Specifications
Model |
GL-SS015 |
|||
Type |
Standard cable |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
1 |
|||
Cable end |
Main unit connection connector - Main unit connection connector |
|||
Length |
0.15 m 0.49' |
|||
Note |
Use this with one-line systems and series connections. |
|||
Weight |
20 g |
|||


Specifications
Model |
IV-H1SN |
|||
Included software |
IV4 Series, IV3 Series: IV Smart Navigator |
|||
Compatible sensor |
IV4 Series, IV3 Series, IV2 Series, IV Series |
|||
System requirements |
Interface |
Ethernet (1000BASE-T) interface installed |
||
OS |
[IV Smart Navigator] |
|||
Languages |
English, Japanese, Chinese (Simplified), Chinese (Traditional), Korean, German, Italian, French, Spanish, Portuguese, Czech, Hungarian, Polish, Thai *1 |
|||
Processor |
[IV Smart Navigator] |
|||
Memory capacity |
[IV Smart Navigator] |
|||
Required capacity for installation |
[IV Smart Navigator] |
|||
Monitor |
Resolution of 1024×768 pixels or greater |
|||
Operating conditions |
[IV Smart Navigator] |
|||
*1 When connecting to the IV3 Series, the IV Smart Navigator or IV3-Navigator languages will apply respectively. When connecting to the IV2 Series or IV Series, the IV2-Navigator or IV-Navigator languages will apply respectively. | ||||

Specifications
Model |
SI-F01 |
|||
Type |
Micro-head type Sensor head |
|||
Measurement range |
0.05 to 1.1 mm 0.002" to 0.04" *1 |
|||
Light source |
Infrared SLD Central wavelength 820 nm Output 0.6 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
Spot diameter |
ø20 µm ø0.000787"*3 |
|||
Linearity |
±0.3 µm ±0.000012"*4 |
|||
Resolution |
0.25 µm 0.00000984"*5 |
|||
Sampling cycle |
200 µs |
|||
Light source for guide |
Red semiconductor laser Wavelength 655 nm Output 0.1 mW Class 1 Laser product (IEC60825-1/FDA (CDRH) Part 1040.10*2) |
|||
LED display |
Target near center of measurement range: green lights. Target within measurement range: orange lights. Target outside measurement range: Flashes orange. |
|||
Temperature fluctuation |
0.01% of F.S./°C |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient light |
Incandescent lamp or Fluorescent lamp: 10,000 lux max. |
|||
Ambient temperature |
0 to +85 °C 32 to 185 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
SUS |
|||
Material |
Sensor head |
|||
Spectrum unit |
Polycarbonate |
|||
Weight |
Approx. 24 g (including cable) |
|||
*1 Indicates distance from the front of the sensor head. For long distance type sensor heads there is an individual difference of up to ±0.2 mm ±0.01". | ||||

Specifications
Model |
FU-85 |
|||
Heat resistant temperature |
105°C 221°F*1 |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø2.2×2 |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +105 °C -40 to 221 °F |
||
Weight |
Approx. 21 g |
|||
*1 Use in a dry state. Also, when using the heat resistant type, make a selection with ample room for the ambient temperature. | ||||

Specifications
Model |
KV-NC10L |
|||
Transmission |
Electrical termination (Terminator) |
− |
||
Baud rate |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps |
|||
Transmission method |
Full duplex |
|||
Data format |
Start bit |
1 bit |
||
Data bits |
7 bits, 8 bits |
|||
Stop bits |
1 bits, 2 bits |
|||
Error detection |
Parity |
Even, odd, none |
||
RS/CS flow control |
Enabled, disabled |
|||
Interface |
Communication standard |
RS-232C |
||
Connection |
D-sub 9-pin |
|||
Transmission |
Transmission distance |
15 m 49.2' |
||
Number of transmission units |
1 |
|||
Indication |
SD (orange), RD (orange) |
|||
Weight |
Approx. 100 g |
|||

Specifications
Model |
OP-84454 |
|||
Overview |
Used to perform maintenance on the inside wall of the electrode probe cap. |
|||

