Schneider
Schneider

Schneider

25001 products

Showing 1129 - 1152 of 25001 products

Showing 1129 - 1152 of 25001 products
View
A9C15404 Schneider Electric
Schneider A9C15404 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iATLc is reliable centralized control auxiliary. Control voltage is between 24VAC and 240VAC. Mounting is performed on the right of iTL impulse relay with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is associated with iTL impulse relays to allow centralized control of a group of impulse relays. This product is compliant with EN/IEC 60669-2-2.

Main

Characteristic Value(s)
range of product Acti9
Device short name iATLc
Product or component type Centralized control auxiliary
[Uc] control circuit voltage 24...240 V AC 50/60 Hz impulse

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 440 V
[Uimp] rated impulse withstand voltage 4 kV
Remote control type 2 entries for switch
Mounting mode Fixed, on right side of TL
Mounting support DIN rail
9 mm pitches 1
Height 81 mm
Width 9 mm
Depth 69 mm
Colour White
Connections - terminals Tunnel type terminals0.5…4 mm² - rigid
Tunnel type terminals0.5…4 mm² - rigid - with cable end
Tunnel type terminals1…4 mm² - flexible
Tunnel type terminals1…4 mm² - flexible - with cable end
Wire stripping length 11 mm
Tightening torque 1 N.m
Range compatibility Acti9 iTL
Acti9 iTLi
Acti9 iTLs
Product compatibility ITL (32 A)
ITL (16 A)
A9C15405 Schneider Electric
Schneider A9C15405 Schneider Electric
Sale price$0.00
Sold Out

Acti 9 remote indication iATLs

A9C15409 Schneider Electric
Schneider A9C15409 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iATLc+s is reliable centralized control and remote indication auxiliary. It has 1 changeover contact, and it operates with 24VAC to 240VAC control voltage. Mounting is performed on the right of iTL impulse relay with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is associated with iTL impulse relays allow centralized control of a group of impulse relays. This product is compliant with EN/IEC 60669-2-2.

Main

Characteristic Value(s)
range of product Acti9
Device short name iATLc+s
Product or component type Centralized control and remote indication auxiliary
Signal contacts composition 1 C/O
Signalling circuit voltage 24 V AC/DC: 10 mA
12...240 V AC: 50/60 Hz 6 A
12...24 V DC: 6 A
15...240 V AC: 50/60 Hz 2 A
13...24 V DC: 2 A
[Uc] control circuit voltage 24...240 V AC 50/60 Hz

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 440 V
[Uimp] rated impulse withstand voltage 4 kV
Mounting mode Fixed, on right side of TL
Mounting support DIN rail
9 mm pitches 2
Height 86 mm
Width 18 mm
Depth 71 mm
Colour White
Connections - terminals Tunnel type terminals0.5…4 mm² - rigid
Tunnel type terminals0.5…4 mm² - rigid - with cable end
Tunnel type terminals1…4 mm² - flexible
Tunnel type terminals1…4 mm² - flexible - with cable end
Wire stripping length 11 mm
Tightening torque 1 N.m
Range compatibility Acti9 iTL
Acti9 iTLi
Acti9 iTLs
Product compatibility ITL (32 A)
ITL (16 A)
A9C15410 Schneider Electric
Schneider A9C15410 Schneider Electric
Sale price$0.00
Sold Out

Acti 9 multi-level centralized control iATLc+c

A9C15412 Schneider Electric
Schneider A9C15412 Schneider Electric
Sale price$0.00
Sold Out

Acti 9 step by stel control iATL4

A9C15413 Schneider Electric
Schneider A9C15413 Schneider Electric
Sale price$0.00
Sold Out

Acti 9 control by illuminated push-buttons iATLz

A9C15414 Schneider Electric
Schneider A9C15414 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iATLm is reliable latched control auxiliary. Is operates with 12VAC to 240VAC control voltage. Mounting is performed on the right of iTL impulse relay with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is associated with iTL impulse relays to allow latched type control orders from a changeover contact. This product is compliant with EN/IEC 60669-2-2.

Main

Characteristic Value(s)
range of product Acti9
Device short name iATLm
Product or component type Latched control auxiliary
[Uc] control circuit voltage 12...240 V AC 50/60 Hz maintained

Complementary

Characteristic Value(s)
[Ui] rated insulation voltage 440 V
[Uimp] rated impulse withstand voltage 4 kV
Remote control type 2 entries for switch
Mounting mode Fixed, on right side of TL
Mounting support DIN rail
9 mm pitches 1
Height 81 mm
Width 9 mm
Depth 69 mm
Colour White
Connections - terminals Tunnel type terminals0.5…4 mm² - rigid
Tunnel type terminals0.5…4 mm² - rigid - with cable end
Tunnel type terminals1…4 mm² - flexible
Tunnel type terminals1…4 mm² - flexible - with cable end
Wire stripping length 11 mm
Tightening torque 1 N.m
Range compatibility Acti9 iTL
Acti9 iTLi
Acti9 iTLs
Product compatibility ITL (16 A)
ITL (32 A)
A9C15415 Schneider Electric
Schneider A9C15415 Schneider Electric
Sale price$0.00
Sold Out

Yellow clips accessories (set of 10 clips)

A9C15419 Schneider Electric
Schneider A9C15419 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iATEt is reliable time delay auxiliary. It operates from 24VAC to 240VAC and 24VDC to 110VDC control voltage. Mounting is performed on the left of iTL impulse relay or iCT contactor with yellow clips. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. 5 time delays are possible, 1 for iTL and 4 for iCT. This product is compliant with EN/IEC 60669-2-2.

Main

Characteristic Value(s)
Range Acti9
Product or component type Time delay auxiliary
Device short name iATEt
[Uc] control circuit voltage 24...110 V DC impulse
24...240 V AC 50/60 Hz maintained

Complementary

Characteristic Value(s)
Type of setting Time delay configuration
Time delay range 2 s...10 min
2 s...10 h
6...60 s
1...10 s
6 s...1 h
Maximum output current 0.2 A holding
3 A inrush
Hold-in power consumption in VA 5 VA
Mounting mode Fixed, on the left of TL or CT
Mounting support DIN rail
9 mm pitches 2
Height 81 mm
Width 18 mm
Depth 60 mm
Colour White
Overvoltage category III
[Uimp] rated impulse withstand voltage 4 kV
[Ui] rated insulation voltage 440 V
Standards EN/IEC 60669-2-2
Connections - terminals Output connection: yellow clips
Input connection: tunnel type terminals 2 cable(s) 2.5 mm² flexible
Input connection: tunnel type terminals 2 cable(s) 1.5 mm² rigid
Wire stripping length 9 mm
Tightening torque 0.8 N.m
Range compatibility Acti9 iCT
Acti9 iTL
Market segment Small commercial
Residential
Compatibility code IATEt
A9C15424 Schneider Electric
Schneider A9C15424 Schneider Electric
Sale price$0.00
Sold Out

Acti 9 iATL24 control and remote indication with Ti24 connector

A9C15509 Schneider Electric
Schneider A9C15509 Schneider Electric
Sale price$0.00
Sold Out

impulse relay, Acti9 TL40, 2P, 1NO, 16 A, 230 V AC, 50 Hz

A9C15906 Schneider Electric
Schneider A9C15906 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 CDSc is single-phase load-shedder for 1 pole installation with 1 relay per phase. When the consumption exceeds the selected threshold, it temporarily cuts off the power supply to non-priority circuits. It increases the number of loads without modifying the installed power. The load-shedding and restoration in cascading configuration of 4 non-priority circuits via 4 relays with time-delayed action. This device reduces the installed power and prevents nuisance tripping of the upstream circuit breaker. The Iu Rated current is 5A to 90A. The Rated current (control contacts) is 1A. The Ui insulation voltage is 230VAC. The Ue operating voltage is 230VAC +/- 10%. The operating frequency is 50Hz or 60Hz. The power consumption is 12VA. The active power is 20kW maximum. The connection is done with rigid coper cables 10mm² to 50mm² or flexible or with ferrule copper cables 10mm² to 35mm². The dimensions are (W) 144mm x (H) 77mm x (D) 60mm. The width in 9mm pitches is 16. The weight is 600g. The degree of protection is IP20 and IP40 for a device in modular enclosure. The Operating temperature is -5°C to +50°C. The Storage temperature is -40°C to +70°C. It complies with NF C 61.750 and EN 500.81.1 standards.

Main

Characteristic Value(s)
range of product Acti9
product name Acti9 CDS
Product or component type Load-shedding contactor
Device short name CDSc
Number of channels 4
Control and monitoring type Cascade
Poles description 1P

Complementary

Characteristic Value(s)
Setting 40
10
90
30
5
45
75
15
50
20
25
60
Power consumption in VA 4 VA
[Ue] rated operational voltage 230 V AC - 15...10 % at 50/60 Hz
Rated current 15 A for non-priority circuit
Adjustable from 5 to 90 A for priority circuit
Local signalling Load-shedding indication: 4 LEDs (yellow)
Mounting support 35 mm symmetrical DIN rail
Panel mounting
Wall mounted
9 mm pitches 16
Connections - terminals Non-priority circuit: screw terminal2.5…10 mm² flexible
Non-priority circuit: screw terminal2.5…10 mm² rigid
Priority circuit: screw terminal10…35 mm² flexible
Priority circuit: screw terminal10…50 mm² rigid
IP degree of protection IP20 conforming to IEC 60529
Height 77 mm
Width 144 mm
Depth 60 mm
Product weight 0.6 kg
Colour White (RAL 9003)
Tightening torque Non-priority circuit: 2 N.m
Priority circuit: 3.5 N.m
Wire stripping length 12 mm
13 mm
A9C15908 Schneider Electric
Schneider A9C15908 Schneider Electric
Sale price$0.00
Sold Out

CDS - single phase load-shedding contactor - 2 channels

A9C15913 Schneider Electric
Schneider A9C15913 Schneider Electric
Sale price $573.75
Only 2 units left

CDS - three phase load-shedding contactor - 1 channel per phase

A9C15914 Schneider Electric
Schneider A9C15914 Schneider Electric
Sale price$0.00
Sold Out

Remote indication auxiliary, Acti9 iACTs, 1 NO + 1 NC

A9C15915 Schneider Electric
Schneider A9C15915 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iACTs is reliable remote indication auxiliary. It has 1 changeover contact, it operates from 24VAC to 240VAC and 24VDC to 130VDC. Mounting is performed on the right of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is compatible with all Acti9 iCT Contactors. This product helps reporting the status of a contactor and is especially required in a connected environment. This product is compliant with EN 60947-5.

Main

Characteristic Value(s)
Range of product ICT
Range Acti9
Device short name iACTs
Product or component type Remote indication auxiliary
Signal contacts composition 1 C/O

Complementary

Characteristic Value(s)
Signalling circuit voltage 24 V AC/DC: 10 mA
230 V AC: 50/60 Hz 5 A
230 V AC: 50/60 Hz 2 A
130 V DC: 1 A
[Uc] control circuit voltage 24...240 V AC 50/60 Hz
24...130 V DC
Range compatibility Acti9 iCT
[Ui] rated insulation voltage 440 V
[Uimp] rated impulse withstand voltage 4 kV
Mounting mode Fixed, on the right of CT
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 1
Height 81 mm
Width 9 mm
Depth 68 mm
Colour White
Auxiliary connection terminal Tunnel type terminals 2 cable(s) flexible 2.5 mm²
Tunnel type terminals 2 cable(s) rigid 1.5 mm²
Tunnel type terminals 1 cable(s) rigid 1.5…2.5 mm²
Tunnel type terminals 1 cable(s) flexible 1.5…2.5 mm²
Wire stripping length 9 mm
Tightening torque 0.8 N.m
Product compatibility ICT
Market segment Residential
Small commercial
Compatibility code IACTs
A9C15916 Schneider Electric
Schneider A9C15916 Schneider Electric
Sale price$0.00
Sold Out

