Machine Vision Systems

5768 products

Showing 1201 - 1224 of 5768 products

Showing 1201 - 1224 of 5768 products
View
keyence Stock Image
Keyence FU-67MG Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence VL-A4 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-8154 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence FS-V21RM Keyence
Sale price $548.07
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Keyence New Stock Image
Keyence GL-R39F-R Keyence
Sale price $1,869.05
Only 4 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88895 Keyence
Sale price $531.06
Only 1 unit left

Specifications

Model

OP-88895

Female

M12 8-pin Straight

Male

Strand wire

Length

10 m 32.8'

Material

cable: PVC
connector: SUS316L

Keyence New Stock Image
Keyence LV-H37 Keyence
Sale price $1,050.21
Only 7 units left

Specifications

Model

LV-H37

Type

Ultra-small beam spot

FDA (CDRH) Part 1040.10

Class II

Light source

Visible red semiconductor laser

Wavelength

660 nm

Detecting distance

FINE

70 ±15 mm 2.76" ±0.59"

TURBO

SUPER

Environmental resistance

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Material

Case

Glass reinforced plastic *1

Lens cover

Glass *2

Weight

Approx. 45 g

*1 Norbornene plastic or acrylic
*2 The LV-H32 and the LV-H37 receivers are polyarylate.

keyence Stock Image
Keyence GL-RS3 Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-RS3

Type

Joint Cable

Number included

1 cable

Cable end

Both ends of the connector (Black) are the same shape. The connector can be connected in either direction.

Length

3 m 9.84'

Material

Main unit connection connector: PBT, Cable: PVC

Note

Use this when using the product in a one-line system or when connecting the product in series.

Weight

Approx. 165 g

keyence Stock Image
Keyence AP-13SK Keyence
Sale price$0.00
Sold Out

Specifications

Model

AP-13SK

Type

Positive Sensor Head

Rated pressure

0 to 145 PSI

Fluid type

Gases and liquids compatible with 304 and 630 stainless steel

Type of pressure

Gauge pressure

Repeatability

0.5 % of F.S. max.

Connection port

1/8 NPT

Environmental resistance

Enclosure rating

IP67

Pressure resistance

290 PSI

Ambient temperature

-10 to 70°C(14 to 158°F), No condensation

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 3 hours respectively

Shock resistance

500 m/s2 in X, Y, and Z directions 10 times respectively (60 times in total)

Material

Diaphragm pressure port: TYPE S17400 stainless steel, Pressure port: 304 stainless steel, Throttle: 304 stainless steel (AP-14SK/15SK/16SK only)

Accessories

Sensor head connector: 1

Weight

Approx. 120 g

keyence Stock Image
Keyence GL-RP30P Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-RP30P

Type

Unit connection cable

Number included

1 cable

Cable end

Main unit plug (Black) - Loose wires

Length

30 m 98.42'

Material

Main unit connection connector: PBT, Cable: PVC

Note

Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2)

Weight

Approx. 1200 g

keyence Stock Image
Keyence MP-FG10R Keyence
Sale price$0.00
Sold Out

Specifications

Model

MP-FG10R

Type

Standard model

Connection bore diameter

G3/8" (10 A)

Supported gases

Air and non-corrosive gases

Supported gas temperature

-5 to +50°C, 23 to 122°F

Operating pressure range

0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1

Pressure resistance

1.5 MPa, 15 bar, 217.5 psi

Flow rate

Detection principle

Heat based (mass flow rate)

Rated flow range (normal)

2.0 to 1000.0 L/min
0.12 to 60.00 m3/h 4.24 to 2118.88 ft3/h 0.07 to 35.31 CFM

Zero cut flow rate

2.0 L/min, 0.12 m3/h 4.24 ft3/h, 0.07 CFM

Measurement accuracy

±(1.5% of RD + 0.5% of F.S.) *2 *3

Repeatability

±1.0% of F.S. (with an averaging time of 1.0 s)

Display resolution

0.1 L/min, 0.01 m3/h 0.35 ft3/h, 0.01 CFM

Response time

150 ms (63% response) *4

Averaging time

OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable)

Pressure (Digital value, gauge pressure)

Rated pressure range

0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi

Measurement accuracy

±2.0% of F.S.

