b0-8f03-4611-9c59-dba03cc369bf Italy
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2B:
Business To Consumer

Environmental

Ambient Air Temperature:
Operation -25 ... 55 °C
Storage -40 ... 70 °C
Operation -25 ... 55 °C
Storage -40 ... 70 °C
Degree of Protection:
Terminals IP20
Housing IP40
Terminals IP20
Housing IP40
Pollution Degree:
2
Resistance to Vibrations:
20 Cycles with Load 0.8 In: 1g or 1mm 5 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-27:
25g 2 shocks 13 ms
Environmental Information:

Dimensions

Width in Number of Modular Spacings:
2
Product Net Width:
35 mm
Product Net Height:
85 mm
Product Net Depth / Length:
69 mm
Product Net Weight:
200 g
Built-In Depth (t2):
69 mm

Engineering

EPLAN Data:

Ordering

Package Level 1 Units:
box 1 piece
Package Level 1 Gross Weight:
0.235 kg
E-Number (Finland):
3259656
E-Number (Norway):
1662937
E-Number (Sweden):
2160175

Certificates and Declarations

Declaration of Conformity - CE:

Installation

Instructions and Manuals:
Mounting Type:
DIN-Rail
Mounting Position:
Any

Popular Downloads

External Classifications and Standards

ETIM 9:
EC000003 - Residual current circuit breaker (RCCB)
ETIM 10:
EC000003 - Residual current circuit breaker (RCCB)
UNSPSC:
39121601
eClass:
V11.0 : 27142201
IDEA Granular Category Code (IGCC):
4875 >> Residual current circuit breaker (RCCB)
Object Classification Code:
F
Standards:
IEC/EN 61008
UL 1053
IEC/EN 61008
UL 1053
1SAZ321201R1003 ABB - TA75DU-42
ABB 1SAZ321201R1003 ABB - TA75DU-42
Sale price $346.50
Only 1 unit left

TA75DU-42 Thermal Overload Relay 29 ... 42 A

ACS800-U1-0011-5 ABB
ABB ACS800-U1-0011-5 ABB
Sale price $1,449.99
Only 5 units left

WALL MOUNTED AC DRIVE, 3-PHASE, 380-500 V AC, 50/60 HZ, 10 HP, W/ OPTIONS

ACH550-VCR-06A9-4 ABB
ABB ACH550-VCR-06A9-4 ABB
Sale price $1,199.98
Only 2 units left

DRIVE, 3HP, 100KA, 6.9AMP, 380-480V, 3PH, 48-63HZ.

1SAM451000R1016 ABB - MS165-54
ABB 1SAM451000R1016 ABB - MS165-54
Sale price $229.59
Only 7 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362010

