Specifications
Model |
GV-H130 |
|||
Type |
Mid-range |
|||
Light source |
Visible semiconductor laser, Wavelength: 655 nm |
|||
Laser class |
FDA (CDRH) |
Class 2 (560 µW) |
||
IEC 60825-1 | ||||
JIS C6802 | ||||
Detection distance |
55 to 130 mm 2.17" to 5.12" |
|||
Possible display range |
768 to -98 |
|||
Standard detection deviation |
1 mm 0.04" |
|||
Spot diameter |
Approx. ø0.3 mm ø0.012" |
|||
Operation status indicators |
Control output: Red LED/Laser radiation emission indicator: Green LED/1 spot indicator: Green LED |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Operating ambientluminance |
Incandescent lamp |
10000ℓx |
||
Sunlight |
20000ℓx |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing material: PBT, Display: Polyarylate, Metal: SUS304, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 130 g*2 |
|||
*1 General guideline for amplifier display values relative to detection distance (when distance display mode is set to normal). | ||||

Specifications
Model |
IV4-400MA |
|||
Type |
Narrow field of view model |
|||
Installed distance |
From 400 mm 15.75" *1 |
|||
Tools |
Available modes |
Standard Mode, Sorting Mode, AI Through Count Mode |
||
Tool with standard mode |
Standard/Sorting Modes: AI Differentiate, Outline, ColorArea *2, Area *3, EdgePixels, ColorAverage *2, Brightness Avg *3, Width, Diameter, Edge Presence, Pitch, |
|||
Number of tools |
65 tools *4 |
|||
Field of view |
Installation distance 400 mm 15.75": 58 (H) × 44 (V) mm to |
|||
Switch settings (programs) |
128 programs (with SD card)/32 programs (without SD card) |
|||
Image receiving element |
Type |
1/2.9 inch monochrome CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Image history |
Number of storable images |
100 images *5 |
||
Save conditions |
Logging Settings 1: NG only/OK near NG threshold *6/All – selectable. Logging Settings 2: Manually configured number before/after NG/Fixed interval – selectable *5 |
|||
Focus adjustment |
Auto *7 |
|||
Image data transfer |
Transfer destination |
microSD card/FTP server/SFTP server – selectable |
||
Transfer format |
BMP/JPEG/iv4p/txt: Selectable, file name can be changed |
|||
Transfer conditions |
OK/NG/NG and OK near threshold *6/OK near threshold *6/All/Judgment Complete – selectable |
|||
Exposure time |
12 μs to 10 ms *8 |
|||
Analysis information |
RUN display |
Tool-specific list (judgment results, match, match bar display) *9 |
||
RUN information |
Switchable between OFF/histogram/processing time/count/output monitor |
|||
Lights |
Illumination |
Infrared LED |
||
Lighting method |
Pulse lighting |
|||
Other functions |
Image capture function |
Digital zoom (×2, ×4), HDR, high gain, color filters *2, white balance *2, brightness correction, Smart Image Optimization, preliminary capture, trapezoidal shape correction, mirror inversion correction |
||
Tool functions |
Additional Learning (AI Differentiate, AI Identify, AI OCR, AI Count, AI Trigger. AI Through Count Mode: Count), remove outline, masking function, color extraction/exclusion *2, color histogram function *2, monochrome histogram function *3, scaling function |
|||
Utilities |
List of NG sensor occurrences, NG hold, test run, I/O monitor, security settings (2-step password, Enhanced Security Mode), simulator *10, adding FTP image information, multiple position adjustment, adding multiple masters, |
|||
Indicators |
OUT, TRIG, STATUS, LINK/ACT, SD |
|||
Input |
Type |
Switchable between non-voltage input/voltage input |
||
Number of inputs |
6, 3 of which are selectable between IN/OUT |
|||
Function |
IN1: External trigger. IN2, IN3, I/O1 to I/O3: Assign any desired function. |
|||
Output |
Type |
Open collector output: Switchable between NPN/PNP and N.O./N.C. |
||
Number of outputs |
6, 3 of which are selectable between IN/OUT |
|||
Function |
Assign any desired function. |
|||
Power/I/O |
Connector |
M12 12-pin A-code male connector |
||
PoE |
PoE Power Class 4/6 *12 |
|||
Ethernet |
Standard |
1000BASE-T/100BASE-TX |
||
Connector |
M12 8-pin X-code female connector |
|||
Network function |
FTP client, SFTP client, SNTP client, OPC UA server, MQTT client |
|||
Interface compatibility |
Built-in Ethernet |
EtherNet/IP, PROFINET CC-B *13, TCP/IP Nonprocedural Comm (×2 connections) |
||
Communication unit (IV4-CU1) |
PROFINET CC-C *14, EtherCAT® |
|||
Expanded memory |
microSD card (microSD/microSDHC) *15 |
|||
Power supply |
Power voltage |
24 V +25%, -20% (including ripple) *16 |
||
Power consumption |
3.4 A or less (at 19.2 V), 2.7 A or less (at 24.0 V)(no AI imaging illumination unit; with communication unit; includes 120 mA output load) |
|||
Average power consumption |
9.3 W (without AI imaging illumination unit) |
|||
Environmental resistance |
Enclosure rating |
IP67 *18 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *19 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions *20 |
|||
Material |
Main unit case: Aluminum die-casting. Front cover: Acrylic (hard coating). Back plastic cover and plastic lid: PBT. Operation indicator cover: TPU. |
|||
Weight |
Approx. 370 g 13.06 oz (no AI imaging illumination unit) |
|||
*1 If using at 3 m 9.8' or more, it is recommended that the polarizing filter be removed before use. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
PR-F51C3PD*1 |
|||
Type |
Thrubeam |
|||
Output |
PNP |
|||
Shape |
Flat |
|||
Cable connection |
M8 connector (3 pin) |
|||
Detection distance |
0.6 m |
|||
Number of control outputs |
1 output |
|||
Output operation |
Output 1 |
Dark-ON |
||
Output 2 |
- |
|||
Response time |
Output 1 |
0.5 ms |
||
Output 2 |
- |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
- |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
- |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including 10 % ripple (P-P) |
||
Current consumption |
Transmitter: 11 mA, Receiver: 16 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 20 g |
|||
*1 The M8 connector (3 pin) type has 1 control output. If "D" is at the end of the part number, the sensor is equipped with a Dark-ON output. If "L" is at the end of the part number, the sensor is equipped with a Light-ON output. Example: The PR-M51C3PL has a Light-ON output. | ||||



