Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| Product or Component Type | Current transformer |
| Accessory / separate part category | Measurement accessory |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | PowerLogic PowerLogic PM5000 power meter PowerLogic PowerLogic PM3000 power meter Acti 9 Acti9 iEM3000 energy meter EasyLogic EasyLogic PM2100 power meter EasyLogic EasyLogic PM2200 power meter |
| Current transformer type | Split core |
| Primary operational current | 800 A |
| Secondary current | 5 A |
| Network type | AC |
| Network Frequency | 50 Hz 60 Hz |
| Current transformer ratio | 800/5 |
| Electrical connection | 8 ft (2.4 m) AWG 16 flying lead |
| Insulation | Basic insulation 600 V AC Reinforced insulation 300 V AC |
| Measurement accuracy | 1 % |
| Mounting Location | Indoor use only |
| Width | Internal: 2.46 in (62.48 mm) Total: 5.83 in (148.08 mm) |
| Depth | 1.12 in (28.45 mm) |
| Height | Internal: 2.9 in (73.7 mm) Total: 5.36 in (136.14 mm) |
| Product Weight | 38.7 oz (1097 g) |

This flexible core current transducer, designed for retrofit installation, has a line rated current of 50A to 5000A. The coil can be wrapped around a maximum cable outer diameter of 146mm. Measurement accuracy plus or minus 1% from 50A to 5000A. A flying lead of 2.4 meters is available to connect the transducer to a meter. This product received the cURus certification, and is UL recognized.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| Product or Component Type | Current transducer |
| Accessory / separate part category | Measurement accessory |
| Range compatibility | Acti 9 Acti9 iEM3000 iEM3555 Acti 9 Acti9 iEM3000 iEM3565 PowerLogic PowerLogic EM4200 EM4235 PowerLogic PowerLogic EM4200 EM4236 PowerLogic PowerLogic EM3500 EM3502A PowerLogic PowerLogic EM3500 EM3550A PowerLogic PowerLogic EM3500 EM3555A PowerLogic PowerLogic EM3500 EM3560A PowerLogic PowerLogic EM3500 EM3561A |
| Current transformer type | Flexible core |
Complementary
| Characteristic | Value(s) |
|---|---|
| Electrical connection | Flying lead 7.9 ft (2.4 m)600 V |
| Measurement current | 50â¦5000 A |
| Network Frequency | 50 Hz |
| Frequency measurement range | 50â¦1500 Hz |
| Measurement accuracy | 1 % |
| Installation category | IV |
| pollution degree | 2 |
| Thickness | 0.3 in (8 mm) |
| Height | Opened: 18.1 in (460 mm) |
| Diameter | closed 5.7 in (146 mm) |




This current transformer, tropicalised for busbar, has a line rated current of 1500 A and a secondary current rating of 5 A. This current transformer do have a 55 mm x 129 mm opening. Compatible with a single output for bar: 102 mm x 54 mm. Burden and accuracy class as follows: class 0.5 maximum power: 20 VA, class 1 maximum power: 25 VA.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | CT |
| Product or component type | Current transformer |
| Secondary current | 5 A |
| Accuracy class | Class 0.5 at 20 VA Class 1 at 25 VA |
| [In] rated current | 1500 A |
Complementary
| Characteristic | Value(s) |
|---|---|
| Current transformer type | Tropicalised for busbar |
| Current transformer ratio | 1500/5 |
| [Ith] conventional free air thermal current | 60 kA |
| Dynamic withstand current | 2.5 Ith |
| Maximum safety factor | 5 |
| [Ue] rated operational voltage | < 720 V AC 50/60 Hz |
| [Ui] rated insulation voltage | 3 kV |
| Mounting mode | Insulated locking screw |
| Mounting support | Busbar |
| Width | Inner: 55 mm Outside: 135 mm |
| Height | Outside: 129 mm Inner: 103 mm |
| Depth | Frame : 50 mm Total : 85 mm |
| Product weight | 0.692 kg |
| [Uimp] rated impulse withstand voltage | 3 kV |
| Electrical insulation class | Class B |
| Opening of bars | 102 x 54 |
| Sealing | With |


This current transformer, tropicalised for busbar, has a line rated current of 4000 A and a secondary current rating of 5 A. This current transformer do have a 55 mm x 128 mm opening. Compatible with a single output for bar: 127 mm x 52 mm. Burden and accuracy class as follows: class 0.5 maximum power: 30 VA, class 1 maximum power: 50 VA.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | CT |
| Product or component type | Current transformer |
| Secondary current | 5 A |
| Accuracy class | Class 0.5 at 30 VA Class 1 at 50 VA |
| [In] rated current | 4000 A |
Complementary
| Characteristic | Value(s) |
|---|---|
| Current transformer type | Tropicalised for busbar |
| Current transformer ratio | 4000/5 |
| [Ith] conventional free air thermal current | 60 kA |
| Dynamic withstand current | 2.5 Ith |
| Maximum safety factor | 5 |
| [Ue] rated operational voltage | < 720 V AC 50/60 Hz |
| [Ui] rated insulation voltage | 3 kV |
| Mounting mode | Insulated locking screw |
| Mounting support | Busbar |
| Width | Outside: 125 mm Inner: 55 mm |
| Height | Outside: 160 mm Inner: 128 mm |
| Depth | Frame : 40 mm Total : 87 mm |
| Product weight | 1.282 kg |
| [Uimp] rated impulse withstand voltage | 3 kV |
| Electrical insulation class | Class B |
| Opening of bars | 127 x 52 |
| Sealing | With |

This current transformer, tropicalised for busbar, has a line rated current of 2500 A and a secondary current rating of 5 A. This current transformer do have a 38 mm x 127 mm opening. Compatible with a single output for bar: 127 mm x 38 mm. Burden and accuracy class as follows: class 0.5 maximum power: 20 VA, class 1 maximum power: 25 VA.
Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| product name | CT |
| Product or component type | Current transformer |
| Secondary current | 5 A |
| Accuracy class | Class 0.5 at 20 VA Class 1 at 25 VA |
| [In] rated current | 2500 A |
Complementary
| Characteristic | Value(s) |
|---|---|
| Current transformer type | Tropicalised for busbar |
| Current transformer ratio | 2500/5 |
| [Ith] conventional free air thermal current | 60 kA |
| Dynamic withstand current | 2.5 Ith |
| Maximum safety factor | 5 |
| [Ue] rated operational voltage | < 720 V AC 50/60 Hz |
| [Ui] rated insulation voltage | 3 kV |
| Mounting mode | Insulated locking screw |
| Mounting support | Busbar |
| Width | Inner: 38 mm Outside: 99 mm |
| Height | Inner: 127 mm Outside: 160 mm |
| Depth | Frame : 40 mm Total : 78.4 mm |
| Product weight | 1.082 kg |
| [Uimp] rated impulse withstand voltage | 3 kV |
| Electrical insulation class | Class B |
| Opening of bars | 127 x 38 |
| Sealing | With |


Main
| Characteristic | Value(s) |
|---|---|
| Range | PowerLogic |
| Product or Component Type | Mounting hardware |
| Accessory / separate part category | Adaptation accessory |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | PowerLogic PowerLogic ION9000 energy and power quality meter |
| Kit composition | Nut Washer Adaptor plate Gasket Instruction sheet |







Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | PacDrive 3 |
| Device short name | LXM 62 |
| Product or Component Type | Double drive |
| Component name | LXM62 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product compatibility | Servo motor SHS Servo motor SH3 2.2 in (55 mm), 1 optimized in terms of torque and speed Servo motor SH3 2.2 in (55 mm), 2 optimized in terms of torque and speed Servo motor SH3 2.2 in (55 mm), 3 optimized in terms of torque and speed Servo motor SH3 2.8 in (70 mm), 1 optimized in terms of torque and speed Servo motor SH3 2.8 in (70 mm), 2 optimized in terms of high torque Servo motor SH3 2.8 in (70 mm), 3 optimized in terms of high torque Servo motor SH3 3.9 in (100 mm), 1 optimized in terms of high torque Servo motor MH3 2.8 in (70 mm), 1 optimized in terms of torque and speed |
| Phase | Three phase |
| [Us] rated supply voltage | 400 V - 10...10 %)three phase 230 V - 10...10 %)three phase 230 V - 10...10 %)single phase |
| Supply frequency | 50/60 Hz - 5...5 % |
| Continuous output current | 2 A 4 kHz |
| Output current 3s peak | 6 A 4 kHz |
| Continuous power | 0.95 kW |
| Nominal power | 0.95 kW |
| Switching frequency | 8 kHz |
| Overvoltage category | III |
| Electrical connection | Terminal 0.2...15 mm², AWG 24...AWG 16 CN4) Terminal 0.5...16 mm², AWG 20...AWG 6 CN5) Terminal 0.75...16 mm², AWG 18...AWG 6 CN6) Terminal 0.2...6 mm², AWG 24...AWG 10 CN7) |
| Tightening torque | CN1 22.1 lbf.in (2.5 N.m) |
| Number of inputs | 2 digital 2 touch probe |
| Discrete input voltage | 24 V DC for - 20...25 % |
| Number of outputs | 2 digital |
| Discrete output voltage | 24 V DC |
| Safety function | STO (safe torque off) SS1 (safe stop 1) SS2 (safe stop 2) SOS (safe operating stop) SMS (safe maximum speed) SLS (safe limited speed) SDI (safe direction indication) |
| Communication interface | SERCOS III, Integrated |
| Depth | 10.6 in (270 mm) |
| Height | 12.2 in (310 mm) |
| Width | 1.8 in (44.5 mm) |
| Product Weight | 6.6 lb(US) (3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | PacDrive 3 |
| Product or component type | Mounting kit |
| Accessory / separate part category | Mounting and fixing accessory |
| Accessory / separate part destination | Lexium 62 |
| Range compatibility | Lexium 62 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product weight | 3.1 kg |



