Overload Relays

930 products

Showing 121 - 144 of 930 products

Showing 121 - 144 of 930 products
View
Schneider New Stock Image
Schneider LRN357N Schneider
Sale price $98.75
Only 10 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV4PEM80B Schneider Electric
Schneider GV4PEM80B Schneider Electric
Sale price$0.00
Sold Out

TeSys GV motor circuit breaker, 3 poles (3P), 80A/690V, for protection of 3-phase motors 22-37kW@400V. Multifunction circuit breaker, it provides thermal magnetic protection and advanced motor protection, breaking capacity Icu 25kA@400V, start-stop control by toggle, connection by Everlink BTR screw terminals. Thermal protection adjustable by dials with a setting current Ir in range 40-80A and a selectable tripping class 10 or 20, magnetic protection at 17 In. Advanced protections are adjustable with a smartphone using wireless NFC and include short time delay protection Isd with a setting range 5-13 Ir, phase unbalance and loss protection, ground fault protection, locked rotor (jam), long start. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). It can be equiped externally with 1 or 2 auxiliary SDx modules in order to have alarming and fault differentiation. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX).

Main

Characteristic Value(s)
Range of Product TeSys GV4
Range TeSys Deca
Device short name GV4PEM
product name TeSys GV4
Product or Component Type Motor circuit breaker
Device Application Motor protection
Trip unit technology Electronic
Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Utilisation category Category A IEC 60947-2
AC-3 IEC 60947-4-1
Operating position Any position
Motor power kW 37 kW 400...415 V AC 50/60 Hz
45 kW 500 V AC 50/60 Hz
22 kW 400...415 V AC 50/60 Hz
30 kW 500 V AC 50/60 Hz
37 kW 660...690 V AC 50/60 Hz
45 kW 660...690 V AC 50/60 Hz
55 kW 660...690 V AC 50/60 Hz
30 kW 400...415 V AC 50/60 Hz
37 kW 500 V AC 50/60 Hz
Breaking capacity 50 kA Icu 220...240 V AC 50/60 Hz IEC 60947-2
25 kA Icu 380...415 V AC 50/60 Hz IEC 60947-2
20 kA Icu 440 V AC 50/60 Hz IEC 60947-2
10 kA Icu 500 V AC 50/60 Hz IEC 60947-2
35 kA 208Y/120 V AC 50/60 Hz UL 60947
35 kA 240 V AC 50/60 Hz UL 60947
18 kA 480Y/277 V AC 50/60 Hz UL 60947
14 kA 600Y/347 V AC 50/60 Hz UL 60947
Control Type Toggle
Line Rated Current 80 A
Magnetic tripping current 1360 A
[Ue] rated operational voltage 690 V AC 50/60 Hz IEC 60947-2
[Ui] rated insulation voltage 800 V AC 50/60 Hz IEC 60947-2
[Ith] conventional free air thermal current 115 A IEC 60947-4-1
[Uimp] rated impulse withstand voltage 8 kV IEC 60947-2
Power dissipation per pole 4.6 W
Mechanical durability 40000 cycles
Electrical durability 14000 cycles AC-3 440 V In/2
7000 cycles AC-3 440 V In
Maximum operating rate 25 cyc/h
Rated duty Continuous IEC 60947-4-1
Connections - terminals EverLink BTR screw connectors top) 1 0.002…0.1 in² (1.5…70 mm²) - solid
EverLink BTR screw connectors top) 1 0.002…0.08 in² (1.5…50 mm²) - flexible
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…95 mm²) - solid
EverLink BTR screw connectors bottom) 1 0.004…0.1 in² (2.5…70 mm²) - flexible
Tightening torque 79.7 lbf.in (9 N.m) 0.02…0.1 in² (16…95 mm²)
44.3 lbf.in (5 N.m) 0.002…0.02 in² (1.5…10 mm²)
Mechanical robustness Vibrations +/- 1 mm 2...13.2 Hz IEC 60068-2-6
Vibrations 0.7 gn 13.2...100 Hz IEC 60068-2-6
Shocks 15 gn 11 ms IEC 60068-2-27
Phase failure sensitivity Yes IEC 60947-4-1
Height 6.1 in (155 mm)
Width 3.2 in (81 mm)
Depth 4.6 in (116 mm)
Product Weight 3.20 lb(US) (1.45 kg)
color Gray RAL 7016)
Suitability for isolation Yes IEC 60947-1
Schneider New Stock Image
Schneider GV3P5037-50А Schneider
Sale price $159.63
Only 7 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

GV3P656 Schneider Electric
Schneider GV3P656 Schneider Electric
Sale price $359.99
Only 1 unit left

Motor circuit breaker, TeSys GV3, 3P, 48-65 A, thermal magnetic, lugs terminals

Schneider New Stock Image
Schneider LRD-32C Schneider
Sale price $92.09
Only 8 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GVAX386 Schneider Electric
Schneider GVAX386 Schneider Electric
Sale price$0.00
Sold Out

TeSys GV electrical trip, MN undervoltage release, 380-400V AC 60Hz, for motor circuit breakers GV2ME used in safety-related systems. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage is applied in the range 0.85-1.1 Uc. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC),

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Product or component type Safety undervoltage trip
Device short name GVAX

Complementary

Characteristic Value(s)
Range compatibility TeSys GV2ME
TeSys Deca
[Uc] control circuit voltage 380...400 V AC 60 Hz
Control circuit voltage limits 0.85...1.1 Un
[Ui] rated insulation voltage 690 V AC conforming to IEC 60947-1
600 V AC conforming to UL 60947-4-1
600 V AC conforming to CSA C22.2 No 60947-4-1
Threshold tripping voltage 0.7...0.35 Un
Inrush power in VA 12 VA AC
Inrush power in W 8 W
Hold-in power consumption in VA 3.5 VA AC
Hold-in power consumption in W 1.1 W
Operating time 10...15 ms conforming to IEC 60947-1
On-load factor 100 %
Connections - terminals Screw clamp terminals 1 cable(s) 1…2.5 mm²solid
Screw clamp terminals 2 cable(s) 1…2.5 mm²solid
Screw clamp terminals 1 cable(s) 0.75…2.5 mm²flexible without cable end
Screw clamp terminals 2 cable(s) 0.75…2.5 mm²flexible without cable end
Screw clamp terminals 1 cable(s) 0.75…1.5 mm²flexible with cable end
Screw clamp terminals 2 cable(s) 0.75…1.5 mm²flexible with cable end
Tightening torque < 1.4 N.m on screw clamp terminals
Mechanical durability 30000 cycles
Quantity per set Set of 10
Height 89 mm
Width 18 mm
Depth 66 mm
Product weight 0.105 kg
Colour Dark grey
GVAU116 Schneider Electric
Schneider GVAU116 Schneider Electric
Sale price$0.00
Sold Out

TeSys GV electrical trip, MN undervoltage release, 110-115V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage drops below 0.35 Uc, possible opening between 0.35-0.7 Uc. Closing of the circuit breaker is only possible when the control voltage is applied in the range 0.85-1.1 Uc. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC).

Main

Characteristic Value(s)
Range TeSys
TeSys Deca
Product or Component Type Undervoltage release
Device short name GVAU

Complementary

Characteristic Value(s)
Range compatibility TeSys GV2ME
TeSys GV2LE
TeSys GV2L
TeSys GV2P
TeSys GV3L
TeSys GV3P
TeSys Deca
[Uc] control circuit voltage 110...115 V AC 60 Hz
Control circuit voltage limits 0.85...1.1 Un
[Ui] rated insulation voltage 690 V AC IEC 60947-1
600 V AC UL 60947-4-1
600 V AC CSA C22.2 No 60947-4-1
Threshold tripping voltage 0.7...0.35 Un
Inrush power in VA 12 VA AC
Inrush power in W 8 W
Hold-in Power Consumption in VA 3.5 VA AC
Hold-in power consumption in W 1.1 W
Operating time 10...15 ms IEC 60947-1
On-load factor 100 %
Connections - terminals screw clamp terminals 1 0.002…0.004 in² (1…2.5 mm²)solid
screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²)solid
screw clamp terminals 1 0.001…0.004 in² (0.75…2.5 mm²)flexible without cable end
screw clamp terminals 2 0.001…0.004 in² (0.75…2.5 mm²)flexible without cable end
screw clamp terminals 1 0.001…0.002 in² (0.75…1.5 mm²)flexible with cable end
screw clamp terminals 2 0.001…0.002 in² (0.75…1.5 mm²)flexible with cable end
Tightening torque < 1.4 N.m screw clamp terminals
Mechanical durability 10000 cycles with GV3P and GV3L
30000 cycles with GV2ME and GV2P
Quantity per Set Set of 10
Height 3.5 in (89 mm)
Width 0.7 in (18 mm)
Depth 2.6 in (66 mm)
Product Weight 0.231 lb(US) (0.105 kg)
color Dark grey
Schneider New Stock Image
Schneider LRN14N Schneider
Sale price $93.57
Only 9 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider LRN359N Schneider
Sale price $102.92
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Schneider New Stock Image
Schneider GV2ME04C Schneider
Sale price $92.72
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
GV3L73 Schneider Electric
Schneider GV3L73 Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV3, 3P, 73 A, magnetic, rotary handle, EverLink terminals

GV2RT06 Schneider Electric
Schneider GV2RT06 Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 1-1.6 A, thermal magnetic, screw clamp terminals

GV2RT043 Schneider Electric
Schneider GV2RT043 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or component type Motor circuit breaker
Device short name GV2RT
Device application Motor protection
Transformer
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-2
Motor power kW 0.12 kW at 400/415 V AC 50/60 Hz motor protection high peak current
0.18 kW at 400/415 V AC 50/60 Hz motor protection high peak current
0.18 kW at 440 V AC 50/60 Hz motor protection high peak current
0.37 kW at 690 V AC 50/60 Hz motor protection high peak current
Breaking capacity 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 0.63 A
Thermal protection adjustment range 0.4…0.63 A conforming to IEC 60947-2
Magnetic tripping current 13 A
[Ith] conventional free air thermal current 0.63 A conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated duty Uninterrupted conforming to IEC 60947-4-1
Connections - terminals Power circuit: spring terminals 2 cable(s) 1…6 mm²solid
Power circuit: spring terminals 2 cable(s) 1.5…4 mm²flexible without cable end
Power circuit: spring terminals 2 cable(s) 1…4 mm²flexible with cable end
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Mounting position Horizontal
Vertical
Width 45 mm
Height 89 mm
Depth 78.5 mm
GV2ME103 Schneider Electric
Schneider GV2ME103 Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 4-6.3 A, thermal magnetic, spring terminals

GV4P115B6 Schneider Electric
Schneider GV4P115B6 Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic, lugs terminals

GV2RT203 Schneider Electric
Schneider GV2RT203 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV2
Product or component type Motor circuit breaker
Device short name GV2RT
Device application Motor protection
Transformer
Trip unit technology Thermal-magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
AC-3e conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-2
Motor power kW 4 kW at 220/230 V AC 50/60 Hz motor protection high peak current
7.5 kW at 400/415 V AC 50/60 Hz motor protection high peak current
7.5 kW at 440 V AC 50/60 Hz motor protection high peak current
9 kW at 440 V AC 50/60 Hz motor protection high peak current
9 kW at 500 V AC 50/60 Hz motor protection high peak current
15 kW at 690 V AC 50/60 Hz motor protection high peak current
5 kW at 230/240 V AC 50/60 Hz transformer protection
6.3 kW at 230/240 V AC 50/60 Hz transformer protection
10 kW at 400/415 V AC 50/60 Hz transformer protection
10 kW at 440 V AC 50/60 Hz transformer protection
10 kW at 500 V AC 50/60 Hz transformer protection
12.5 kW at 500 V AC 50/60 Hz transformer protection
10 kW at 690 V AC 50/60 Hz transformer protection
Breaking capacity 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2
15 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
8 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2
6 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2
3 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2
control type Toggle
[In] rated current 18 A
Thermal protection adjustment range 13…18 A conforming to IEC 60947-2
Magnetic tripping current 400 A
[Ith] conventional free air thermal current 18 A conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 2.5 W
Mechanical durability 100000 cycles
Electrical durability 100000 cycles for AC-3 at 415 V In
100000 cycles for AC-3e at 415 V In
Rated duty Uninterrupted conforming to IEC 60947-4-1
Connections - terminals Power circuit: spring terminals 2 cable(s) 1…6 mm²solid
Power circuit: spring terminals 2 cable(s) 1.5…4 mm²flexible without cable end
Power circuit: spring terminals 2 cable(s) 1…4 mm²flexible with cable end
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with adaptor plate)
Mounting position Horizontal
Vertical
Width 45 mm
Height 89 mm
Depth 78.5 mm
GV2L07 Schneider Electric
Schneider GV2L07 Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 2.5 A, magnetic, rotary handle, screw clamp terminals

Schneider New Stock Image
Schneider LRD4365 Schneider
Sale price $147.71
Only 7 units left

TeSys LRD overload relays are designed to be used with TeSys D contactors to make a motor starter. This overload relay can be used with 115 amp through 150 amp TeSys D contactors. These differential thermal overload relays detect over currents in the lines to the motor. When an overcurrent is detected the overload relay working with the contactor will disconnect the power to the motor. This will minimize the damage to the motor windings. This overload relay has an adjustable trip current rating of 80 to 104 amperes. This trip current rating is calibrated per Class 10A. Multi standards certified (IEC, UL, CSA, CCC, EAC, ATEX, Marine).

Main

Characteristic Value(s)
Range TeSys
product name TeSys LRD
TeSys Deca
Product or Component Type Differential thermal overload relay
Device short name LRD
Relay application Motor protection
Product Compatibility LC1D115
LC1D150
Network type AC
DC
Thermal overload class Class 10A IEC 60947-4-1
Thermal protection adjustment range 80…104 A
[Ui] rated insulation voltage Power circuit 1000 V IEC 60947-4-1
Power circuit 600 V CSA
Power circuit 600 V UL

Complementary

Characteristic Value(s)
Network Frequency 0...400 Hz
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
Tripping threshold 1.14 +/- 0.06 Ir IEC 60947-4-1
Auxiliary contact composition 1 NO + 1 NC
[Ith] conventional free air thermal current 5 A signalling circuit
Permissible current 0.06 A 440 V DC-13 signalling circuit
0.12 A 600 V AC-15 signalling circuit
[Ue] rated operational voltage 1000 V AC 0...400 Hz power circuit IEC 60947-4-1
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
[Uimp] rated impulse withstand voltage 6 kV IEC 60947-1
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Control type Red push-button stop
Blue push-button reset
Temperature compensation -4…140 °F (-20…60 °C)
Connections - terminals Power circuit screw clamp terminals 1 0.006…0.05 in² (4…35 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible without cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) flexible with cable end
Control circuit screw clamp terminals 2 0.002…0.004 in² (1…2.5 mm²) solid without cable end
Power circuit screw clamp terminals 1 0.006…0.08 in² (4…50 mm²) flexible without cable end
Power circuit screw clamp terminals 1 0.006…0.08 in² (4…50 mm²) solid without cable end
Tightening torque Control circuit 15.05 lbf.in (1.7 N.m) screw clamp terminals
Power circuit 79.7 lbf.in (9 N.m) screw clamp terminals
Depth 5.2 in (132 mm)
Product Weight 2.0 lb(US) (0.9 kg)
GV3L651 Schneider Electric
Schneider GV3L651 Schneider Electric
Sale price$0.00
Sold Out

Main

Characteristic Value(s)
Range TeSys Deca
product name TeSys GV3
Product or component type Motor circuit breaker
Device short name GV3L
Device application Motor protection
Trip unit technology Magnetic

Complementary

Characteristic Value(s)
Poles description 3P
Network type AC
Utilisation category Category A conforming to IEC 60947-2
AC-3 conforming to IEC 60947-4-1
Network frequency 50/60 Hz conforming to IEC 60947-2
Motor power kW 30 kW at 400/415 V AC 50/60 Hz
37 kW at 500 V AC 50/60 Hz
55 kW at 690 V AC 50/60 Hz
Breaking capacity 100 kA Icu at 230/240 V AC 50/60 Hz
50 kA Icu at 400/415 V AC 50/60 Hz
50 kA Icu at 440 V AC 50/60 Hz
12 kA Icu at 500 V AC 50/60 Hz
6 kA Icu at 690 V AC 50/60 Hz
[Ics] rated service short-circuit breaking capacity 100 % at 230/240 V AC 50/60 Hz
100 % at 400/415 V AC 50/60 Hz
100 % at 440 V AC 50/60 Hz
50 % at 500 V AC 50/60 Hz
50 % at 690 V AC 50/60 Hz
control type Rotary handle
[In] rated current 65 A
Magnetic tripping current 910 A
[Ith] conventional free air thermal current 65 A conforming to IEC 60947-2
[Ue] rated operational voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Ui] rated insulation voltage 690 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-2
Suitability for isolation Yes conforming to IEC 60947-1
Power dissipation per pole 8 W
Mechanical durability 50000 cycles
Electrical durability 50000 cycles for AC-3 at 415 V In
Tightening torque 5 N.m - on screw clamp terminal
Fixing mode 35 mm symmetrical DIN rail: clipped
Panel: screwed (with 3 x M4 screws)
Mounting position Horizontal
Vertical
Width 55 mm
Height 114 mm
Depth 136 mm
Product weight 0.96 kg
Colour Dark grey
GVAS505 Schneider Electric
Schneider GVAS505 Schneider Electric
Sale price$0.00
Sold Out

Shunt release (MX), TeSys GV2-GV3, 500V AC 50Hz / 600V AC 60Hz

GV4P25N Schneider Electric
Schneider GV4P25N Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 50kA, thermal magnetic, Everlink terminals

GV4PEM25S6 Schneider Electric
Schneider GV4PEM25S6 Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV4, 3P, 25A, Icu 100kA, thermal magnetic multifunction, lugs terminals

GV2ME033 Schneider Electric
Schneider GV2ME033 Schneider Electric
Sale price$0.00
Sold Out

Motor circuit breaker, TeSys GV2, 3P, 0.25-0.4 A, thermal magnetic, spring terminals

GV2P02 Schneider Electric
Schneider GV2P02 Schneider Electric
Sale price $396.00
Only 2 units left

Motor circuit breaker, TeSys GV2, 3P, 0.16-0.25 A, thermal magnetic, screw clamp terminals

Recently viewed