Filters

Process Controls / Process Sensors

586 products

Showing 1 - 24 of 586 products

Showing 1 - 24 of 586 products
View
Keyence New Stock Image
Keyence FD-Q32C Keyence
Sale price $587.22
In stock, 12 units

Specifications

Model

FD-Q32C

Supported pipe diameter

1" (25 A), ø28 to ø37 (mm)
1 1/4" (32 A), ø37 to ø44 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1" (25 A): 200 L/min, 52.8 G/min
1 1/4" (32 A): 300 L/min, 79.3 G/min

Zero cut flow rate

5 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.1/ 1 (Default :1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

1/ 10/ 100/ 1000/ 10000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

130 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/POM/SUSXM7

Weight

Approx. 530 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

Keyence Stock Image
Keyence FD-XA1 Keyence
Sale price $507.85
In stock, 11 units

Specifications

Model

FD-XA1

Type

DIN rail type, main unit

Display method

Output indicator, 4-digit 7 segment display, OLED, Stability level display

Display refresh frequency

Instantaneous flow: approx. 5 times/second, Discharge amount/Accumulated flow approx. 30 times/second

Response time

50 ms/100 ms/500 ms/1 s/2.5 s/5 s/10 s/30 s/60 s (selectable, default: 500 ms)

Integration data storage interval

Written to the memory every 10 seconds

Memory back up

EEPROM (data storage period: more than 10 years, number of data rewritable times: 1 million times or more) *1

Detection mode

ch.1

Instantaneous flow rate mode/Area mode/Pulse output (+) mode/Integrated flow mode/Shot mode (selectable)

ch.2

Instantaneous flow rate mode/Area mode/Pulse output (-) mode/Shot mode/Error output mode/Bubble alert mode/Error + bubble alert mode (selectable)

Input/output

Output

NPN/PNP setting switch
Open collector output: 30 V or lower, main unit: 50 mA or lower/ch.*2/expansion unit: 20 mA or lower/ch., residual voltage: 2 V or lower

Analog output

4-20 mA/0-20 mA (selectable) load resistance: 500 ohms or lower

External input

Flow rate zero input/shot sampling input/integrated flow reset input/zero shift input (selectable)
Short circuit current: NPN 1 mA or lower/PNP 2 mA or lower, input time: 20 ms or longer

Network support

IO-Link*3

Unit expansion

Up to 7*4 per main unit

Protection circuit

Power supply reverse connection protection, power surge protection, output short circuit protection, output surge protection

Power supply

Power voltage

20 to 30 VDC including 10 % ripple (P-P) , Class 2

Power consumption

195 mA or lower (including the sensor head, excluding the load current)

Environmental resistance

Ambient temperature

-10 to +50 °C (No freezing) 14 to 122 °F

Relative humidity

35 % to 85 %RH (No condensation)

Vibration resistance

10 - 55 Hz, double amplitude 1.5 mm 0.06 ", 2 hours each for X,Y,Z direction

Shock resistance

100 m/s2 (approx. 10 G) 16 ms pulse, 1000 times each for X,Y,Z direction

Material

Main body case/front sheet: PC, Key top: POM, Cable: PVC

Weight

Approx. 210 g

*1 Internal data from full time recording can be read via USB (Ver.2.0) communication.
*2 20 mA or lower/ch when adding expansion units.
*3 IO-Link: Specification v1.1/COM2 (38.4 kbps) is supported. If the end of the cable needs to be an M12 connector when supporting IO-Link communication, connect an M12 conversion connector (OP-88296) to the cable.
*4 Refer to the Instruction Manual for the number of connected units to N-bus devices.

Keyence New Stock Image
Keyence FD-Q10C Keyence
Sale price $507.85
In stock, 11 units

Specifications

Model

FD-Q10C

Supported pipe diameter

1/4" (8 A), ø13 to ø16 (mm)
3/8" (10 A), ø16 to ø18 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1/4" (8 A): 20 L/min, 5.2 G/min
3/8" (10 A): 30 L/min, 7.9 G/min

Zero cut flow rate

1.0 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.01/0.1/1 (Default : 0.1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

0.1/ 1/ 10/ 100/ 1000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

100 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/SUSXM7

Weight

Approx. 340 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

Keyence New Stock Image
Keyence FT-H20 Keyence
Sale price $394.46
Only 9 units left

Specifications

Model

FT-H20

Type

Mid to low temperature, Mid-range

Rated temperature range

32 to 932°F (0 to 500°C) *1

Displayable temperature range

-58 to +968°F (-50 to +520°C)

