Machine Vision Systems

5768 products

Showing 5473 - 5496 of 5768 products

Showing 5473 - 5496 of 5768 products
View
keyence Stock Image
Keyence OP-87698 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence SJ-M400 Keyence
Sale price $1,626.25
Only 9 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

FS-V33 Keyence
Keyence FS-V33 Keyence
Sale price $238.31
In stock, 12 units

Specifications

Model

FS-V33

Type

2-output + 1-input with cable

Output

NPN

Main unit/Expansion unit

Main unit

Control output

2 outputs

Monitor output (1 to 5 V)

N/A

External input

1 input

Connector

Light source LED

Red, 4-element LED (Wavelength: 640 nm)

Response time

33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO)

Output selection

LIGHT-ON/DARK-ON (switch-selectable)

Display indicator

Operation indicator: Red LED/Dual digital monitor: Dual 7-segment display, Preset Value (4-digit green LED indicator) and
Current Value (4-digit red LED indicator) illuminated together. Current Value range: 0 to 64,512; Excess gain: 0P to 999P,
Hold function: Possible to display both peak and bottom hold values, Selectable from 5 variations
Bar LED monitor: Excess gain displayed (85% to 115% in 7 steps), Scaling display

Size

30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D)

Detection mode

Light intensity (area detection possible, automatic sensitivity-tracking function provided)/
[Limited light intensity/Count check/Abnormality detection]

Timer function

OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable
Timer duration selectable: 0.1 ms to 9,999 ms, Maximum error against the setting value: ±10% max.

Control output

NPN open-collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max.

External inputy

Input time: 2 ms (ON)/20 ms (OFF) min.*2

Unit expansion

Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units.

Number of interference prevention units

Normal operation

HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台

Rating

Power voltage

12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less

Power consumption

Normal: 710 mW max. (Using 24 V, 29 mA max., using 12 V, 40 mA max.)/Power saving: 540 mW max. (Using 24 V, 22 mA max., using 12 V, 28 mA max.)*3

Environmental resistance

Ambient light

Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max.

Ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

500 m/s2, 3 times in each of the X, Y, and Z directions

Case material

Polycarbonate

Accessories

N/A

Weight

Approx. 80 g

*1 Total current of two outputs should be less than 100 mA.
*2 Only available on certain models.
*3 When using the HIGH SPEED mode, the power consumption increases by 160 mW (7 mA).
*4 If more than one unit is used together, the ambient temperature varies with the conditions below. Mount the units on the DIN rail with mounting brackets and check that the output current is 20 mA or less.
1 to 2 Units: -10 to +55 °C 14 to 131 °F, 3 to 10 Units: -10 to +50 °C 14 to 122 °F, 11 to 16 Units: -10 to +45 °C 14 to 113 °F

keyence Stock Image
Keyence XT-060 Keyence
Sale price $41,078.25
Only 1 unit left

Specifications

Model

XT-060

Type

60‑mm 2.36" type

Image Sensor

Monochrome CMOS image sensor

Display Size (3D)

Type

3072 × 3072 (1536 × 1536) pixels

XY Data Interval

19.6 µm (39.2 µm)

Display Size (2D)

Type

3072 × 3072 (1536 × 1536) pixels

XY Data Interval

19.6 µm (39.2 µm)

XYZ Repeatability (σ)

1 µm*1*2

Measurement Accuracy

Height Difference

±20 µm*3

Width

Shutter Speed

50 µs to 200 ms

Field of View XY

Near Side

60.2 × 60.2 mm 2.37" × 2.37"

Reference Distance

Far Side

Z Range (via Reference Distance)

±6 mm ±0.24"

WD (to Reference Plane)

200 mm 7.87"

Light Source

LEDs (red, green and blue) can be set individually across 100 levels

Connected to

XG-X2902/X2802

Display

LED display

Power supply/Operation mode

Ratings

Power voltage

24 VDC ±10%

Power consumption

3 A

Environmental resistance

Ambient temperature

0°C to 40°C 32 to 104°F

Relative humidity

85%RH or less (No condensation)