Specifications
Model |
TH-110 |
|||
Type |
Detecting small metallic objects |
|||
Minimum detectable object |
3.0 mm |
|||
Detecting area |
100 mm |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 1.2 kg |
|||
*1 Data obtained with the amplifi er set at maximum sensitivity when target was travelling at 500 mm 19.69". | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV2-C10B |
|||
Type |
Motor power cable, Standard |
|||
Length |
10 m 32.8' |
|||
Note |
for 200 W / 400 W motor |
|||

Specifications
Model |
OP-6250 |
|||
Type |
Securing Ring |
|||
Applicable product |
FS2-60/62/65 |
|||
Note |
When using the FS2-60/62/65, this adapter and fixing ring are necessary to install the fiber unit. |
|||


Specifications
Model |
OP-88149 |
|||
Power source |
Rated input |
100 to 240 VAC 50/60 Hz |
||
Rated output |
16 VDC, Max. 3.75 A |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Storage temperature |
-20 to +80 °C -4 to 176 °F |
|||
Weight |
Approx. 250 g |
|||



Specifications
Model |
SJ-M021G |
|||
Type |
Static Elimination Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Static elimination time |
0.5 sec max.*1 |
|||
Ion balance |
±15 V or less*2 |
|||
Supply pressure range |
0.001 to 0.5 MPa*3 |
|||
Min. air pressure |
With SJ-ML |
0.02 MPa (20 Nl/min) |
||
With SJ-MS/ML1 |
0.03 MPa (20 Nl/min) |
|||
With SJ-MS/ML2 |
0.02 MPa (20 Nl/min) |
|||
With SJ-MS/ML3 |
0.08 MPa (50 Nl/min) |
|||
With SJ-MS/ML4 | ||||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +80 °C 32 to 176 °F*4*5 |
||
Relative humidity |
35 to 65 % RH |
|||
Weight |
Approx. 600 g |
|||
*1 At installation distance 50 mm 1.97", air flow 60 Nl/min (ambient temperature 20 to 30 °C 68 to 86 °F, relative humidity 40 to 60 %) | ||||

Specifications
Model |
PR-G51C3PD |
|||
Type |
Thrubeam |
|||
Shape |
Rectangular |
|||
Output |
PNP |
|||
Cable connection |
M8 connector (3 pin) |
|||
Detecting distance |
30 m 98.43' |
|||
Number of control outputs |
2 (Dark-ON +Light ON)*1 |
|||
Output operation |
Output 1 |
Dark-ON |
||
Output 2 |
― |
|||
Response time |
1 ms |
|||
Sensitivity adjustment |
One-turn trimmer (230°) |
|||
Spot diameter |
― |
|||
Light source |
4 elements, Red LED (631 nm) |
|||
Light interference prevention function |
― |
|||
Indicator lamp |
Transmitter: power supply indicator (green) |
|||
Control output |
PNP open collector |
|||
Stop emission input |
Non-voltage input |
|||
Protection circuit |
Protection against reverse power connection, power supply surge, output overcurrent, output surge, and reverse output connection |
|||
Rating |
Power voltage |
10 to 30 VDC, including Ripple (P-P) 10 % |
||
Power consumption |
Transmitter: 450 mW max. |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250)*2 |
||
Insulation resistance |
20 MΩ or more (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less |
|||
Ambient temperature |
-20 to +70 °C -4 to 158 °F (No freezing)*3 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-20 to +70 °C -4 to 158 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS 316L, |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 55 g |
|||
*1 For the threaded mount type sensors, the outputs are 1 NPN output and 1 PNP output. | ||||


Specifications
Model |
OP-88062 |
|||
Type |
Speed Controller (Low stress) |
|||
Overview |
For adjusting the air for air push type. Adjusts the spindle extension speed. |
|||
Applicable product |
GT2-PA12KL/PA12L |
|||
Number included |
1 |
|||
Weight |
Approx. 0.6 g |
|||

Specifications
Model |
SZ-P10NS |
|||
Type |
Output Cable, NPN |
|||
Applicable product |
SZ-01S |
|||
Length |
10 m 32.81' |
|||
Weight |
Approx. 530 g |
|||

Specifications
Model |
FD-R125 |
|||
Supported pipe diameter |
4" (100 A), ø100 to ø127 3.94" to 5.00" |
|||
Supported pipe materials |
Metal / resin*1 |
|||
Supported fluids |
Various liquids (i.e. water, oils, chemicals)*1 |
|||
Supported fluid temperature |
- 20 to + 120°C - 4.0 to + 248 °F (no freezing on the pipe surface)*2 |
|||
Maximum rated flow |
Rated flow velocity range: 5.0 m/s |
|||
Zero cut flow rate |
Zero cut: 0.3 m/s (default)*3 |
|||
Display method |
Dual row, 5-digit display with white, 14-segment LED; Large status indicator; Output indicators; Stability indicator; Unit indicator |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
1 (L / min) |
|||
Response time |
0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s (variable) |
|||
Measurement accuracy |
Between 20 and 100% of F.S. : ±2.0% of RD*4*5 |
|||
Protection circuit |
Power supply reverse connection protection, Power supply surge protection, Short-circuit protection for each output, Surge protection for each output |
|||
Zero point error |
±0.5% of F.S.*4*6 |
|||
Hysteresis |
Variable |
|||
Flow units |
L / min, m3 / h, gal / min |
|||
Integrated flow unit display |
1 / 10 / 100 / 1000 / 10000 (L) |
|||
Pipe temperature measurement accuracy |
±3°C ±5.4°F (liquid temperature of - 20 to + 50°C, - 4 to + 122°F) |
|||
Wiring specifications |
Power supply |
DC power supply: M12 4-pin connector / AC power supply: M4 screw terminal block (selectable) |
||
I/O |
When using a DC power supply: M12 4-pin connector / when using an AC power supply: M3 screw terminal block |
|||
Input/Output (Selectable) |
Output (ch.1/ch.2) |
Control output / Integrated pulse output / Error output / Temperature alarm, NPN / PNP setting switchable,open collector output 30 VDC or less, max. 100 mA / ch., residual voltage: 2.5 V or less*7 |
||
Analog output (ch.1/ch.2) |
Flow rate analog output / Temperature analog output and 4 - 20 mA / 0 - 20 mA (selectable), load resistance: 500 Ω or less*7 |
|||
External input (ch.2) |
Integrated flow reset input / Flow rate zero input / Origin adjustment input (selectable), short-circuit current: 1.5 mA or less, input time: 20 ms or more*7 |
|||
Rating |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 / 100 to 240 VAC - 15% or + 10% (50 / 60 Hz) |
||
Current consumption |
When using a DC power supply: 200 mA or less (load current excluded), 400 mA or less (load current included) When using an AC power supply: 15 VA or less |
|||
Environmental resistance |
Enclosure rating |
IP65 / 67 (IEC60259), IP69K (ISO20653), Enclosure Type 4X (NEMA250) |
||
Ambient temperature |
- 20 to + 60°C - 4.0 to 140 °F (no freezing)*2 |
|||
Relative humidity |
5 to 90%RH (no condensation) |
|||
Vibration resistance |
10 to 55 Hz, compound amplitude 1.5 mm 0.06", XYZ axes 2 hours for each axis |
|||
Shock resistance |
100 m/s2 , 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Dimensions |
Main unit size: 218.5 mm × 66.9 mm × 70.7 mm 8.60" × 2.63" × 2.78" |
|||
Material |
Main unit |
Body: aluminum die-casting + coating / PPS, display: reinforced glass, connectors: SUS304-equivalent |
||
Unit rear |
Rubber |
|||
Upper/lower bracket |
SUS304 |
|||
Weight |
Main unit: Approx. 1.0 kg |
|||
*1 Liquid must allow for the passage of an ultrasonic pulse, as well as not contain large air pockets or excessive bubbles. Detection may be unstable due to the type and status of the pipes. | ||||