Detecting distance

Unlimited *2

Measuring distance /
View diameter (example)

60/ø8.5 mm 2.36"/ø0.33"
120/ø6 mm 4.72"/ø0.24"
180/ø14.5 mm 7.09"/ø0.57"

Sight

2-point visible laser beam *3

Detecting element

Thermopile

Detecting wavelength

8 to 14 μm

Repeatability

±0.9°F (±0.5°C)

Emissivity (ε) correction

0.10 to 1.99 (0.01 step)

Environmental resistance

Ambient temperature

14 to 131°F (-10 to 55°C), No freezing

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions

Shock resistance

500 m/s2, 10 times in each direction of each axis (X, Y, Z), 60 times in total

Material

Case: Reinforced glass plastic,
Infrared collector lens: Germanium,
Laser transmitter: Polyarylate,
Cable: Vinyl chloride,
Mounting bracket: SUS304,
Mounting screw: Stainless steel

Accessory

Mounting bracket

Weight

Approx. 120g

*1 Repeatability is guaranteed within the rated temperature range.
*2 Place at a distance so that object appears 1.5 times larger than the view diameter.
*3 Visible semiconductor laser beam wavelength 655 nm, Class 1 Laser Product (IEC60825-1, FDA (CDRH) Part1040.10). The laser classification for FDA (CDRH) is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice.

Keyence New Stock Image
Keyence FW-H10R Keyence
Sale price $353.01
Only 5 units left

Specifications

Model

FW-H10R

Type

Long range

Detecting area

150 to 1000 mm 5.9" to 39.4"*1

Response speed

1,000 ms

Temperature characteristics

0.06% of F.S./°C*2

Indicator lamp

Operation indicator (orange) x1 (Turns on when the target is within the detecting range.)

Dimensions

M18 x P1, Length= 104 mm 4.09"

Environmental resistance

Enclosure rating

IP67

Ambient temperature

-25 to +70 °C -13 to 158 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis

Material

Brass-nickel plating, PBT, Polyurethane, Polyamide resin

Accessories

M18 nut: 2, Head cable: 2 m 6.6', Standard Mounting Bracket (FW-B01)

Weight

Approx. 106 g

*1 Less stable zones of approx. 2% of F.S. exist at both ends of the detecting range.
*2 The errors for the indicated value at 25°C 77°F.

Keyence Stock Image
Keyence FD-G50 Keyence
Sale price $1,695.78
Only 5 units left

Specifications

Model

FD-G50

Pipe size

DN (Diameter Nominal)

32 A, 40 A, 50 A

NPS (Nominal Pipe Size)

1 1/4", 1 1/2", 2"

Outer diameter of pipe

ø41 to 45 mm 1.61" to 1.77", ø47 to 51 mm 1.85" to 2.01", ø58 to 62 mm 2.28" to 2.44"

Pipe thickness

2.4 to 5.7 mm 0.09" to 0.22"

Supported pipe materials

Iron, steel, stainless steel

Supported fluids

Air, Nitrogen, other gases*1

Fluid temperature

0 to 60ºC 32 to 140 °F

Recommended pressure

0.4 MPa or greater (58 PSI or greater)

Rated velocity of flow range

Up to 15 m/s

Actual flow rate range (typical)

m3/h

Pipe size 32 A: 54.00
Pipe size 40 A: 72.00
Pipe size 50 A: 120.00

L/min

Pipe size 32 A: 900.0
Pipe size 40 A: 1200.0
Pipe size 50 A: 2000.0

CFM

Pipe size 32 A: 32.00
Pipe size 40 A: 42.00
Pipe size 50 A: 70.00

Standard flow rate range (typical) [CFM]

20°C 68°F 60 psi 0.41 MPa

Pipe size 32 A: 151.58
Pipe size 40 A: 198.95
Pipe size 50 A: 331.58

20°C 68°F 80 psi 0.55 MPa

Pipe size 32 A: 192.17
Pipe size 40 A: 252.22
Pipe size 50 A: 420.37

20°C 68°F 100 psi 0.69 MPa

Pipe size 32 A: 232.76
Pipe size 40 A: 305.49
Pipe size 50 A: 509.16

20°C 68°F 120 psi 0.83 MPa

Pipe size 32 A: 273.35
Pipe size 40 A: 358.77
Pipe size 50 A: 597.95

Display

QVGA 2.2" LCD color monitor

Display update cycle

Approx. 3 Hz

Display resolution

Instantaneous flow rate

0.01 m3/h, 0.1 L/min, 0.01 CFM

Consumption/leakage amount

0.01 m3, 1 L, 0.1 CF

Response time

1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable)

Measurement accuracy

Between 10 and 100% of F.S.

