Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys Deca |
| product name | TeSys GV2 |
| Product or component type | Motor circuit breaker |
| Device short name | GV2RT |
| Device application | Motor protection Transformer |
| Trip unit technology | Thermal-magnetic |
Complementary
| Characteristic | Value(s) |
|---|---|
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 AC-3e conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 0.06 kW at 220/230 V AC 50/60 Hz motor protection high peak current 0.09 kW at 400/415 V AC 50/60 Hz motor protection high peak current 0.09 kW at 440 V AC 50/60 Hz motor protection high peak current 0.12 kW at 440 V AC 50/60 Hz motor protection high peak current |
| Breaking capacity | 100 kA Icu at 220/230 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| control type | Toggle |
| [In] rated current | 0.4 A |
| Thermal protection adjustment range | 0.25â¦0.4 A conforming to IEC 60947-2 |
| Magnetic tripping current | 8 A |
| [Ith] conventional free air thermal current | 0.4 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 2.5 W |
| Mechanical durability | 100000 cycles |
| Electrical durability | 100000 cycles for AC-3 at 415 V In 100000 cycles for AC-3e at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Connections - terminals | Power circuit: spring terminals 2 cable(s) 1â¦6 mm²solid Power circuit: spring terminals 2 cable(s) 1.5â¦4 mm²flexible without cable end Power circuit: spring terminals 2 cable(s) 1â¦4 mm²flexible with cable end |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with adaptor plate) |
| Mounting position | Horizontal Vertical |
| Width | 45 mm |
| Height | 89 mm |
| Depth | 78.5 mm |

TeSys GV accessory, combination block for motor starter assembly. For the connection between a motor circuit breaker GV2 or a fuse carrier LS1D32 and contactor LC1D09-D38. To be used when the assembly is mounted directly on DIN rails. Sold in lots of 10 units.
Main
| Characteristic | Value(s) |
|---|---|
| Range | Linergy |
| product name | FT |
| Device short name | GV2AF |
| Product or Component Type | Combination block |
| Accessory / separate part category | Connection accessory |
| Range compatibility | TeSys GV2 TeSys Deca |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product Compatibility | LC1D09...D38 |
| Poles description | 3P |
| [Ie] rated operational current | 32 A |
| Product Weight | 0.035 lb(US) (0.016 kg) |

TeSys GV motor circuit breaker, 3 poles (3P), 32A/690V, for 3-phase motor applications 15kW@400V. It provides a thermal-magnetic protection with a thermal setting range 23-32A, magnetic tripping at 14xIn, high breaking capacity Icu 100kA@400V. Connection by bars or lugs. Start-stop control by rotary knob guaranteed for 50 000 cycles AC-3. Multi standards certified (IEC, UL, CSA, CCC, EAC, Marine, ATEX), Green Premium compliant (RoHS/REACh).
Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys Deca |
| product name | TeSys GV3 |
| Product or component type | Motor circuit breaker |
| Device short name | GV3P |
| Device application | Motor protection |
| Trip unit technology | Thermal-magnetic |
Complementary
| Characteristic | Value(s) |
|---|---|
| Poles description | 3P |
| Network type | AC |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| Network frequency | 50/60 Hz conforming to IEC 60947-2 |
| Motor power kW | 15 kW at 400/415 V AC 50/60 Hz 18.5 kW at 500 V AC 50/60 Hz 22 kW at 690 V AC 50/60 Hz |
| Breaking capacity | 100 kA Icu at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 kA Icu at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 50 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 12 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 6 kA Icu at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ics] rated service short-circuit breaking capacity | 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2 100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 500 V AC 50/60 Hz conforming to IEC 60947-2 50 % at 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| control type | Rotary handle |
| [In] rated current | 32 A |
| Thermal protection adjustment range | 23â¦32 A conforming to IEC 60947-2 |
| Magnetic tripping current | 448 A |
| [Ith] conventional free air thermal current | 32 A conforming to IEC 60947-2 |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Uimp] rated impulse withstand voltage | 6 kV conforming to IEC 60947-2 |
| Phase failure sensitivity | Yes conforming to IEC 60947-4-1 |
| Suitability for isolation | Yes conforming to IEC 60947-1 |
| Power dissipation per pole | 8 W |
| Mechanical durability | 50000 cycles |
| Electrical durability | 50000 cycles for AC-3 at 415 V In |
| Rated duty | Uninterrupted conforming to IEC 60947-4-1 |
| Tightening torque | 6 N.m - on lugs-ring terminals |
| Fixing mode | 35 mm symmetrical DIN rail: clipped Panel: screwed (with 3 x M4 screws) |
| Mounting position | Horizontal Vertical |
| Width | 55 mm |
| Height | 132 mm |
| Depth | 136 mm |
| Product weight | 0.96 kg |
| Colour | Dark grey |
| Connection pitch | 17.5 mm without spreaders |