Dimensions

286 × 286 × 286 mm 11.26" × 11.26" × 11.26"

Weight

10.1 kg

*1 3×3 mean filter, using KEYENCE reference workpiece (binning ON)
*2 Repeatability at center of field of view (60 mm 2.36" type: 30 × 30 mm 1.18" × 1.18" center, 24 mm 0.94" type: 12 × 12 mm 0.47" × 0.47" center)
*3 Using KEYENCE height difference gauge. 60 mm 2.36" types - Height difference: 2 mm 0.08"/Width: 20 mm 0.79", 24 mm 0.94" types - Height difference: 1 mm 0.04"/Width: 10 mm 0.39"

Keyence New Stock Image
Keyence PR-G51P Keyence
Sale price $438.45
Only 5 units left

Specifications

Model

PR-G51P

Type

Thrubeam

Shape

Rectangular

Output

PNP

Cable connection

2 m cable

Detecting distance

30 m 98.43'

Number of control outputs

2 (Dark-ON +Light ON)*1

Output operation

Output 1

Dark-ON

Output 2

Light-ON*2

Response time

1 ms

Sensitivity adjustment

One-turn trimmer (230°)

Spot diameter

Light source

4 elements, Red LED (631 nm)

Light interference prevention function

Indicator lamp

Transmitter: power supply indicator (green)
Receiver: output indicator (yellow),
Stable operation indicator (green)

Control output

PNP open collector
30 VDC or less, 100 mA or less
Residual voltage: 1.2 V or less at less than 10 mA, 2 V or less at 10 to 100 mA

Stop emission input

Non-voltage input
Input time ON: 1 ms or more,
OFF: 20 ms or more

Protection circuit

Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %

Power consumption

Transmitter: 450 mW max.
(15 mA max. at 24 V, 15 mA max. at 12 V)
Receiver: 360 mW max.
(12 mA max. at 24 V, 15 mA max. at 12 V)

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9),
4X, 6P, 13 (NEMA250)*3

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less

Ambient temperature

-20 to +70 °C -4 to 158 °F (No freezing)*4

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-20 to +70 °C -4 to 158 °F

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS 316L,
Indicator cover: PES,
7-segment display cover/Lens cover: PMMA (scratch-resistant coating)
M18 nut: Brass (Nickel plating),
Lock washer: Steel (Chrome plating)

Accessories

Instruction manual

Weight

Approx. 160 g

*1 For the threaded mount type sensors, the outputs are 1 NPN output and 1 PNP output.
*2 Output 2 is not available on the threaded mount type or M8 3-pin type.
*3 For the connector type, the enclosure rating varies depending on the cable that is used.
*4 When the ambient temperature is 60 °C 140 °F or higher, the device should be powered with no more than 24 VDC and 50 mA.

keyence Stock Image
Keyence MB-HZM Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88378 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-87466 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence GL-RC10S Keyence
Sale price$0.00
Sold Out

Specifications

Model

GL-RC10S

Type

Extension Cable

Applicable product

GL-R Series

Number included

1 cable

Cable end

M12 connector (8-pin female) - Loose wires

Length

10 m 32.81'

Material

Connector for extension: PVC/nickel-plated brass, Cable: PVC

Note

Extension cable for the GL-R Series. Use this together with the main unit connection cable (for extension).
Brown and blue: 22 AWG (nominal cross section: 0.34 mm2), other: 26 AWG (nominal cross section: 0.14 mm2)

Weight

Approx. 430 g

Keyence Stock Image
Keyence KV-LE20A Keyence
Sale price $1,162.50
Only 4 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence SJ-H108A Keyence
Sale price $2,038.05
Only 7 units left

Specifications

Model

SJ-H108A

Type

HA

Ion generation method

Corona discharge method

Structure

Shockless resistive coupling type

Voltage application method/applied voltage

Pulse AC method, ±7000 V

Ion balance control method

Dual I.C.C. method

Ion balance

±30 V *1

Operating distance

50 to 2000 mm 1.97" to 78.74"