±2.0% of RD*2*3*4*5

Between 1 and 10% of F.S.

±1.0% of F.S.*2*3*4*5

Zero point error

±0.15% of F.S.*2*6

Static leakage repeatability

±1.0% of RD*4*7

Hysteresis

Variable

Flow units

CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min

I/O wiring connection port

M12 4-pin connector (male)

Detection mode (switchable)

ch.1

Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8

ch.2

Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8

Standard I/O (switchable)

Control output (ch.1/ch.2)

NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less

Analog output (ch.2)

4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less

External input (ch.2)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output

Analog input (for volume conversion)

M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less

Power supplied to pressure sensor

Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included)

Communication interface

USB

USB 2.0

Ethernet

Standard

IEEE 802.3u (100BASE-TX)

Transmission rate

100 Mbps

Cable

Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable

Connector

M12 connector (female, D-code)

Network function

Modbus TCP, EtherNet/IP™, IO-Link*9

Recording capacity

Consumption amount/ leakage amount

Approx. 5 years

Events

100

Power supply

Power voltage

20 to 30 VDC including 10% ripple (P-P), Class 2

Power consumption

350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded),
550 mA or less at 20 V, 490 mA or less at 24 V, 430 mA or less at 30 V (Maximum load current excluded) (analog output of the pressure sensor excluded)

Environmental resistance

Enclosure rating

IP65/67 (IEC 60529)*10

Ambient temperature

Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing)

Relative humidity

5 to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes

Shock resistance

100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis

Material

Display unit

Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating

Detection head

Body: PPS/SUS304, rear surface: rubber

Mounting/damping bracket

SUS304

Weight

Approx. 2.7 kg

*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas.
*2 This value is guaranteed by KEYENCE inspection facilities. Errors will be introduced by factors such as the type and status of the pipe and the type and temperature of the gas.
*3 This is the value when considering linearity + span error in a stable environment with a temperature of 25°C 77°F.
*4 Defined with stable velocity of flow distribution. Does not include pulsations and fluctuations in the velocity of flow distribution primarily attributable to the equipment.
*5 The linearity error characteristic due to the pipe is not included in this value.
*6 It is possible to reduce zero point errors by performing an origin adjustment.
*7 This is the value within the range where measurement accuracy is guaranteed.
*8 When Bi-directional is specified, the following functions cannot be used. The selection of the comparison view/leak ratio view/static leakage, the measurement/display of the leakage amount/integrated flow, the setting of the target value/warning set value, and money conversions. Also, the I/O settings are limited as shown below.
• ch.1: Pulse(+) mode
• ch.2: Pulse(-) mode, Error output mode, Integrated flow reset, Flow zero input, Origin adjustment input
*9 IO-Link: Compatible with specification v1.1/COM1 (4.8 kbps). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 The IP65/67 enclosure rating is lost when a USB connection is established.

keyence Stock Image
Keyence FD-XC8R3 Keyence
Sale price $544.53
Only 5 units left

Specifications

Model

FD-XC8R3

Supported diameter

Outer diameter of pipe: ø 8 0.31 "
Attachable range: ø 7.5 to 8.5 0.27 " to 0.33 "

Weight

Approx. 60 g

Keyence New Stock Image
Keyence FD-Q50C Keyence
Sale price $900.00
Only 9 units left

Specifications

Model

FD-Q50C

Supported pipe diameter

1 1/2" (40 A), ø44 to ø52 (mm)
2" (50 A), ø52 to ø64 (mm)

Supported pipe materials

Metal pipe/Resin pipe*1

Supported fluids

Various liquid [i.e. water (including DI), oils, chemicals, etc.]*1

Supported fluid temperature

0 to 85°C 32 to 185°F (No freezing on the pipe surface)*2

Maximum rated flow

1 1/2" (40 A): 400 L/min, 105.7 G/min
2" (50 A): 500 L/min, 132.1 G/min

Zero cut flow rate

25 L/min (Default)*3

Display method

Status indicator, output indicator, dual row display with 4-digit, 7 segment LED, stability level indicator

Display update cycle

Approx. 3 Hz

Display resolution

0.1/ 1 (Default :1) (L/min)

Response time

0.5 s / 1.0 s / 2.5 s / 5 s / 10 s / 30 s / 60 s

Protection circuit

Power supply reverse connection protection, power supply surge protection,
each output short-circuit protection, each output surge protection