Motor circuit breaker, TeSys GV4, 3P, 7A, Icu 50kA, thermal magnetic multifunction, Everlink terminals

TeSys GV busbar set, 3 phases, 63A/690V, for the upstream parallel wiring of groups of motor starters composed of GV2 motor circuit breakers or LS1D32 fuse carriers. For use with screw clamp terminal devices, it is composed of 4 tap-off outlets for the paralleling of 2 devices with a pitch of 54mm. The use of a terminal block GV1G09 or GV2G05 is recommended to supply the busbar sets (to be ordered separately).
Main
| Characteristic | Value(s) |
|---|---|
| Range | Linergy |
| product name | FT |
| Device short name | GV2G |
| Product or Component Type | Comb busbar |
| Accessory / separate part category | Connection accessory |
| Poles description | 3P |
| Range compatibility | TeSys Deca TeSys GV2 TeSys K TeSys U |
| Number of tap-offs | 4 |
| [Ith] conventional free air thermal current | 63 A |
| Connection pitch | 2.1 in (54 mm) |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] Rated Insulation Voltage | 690 V |
| Length | 8.1 in (206 mm) |
| Product Weight | 0.187 lb(US) (0.085 kg) |

Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys |
| Product or Component Type | Universal retrofit |
| Device short name | GVAP |
| Accessory / separate part category | Control accessory |
Complementary
| Characteristic | Value(s) |
|---|---|
| Product Compatibility | GV2APN01 GV2APN02 GV2APN03 GV2APN04 GV3APN01 GV3APN02 GV3APN03 GV3APN04 LU9APN21 LU9APN22 LU9APN24 |
| Product Weight | 0.35 lb(US) (0.16 kg) |
| color | Gray |


TeSys GV electrical trip unit, MN undervoltage release, 277V AC 60Hz, for motor circuit breakers GV4. Opening of the the circuit breaker is ensured when the control voltage drops below 0.35 Uc, and possible between 0.35-0.7 Uc. Closing of the circuit breaker is possible when the control voltage is in limits 0.85-1.1 Uc. To be plugged inside the circuit breaker, connection by spring terminals. Multi standards certified (IEC, UL, CSA), Green Premium compliant (RoHS/REACh).
Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys |
| Device short name | MN |
| Product or Component Type | Voltage release |
| Device Application | Control |
| Range compatibility | TeSys TeSys GV4 TeSys TeSys BV4 |
| Voltage release type | Undervoltage release |
| [Uc] control circuit voltage | 277 V AC 60 Hz |
Complementary
| Characteristic | Value(s) |
|---|---|
| [Ui] rated insulation voltage | 277 V IEC 60947-1 |
| Threshold tripping voltage | < 0.35 Un failsafe opening 0.35...0.7 Un possible opening 0.85...1.1 Un enabled closing |
| Mounting Mode | Internal mounting |
| Maximum inrush power in VA | 7 VA |
| Maximum hold-in power consumption in VA | 7 VA |
| Mechanical durability | 20000 cycles |
| Operating time | < 50 ms |
| Connections - terminals | Spring terminals 1 0.0008â¦0.002 in² (0.5â¦1.5 mm²) - cable stiffness: flexible without cable end |
| Wire stripping length | 0.3 in (8 mm) |

TeSys GV motor circuit breaker, 3 poles (3P), 25A/690V, for protection of 3-phase motors 5.5-11kW@400V. It provides magnetic protection, breaking capacity Icu 25kA@400V, start-stop control by rotary handle, connection for bars or cables with lugs. Magnetic protection adjustable by dial, setting range 6-14 In. It makes internal locations available for additional auxiliary contact blocks (OF, SD), and voltage trip units (MN, MX). To be used in association with a class 10 or 20 thermal overload relay to complete motor protection. Multi standards certified (IEC, CCC, EAC, Marine), Green Premium compliant (RoHS/REACh).
Main
| Characteristic | Value(s) |
|---|---|
| Range of product | TeSys GV4 |
| Range | TeSys Deca |
| Device short name | GV4L |
| product name | TeSys GV4 |
| Product or component type | Motor circuit breaker |
| Device application | Motor protection |
| Trip unit technology | Magnetic Electronic |
Complementary
| Characteristic | Value(s) |
|---|---|
| Poles description | 3P |
| Utilisation category | Category A conforming to IEC 60947-2 AC-3 conforming to IEC 60947-4-1 |
| Operating position | Any position |
| Motor power kW | 7.5 kW at 660...690 V AC 50/60 Hz 5.5 kW at 400...415 V AC 50/60 Hz 7.5 kW at 500 V AC 50/60 Hz 9 kW at 660...690 V AC 50/60 Hz 11 kW at 660...690 V AC 50/60 Hz 7.5 kW at 400...415 V AC 50/60 Hz 9 kW at 400...415 V AC 50/60 Hz 11 kW at 400...415 V AC 50/60 Hz 9 kW at 500 V AC 50/60 Hz 11 kW at 500 V AC 50/60 Hz 15 kW at 500 V AC 50/60 Hz 15 kW at 660...690 V AC 50/60 Hz 18.5 kW at 660...690 V AC 50/60 Hz |
| Breaking capacity | 50 kA Icu at 220...240 V AC 50/60 Hz conforming to IEC 60947-2 25 kA Icu at 380...415 V AC 50/60 Hz conforming to IEC 60947-2 20 kA Icu at 440 V AC 50/60 Hz conforming to IEC 60947-2 10 kA Icu at 500 V AC 50/60 Hz conforming to IEC 60947-2 |
| control type | Rotary handle |
| [In] rated current | 25 A |
| Magnetic tripping current | 150â¦350 A |
| [Ue] rated operational voltage | 690 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ui] rated insulation voltage | 800 V AC 50/60 Hz conforming to IEC 60947-2 |
| [Ith] conventional free air thermal current | 115 A conforming to IEC 60947-4-1 |
| [Uimp] rated impulse withstand voltage | 8 kV conforming to IEC 60947-2 |
| Power dissipation per pole | 6.1 W |
| Mechanical durability | 40000 cycles |
| Electrical durability | 40000 cycles for AC-3 at 440 V In/2 20000 cycles for AC-3 at 440 V In |
| Maximum operating rate | 25 cyc/h |
| Rated duty | Continuous conforming to IEC 60947-4-1 |
| Connection pitch | 27 mm without spreaders 35 mm with spreaders |
| Connections - terminals | Lugs-ring terminals |
| Tightening torque | 9 N.m for cable 16â¦95 mm² 5 N.m for cable 1.5â¦10 mm² |
| Mechanical robustness | Vibrations: +/- 1 mm 2...13.2 Hz conforming to IEC 60068-2-6 Vibrations: 0.7 gn 13.2...100 Hz conforming to IEC 60068-2-6 Shocks: 15 gn 11 ms conforming to IEC 60068-2-27 |
| Height | 155 mm |
| Width | 81 mm |
| Depth | 165 mm |
| Product weight | 1.65 kg |
| Colour | Grey (RAL 7016) |
| Suitability for isolation | Yes conforming to IEC 60947-1 |


Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 50kA, thermal magnetic multifunction, lugs terminals

Motor circuit breaker, TeSys GV4, 3P, 115A, Icu 25kA, thermal magnetic multifunction, Everlink terminals

TeSys GV electrical trip, MX shunt release, 380-400V AC 60Hz, for motor circuit breakers GV2, GV3. It trips the circuit breaker when the control voltage is applied in limits 0.7-1.1 Uc with an impulse duration greater than 20ms or a maintained signal. To be mounted on right-hand side of the circuit breaker, connection by screw clamp terminals. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Main
| Characteristic | Value(s) |
|---|---|
| Range | TeSys |
| Product or Component Type | Shunt trip release |
| Device short name | GVAS |
Complementary
| Characteristic | Value(s) |
|---|---|
| Range compatibility | TeSys GV2ME TeSys GV2LE TeSys GV2L TeSys GV2P TeSys GV3L TeSys GV3P |
| [Uc] control circuit voltage | 380...400 V AC 60 Hz |
| Control circuit voltage limits | 0.7...1.1 Un |
| [Ui] rated insulation voltage | 690 V AC IEC 60947-1 600 V AC UL 60947-4-1 600 V AC CSA C22.2 No 60947-4-1 |
| Threshold tripping voltage | 0.75...0.2 Un |
| Inrush power in VA | 14 VA AC |
| Inrush power in W | 10.5 W |
| Hold-in Power Consumption in VA | 5 VA AC |
| Hold-in power consumption in W | 1.6 W |
| Operating time | 10...15 ms IEC 60947-1 |
| On-load factor | 100 % |
| Connections - terminals | screw clamp terminals 1 0.002â¦0.004 in² (1â¦2.5 mm²)solid screw clamp terminals 2 0.002â¦0.004 in² (1â¦2.5 mm²)solid screw clamp terminals 1 0.001â¦0.004 in² (0.75â¦2.5 mm²)flexible without cable end screw clamp terminals 2 0.001â¦0.004 in² (0.75â¦2.5 mm²)flexible without cable end screw clamp terminals 1 0.001â¦0.002 in² (0.75â¦1.5 mm²)flexible with cable end screw clamp terminals 2 0.001â¦0.002 in² (0.75â¦1.5 mm²)flexible with cable end |
| Tightening torque | < 1.4 N.m screw clamp terminals |
| Mechanical durability | 10000 cycles with GV3P and GV3L 30000 cycles with GV2ME and GV2P |
| Quantity per Set | Set of 10 |
| Height | 3.5 in (89 mm) |
| Width | 0.7 in (18 mm) |
| Depth | 2.6 in (66 mm) |