Remote indication auxiliary, Acti9 iACTs, 2 NO

A9C15919 Schneider Electric
Schneider A9C15919 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iACTp is modular and reliable overvoltage protection auxiliary (2 circuits). It operates from 12VAC to 48VAC, at a frequency of 50/60 Hz. Mounting is performed on the left of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. it si compatible only with Acti9 iCT greater or equal than 25A. This auxiliary is an interference suppressor which limits overvoltage on the control circuit. This product is compliant with IEC/EN 61095.

Main

Characteristic Value(s)
Range Acti9
Product or component type Overvoltage protection auxiliary (2 circuits)
Device short name iACTp
[Uc] control circuit voltage 12...48 V AC 50/60 Hz

Complementary

Characteristic Value(s)
Type of setting Time delay configuration
Time delay range 1...36000 s
Hold-in power consumption in VA 3 VA
Mounting mode Fixed, on the left of CT
Mounting support DIN rail
9 mm pitches 2
Height 81 mm
Width 18 mm
Depth 60 mm
Colour White
Overvoltage category III
[Uimp] rated impulse withstand voltage 4 kV
[Ui] rated insulation voltage 440 V
Standards IEC/EN 61095
Connections - terminals Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible
Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 1.5…2.5 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 1.5…2.5 mm² flexible with ferrule
Control circuit: yellow clips
Wire stripping length 9 mm
Tightening torque 0.8 N.m
Range compatibility Acti9 iCT
Market segment Residential
Small commercial
Compatibility code IACTp
A9C15920 Schneider Electric
Schneider A9C15920 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iACTp is modular and reliable overvoltage protection auxiliary (2 circuits). It operates from 220VAC to 240VAC, at a frequency of 50/60 Hz. Mounting is performed on the left of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. it si compatible only with Acti9 iCT greater or equal than 25A. This auxiliary is an interference suppressor which limits overvoltage on the control circuit. This product is compliant with IEC/EN 61095.

Main

Characteristic Value(s)
Range Acti9
Product or component type Overvoltage protection auxiliary (2 circuits)
Device short name iACTp
[Uc] control circuit voltage 220...240 V AC 50/60 Hz

Complementary

Characteristic Value(s)
Hold-in power consumption in VA 3 VA
Mounting mode Fixed, on the left of CT
Mounting support DIN rail
9 mm pitches 2
Height 81 mm
Width 18 mm
Depth 60 mm
Colour White
Overvoltage category III
[Uimp] rated impulse withstand voltage 4 kV
[Ui] rated insulation voltage 440 V
Standards IEC/EN 61095
Connections - terminals Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible
Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 1.5…2.5 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 1.5…2.5 mm² flexible with ferrule
Control circuit: yellow clips
Wire stripping length 9 mm
Tightening torque 0.8 N.m
Range compatibility Acti9 iCT
Market segment Small commercial
Residential
Compatibility code IACTp
A9C15924 Schneider Electric
Schneider A9C15924 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iACT24 is reliable control and indication auxiliary. It has 1 normally open signal contact. Control voltage is 24VDC and 230V AC. Mounting is performed on the left of Acti9 iCT contactors with operational current less than or equal to 25A. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. Mechanical endurance goes up to 250000 cycles. This product is compliant with IEC/EN 60947-5-1.

