This Acti 9 iATLc is reliable centralized control auxiliary. Control voltage is between 24VAC and 240VAC. Mounting is performed on the right of iTL impulse relay with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is associated with iTL impulse relays to allow centralized control of a group of impulse relays. This product is compliant with EN/IEC 60669-2-2.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Device short name | iATLc |
| Product or component type | Centralized control auxiliary |
| [Uc] control circuit voltage | 24...240 V AC 50/60 Hz impulse |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 440 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Remote control type | 2 entries for switch |
| Mounting mode | Fixed, on right side of TL |
| Mounting support | DIN rail |
| 9 mm pitches | 1 |
| Height | 81 mm |
| Width | 9 mm |
| Depth | 69 mm |
| Colour | White |
| Connections - terminals | Tunnel type terminals0.5â¦4 mm² - rigid Tunnel type terminals0.5â¦4 mm² - rigid - with cable end Tunnel type terminals1â¦4 mm² - flexible Tunnel type terminals1â¦4 mm² - flexible - with cable end |
| Wire stripping length | 11 mm |
| Tightening torque | 1 N.m |
| Range compatibility | Acti9 iTL Acti9 iTLi Acti9 iTLs |
| Product compatibility | ITL (32 A) ITL (16 A) |

This Acti 9 iATLc+s is reliable centralized control and remote indication auxiliary. It has 1 changeover contact, and it operates with 24VAC to 240VAC control voltage. Mounting is performed on the right of iTL impulse relay with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is associated with iTL impulse relays allow centralized control of a group of impulse relays. This product is compliant with EN/IEC 60669-2-2.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Device short name | iATLc+s |
| Product or component type | Centralized control and remote indication auxiliary |
| Signal contacts composition | 1 C/O |
| Signalling circuit voltage | 24 V AC/DC: 10 mA 12...240 V AC: 50/60 Hz 6 A 12...24 V DC: 6 A 15...240 V AC: 50/60 Hz 2 A 13...24 V DC: 2 A |
| [Uc] control circuit voltage | 24...240 V AC 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 440 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Mounting mode | Fixed, on right side of TL |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 86 mm |
| Width | 18 mm |
| Depth | 71 mm |
| Colour | White |
| Connections - terminals | Tunnel type terminals0.5â¦4 mm² - rigid Tunnel type terminals0.5â¦4 mm² - rigid - with cable end Tunnel type terminals1â¦4 mm² - flexible Tunnel type terminals1â¦4 mm² - flexible - with cable end |
| Wire stripping length | 11 mm |
| Tightening torque | 1 N.m |
| Range compatibility | Acti9 iTL Acti9 iTLi Acti9 iTLs |
| Product compatibility | ITL (32 A) ITL (16 A) |

This Acti 9 iATLm is reliable latched control auxiliary. Is operates with 12VAC to 240VAC control voltage. Mounting is performed on the right of iTL impulse relay with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is associated with iTL impulse relays to allow latched type control orders from a changeover contact. This product is compliant with EN/IEC 60669-2-2.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| Device short name | iATLm |
| Product or component type | Latched control auxiliary |
| [Uc] control circuit voltage | 12...240 V AC 50/60 Hz maintained |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 440 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Remote control type | 2 entries for switch |
| Mounting mode | Fixed, on right side of TL |
| Mounting support | DIN rail |
| 9 mm pitches | 1 |
| Height | 81 mm |
| Width | 9 mm |
| Depth | 69 mm |
| Colour | White |
| Connections - terminals | Tunnel type terminals0.5â¦4 mm² - rigid Tunnel type terminals0.5â¦4 mm² - rigid - with cable end Tunnel type terminals1â¦4 mm² - flexible Tunnel type terminals1â¦4 mm² - flexible - with cable end |
| Wire stripping length | 11 mm |
| Tightening torque | 1 N.m |
| Range compatibility | Acti9 iTL Acti9 iTLi Acti9 iTLs |
| Product compatibility | ITL (16 A) ITL (32 A) |

This Acti 9 iATEt is reliable time delay auxiliary. It operates from 24VAC to 240VAC and 24VDC to 110VDC control voltage. Mounting is performed on the left of iTL impulse relay or iCT contactor with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. 5 time delays are possible, 1 for iTL and 4 for iCT. This product is compliant with EN/IEC 60669-2-2.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| Product or component type | Time delay auxiliary |
| Device short name | iATEt |
| [Uc] control circuit voltage | 24...110 V DC impulse 24...240 V AC 50/60 Hz maintained |
Complementary
| Characteristic | Value(s) |
|---|---|
| Type of setting | Time delay configuration |
| Time delay range | 2 s...10 min 2 s...10 h 6...60 s 1...10 s 6 s...1 h |
| Maximum output current | 0.2 A holding 3 A inrush |
| Hold-in power consumption in VA | 5 VA |
| Mounting mode | Fixed, on the left of TL or CT |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 81 mm |
| Width | 18 mm |
| Depth | 60 mm |
| Colour | White |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 4 kV |
| [Ui] rated insulation voltage | 440 V |
| Standards | EN/IEC 60669-2-2 |
| Connections - terminals | Output connection: yellow clips Input connection: tunnel type terminals 2 cable(s) 2.5 mm² flexible Input connection: tunnel type terminals 2 cable(s) 1.5 mm² rigid |
| Wire stripping length | 9 mm |
| Tightening torque | 0.8 N.m |
| Range compatibility | Acti9 iCT Acti9 iTL |
| Market segment | Small commercial Residential |
| Compatibility code | IATEt |