Control input

NPN open collector or contact point signal without voltage

Control output

NPN photo relay, Maximum 100 mA max. (40 V or less)

Major functions

Condition alarm, ion level alarm, alarm output

Air purge connection port

Rc 1/8

Air purge supplied pressure

0.5 MPa or less *2

Effective length

1080 mm 42.52" *3

No. ofelectrodes

16

Static elimination bar length

1040 mm 40.94"

Rating

Power voltage

24 VDC to 36 VDC ±10%

Current consumption

500 mA (at 24 V), 350 mA (at 36 V)

Overvoltage category

I

Pollution degree

2

Environmental resistance

Ambient temperature

0 to +40°C 32 to 104°F

Relative humidity

35 to 85% RH (no condensation)

Material

Electrode probe

Tungsten

Main unit

ABS/PC

Weight

Static elimination bar

1200 g 42.33 oz

*1 Measured under the following conditions.
Installation distance: 300 mm 11.81" (22 Hz), 600 mm 23.62" (10 Hz), 1500 mm 59.06" (1 Hz)
Operating ambient temperature: 0 to +40°C 32 to 104°F
Operating ambient humidity: 35 to 65% RH
* 0.3 m/s 1.3'/s downflow
*2 Contact KEYENCE when using the air purge function with intermittent air supply.
*3 Effective length is for static elimination range when installation distance is 50 mm 1.97".

keyence Stock Image
Keyence VS-C500MX Keyence
Sale price$0.00
Sold Out

Specifications

Model

VS-C500MX

Storage

Internal storage

7 GB

microSD card (external)

Max. 64 GB *1

Image sensor

Image size

2/3"

Pixel size

3.45 μm 0.14 Mil

Frame rate

55 fps

Lens

Mount

C-mount

I/O connection

Number of inputs

1 (insulated)

Number of outputs

3 (insulated)

Number of inputs/outputs

2 (insulated) (input and output switched via settings)

I/F

Ethernet

PoE IEEE 802.3at, M12 X cable × 1

I/O

1 In/3 Out/2 In, Out M12 A cable × 1

Lighting interface

Dedicated lighting connection interface × 1

External media

microSD card slot × 1

Functions

Output image pixels

2448 × 2048

Exposure time

0.015 msec to 1000 msec

Image correction functions

Gain, Offset, Gamma correction, White balance, Fine HDR

Indicators

OLED display, Status LED, Ethernet LED (LINK/ACT), SD card access indicator

Buttons

Operation buttons × 3

Installation support functions

Angle monitor

Power supply

Power voltage

24 V +25%/−20% or PoE (IEEE802.3at Power Class 4)

Current consumption (camera only)

0.97 A, 18.7 W (for 19.2 V)/0.78 A, 18.7 W (for 24 V)

Current consumption (including lighting)

4.7 A, 89.7 W (for 19.2 V)/3.8 A, 89.7 W (for 24 V)

Current consumption (With CA-DEx10X connected)

11.3 A, 216.7 W (for 19.2 V)/9.1 A, 216.7 W (for 24 V) *2

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.05 G2/Hz; X, Y, and Z directions, 0.5 hours (IEC60068-2-64)

Shock resistance

50 G, 3 times in each of the 6 directions (IEC60068-2-27)

Size (H×W×D)

93.2 mm × 52.6 mm × 66 mm 3.67" × 2.07" × 2.60"

Case temperature

0°C to 65°C 32 to 149°F *3

Standard certifications

CE, FCC, NRTL, KC, UKCA

Material

Case: Aluminum die-casting, Front cover: Glass *4

Weight

Approx. 420 g 14.83 oz

*1 Using the configuration software, format the media before use.
*2 Maximum instantaneous current. Average current is below current consumption (including lighting).
*3 Reference - Case temperature 65°C 149°F with 200 mm × 200 mm × 10 mm 7.87" × 7.87" × 0.39" aluminum board and at ambient temperature of 40°C 104°F.
*4 ESD-Safe, IEC61340-5-1 compliant.

