This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has additional solid-state output for communication with PLCs about safety status of your process.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety module |
| Safety module name | XPSAC |
| Safety module application | For emergency stop and switch monitoring |
| Function of module | Emergency stop Switch monitoring |
| Safety level | Can reach PL e/category 4 ISO 13849-1 Can reach SILCL 3 IEC 62061 |
| Safety reliability data | MTTFd = 210.4 years ISO 13849-1 DC > 99 % ISO 13849-1 PFHd = 3.56E-9 1/h IEC 62061 |
| Type of start | Unmonitored |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Output type | Relay instantaneous opening, 3 NO, volt-free |
| Number of additional circuits | 1 solid state output |
| [Us] Rated Supply Voltage | 230 V AC - 15...10 % |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Maximum power consumption in VA | 6 VA AC |
| [Uc] control circuit voltage | 230 V |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 6 A per relay relay output |
| [Ith] conventional free air thermal current | 10.5 A |
| Associated fuse rating | 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 16 V relay output |
| Maximum response time on input open | 100 ms |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local signalling | 2 LEDs |
| Current consumption | 25 mA 230 V AC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.46 lb(US) (0.21 kg) |

This XPSAFL safety module monitors emergency shutdown pushbuttons, limit switches and light curtains. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1 and electrical monitoring of switches activated by protection devices conforming to standard EN/ISO 14119. And for monitoring of type 4 light curtains conforming to EN 61496-1 that have solid-state safety outputs, with a performance lLevel PL e/Category 4 in accordance with EN/ISO 13849-1. 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It is compatible with emergency push buttons, limit switches and safety light curtains, the 3 most common safety sensors in the industry.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety module |
| Safety module name | XPSAF |
| Safety module application | For emergency stop, switch and safety light curtain monitoring |
| Function of module | Monitoring of electro-sensitive protection equipment (ESPE) Monitoring of a movable guard Emergency stop with 2 NC contacts monitoring 2-channel wiring Emergency stop monitoring 1-channel wiring Multiple emergency stop monitoring 2-channel wiring |
| Safety level | Can reach PL e/category 4 ISO 13849-1 Can reach SILCL 3 IEC 62061 |
| Safety reliability data | DC > 99 % ISO 13849-1 MTTFd = 172.1 years ISO 13849-1 PFHd = 5.61E-9 1/h IEC 62061 |
| Type of start | Unmonitored |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid with cable end, with double bezel Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Output type | Relay instantaneous opening, 3 NO, volt-free |
| Number of additional circuits | 0 |
| [Us] Rated Supply Voltage | 24 V AC - 15...10 % 24 V DC - 15...10 % |
Complementary
| Characteristic | Value(s) |
|---|---|
| Synchronisation time between inputs | Unlimited |
| Supply frequency | 50/60 Hz |
| Maximum power consumption in VA | 5 VA AC |
| Input protection type | Internal, electronic |
| [Uc] control circuit voltage | 24 V |
| Maximum line resistance | 90 Ohm |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 6 A per relay relay output |
| [Ith] conventional free air thermal current | 18 A |
| Associated fuse rating | 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Maximum response time on input open | 40 ms |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local signalling | 3 LEDs |
| Current consumption | 30 mA 24 V AC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.55 lb(US) (0.25 kg) |

This XPSAK safety module monitors emergency shutdown pushbuttons, limit switches, light curtains and safety mats/edges. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It can also be used for electrical monitoring of switches activated by protection devices, with optional selection of synchronisation time between signals, monitoring of 4-wire sensing mats or edges. And monitoring of type 4 light curtains conforming to EN/IEC 61496-1 which have solid-state safety outputs with test function (light curtains XUSL). 24V AC/DC supply allows direct supply via an auxiliary transformer, like ABT7 or ABL6, allowing saving at installation time. It is compatible with emergency push buttons, limit switches, safety light curtains and safety mats/edges, the 4 most common safety sensors in the industry. It has removable terminals for easier and better control wires tightening, thus improving installation reliability. It has additional solid-state output for communication with PLCs about safety status of your process.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety module |
| Safety module name | XPSAK |
| Safety module application | For emergency stop, switch, sensing mat/edges or safety light curtain monitoring |
| Function of module | Monitoring of a movable guard associated with 2 switches and automatic start Monitoring of electro-sensitive protection equipment (ESPE) Sensing mat and edges monitoring Emergency stop monitoring 1-channel wiring Emergency stop with 2 NC contacts monitoring 2-channel wiring Multiple emergency stop monitoring 2-channel wiring Proximity sensor monitoring Monitoring of a movable guard |
| Safety level | Can reach PL e/category 4 ISO 13849-1 Can reach SILCL 3 IEC 62061 |
| Safety reliability data | DC > 99 % ISO 13849-1 MTTFd = 154.5 years ISO 13849-1 PFHd = 7.39E-9 1/h IEC 62061 |
| Type of start | Configurable |
| Connections - terminals | Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 1 x 0.2...1 x 2.5 mm² solid with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 1 x 0.25...1 x 2.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1 mm² solid with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.2...2 x 1.5 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.25...2 x 1 mm² flexible with cable end, with double bezel Captive screw clamp terminals, removable terminal block, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Output type | Relay instantaneous opening, 3 NO, volt-free |
| Number of additional circuits | 1 NC + 4 solid state outputs |
| [Us] Rated Supply Voltage | 24 V AC - 15...10 % 24 V DC - 15...10 % |
Complementary
| Characteristic | Value(s) |
|---|---|
| Synchronisation time between inputs | Unlimited (manual start) 2 or 4 s depending of wiring (automatic start) |
| Supply frequency | 50/60 Hz |
| Maximum power consumption in VA | 5 VA AC |
| Input protection type | Internal, electronic |
| [Uc] control circuit voltage | 24 V DC |
| Maximum line resistance | 28 Ohm |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 6 A per relay relay output |
| [Ith] conventional free air thermal current | 18 A |
| Associated fuse rating | 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Maximum response time on input open | 40 ms |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local signalling | 4 LEDs |
| Current consumption | 30 mA 24 V AC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.7 lb(US) (0.3 kg) |