Repeatability

±0.2% of F.S. (with a response time of 50 ms)

Display resolution

0.001 MPa, 0.01 bar, 0.1 psi

Response time

Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4

Humidity (Dew point)

Rated relative humidity range/ dew point range

15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6

Measurement accuracy

±4°C, ±7°F *5 *6

Display resolution

5%RH/1°C, 1°F *5 *6

Temperature

Measurement accuracy

±2.0°C, ±3.6°F *7

Display resolution

0.1°C, 0.1°F *7

Shut-off valve

Response time

1 s or less (closed → open)

Leakage amount

50 mL/min 0.002 CFM (N) or less

Filter/regulator (Standard model only)

Pressure adjustment range

0.15 to 0.90 MPa

Filtration degree

5 μm 0.196850 Mil

Drainage cup capacity

60 cc

Check valve

Available

Display

Color LCD, status indicator

Data accumulation

Accumulation period

Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks

Data reading

USB 2.0/Ethernet

I/O

Control output (Ch.1/2/3/4/5)

NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less

Analog output (Ch.1/2)

4 to 20 mA, load resistance: 260 Ω or less *4

External input (Ch.2/3/6)

Short-circuit current: 1.5 mA or less, input time: 20 ms or more

Protection circuit

Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output

Power supply

Power voltage

24 VDC +25%/-20% (including ripple), Class 2 or LPS

Power consumption

1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current)

Communication interface

USB2.0

Network compatibility

When using only this unit: IO-Link (Specification v1.1/COM3) *9
When connecting MP-FEN1 : EtherNet/IP™, PROFINET, Modbus/TCP, MC protocol/SLMP

Environmental resistance

Enclosure rating

IP67 (IEC60529) *10

Ambient temperature

−5°C to +50°C 23°F to 122°F (no freezing) *11

Relative humidity

35%RH to 85%RH (no condensation)

Vibration resistance

10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions

Shock resistance

300 m/s2, XYZ axes, 10 times for each axis

Material

Sensor part : PET/PPS/PBT/POM/aluminum/SPHC
Filter/regulator : Aluminum/POM/HDPE/NBR/Nylon *12

Weight

Approx. 1050 g 37.04 oz (excluding drainage cup)

*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve.
*2 This value is guaranteed by KEYENCE inspection facilities while testing with air. Errors will be introduced by factors such as the gas type, gas temperature, and ambient temperature.
*3 Value in an environment with a constant temperature of 25°C 77°F and compressed air evaluated as purity class 1*1 (ISO 8573-1 (2010)/JIS B 8392-1 (2012)).±(5.5% of RD + 0.5% of F.S.) when equivalent to purity class 3*4.
*4 15 ms is added to the analog output response time.
*5 Measurable when at least 2% of F.S. worth of gas is flowing.
*6 The prescribed accuracy may not be met or the unit may be damaged if the compressed air contains a large amount of oil mist, organic solvent, or other gas. (For details, see “Gas Being Measured” on page 4.)
*7 When the flow is 5% of F.S. or higher. Errors due to heat generated by the main unit occur when the flow is too small.
*8 When connecting MP-FEA1 and/or MP-FEN1, add each device’s current consumption (2.1 A or less including load current).
*9 Use an IO-Link master that can supply 1.2 A or more. (1.6 A or less when connecting an MP-FEA1 and an MP-FEN1.) IO-Link is a registered trademark or trademark of PROFIBUS Nutzerorganisation e.V. (PNO).
*10 When protection is provided to prevent dust and liquid from intruding through the exhaust port. The IP67 enclosure rating is lost when a USB connection is established.
*11 If this product is used with a power supply voltage of 26.4 V or more, the upper limit on the ambient temperature is 45°C 113°F.
*12 Nylon is only used on the MP-Fx20R.

Keyence Stock Image
Keyence BL-501HSO Keyence
Sale price $750.00
Only 3 units left
Buy the Keyence BL-501HSO - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence BL-501HSO is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence VS-S320CX Keyence
Sale price$0.00
Sold Out

Specifications

Model

VS-S320CX

Storage

Internal storage

7 GB

microSD card (external)

Max. 64 GB *1

Image sensor

Frame rate

83 fps

Lens

Mount

Lens-integrated type

Max. optical magnification

× 2.4

Installation distance

50 mm to 500 mm 1.97" to 19.69" *2

Field of view

22 mm to 417 mm 0.87" to 16.42"

I/O connection

Number of inputs

1 (insulated)

Number of outputs

3 (insulated)

Number of inputs/outputs

2 (insulated) (input and output switched via settings)