This Acti9 CDSc is single-phase load-shedder for 1 pole installation with 1 relay per phase. When the consumption exceeds the selected threshold, it temporarily cuts off the power supply to non-priority circuits. It increases the number of loads without modifying the installed power. The load-shedding and restoration in cascading configuration of 4 non-priority circuits via 4 relays with time-delayed action. This device reduces the installed power and prevents nuisance tripping of the upstream circuit breaker. The Iu Rated current is 5A to 90A. The Rated current (control contacts) is 1A. The Ui insulation voltage is 230VAC. The Ue operating voltage is 230VAC +/- 10%. The operating frequency is 50Hz or 60Hz. The power consumption is 12VA. The active power is 20kW maximum. The connection is done with rigid coper cables 10mm² to 50mm² or flexible or with ferrule copper cables 10mm² to 35mm². The dimensions are (W) 144mm x (H) 77mm x (D) 60mm. The width in 9mm pitches is 16. The weight is 600g. The degree of protection is IP20 and IP40 for a device in modular enclosure. The Operating temperature is -5°C to +50°C. The Storage temperature is -40°C to +70°C. It complies with NF C 61.750 and EN 500.81.1 standards.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 CDS |
| Product or component type | Load-shedding contactor |
| Device short name | CDSc |
| Number of channels | 4 |
| Control and monitoring type | Cascade |
| Poles description | 1P |
Complementary
| Characteristic | Value(s) |
|---|---|
| Setting | 40 10 90 30 5 45 75 15 50 20 25 60 |
| Power consumption in VA | 4 VA |
| [Ue] rated operational voltage | 230 V AC - 15...10 % at 50/60 Hz |
| Rated current | 15 A for non-priority circuit Adjustable from 5 to 90 A for priority circuit |
| Local signalling | Load-shedding indication: 4 LEDs (yellow) |
| Mounting support | 35 mm symmetrical DIN rail Panel mounting Wall mounted |
| 9 mm pitches | 16 |
| Connections - terminals | Non-priority circuit: screw terminal2.5â¦10 mm² flexible Non-priority circuit: screw terminal2.5â¦10 mm² rigid Priority circuit: screw terminal10â¦35 mm² flexible Priority circuit: screw terminal10â¦50 mm² rigid |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Height | 77 mm |
| Width | 144 mm |
| Depth | 60 mm |
| Product weight | 0.6 kg |
| Colour | White (RAL 9003) |
| Tightening torque | Non-priority circuit: 2 N.m Priority circuit: 3.5 N.m |
| Wire stripping length | 12 mm 13 mm |

This Acti 9 iACTs is reliable remote indication auxiliary. It has 1 changeover contact, it operates from 24VAC to 240VAC and 24VDC to 130VDC. Mounting is performed on the right of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is compatible with all Acti9 iCT Contactors. This product helps reporting the status of a contactor and is especially required in a connected environment. This product is compliant with EN 60947-5.
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | ICT |
| Range | Acti9 |
| Device short name | iACTs |
| Product or component type | Remote indication auxiliary |
| Signal contacts composition | 1 C/O |
Complementary
| Characteristic | Value(s) |
|---|---|
| Signalling circuit voltage | 24 V AC/DC: 10 mA 230 V AC: 50/60 Hz 5 A 230 V AC: 50/60 Hz 2 A 130 V DC: 1 A |
| [Uc] control circuit voltage | 24...240 V AC 50/60 Hz 24...130 V DC |
| Range compatibility | Acti9 iCT |
| [Ui] rated insulation voltage | 440 V |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Mounting mode | Fixed, on the right of CT |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 1 |
| Height | 81 mm |
| Width | 9 mm |
| Depth | 68 mm |
| Colour | White |
| Auxiliary connection terminal | Tunnel type terminals 2 cable(s) flexible 2.5 mm² Tunnel type terminals 2 cable(s) rigid 1.5 mm² Tunnel type terminals 1 cable(s) rigid 1.5â¦2.5 mm² Tunnel type terminals 1 cable(s) flexible 1.5â¦2.5 mm² |
| Wire stripping length | 9 mm |
| Tightening torque | 0.8 N.m |
| Product compatibility | ICT |
| Market segment | Residential Small commercial |
| Compatibility code | IACTs |

This Acti 9 iACTp is modular and reliable overvoltage protection auxiliary (2 circuits). It operates from 12VAC to 48VAC, at a frequency of 50/60 Hz. Mounting is performed on the left of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. it si compatible only with Acti9 iCT greater or equal than 25A. This auxiliary is an interference suppressor which limits overvoltage on the control circuit. This product is compliant with IEC/EN 61095.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| Product or component type | Overvoltage protection auxiliary (2 circuits) |
| Device short name | iACTp |
| [Uc] control circuit voltage | 12...48 V AC 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Type of setting | Time delay configuration |
| Time delay range | 1...36000 s |
| Hold-in power consumption in VA | 3 VA |
| Mounting mode | Fixed, on the left of CT |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 81 mm |
| Width | 18 mm |
| Depth | 60 mm |
| Colour | White |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 4 kV |
| [Ui] rated insulation voltage | 440 V |
| Standards | IEC/EN 61095 |
| Connections - terminals | Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 1.5â¦2.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 1.5â¦2.5 mm² flexible with ferrule Control circuit: yellow clips |
| Wire stripping length | 9 mm |
| Tightening torque | 0.8 N.m |
| Range compatibility | Acti9 iCT |
| Market segment | Residential Small commercial |
| Compatibility code | IACTp |

This Acti 9 iACTp is modular and reliable overvoltage protection auxiliary (2 circuits). It operates from 220VAC to 240VAC, at a frequency of 50/60 Hz. Mounting is performed on the left of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. it si compatible only with Acti9 iCT greater or equal than 25A. This auxiliary is an interference suppressor which limits overvoltage on the control circuit. This product is compliant with IEC/EN 61095.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| Product or component type | Overvoltage protection auxiliary (2 circuits) |
| Device short name | iACTp |
| [Uc] control circuit voltage | 220...240 V AC 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Hold-in power consumption in VA | 3 VA |
| Mounting mode | Fixed, on the left of CT |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 81 mm |
| Width | 18 mm |
| Depth | 60 mm |
| Colour | White |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 4 kV |
| [Ui] rated insulation voltage | 440 V |
| Standards | IEC/EN 61095 |
| Connections - terminals | Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 1.5â¦2.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 1.5â¦2.5 mm² flexible with ferrule Control circuit: yellow clips |
| Wire stripping length | 9 mm |
| Tightening torque | 0.8 N.m |
| Range compatibility | Acti9 iCT |
| Market segment | Small commercial Residential |
| Compatibility code | IACTp |

This Acti 9 iACT24 is reliable control and indication auxiliary. It has 1 normally open signal contact. Control voltage is 24VDC and 230V AC. Mounting is performed on the left of Acti9 iCT contactors with operational current less than or equal to 25A. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. Mechanical endurance goes up to 250000 cycles. This product is compliant with IEC/EN 60947-5-1.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| Product or component type | Control and indication auxiliary |
| Device short name | iACT24 |
| Signal contacts composition | 1 NO |
| Signalling circuit voltage | 24 V DC: - 20...20 % 0.002...0.1 A |
| [Uc] control circuit voltage | 230 V AC 50/60 Hz maintained >= 200 ms 24 V DC falling edge 24 V DC rising edge |
| control type | Remote control |
| [Us] rated supply voltage | 230 V AC at 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Mounting mode | Fixed, on the left of CT |
| Mounting support | DIN rail |
| Comb busbar and distribution block compatibility | Bottom: YES Top: NO |
| 9 mm pitches | 2 |
| Height | 81 mm |
| Width | 18 mm |
| Depth | 68 mm |
| Colour | White |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 4 kV |
| [Ui] rated insulation voltage | 440 V |
| Immunity to microbreaks | 10 ms |
| Undervoltage behaviour | No opening if loss of 24 V DC |
| Standards | IEC 60947-1 annex S |
| Quality labels | CE |
| Electrical durability | 250000 cycles conforming to IEC 60947-5-1 |
| Connections - terminals | Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid Auxiliary supply: tunnel type terminals 2 cable(s) 2.5 mm² flexible Auxiliary supply: tunnel type terminals 2 cable(s) 1.5 mm² rigid Control circuit: spring-loaded terminal Ti24 2 cable(s) 0.25â¦0.75 mm² flexible Control circuit: spring-loaded terminal Ti24 1 cable(s) 0.5â¦1.5 mm² flexible |
| Wire stripping length | Control circuit: 10 mm for bottom connection Auxiliary supply: 10 mm for bottom connection Control circuit: 10 mm for top connection |
| Tightening torque | Control circuit: 1 N.m bottom Auxiliary supply: 1 N.m bottom |
| Product compatibility | ICT 230/240 V 50 Hz With PLC ICT 220 V 50 Hz Acti 9 Smartlink ICT 220/240 V 50 Hz |
| Market segment | Residential Small commercial |
| Compatibility code | IACT24 |