This XPSBF safety module is for electrical monitoring of two-hand control stations. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for two-hand control stations, designed to protect operators from sustaining hands injury. It has additional solid-state output for communication with PLCs about safety status of your process.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety module |
| Safety module name | XPSBF |
| Safety module application | For electrical monitoring of two-hand control stations |
| Function of module | Monitoring two-hand control station and a foot switch |
| Safety level | Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061 |
| Safety reliability data | DC > 99 % EN/ISO 13849-1 MTTFd = 50.1 years EN/ISO 13849-1 PFHd = 1.3E-8 1/h EN/IEC 62061 |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Output type | Relay, 2 NO, volt-free |
| Number of additional circuits | 2 solid state outputs |
| [Us] Rated Supply Voltage | 24 V DC - 20...20 % |
Complementary
| Characteristic | Value(s) |
|---|---|
| Synchronisation time between inputs | 0.5 s |
| Power Consumption in W | 2.5 W |
| Input protection type | Internal, electronic |
| Number of Inputs | 1 NC + NO |
| Input compatibility | Two-hand control EN 574/ISO 13851-III C |
| [Uc] control circuit voltage | 24 V DC |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 20 mA 24 V solid state output circuit 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 4.2 A per relay relay output |
| [Ith] conventional free air thermal current | 8.4 A |
| Associated fuse rating | 4 A gG relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 17 V relay output |
| Maximum response time on input open | 20 ms |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local signalling | 3 LEDs |
| Current consumption | 8 mA 24 V DC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.33 lb(US) (0.15 kg) |

This XPSAC safety module monitors emergency shutdown pushbuttons and limit switches. It meets the requirements of Performance Level PL e/Category 4 conforming to standard EN/ISO 13849-1 and SILCL3 conforming to EN/IEC 61508 and EN/IEC 62061. It can be used for monitoring emergency stop circuits conforming to standards EN/ISO 13850 and EN/IEC 60204-1. It has additional solid-state output for communication with PLCs about safety status of your process.
Main
| Characteristic | Value(s) |
|---|---|
| Range of Product | Preventa Safety automation |
| Product or Component Type | Preventa safety module |
| Safety module name | XPSAC |
| Safety module application | For emergency stop and switch monitoring |
| Function of module | Emergency stop Switch monitoring |
| Safety level | Can reach PL e/category 4 EN/ISO 13849-1 Can reach SILCL 3 EN/IEC 62061 |
| Safety reliability data | MTTFd = 210.4 years EN/ISO 13849-1 DC > 99 % EN/ISO 13849-1 PFHd = 3.56E-9 1/h EN/IEC 62061 |
| Type of start | Unmonitored |
| Connections - terminals | Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² flexible without cable end Captive screw clamp terminals, 1 x 0.14...1 x 2.5 mm² solid without cable end Captive screw clamp terminals, 1 x 0.25...1 x 1.5 mm² flexible with cable end, with bezel Captive screw clamp terminals, 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² flexible without cable end Captive screw clamp terminals, 2 x 0.14...2 x 0.75 mm² solid without cable end Captive screw clamp terminals, 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel Captive screw clamp terminals, 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel |
| Output type | Relay instantaneous opening, 3 NO, volt-free |
| Number of additional circuits | 1 solid state output |
| [Us] Rated Supply Voltage | 48 V AC - 15...10 % |
Complementary
| Characteristic | Value(s) |
|---|---|
| Supply frequency | 50/60 Hz |
| Maximum power consumption in VA | 6 VA AC |
| [Uc] control circuit voltage | 48 V |
| Breaking capacity | 180 VA holding AC-15 C300 relay output 1800 VA inrush AC-15 C300 relay output |
| Breaking capacity | 1.5 A 24 V DC-13)50 ms relay output |
| Output thermal current | 6 A per relay relay output |
| [Ith] conventional free air thermal current | 10.5 A |
| Associated fuse rating | 4 A gG or gL relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 6 A fast blow relay output EN/IEC 60947-5-1, DIN VDE 0660 part 200 |
| Minimum output current | 10 mA relay output |
| Minimum output voltage | 16 V relay output |
| Maximum response time on input open | 100 ms |
| [Ui] rated insulation voltage | 300 V 2)IEC 60947-5-1 300 V 2)DIN VDE 0110 part 1 |
| [Uimp] rated impulse withstand voltage | 4 kV III IEC 60947-5-1 4 kV III DIN VDE 0110 part 1 |
| Local signalling | 2 LEDs |
| Current consumption | 100 mA 48 V AC on power supply |
| Mounting Support | 35 mm symmetrical DIN rail |
| Product Weight | 0.46 lb(US) (0.21 kg) |