keyence Stock Image
Keyence BT-W100GA Keyence
Sale price$0.00
Sold Out

Specifications

Model

BT-W100GA

Type

Laser Type

Controller

CPU

ARM Cortex®-A8 (800MHz)

OS

Microsoft® Windows® Embedded Compact 7

Main Memory

RAM

256 MB

ROM

512 MB

Display

Screen

Type

3.5 inch transmissive TFT LCD (Vertically Aligned)

Resolution

480 × 640 (VGA)

Color

65,536 colors

Backlight

Super luminosity white LED

Operation status LED

Tri-color LED (red, green, blue, yellow, cyan, magenta and white)

Operations

Touch Panel

Analog resistance film (hardened glass)

Keyboard

Type

26 keys

Backlight

LED (orange)

Scanner

Reading
Specification

Reading Light
Source

Visible light semiconductor laser (655 nm)
Output 1.0 mW
Class 2 Laser Product (IEC60825-1) *1

Pointer Light
Source

-

Scan Count

100 scans/second

Minimum
Resolution

0.127 mm 0.01"

Reading
Distance

62 to 542 mm 2.44" to 21.34"
(narrow bar width 1.0 mm 0.04")
42 to 222 mm 1.65" to 8.74"
(narrow bar width 0.25 mm 0.01")

Reading Width
(Field Range)

-

PCS

0.45 or more
(reflection rate of space part 70% or more)

Supported Code

JAN/EAN/UPC (add-on code compatible), CODE128, GS1-128, CODE39, NW-7(Codabar), CODE93, ITF, Industrial2of5, COOP2of5, GS1 DataBar

Wireless
Communication

Wireless
LAN

Wireless Radio

IEEE802.11a/b/g/n

Frequency Range

2.4 GHz (b/g/n: 1 - 11 ch), 5 GHz(a/n: W52, W53, W56, W58), W52 can only be used indoors.

Distance

Indoors: 100 m 328.1' of vision

Security

Security: WEP(64/128bit)/WPA/WPA2, WPA encryption: TKIP/AES, Authentication: WPA(2)-PSK / TLS / PEAP /TTLS / LEAP / EAP-FAST

Bluetooth

Wireless Standard

Bluetooth® V2.1 +EDR

Supported Profile

SPP, PAN(PANU), FTP(Client), HSP(AG), HID(Host/Device)

Distance

Approx. 10 m 32.8'

Expansion
Slot

Supported Media

microSD/SDHC card

Capacity

Up to 32 GB

Power
Source

Main
Battery

Type

Rechargeable, removable Lithium ion battery pack

Capacity

2450 mAh

Continuous usage time

Approx. 19 hours *2*3

Charging Time

Approx. 4.5 hours (at room temperature)

Backup
battery

Clock

Approx. 6 months *4*3

RAM data

Approx. 3 minutes *4*3

Others

Buzzer

Musical tones: 16 tones, Volume: 3 levels

Vibration function

Enable

Clock Accuracy

± 80 seconds per month (at room temperature)

Environmental resistance

Enclosure rating

IP54 (IEC60529)

Ambient temperature

-20 to +50 °C -4 to 122 °F (No freezing)*5

Relative humidity

20 to 85 % RH (No condensation)

Storage temperature

-20 to +60 °C -4 to 140 °F (No freezing)

Storage relative humidity

20 to 85 % RH (No condensation)

Drop Resistance

1.5 m 5.0' (multiple drops to concrete)*3

Accessory

Hand Strap Back Cover, Wrist strap, Stylus pen

Dimensions

170 × 79 × 36.1 (31.3) mm
6.69" × 3.11" × 1.42" (1.23")
(grip thickness)

Weight

259 g (with battery pack)

*1 The laser classification for FDA (CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.
*2 This indicates the case when barcodes are read once per 20 seconds and round trip wireless communication is made at room temperature with the operation status LED, vibration function OFF, the buzzer ON (low volume), the backlight ON (brightness 1) and the charging mode2.
*3 This is a typical value at room temperature, but not a guaranteed value.
*4 This indicates the case when the main battery is not attached or the battery level is low, and operations are performed at room temperature.
*5 Replace the main battery at a temperature of -5 °C 23 °F or higher. The product may not start in low-temperature environments.