Specifications
Model |
SJ-E180H |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method / Applied voltage |
Pulse AC method/±8000 V |
|||
Ion balance control method |
Hi-Power I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Installation distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
Static elimination stop input |
NPN open collector or contact point signal without voltage |
||
Control output |
Ion level warning, condition warning, alarm output |
NPN open collector, Maximum 100 mA (40 VDC or less) |
||
Condition alarm output | ||||
Alarm output | ||||
Communication function |
Remote control communication |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air connection port |
Rc 1/8 |
|||
Air supply pressure |
0.1 MPa to 0.5 MPa*2 |
|||
Effective length |
1860 mm 73.23"*3 |
|||
Total length |
1760 mm 69.29" |
|||
No. ofelectrodes |
57 |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
700 mA (at 24 V), 500 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main body |
ABS/PBT/PP/LCP/PPS/SPS/SUS |
|||
Weight |
1950 g 68.78oz |
|||
*1 Measured under the following conditions. | ||||

Specifications
Model |
AI-D32B |
|||
Type |
Dome Attachment for Built-in amplifier models, Large |
|||
Applicable product |
AI-B100, AI-B160 |
|||
Note |
Effective area 32 × 32 mm 1.26 × 1.26" |
|||

Specifications
Model |
CL-L007 *1 |
|||
Type |
Sensor head (Compact ø8 ・Quad type) |
|||
*1 The sensor head and optical unit have been configured as a pair. Specifications can be found on the page relating to the optical unit. | ||||

Specifications
Model |
IV-500MA |
|||
Type |
Standard distance |
|||
Installed distance |
50 to 500 mm 1.97" to 19.69" |
|||
View |
Installed distance 50 mm 1.97": 25 (H) x 18 (V) mm 0.98" (H) x 0.71"(V) to |
|||
Image sensor |
Type |
1/3 inch monochrome CMOS |
||
Pixel |
752 (H) x 480 (V) 29.61" (H) x 18.90" (V) |
|||
Focus adjustment |
Auto*1 |
|||
Exposure time |
1/10 to 1/25,000 |
|||
Lights |
Illumination |
Red LED |
||
Lighting method |
Pulse lighting/DC lighting is switchable |
|||
Tools |
Type |
Shape Detection, Color Area*2, Area*3, position adjustment |
||
Number |
Detection tools: 16 tools, position adjustment tool: 1 tool*4 |
|||
Switch settings (programs) |
32 programs |
|||
Image history |
Numbers |
300 images*5*6 |
||
Condition |
NG only/All is selectable*6 |
|||
Analysis information |
OFF/Statistics/Histograms is switchable |
|||
Other functions |
HDR, HighGain, Color filters*2, Digital zoom*8, Brightness correction, Tilt correction, White balance*2, |
|||
Indicators |
PWR/ERR, OUT, TRIG, STATUS, LINK/ACT |
|||
Input |
Type |
Non-voltage input/voltage input is switchable |
||
Inputs |
6 inputs (IN1 to IN6) |
|||
Function |
IN1: External trigger, IN2 to IN6: Enable by assigning the optional functions |
|||
Output |
Type |
Open collector output NPN/PNP is switchable, N.O./N.C. is switchable |
||
Outputs |
4 outputs (OUT1 to OUT4) |
|||
Function |
Enable by assigning the optional functions |
|||
Ethernet |
Standard |
100BASE-TX/10BASE-T*10 |
||
Connector |
M12 4pin connector*10 |
|||
Network function |
FTP client, EtherNet/IP™, PROFINET |
|||
Rating |
Power voltage |
24 VDC ±10 % (including ripple) |
||
Current consumption |
0.6 A or less |
|||
Environmental resistance |
Enclosure rating |
IP67*11 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions*12 |
|||
Shock resistance |
500 m/s2, 3 times in each of 6 directions*12 |
|||
Material |
Main unit case: Aluminium die-casting, Packing: NBR, Front cover: Acrylic, Mounting adapter: POM |
|||
Weight |
Approx. 270 g |
|||
*1 The focusing position can be automatically adjusted at the time of installation. Deactivated during the operation. Focusing position can be registered by program. | ||||


Specifications
Model |
GL-SPT10P |
|||
Type |
M14 connector cable for connecting to the GL-T11R |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
1 (set includes transmitter and receiver) |
|||
Cable end |
Main unit connection connector - M14 connector, straight |
|||
Output |
PNP |
|||
Length |
10 m 32.81' |
|||
Weight |
540 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


Specifications
Model |
CB-B05LU |
|||
Type |
Extension cable L-shape connector (top) |
|||
Cable length |
0.5m 1.64' |
|||
Cable min. bending R |
22mm |
|||
Material |
PVC (jacketing) |
|||
Weight |
Approx. 70g |
|||