This Acti 9 iACTc is modular and reliable double control input auxiliary. Rated supply voltage is 24VAC to 48VAC and control voltage is 24VAC to 48VAC. Mounting is performed on the left of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is compatible only with all Acti9 iCT greater or equal than 25A. This auxiliary is used to control a contactor in impulse-type mode or to combine latched or impulse-type control orders. This product is compliant with IEC/EN 61095.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Acti9 |
| Product or component type | Double control input auxiliary |
| Device short name | iACTc |
| [Uc] control circuit voltage | 24...48 V AC 50/60 Hz impulse 250 ms 24...48 V AC 50/60 Hz maintained |
| [Us] rated supply voltage | 24...48 V AC at 50/60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Maximum output current | 0.2 A holding 2 A inrush |
| Hold-in power consumption in VA | 3 VA |
| Mounting mode | Fixed, on the left of CT |
| Mounting support | DIN rail |
| 9 mm pitches | 2 |
| Height | 81 mm |
| Width | 18 mm |
| Depth | 60 mm |
| Colour | White |
| Overvoltage category | III |
| [Uimp] rated impulse withstand voltage | 4 kV |
| [Ui] rated insulation voltage | 440 V |
| Standards | IEC/EN 61095 |
| Connections - terminals | Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 1.5â¦2.5 mm² rigid Control circuit: tunnel type terminals 1 cable(s) 1.5â¦2.5 mm² flexible with ferrule Control circuit: yellow clips |
| Wire stripping length | 9 mm |
| Tightening torque | 0.8 N.m |
| Range compatibility | Acti9 iCT |
| Market segment | Small commercial Residential |
| Compatibility code | IACTc |

This Acti9 iCT is a modular contactor. It is a 4P remote control device with 4 normally open contacts. The rated current is 25A for AC-7a and 8.5A for AC-7b. The Ue rated operational voltage is 400VAC. The Uc control voltage is 24VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 4 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 81mm x (H) 36mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.
Main
| Characteristic | Value(s) |
|---|---|
| range of product | Acti9 |
| product name | Acti9 iCT |
| Product or component type | Contactor |
| Device short name | iCT |
| Device application | Motor-heating-lighting |
| Poles | 4P |
| [Ie] rated operational current | 25 A AC-7A 8.5 A AC-7B |
| Pole contact composition | 4 NO |
| Network type | AC |
| control type | Remote control |
| [Uc] control circuit voltage | 24 V AC 50 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| Network frequency | 50 Hz |
| [Ue] rated operational voltage | 400 V AC 50 Hz |
| Maximum power | 1.6 W at 400 V AC |
| [Ui] rated insulation voltage | 500 V AC 50/60 Hz |
| [Uimp] rated impulse withstand voltage | 4 kV |
| Control signal type | Maintained |
| Switching frequency | 100 switching operations/day |
| Local signalling | Action indicator |
| Hold-in power consumption in VA | 4.6 VA |
| Inrush power in VA | 34 VA |
| Mounting mode | Clip-on |
| Mounting support | 35 mm symmetrical DIN rail |
| 9 mm pitches | 4 |
| Height | 81 mm |
| Width | 36 mm |
| Depth | 60 mm |
| Colour | White |
| Mechanical durability | 1000000 cycles |
| Electrical durability | 100000 cycles IEC/EN 61095 25 A 50 Hz AC-7A 30000 cycles IEC/EN 61095 8.5 A 50 Hz AC-7B 30000 cycles IEC/EN 61095 50 Hz AC-7C 100000 cycles EN/IEC 60947-4-1 50 Hz AC-1 30000 cycles EN/IEC 60947-4-1 50 Hz AC-3 30000 cycles EN/IEC 60947-4-1 50 Hz AC-5a 30000 cycles EN/IEC 60947-4-1 50 Hz AC-5b |
| Connections - terminals | Control circuit: tunnel type terminals2 cable(s) 1.5 mm² rigid Power circuit: tunnel type terminals1 cable(s) 1â¦4 mm² flexible Power circuit: tunnel type terminals1 cable(s) 1.5â¦6 mm² rigid Control circuit: tunnel type terminals1 cable(s) 1.5â¦2.5 mm² rigid Control circuit: tunnel type terminals2 cable(s) 1.5â¦2.5 mm² flexible |
| Tightening torque | Control circuit: 0.8 N.m Power circuit: 0.8 N.m |
| Product compatibility | IACTp IACTs IACTc IATEt |
| Compatibility code | ICT |
| Market segment | Small commercial Residential |