Main

Characteristic Value(s)
Range Acti9
Product or component type Control and indication auxiliary
Device short name iACT24
Signal contacts composition 1 NO
Signalling circuit voltage 24 V DC: - 20...20 % 0.002...0.1 A
[Uc] control circuit voltage 230 V AC 50/60 Hz maintained >= 200 ms
24 V DC falling edge
24 V DC rising edge
control type Remote control
[Us] rated supply voltage 230 V AC at 50/60 Hz

Complementary

Characteristic Value(s)
Mounting mode Fixed, on the left of CT
Mounting support DIN rail
Comb busbar and distribution block compatibility Bottom: YES
Top: NO
9 mm pitches 2
Height 81 mm
Width 18 mm
Depth 68 mm
Colour White
Overvoltage category III
[Uimp] rated impulse withstand voltage 4 kV
[Ui] rated insulation voltage 440 V
Immunity to microbreaks 10 ms
Undervoltage behaviour No opening if loss of 24 V DC
Standards IEC 60947-1 annex S
Quality labels CE
Electrical durability 250000 cycles conforming to IEC 60947-5-1
Connections - terminals Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible
Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid
Auxiliary supply: tunnel type terminals 2 cable(s) 2.5 mm² flexible
Auxiliary supply: tunnel type terminals 2 cable(s) 1.5 mm² rigid
Control circuit: spring-loaded terminal Ti24 2 cable(s) 0.25…0.75 mm² flexible
Control circuit: spring-loaded terminal Ti24 1 cable(s) 0.5…1.5 mm² flexible
Wire stripping length Control circuit: 10 mm for bottom connection
Auxiliary supply: 10 mm for bottom connection
Control circuit: 10 mm for top connection
Tightening torque Control circuit: 1 N.m bottom
Auxiliary supply: 1 N.m bottom
Product compatibility ICT 230/240 V 50 Hz
With PLC
ICT 220 V 50 Hz
Acti 9 Smartlink
ICT 220/240 V 50 Hz
Market segment Residential
Small commercial
Compatibility code IACT24
A9C18308 Schneider Electric
Schneider A9C18308 Schneider Electric
Sale price$0.00
Sold Out

Acti 9 double control input auxiliary iACTc 230...240 V AC

A9C18309 Schneider Electric
Schneider A9C18309 Schneider Electric
Sale price$0.00
Sold Out

This Acti 9 iACTc is modular and reliable double control input auxiliary. Rated supply voltage is 24VAC to 48VAC and control voltage is 24VAC to 48VAC. Mounting is performed on the left of Acti9 iCT contactors. The degree of protection is IP20 and IP40 in an enclosure. It is DIN rail mountable. It is compatible only with all Acti9 iCT greater or equal than 25A. This auxiliary is used to control a contactor in impulse-type mode or to combine latched or impulse-type control orders. This product is compliant with IEC/EN 61095.

Main

Characteristic Value(s)
Range Acti9
Product or component type Double control input auxiliary
Device short name iACTc
[Uc] control circuit voltage 24...48 V AC 50/60 Hz impulse 250 ms
24...48 V AC 50/60 Hz maintained
[Us] rated supply voltage 24...48 V AC at 50/60 Hz

Complementary

Characteristic Value(s)
Maximum output current 0.2 A holding
2 A inrush
Hold-in power consumption in VA 3 VA
Mounting mode Fixed, on the left of CT
Mounting support DIN rail
9 mm pitches 2
Height 81 mm
Width 18 mm
Depth 60 mm
Colour White
Overvoltage category III
[Uimp] rated impulse withstand voltage 4 kV
[Ui] rated insulation voltage 440 V
Standards IEC/EN 61095
Connections - terminals Control circuit: tunnel type terminals 2 cable(s) 2.5 mm² flexible
Control circuit: tunnel type terminals 2 cable(s) 1.5 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 1.5…2.5 mm² rigid
Control circuit: tunnel type terminals 1 cable(s) 1.5…2.5 mm² flexible with ferrule
Control circuit: yellow clips
Wire stripping length 9 mm
Tightening torque 0.8 N.m
Range compatibility Acti9 iCT
Market segment Small commercial
Residential
Compatibility code IACTc
A9C20132 Schneider Electric
Schneider A9C20132 Schneider Electric
Sale price$0.00
Sold Out

iCT 25A 2NO 24V 50Hz contactor

A9C20134 Schneider Electric
Schneider A9C20134 Schneider Electric
Sale price$0.00
Sold Out

This Acti9 iCT is a modular contactor. It is a 4P remote control device with 4 normally open contacts. The rated current is 25A for AC-7a and 8.5A for AC-7b. The Ue rated operational voltage is 400VAC. The Uc control voltage is 24VAC. This device could be used for control circuits. This device could be used for remote switching lighting loads, small motors (fans, mixers) or HVAC system applications. It is compatible with all the Acti9 control auxiliaries, for lighting, heating & ventilation control applications. This product is compliant with IEC/EN 61095. Electrical endurance goes up to 100000 cycles for AC-7A or AC-1, 30000 cycles for AC-7C, AC-7B, AC-3, AC-5A or AC-5B The maximum switching operations is 6 per minute. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 4kV. Pollution degree is 2. It is DIN rail mountable. Its width is 4 pitches of 9mm. The product color is white (RAL9003). The dimensions are (W) 81mm x (H) 36mm x (D) 60mm. According to IEC 60529 standard, the degree of protection is IP20 and IP40 in enclosure. The operating temperature is from -5°C to 60 °C. The storage temperature is from -40°C to 70°C.

Main

Characteristic Value(s)
range of product Acti9
product name Acti9 iCT
Product or component type Contactor
Device short name iCT
Device application Motor-heating-lighting
Poles 4P
[Ie] rated operational current 25 A AC-7A
8.5 A AC-7B
Pole contact composition 4 NO
Network type AC
control type Remote control
[Uc] control circuit voltage 24 V AC 50 Hz

Complementary

Characteristic Value(s)
Network frequency 50 Hz
[Ue] rated operational voltage 400 V AC 50 Hz
Maximum power 1.6 W at 400 V AC
[Ui] rated insulation voltage 500 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage 4 kV
Control signal type Maintained
Switching frequency 100 switching operations/day
Local signalling Action indicator
Hold-in power consumption in VA 4.6 VA
Inrush power in VA 34 VA
Mounting mode Clip-on
Mounting support 35 mm symmetrical DIN rail
9 mm pitches 4
Height 81 mm
Width 36 mm
Depth 60 mm
Colour White
Mechanical durability 1000000 cycles
Electrical durability 100000 cycles IEC/EN 61095 25 A 50 Hz AC-7A
30000 cycles IEC/EN 61095 8.5 A 50 Hz AC-7B
30000 cycles IEC/EN 61095 50 Hz AC-7C
100000 cycles EN/IEC 60947-4-1 50 Hz AC-1
30000 cycles EN/IEC 60947-4-1 50 Hz AC-3
30000 cycles EN/IEC 60947-4-1 50 Hz AC-5a
30000 cycles EN/IEC 60947-4-1 50 Hz AC-5b
Connections - terminals Control circuit: tunnel type terminals2 cable(s) 1.5 mm² rigid
Power circuit: tunnel type terminals1 cable(s) 1…4 mm² flexible
Power circuit: tunnel type terminals1 cable(s) 1.5…6 mm² rigid
Control circuit: tunnel type terminals1 cable(s) 1.5…2.5 mm² rigid
Control circuit: tunnel type terminals2 cable(s) 1.5…2.5 mm² flexible
Tightening torque Control circuit: 0.8 N.m
Power circuit: 0.8 N.m
Product compatibility IACTp
IACTs
IACTc
IATEt
Compatibility code ICT
Market segment Small commercial
Residential