This product is part of the PacDrive 3 range, an offer of power supplies for integrated drives. The power supply module features SERCOS III communication interface. It offers 2 relay outputs for volt-free contacts. It is a power supply module with a rated supply voltage of 400V three phase, 230V three/single phase and a rated supply current of 10A single/three phase AC. It is an IP20 rated product. Its dimensions are 89.5mm (width) x 270mm (depth) x 310mm (height). It weighs 6.3kg. It is suitable for use in general machine control, packaging machine automation, material handling applications. This product is certified by CE and CSA. It meets EN/IEC 61800-5-1, EN/IEC 61800-3 and UL 508C standards. Lexium 62 ILM integrated servo modules can be controlled with all PacDrive LMC Eco and Pro/Pro 2 series motion controllers via SERCOS communication. Multiaxis integrated servo drives from 0.31kW to 1.91kW for automation solutions based on PacDrive 3.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | PacDrive 3 |
| Product or Component Type | Power supply |
| Component name | LXM62 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply circuit type | AC |
| [Us] rated supply voltage | 400 V three phase - 10...10 %) 230 V three phase - 10...10 %) 230 V single phase - 10...10 %) |
| Supply frequency | 50/60 Hz +/- 5 % |
| [Uc] control circuit voltage | 24 V DC - 20...25 %) |
| Power supply output current | 20 A |
| Bus voltage | 270â¦700 V |
| Maximum DC bus voltage | 860 V |
| Maximum cable capacity | 1.36 mF |
| Line Rated Current | 10 A single phase AC 10 A three phase AC |
| Peak current | 20 kA single phase AC 1 s 20 kA three phase AC 1 s |
| Nominal power | 5.2 kW 400 V three phase AC 6.2 kW 480 V three phase AC |
| Maximum power | 10.4 kW 400 V three phase AC 12.5 kW 480 V three phase AC |
| Holding time | 15 min |
| Braking resistance | 15 Ohm |
| Permanent braking power | 400 W |
| Maximum braking power | 46 kW |
| Output type | 2 relays volt-free contacts |
| Physical interface | SERCOS III |
| Marking | CE |
| Safety level | Can reach SIL 2 IEC 61508 Can reach PL d/category 3 ISO 13849-1 |
| Overvoltage category | III conforming to IEC 61800-5-1 |
| Depth | 10.6 in (270 mm) |
| Width | 3.5 in (89.5 mm) |
| Height | 12.2 in (310 mm) |
| Product Weight | 13.9 lb(US) (6.3 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range of product | PacDrive 3 |
| Device short name | LXM 62 |
| Product or component type | Double drive |
| Component name | LXM62 |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network number of phases | Three phase |
| [Us] rated supply voltage | 400 V (- 10...10 %) for three phase 230 V (- 10...10 %) for three phase 230 V (- 10...10 %) for single phase |
| Supply frequency | 50/60 Hz - 5...5 % |
| Continuous output current | 2 A at 4 kHz |
| Output current 3s peak | 6 A |
| Switching frequency | 8 kHz |
| Overvoltage category | III |
| Electrical connection | Terminal, clamping capacity: 0.2...15 mm², AWG 24...AWG 16 (CN4) Terminal, clamping capacity: 0.5...16 mm², AWG 20...AWG 6 (CN5) Terminal, clamping capacity: 0.75...16 mm², AWG 18...AWG 6 (CN6) Terminal, clamping capacity: 0.2...6 mm², AWG 24...AWG 10 (CN7) |
| Tightening torque | CN1: 2.5 N.m |
| Number of inputs | 2 digital 2 touch probe |
| Discrete input voltage | 24 V DC for - 20...25 % |
| Number of outputs | 2 digital |
| Discrete output voltage | 24 V DC |
| Safety function | STO (safe torque off) |
| Communication interface | SERCOS III, integrated |
| Product weight | 3 kg |