keyence Stock Image
Keyence OP-88621 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence XG-E700 Keyence
Sale price $883.22
Only 9 units left
Buy the Keyence XG-E700 - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence XG-E700 is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence OP-88751 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence LS-3101 Keyence
Sale price $610.50
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence MP-FCBF20 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence New Stock Image
Keyence CA-DRW10X Keyence
Sale price $942.30
Only 9 units left

Specifications

Model

CA-DRW10X

Type

High-Intensity LumiTraxTM Light

LED color

White

Power consumption

40.5 W (during normal light emission)

Weight

Approx. 240 g

Keyence Stock Image
Keyence GL-R48HG Keyence
Sale price $1,429.64
Only 5 units left
Buy the Keyence GL-R48HG Encoder - a precision rotary or linear position feedback device for motion control and positioning. Features high-resolution output, rugged construction, and standard interface protocols. The Keyence GL-R48HG is a direct replacement for existing encoder installations.
Keyence New Stock Image
Keyence IV3-G600CA Keyence
Sale price $2,277.91
In stock, 14 units

Specifications

Model

IV3-G600CA

Type

Wide view

Installed distance

50 mm 1.97" or more *1

Field of view

Installed distance 50 mm 1.97": 51 (H) × 38 (V) mm 2.01" (H) × 1.50" (V)
Installed distance 3000 mm 118.11": 2730 (H) × 2044 (V) mm 107.48" (H) × 80.47" (V)
(typical example)

Image receiving element

Type

1/2.9 inch color CMOS

Number of pixels

1280 (H) × 960 (V)

Focus adjustment

Auto *2

Exposure time

12 μs to 9 ms

Lights

Illumination

White LED

Lighting method

Pulse /continuous lighting is switchable.

Indicators

2 (the same display details for both indicators)

Environmental resistance

Enclosure rating

IP67 *3

Ambient temperature

0 to +50°C 32 to 122°F (No freezing) *4

Relative humidity

35 to 85% RH (No condensation)

Vibration resistance

10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions *5

Shock resistance

500 m/s2 1640'/s2, 3 times in each of the 6 directions *5

Material

Main unit case: Zinc die-casting, Front cover: Acrylic, Operation indicator cover: TPU

Weight

Approx. 75 g 2.65 oz (without the AI Lighting unit)
Approx. 225 g 7.94 oz (with the AI Lighting unit)

*1 Removing the polarizing filter is recommended when used at distances of 3 m 9.8' or more.
*2 The focus position can be automatically adjusted at the time of installation. This function is deactivated during operation. A different focus position can be registered for each program.
*3 Except when the polarizing filter (OP-88642/OP-88643/OP-88646/OP-88647) is mounted.
*4 For situations where the operating ambient temperature will exceed 40°C 104°F, follow KEYENCE’s specified heat dissipation measures to ensure the case temperature does not exceed the rated maximum temperature (65°C 149°F). Check the instruction manual for more information.
*5 Except when the dome attachment (IV2-GD05/IV2-GD10) is mounted.

Keyence Stock Image
Keyence GL-SP2N Keyence
Sale price $1,022.07
Only 1 unit left

Specifications

Model

GL-SP2N

Type

Standard cable

Applicable product

GL-S Series main unit

Number included

1 (set includes transmitter and receiver)

Cable end

Main unit connection connector - Loose wires

Output

NPN

Number of core

6

Length

2 m 6.56'

Note

For use with wire synchronization and optical synchronization systems

Weight

120 g

keyence Stock Image
Keyence OP-89090 Keyence
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence GL-R31F Keyence
Sale price $841.91
In stock, 11 units

Specifications

Model

GL-R31F

Detection capability

ø0.55" ø14 mm

Total length

12.60" 320mm

No. of beam

31

Detection height

11.81" 300mm

Protection height

12.76" 324mm

Beam axis spacing/Lens diameter

10 mm 0.39" / ø4 ø0.16"