Repeatability

0.5 s : ±2.0%, 1 s:±1.5%, 2.5 s : ±1.0%, 5 s : ±0.5%, 10 s : ±0.35%, 30 s : ±0.2%, 60 s : ±0.15% (/F.S.*4(Specific to selected response time))

Hysteresis

Variable

Integrated flow unit display

1/ 10/ 100/ 1000/ 10000 (Default : 1) (L)

Integrated flow data storage cycle

Save to memory every 10 seconds

Memory backup

EEPROM (Data storage length: 10 years or longer, Data read/write frequency: 1 million times or more)

Power I/O connector

M12 4-pin connector

Input/Output (Selectable)

Output (ch.1/ch.2)

Control output/ Pulse output/ Error output (Selectable, Default : ch.1 control output/ ch.2 not used),
NPN/PNP setting switchable,open collector output 30 V or less, max. 100 mA/ch., residual voltage 2.5 V or less*5

Analog output (ch.2)

4 to 20 mA / 0 to 20 mA (Selectable, Default: not used), load resistance 500 Ω or less*5

External input (ch.2)

Integrated flow reset input/ Flow rate zero input/ Origin adjustment input (Selectable, Default: not used),
short-circuit current 1.5 mA or less, input time 20 ms or more*5

Power supply

Power voltage

20 to 30 VDC , ripple (P-P) 10% max, Class2/LPS

Current consumption

130 mA or less (Load current excluded)*6

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient temperature

-10 to +60 °C 14 to 140 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

100 m/s2, 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Sensor main unit

PPS/PES/PBT/SUS303/SUS304/SUSXM7

Sensor surface

Rubber

Mounting bracket

SUS304/PA/POM/SUSXM7

Weight

Approx. 640 g (including mounting bracket)

*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable on certain non-standard pipes (i.e. lined pipes)
*2 Contact KEYENCE when the temperature of the pipe is greater than 85°C 185°F
*3 The zero cut flow rate can be changed in the settings. When using the unit with a low flow rate range, perform an origin adjustment when the fluid is not moving if you change the zero cut flow rate.
*4 This specification is valid when the flow velocity distribution is stable. This value does not take into account the effects of pulsation or fluctuations in flow velocity distribution due to facility factors. Convert the F.S. (full scale) listed in the table according to the rated flow range.
*5 IO-Link: Compatible with Specification v1.1 / COM2 (38.4 kbps) The setting file can be downloaded from the KEYENCE website. If using the unit in the environment where downloading the file is not possible via internet, contact your nearest KEYENCE office. IO-Link is either registered trademarks or trademarks of PROFIBUS Nutzerorganisation e.V. (PNO)
*6 When including the loads, please add 200 mA to this value.

keyence Stock Image
Keyence OP-88076 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88076

Overview

This is a relay connector cable with M12 on both ends. This connector cable is made of polyurethane (PUR), which has excellent oil resistance.

Applicable product

M12 connector sensor

Cable end

M12 straight connector - M12 straight connector

Length

5 m 16.40'

Material

Cable: Polyurethane (PUR)

Weight

Approx. 170 g 6.00 oz

keyence Stock Image
Keyence OP-88075 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88075

Overview

This is a relay connector cable with M12 on both ends. This connector cable is made of polyurethane (PUR), which has excellent oil resistance.

Applicable product

M12 connector sensor

Cable end

M12 straight connector - M12 straight connector

Length

2 m 6.56'

Material

Cable: Polyurethane (PUR)

Weight

Approx. 80 g 2.82 oz

keyence Stock Image
Keyence OP-88072 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-88072

Type

Cable for Separate Amplifier Models: For Amplifier (Connector Type)

Overview

This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance.

Applicable product

M8 connector sensor

Cable end

M8 - M12 straight

Length

5 m 16.4'

Material

Cable: Polyurethane (PUR)

Weight

Approx. 130 g 4.58 oz

keyence Stock Image
Keyence OP-88071 Keyence
Sale price $337.50
Only 1 unit left

Specifications

Model

OP-88071

Type

Cable for Separate Amplifier Models: For Amplifier (Connector Type)

Overview

This is a relay connector cable with M8 on one end and M12 on the other end. This connector cable is made of polyurethane (PUR), which has excellent oil resistance.