I/F

Ethernet

PoE IEEE 802.3at, M12 X cable × 1

I/O

1 In/3 Out/2 In, Out M12 A cable × 1

Lighting interface

Dedicated lighting connection interface × 1

External media

microSD card slot × 1 (UHS-1)

Functions

Imaging mode

1.6 M
3.2 M

Output image pixels

(3.2 M mode)
2048×1536
1536×2048
1776×1776
2368×1328
1328×2368
3072×1024
1024×3072

Exposure time

0.028 msec to 1000 msec

Image correction functions

Gain, Offset, Gamma correction, White balance, Fine HDR

Indicators

OLED display, Status LED, Ethernet LED (LINK/ACT), SD card access indicator

Buttons

Operation buttons × 3

Installation support functions

Pointer (Class 1 laser product *3), Angle monitor

Power supply

Power voltage

24 V +25%/−20% or PoE (IEEE802.3at Power Class 4)

Current consumption (camera only)

0.97 A, 18.7 W (for 19.2 V)/0.78 A, 18.7 W (for 24 V)

Current consumption (including lighting)

4.7 A, 89.7 W (for 19.2 V)/3.8 A, 89.7 W (for 24 V)

Current consumption (With CA-DEx10X connected)

11.3 A, 216.7 W (for 19.2 V)/9.1 A, 216.7 W (for 24 V) *4

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.05 G2/Hz; X, Y, and Z directions, 0.5 hours (IEC60068-2-64)

Shock resistance

50 G, 3 times in each of the 6 directions (IEC60068-2-27)

Size (H×W×D)

122.3 mm × 52.6 mm × 69.2 mm 4.81" × 2.07" × 2.72"

Case temperature

0°C to 65°C 32 to 149°F *5

Standard certifications

CE, FCC, NRTL, KC, UKCA

Material

Case: Aluminum die-casting, Front cover: Glass *6

Weight

Approx. 570 g 20.12 oz

*1 Using the configuration software, format the media before use.
*2 VS-LxxxMX/CX’s field-of-view measuring range is 150 mm to 3000 mm 5.91" to 118.11". VS-SxxxMX/CX’s field-of-view measuring range is 50 mm to 500 mm 1.97" to 19.69".
*3 FDA (CDRH) Part 1040.10 (The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of Laser Notice), IEC60825-1.
*4 Maximum instantaneous current. Average current is below current consumption (including lighting).
*5 Reference - Case temperature 65°C 149°F with 200 mm × 200 mm × 10 mm 7.87" × 7.87" × 0.39" aluminum board and at ambient temperature of 40°C 104°F.
*6 ESD-Safe, IEC61340-5-1 compliant.

keyence Stock Image
Keyence OP-87669 Keyence
Sale price $309.59
Only 1 unit left

Specifications

Model

OP-87669

Type

Spacer for flat

Applicable product

PR-F Series

Number included

2 sets

Material

SUS303

Weight

Approx. 1 g

Keyence Stock Image
Keyence CV-X152A Keyence
Sale price $4,920.50
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence MP-F20ADM Keyence
Sale price$0.00
Sold Out

Specifications

Model

MP-F20ADM

Type

Auto drain cup

Connection diameter

NPT1/2 (15A)

Material

Metal

keyence Stock Image
Keyence ER-U08TPC Keyence
Sale price$0.00
Sold Out

Specifications

Model

ER-U08TPC *1 *2

Type

Ultra-long distance unshielded type Screw type M8 Connector (M8 3-pin) PNP output

Power supply cable length

*3

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

Available

Button

Function

Distance switching

Detecting distance

With default settings (Mode 1)

9 mm 0.35" ±10% *4

With distance switching (Mode 2)

6 mm 0.24" ±10% *4

Response frequency

With default settings (Mode 1)

15 Hz *5 *6

With distance switching (Mode 2)

45 Hz *5 *6

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *7

Standard detectable object (Iron, t = 1 mm 0.04")

27 × 27 mm 1.06" × 1.06"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F
(-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F
(+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less
50 mA or less for 1 output, or 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) /
2.3 V or less (Output current: 10 to 50 mA) *8

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less
(32 mA or less at 24 V, 47 mA or less at 16 V) *9