Dimensions

Product Net Width:
55 mm
Product Net Height:
142.65 mm
Product Net Depth / Length:
122.1 mm
Product Net Weight:
0.97 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 100 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
(230 V AC) 50 kA
(250 V DC) 100 kA
(400 V AC) 50 kA
(440 V AC) 45 kA
(500 V AC) 20 kA
(690 V AC) 8 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
810 A
Setting Range:
40 ... 54 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 22 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 22 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie):
54 A
Rated Operational Current AC-3 (Ie):
54 A
Rated Operational Current AC-3e (Ie):
54 A
Rated Operational Current DC-5 (Ie):
54 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (fsw):
0 ... 415 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 8 kV
Rated Insulation Voltage (Ui):
1000 V
Power Loss:
at Rated Operating Conditions per Pole 3.84 ... 6.99 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 54 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
25000 cycle
Mechanical Durability:
Nr. Operations 50000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Flexible with Ferrule 1/2x 1 ... 35 mm²
Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque:
Main Circuit 4 N·m
Wire Stripping Length:
Main Circuit 16 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:
Rotary Handle
Contact Position Indication:
ON / OFF / TRIP
Standards:
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1
CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 15 Hp
(208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
(200 V AC) Three Phase 15 Hp
(208 V AC) Three Phase 15 Hp
(220 ... 240 V AC) Three Phase 20 Hp
(440 ... 480 V AC) Three Phase 40 Hp
(550 ... 600 V AC) Three Phase 50 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 48.3 A
(208 V AC) Three Phase 46.2 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
(200 V AC) Three Phase 48.3 A
(208 V AC) Three Phase 46.2 A
(220 ... 240 V AC) Three Phase 54 A
(440 ... 480 V AC) Three Phase 52 A
(550 ... 600 V AC) Three Phase 52 A
Locked Rotor Amps:
(200 V AC) Three Phase 267 A
(208 V AC) Three Phase 257 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 290 A
(550 ... 600 V AC) Three Phase 290 A
(200 V AC) Three Phase 267 A
(208 V AC) Three Phase 257 A
(220 ... 240 V AC) Three Phase 290 A
(440 ... 480 V AC) Three Phase 290 A
(550 ... 600 V AC) Three Phase 290 A
General Use Rating UL/CSA:
(600 V AC) 54 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Flexible 1/2x 16-0 AWG
Stranded 1/2x 16-0 AWG
Tightening Torque UL/CSA:
Main Circuit 35 in·lb

Environmental

Ambient Air Temperature:
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz
Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

ABB EcoSolutions

End Of Life Disassembling Instructions:
Environmental Product Declaration - EPD:

Certificates and Declarations

ATEX Certificate:
LR Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
64 mm
Package Level 1 Depth / Length:
177 mm
Package Level 1 Height:
140 mm
Package Level 1 Gross Weight:
1.1 kg
Package Level 1 EAN:
4013614486104
Package Level 2 Units:
carton 12 piece
Package Level 2 Width:
330 mm
Package Level 2 Depth / Length:
400 mm
Package Level 2 Height:
320 mm
Package Level 2 Gross Weight:
13 kg
Package Level 2 EAN:
4013614503962

External Classifications and Standards

Object Classification Code:
F
ETIM 9:
EC000074 - Motor protection circuit-breaker
ETIM 10:
EC000074 - Motor protection circuit-breaker
eClass:
V11.0 : 27370401
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4731 >> Manual Starters
E-Number (Finland):
3707289
E-Number (Norway):
4364125
E-Number (Sweden):
3110056
3HAC044075-001 ABB
ABB 3HAC044075-001 ABB
Sale price $368.54
Only 2 units left

Battery Unit 3HAC044075-001

ACS380-040S-03A3-4 ABB
ABB ACS380-040S-03A3-4 ABB
Sale price $489.50
In stock, 12 units

ACS380-040S-03A3-4 PN: 1.1kW, IN: 3.3A; The ACS380 machinery drive comes in several variants, ensuring seamless integration into machines and connecting perfectly to automation systems. It’s a great fit for industries such as food and beverage, material handling and textile. Typical applications include mixers, conveyors, EOT and tower cranes, extruders, and textile machinery. With the integrated functional safety features, the ACS380 drive can be also part of the machine’s safety system via PROFIsafe over PROFINET, ensuring the motor is safely stopped when required. In addition, the drive’s software can be easily customized with adaptive programming to match any specific application requirements.

1SFA898120R7000 ABB
ABB 1SFA898120R7000 ABB
Sale price $9,362.49
Only 3 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85371091

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals:
Instructions and Manuals (Part 2):
Instructions and Manuals (Part 3):
EPLAN Data:
Wiring Diagram:

Dimensions

Product Net Width:
435 mm
Product Net Height:
515 mm
Product Net Depth / Length:
367 mm
Product Net Weight:
62.3 kg

Technical

Rated Operational Voltage:
208 ... 600 V AC
Rated Control Supply Voltage (Us):
100 ... 250 V AC
Rated Control Circuit Voltage (Uc):
24 V DC
Rated Frequency (f):
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe):
(230 V) 315 kW
(400 V) 560 kW
(500 V) 730 kW
(230 V) 315 kW
(400 V) 560 kW
(500 V) 730 kW
Rated Operational Current - In-Line Connection (Ie):
1050 A
Rated Operational Power - Inside Delta Connection:
at 230 V 500 kW
at 400 V 1000 kW
at 500 V 1250 kW
at 230 V 500 kW
at 400 V 1000 kW
at 500 V 1250 kW
Rated Operational Current - Inside Delta Connection:
1810 A
Service Factor Percentage:
100 %
Overload Protection:
Built-in electronic overload protection
Integrated Electronic Overload:
Yes
Starting Capacity at Maximum Rated Current Ie:
4xIe for 10s
Ramp Time:
1 ... 120 second [unit of time]
Initial Voltage During Start:
10 ... 99 %
Step Down Voltage Special Ramp:
100 ... 10 %
Current Limit Function:
1.5 ... 7.5 xle
Switch for Inside Delta Connection:
Yes
Run Signal Relay:
Yes
By-pass Signal Relay:
Yes
Fault Signal Relay:
Yes
Overload Signal Relay:
Yes
Analog Outputs:
0…10 V, 0…20 mA, 4…20 mA
Signal Indication Ready to Start/Standby ON (LED):
Green
Signal Indication Running R (LED):
Green
Signal Indication Protection (LED):
Yellow
Signal Indication Fault (LED):
Red
Communication:
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
Degree of Protection:
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type:
Main Circuit: Bars
Connecting Capacity Control Circuit:
Rigid 1 x 2.5 mm²
Connecting Capacity Supply Circuit:
Rigid 1 x 2.5
Tightening Torque:
Main Circuit 45 N·m
Product Main Type:
PSTX1050
Function:
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Protection Function:
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Warning Details:
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning

Technical UL/CSA

Horsepower Rating UL/CSA:
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 450 Hp
(440 ... 480 V AC) Three Phase 900 Hp
(550 ... 600 V AC) Three Phase 1000 Hp
(200 ... 208 V AC) Three Phase 400 Hp
(220 ... 240 V AC) Three Phase 450 Hp
(440 ... 480 V AC) Three Phase 900 Hp
(550 ... 600 V AC) Three Phase 1000 Hp
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V
Tightening Torque UL/CSA:
Main Circuit 398.3

Environmental

Ambient Air Temperature:
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)

Certificates and Declarations

Container Information

Package Level 1 Width:
600 mm
Package Level 1 Depth / Length:
616 mm
Package Level 1 Height:
800 mm
Package Level 1 Gross Weight:
74.3 kg
Package Level 1 EAN:
7320500510445
Package Level 1 Units:
box 1 piece

External Classifications and Standards

Object Classification Code:
Q
ETIM 7:
EC000640 - Soft starter
ETIM 8:
EC000640 - Soft starter
ETIM 9:
EC000640 - Soft starter
eClass:
V11.0 : 27370907
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4740 >> Soft starter
ACS355-03E-02A4-2 ABB
ABB ACS355-03E-02A4-2 ABB
Sale price $487.50
Only 5 units left

ACS355 0.37kW 230V 3ph to 3ph AC Inverter Drive, STO, C3 EMC

1SAM150000R1007 ABB - MS325-2.5
ABB 1SAM150000R1007 ABB - MS325-2.5
Sale price $130.65
In stock, 12 units

MS325-2.5 Manual Motor Starter 1.6 ... 2.5 A

ABB New Stock Image
ABB 3AUA0000072069 ABB
Sale price $348.84
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ACS580-01-052A-4 ABB
ABB ACS580-01-052A-4 ABB
Sale price $6,860.00
Only 3 units left

40HP, 3-Phase, 380-480V, Nema 1 Enclosure, Variable Frequency Drive

Recently viewed