Applicable product

M8 connector sensor

Cable end

M8 - M12 straight

Length

2 m 6.6'

Material

Cable: Polyurethane (PUR)

Weight

Approx. 70 g 2.46 oz

keyence Stock Image
Keyence OP-87629 Keyence
Sale price $6,668.20
Only 1 unit left

Specifications

Model

OP-87629

Weight

Approx. 220 g

keyence Stock Image
Keyence OP-87628 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87626 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-87626

Type

Connector Cable M8 Straight 10m Standard

Cable end

M8 4-pin Straight

Length

10 m 32.8'

Material

Cable: PVC,
Connector: Zinc nickel plating

Weight

Approx. 260 g

Keyence Stock Image
Keyence OP-87625 Keyence
Sale price $181.31
Only 8 units left

Specifications

Model

OP-87625

Length

2 m 6.6'

Material

Cable: PVC
Connector: Zinc nickel plating

Weight

Approx. 70 g

keyence Stock Image
Keyence OP-85504 Keyence
Sale price$0.00
Sold Out

Specifications

Model

OP-85504

Overview

Connector cable with M12 on the both edges for connection.

Applicable product

M12 connector sensor

Cable end

M12 straight - M12 straight

Length

5 m 16.40'

Material

Cable: Polyvinyl chloride (PVC)

Weight

Approx. 130 g 4.58 oz

keyence Stock Image
Keyence FD-HY1 Keyence
Sale price$0.00
Sold Out

Specifications

Model

FD-HY1

Cable end

M12, 4pin

Material

PBT

Weight

Approx. 35 g

keyence Stock Image
Keyence FD-HCS2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

FD-HCS2

Length

2 m 6.6'

Material

PVC

Weight

Approx. 120 g

keyence Stock Image
Keyence FD-HCC2 Keyence
Sale price$0.00
Sold Out

Specifications

Model

FD-HCC2

Cable end

M12, 8-pin female to M12, 4-pin male

Length

2 m 6.6'

Material

PVC

Weight

Approx. 120 g

keyence Stock Image
Keyence FD-HCC0 Keyence
Sale price $337.49
Only 1 unit left

Specifications

Model

FD-HCC0

Cable end

M12, 8-pin female to M12, 4-pin male

Weight

Approx. 20 g

keyence Stock Image
Keyence FD-HCB2 Keyence
Sale price $1,062.74
Only 5 units left

Specifications

Model

FD-HCB2

Cable end

M12, 8-pin female - 6-core cable

Length

2 m 6.6'

Material

PVC

Weight

Approx. 110 g

keyence Stock Image
Keyence FD-HCB10 Keyence
Sale price $1,049.99
Only 2 units left

Specifications

Model

FD-HCB10

Cable end

M12, 8-pin female - 6-core cable

Length

10 m 32.8'

Material

PVC

Weight

Approx. 460 g

keyence Stock Image
Keyence FI-1000 Keyence
Sale price $577.91
Only 1 unit left

Specifications

Model

FI-1000

Display

QVGA 2.0 model: color LCD, status indicator light

Display update cycle

Approx. 10 times/second

Network support

IO-Link*1

Heat calculation function

Unit

MJ/h, kW, kBTU/h, GJ/h, MW, MBTU/h*2

Display resolution

Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*2

Pulse output increments (MJ)

0.02–999.99*2

Data accumulation

Accumulation period

Approx. 1 year

Data reading

USB2.0

Power I/O connector

M12 8-pin connector (male)

I/O (switchable)

Output (Ch1/2/3/4)

NPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/ch or less, residual voltage 2.5 V or less

Analog output (Ch1/2)

4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less

External input (Ch2/3)

Short circuit current: 1.5 mA or less; input time: 20 ms or more

Power supply

Power voltage

20–30 VDC, ripple (P-P) 10% included, Class 2/LPS

Current consumption

55 mA or less (display unit standalone, excluding load current)*3

Protection circuit

Protection against reverse power connection, power supply surges, output short circuits, and output surges

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)*4

Ambient temperature

–20°C to +50°C –4°F to +122°F (no freezing)

Relative humidity

35–85% RH (no condensation)

Vibration resistance

10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions

Shock resistance

100 m/s2 (approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z directions

Material

Body: PPS / PET / POM; Display window: PAR

Weight

Approx. 120 g 4.23 oz

*1 Supports IO-Link specification v.1.1/COM2 (38.4 kbps). Setting files can be downloaded from the KEYENCE website (www.keyence.com). IO-Link is a trademark or registered trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*2 Available when the separately sold flow meter FD-R Series and two temperature sensors are connected.
*3 455 mA or less including load. When connecting devices such as temperature sensors, please add on the current consumption of each sensor (to a maximum of 830 mA or less).
*4 When a USB connection is in use, IP65/67 compliance is impaired.