Detecting distance

0.66 to 32.81' 0.2 to 10 m*1

Effective aperture angle

Max. ±2.5° (When operating distance is 9.84' 3 m or more)

Light source

Infrared LED (870 nm)

Response time (OSSD) (ms)

Wire synchronization, One-line or
Optical synchronization system (Channel 0)

ON→OFF

7.8

OFF→ON

50.5*2

All blocked→ON

67.9*3

Optical synchronization system
(Channel A or B)

ON→OFF

10.7

OFF→ON

54.8*2

All blocked→ON

79.5*3

Detection mode

Turns on when no interruptions are present in the detection zone

Synchronization between the transmitter and receiver

Optical synchronization or Wire synchronization (Determined by wiring)

Light interference prevention function

Prevents mutual interference in up to two GL-R systems.
Optical synchronization: prevented by Channel A and B with setting switch
Wire synchronization: prevented automatically

Control output
(OSSD output)

Output

2 transistor outputs. (PNP or NPN is determined by the cable type)

Max. load current

500 mA*4

Residual voltage (during ON)

Max. 2.5 V (with a cable length of 16.40' 5 m)

OFF state voltage

Max. 2.0 V (with a cable length of 16.40' 5 m)

Leakage current

Max. 200 µA

Max. capacitive load

2.2 µF

Load wiring resistance

Max. 2.5 Ω

Supplemental output
(Non-safety-related output)

AUX

transistor outputs. (PNP or NPN is determined by the cable type)
Load current: Max. 50 mA, Residual voltage: Max. 2.5 V (with a cable length of 16.40' 5 m)

Error output

Muting lamp output

Incandescent lamp (24 VDC, 1 to 5.5 W)
LED lamp (load current: 10 to 230 mA) can be connected.

External input

When using a PNP output cable

EDM input
Wait input
Reset input
Muting input 1, 2
Override input

ON voltage: 10 to 30 V
OFF voltage: Open or 0 to 3 V
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

When using an NPN output cable

ON voltage: 0 to 3 V
OFF voltage: Open or 10 V or more
Up to the power voltage
Short circuit current: Approx. 2.5 mA (Approx. 10 mA with EDM input only)

Power supply

Power voltage

24 VDC ±20%, ripple (P-P) 10% or less, Class 2

Current
consumption
(Max.) (mA)

Transmitter

54

Receiver

71

Protection circuit

Reverse current protection, short-circuit protection for each output, surge protection for each output

Approved standards

EMC

EMS

IEC61496-1, EN61496-1, UL61496-1

EMI

EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA

Safety

IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE)
IEC61496-2, EN61496-2, UL61496-2 (Type 4 AOPD)
IEC61508, EN61508 (SIL3), IEC62061, EN62061 (SIL CL3)
EN ISO13849-1:2015 (Category 4, PLe)
UL508
UL1998

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Overvoltage category

II

Ambient light

Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less

Operating ambient temperature

-10 to +55 °C 14 to 131 °F (No freezing)

Operating relative humidity

15 to 85 % RH (No condensation)

Storage temperature

-25 to +60 °C -13 to 140 °F (No freezing)

Storage relative humidity

15 to 95 % RH

Vibration resistance

10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions

Shock resistance

100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions

Material

Main unit case

Aluminum

Upper case/lower case

Nylon (GF 30%)

Front cover

Polycarbonate, SUS304

Weight

Transmitter

430 g

Receiver

440 g

*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m.
*2 If the interruption is present in the detection zone for less than 80 ms, the response time (OFF to ON) will be 80 ms or more to ensure that the OSSD maintains the OFF state for more than 80 ms.
*3 “All blocked” means the situation where the GL-R operates in optical synchronization system and the
transmitter and receiver is not synchronized (top and bottom beam axes are both blocked). In this situation,
the response time is longer because the GL-R synchronizes the transmitter and receiver fi rst and then
determines the clear or blocked.
*4 When the GL-R is used under surrounding air temperatures between 50 to 55°C 122°F to 131°F, the Maximum load current should not exceed 350 mA.

Recently viewed