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *10

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 20 g 0.71 oz

*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps).
*2 Long-body type. See “Dimensions” for details.
*3 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections.
*4 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*5 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detection target is 1/2 the detecting distance.
*6 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*7 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*8 Residual voltage is for when a 2 m 6.6' cable is used.
*9 For IO-Link-compatible devices listed under *1, power consumption is as follows.
M8 type: 840 mW or less (35 mA or less at 24 V, 53 mA or less at 16 V)
M12 type: 1090 mW or less (46 mA or less at 24 V, 69 mA or less at 16 V)
M18, M30 type: 1250 mW or less (53 mA or less at 24 V, 79 mA or less at 16 V)
*10 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence NQ-P8B5 Keyence
Sale price$0.00
Sold Out

Specifications

Model

NQ-P8B5

Length

5 m 16.4'

Material

PVC

Weight

Approx. 750 g 26.45 oz

Keyence New Stock Image
Keyence AT-V501H Keyence
Sale price $787.43
Only 5 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence FD-SS20A Keyence
Sale price $1,025.55
Only 8 units left
Buy the Keyence FD-SS20A - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence FD-SS20A is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence New Stock Image
Keyence CA-DBW12W Keyence
Sale price $1,106.21
Only 9 units left

Specifications

Model

CA-DBW12W

Type

Bar Light

LED color

White

Diffusion plate

A diffusion plate is included with the CA-DBWxxW. The thickness of the diffusion plate is approximately 2 mm 0.08".

Power consumption

13.8 W

Input voltage

12 VDC

Polarizing diffusion plate

OP-87975*1

Weight

Approx. 195 g

*1 The included diffusion plate and polarizing diffusion plate cannot be used with the product at the same time. There may be air bubbles or foreign substances on the surface of the polarizing diffusion plate, but these have no effect on the image quality. Even if such substances are present, the product is still within the inspection standards, and these substances do not indicate that the product is defective.

Keyence Stock Image
Keyence EX-V02P Keyence
Sale price $2,308.18
Only 2 units left

Specifications

Model

EX-V02P*1

Type

Amplifier Unit PNP

Shape

M10 x 18 mm 0.71" Threaded

Measuring range

0 to 2 mm 0.08"

Display range

-19,999 to +19,999

Linearity

±0.3% of F.S.

Resolution (No. of averaging
measurements: 64)

0.4 μm

Sampling rate

40,000 samplings max./sec. *2

Display speed

20 times/sec.

Display power

7-segment 2-color LED

Over-range alarm

±FFFF is displayed.

Control input

PNP: Applied voltage; 10 to 30 V

Control output

Setting method

Upper/lower 2-level setting x 4 patterns (selectable)

Signal

PNP open-collector (HIGH, GO and LOW): 100 mA max. (30 V max.)

Response time

0.075 ms (at maximum speed)

OFF-delay time

60 ms

Strobe output

PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.)

Alarm output

PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.)

Analog output voltage

Output voltage

±5V

Impedance

100 Ω

Response time

0.075 ms (at maximum speed)

Temperature characteristics

0.07% of F.S./°C *3

Major functions

FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc.

Rating

Power voltage

24 VDC ±10%, Ripple (P-P): 10% max.

Current consumption

240 mA max.

Environmental resistance

Ambient temperature

0 to 50°C 32 to 122 °F

Relative humidity

35 to 85%, No condensation

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Weight

Approx. 235 g

*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials.
*2 When the digital filter function is used, the sampling rate is 20,000 sampling/sec.
*3 When the distance between the sensor head and the target is within 50% of the measuring range.

keyence Stock Image
Keyence ER-GL12N Keyence
Sale price$0.00
Sold Out

Specifications

Model

ER-GL12N

Type

General-purpose all-metal shielded type Screw type M12 Cable NPN output Long-Range

Power supply cable length

2 m 6.6' *1

No. of control outputs

1

Output mode

Output 1

N.O.

Output 2

Button

None

Button

Function

Detecting distance

7 mm 0.28" ±10% *2

Response frequency

100 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

21 × 21 mm 0.83" × 0.83"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F (+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs

Control output

Residual voltage

NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

1000 mW or less
(42 mA or less at 24 V, 63 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529), IP67G (JIS C 0920)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

1000 m/s2 3280.8 ft/s2 (100 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: SUS303, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Connector with pigtail] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC, Connector resin: TPU, Connector metal: Nickel-plated brass
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 75 g
2.65 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

Keyence New Stock Image
Keyence BL-600HA Keyence
Sale price $825.00
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed