Specifications
Model |
GL-SA28F |
|||
Type |
Protection cover Flat type for 28 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S28FH |
|||
Number included |
1 |
|||
Length |
582.6 mm 22.94" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
190 g |
|||

Specifications
Model |
GL-S40SH |
|||
Type |
Slim type |
|||
Detection capability |
ø25 mm ø0.98" |
|||
Total length |
819.5 mm 32.26" |
|||
No. of beam |
40 |
|||
Detection height |
780mm 30.71" |
|||
Protection height |
826mm 32.52" |
|||
Beam axis spacing |
20 mm 0.79" |
|||
Operating distance |
0.1 to 2 m 0.3' to 6.6' |
|||
Effective aperture angle |
Max. ±3.75° (when the operating distance is 2 m 6.6') |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time(ms) |
Wire synchronization, one-line, or optical synchronization system (channel 0) |
ON→OFF |
8.7 *1 |
|
OFF→ON |
51.9 *1 *2 |
|||
All blocked→ON |
71.8 *1 *3 |
|||
Optical synchronization system (channel A or B) |
ON→OFF |
12.3 *1 |
||
OFF→ON |
57.2 *1 *2 |
|||
All blocked→ON |
85.8 *1 *3 |
|||
OSSD operation |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or wire synchronization |
|||
Light interference prevention function |
Optical synchronization: prevented by Channel A and B with setting switch |
|||
Control output (OSSD output) |
Output type |
2 transistor outputs |
||
Max. load current |
Max. 300 mA |
|||
Residual voltage (when ON) |
Max. 2.5 V (with a cable length of 5 m 16.4') |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 5 m 16.4') |
|||
Leakage current |
Max. 200 µA |
|||
Max. load capacitance |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Inputs 1 and 2 |
Short-circuit current: approx. 1 mA |
|||
Power supply |
Current consumption(mA) |
When the center indicator is ON |
Transmitter |
50*4 |
Receiver |
76*4 |
|||
When the center indicator is OFF |
Transmitter |
30*4 |
||
Receiver |
55*4 |
|||
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
|||
Protection circuit |
Reverse current protection, short-circuit protection and surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less, Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (no condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Polyarylate |
||
Weight |
Transmitter |
305 g |
||
Receiver |
310 g |
|||
*1 If the response time (ON to OFF) exceeds 18 ms, this unit cannot be used as a certified product based on the Chinese standard GB/T4584 “压力机用光电保护装置技术条件”. | ||||

Specifications
Model |
SJ-M070 |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa or less |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
324 mm12.756" |
|||
Total length |
380 mm14.961" |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 720 g |
|||
*1 Please make an inquiry as to the measurement condition. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SJ-H132A |
|||
Type |
HA |
|||
Ion generation method |
Corona discharge method |
|||
Structure |
Shockless resistive coupling type |
|||
Voltage application method/applied voltage |
Pulse AC method, ±7000 V |
|||
Ion balance control method |
Dual I.C.C. method |
|||
Ion balance |
±30 V *1 |
|||
Operating distance |
50 to 2000 mm 1.97" to 78.74" |
|||
Control input |
NPN open collector or contact point signal without voltage |
|||
Control output |
NPN photo relay, Maximum 100 mA max. (40 V or less) |
|||
Major functions |
Condition alarm, ion level alarm, alarm output |
|||
Air purge connection port |
Rc 1/8 |
|||
Air purge supplied pressure |
0.5 MPa or less *2 |
|||
Effective length |
1320 mm 51.97" *3 |
|||
No. ofelectrodes |
20 |
|||
Static elimination bar length |
1280 mm 50.39" |
|||
Rating |
Power voltage |
24 VDC to 36 VDC ±10% |
||
Current consumption |
500 mA (at 24 V), 350 mA (at 36 V) |
|||
Overvoltage category |
I |
|||
Pollution degree |
2 |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32 to 104°F |
||
Relative humidity |
35 to 85% RH (no condensation) |
|||
Material |
Electrode probe |
Tungsten |
||
Main unit |
ABS/PC |
|||
Weight |
Static elimination bar |
1400 g 49.38 oz |
||
*1 Measured under the following conditions. | ||||

Specifications
Model |
EH-308 |
|||
Type |
Standard , Shielded , Cylindrical |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
10 x 10 mm 0.39" x 0.39" |
|||
Stable detecting range |
0 to 2 mm0.08" |
|||
Maximum detecting distance |
5 mm0.20" |
|||
Hysteresis |
0.04 mm0.002" |
|||
Repeatability |
0.005 mm 0.0002" |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, within -10 to +60°C 14 to 140°F |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Weight |
Approx. 47 g (including 3-m 9.8' cable) |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
SV3-M200AS |
|||
General specifications |
Applicable servo amplifier |
SV3-200L2 |
||
Rated output |
1.8k W |
|||
Rated torque |
11.5 N·m *1 |
|||
Instant maximum torque |
28.7 N·m |
|||
Rated current |
16.7 Arms |
|||
Instant maximum current |
42 Arms |
|||
Rated rotation speed |
1,500 min-1 |
|||
High rotation speed |
4,000 min-1 |
|||
Torque constant |
0.748 N·m/Arms |
|||
Rotor moment of inertia |
26.0 ×10-4 kg·m2 |
|||
Rated power rating |
50.9 kW/s |
|||
Rated angle acceleration |
4,420 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
26 bit |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or higher) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20% to 80% RH (No condensation) |
|||
Operating atmosphere |
Indoors (No corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2,000 m 6,561.7' or less (reduced ratings at 1,000 m 3,280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8 ft/s2 with servo motor flange surface as reference (up/down, left/right) |
|||
Impact resistance |
490 m/s2 1,607.6 ft/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
Class F |
|||
Min. insulation resistance |
500 VDC 10 MΩ or more with insulation resistance meter |
|||
Isolation voltage tolerance |
1,500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5× |
|||
Approx. weight |
8.6 kg 18.96 lb |
|||
*1 50 W to 750 W rated torque is continuously allowable with an ambient temperature of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W/100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||


Specifications
Model |
SZ-P20NS |
|||
Type |
Output Cable, NPN |
|||
Applicable product |
SZ-01S |
|||
Length |
20 m 65.62' |
|||
Weight |
Approx. 1,040 g |
|||

Specifications
Model |
GL-SS5 |
|||
Type |
Standard cable |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
1 |
|||
Cable end |
Main unit connection connector - Main unit connection connector |
|||
Length |
5 m 16.40' |
|||
Note |
Use this with one-line systems and series connections. |
|||
Weight |
150 g |
|||


Specifications
Model |
SV2-M040AK |
|||
General specifications |
Applicable servo amplifier |
SV2-040L2 |
||
Rated output |
400 W |
|||
Rated torque |
1.27 N·m *1 |
|||
Instant maximum torque |
4.46 N·m |
|||
Rated current |
2.5 Arms |
|||
Instant maximum current |
9.3 Arms |
|||
Rated rotation speed |
3000min-1 |
|||
High rotation speed |
6000 min-1 |
|||
Torque constant |
0.544 N·m/Arms |
|||
Rotor moment of inertia |
0.486 ×10-4kg·m2 |
|||
Rated power rating |
33.1 kW/s |
|||
Rated angle acceleration |
26100 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
UL: phase A, CE: phase B |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
10 × |
|||
Approx. weight |
1.1 kg |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
MD-F3100C |
|||
Type |
30 W type standard area type main unit (controller + head) |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-Axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: fiber laser, Class 4 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
||
Wavelength |
1090 nm |
|||
Output |
30 W |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
|||
Marking area |
120 x 120 x 42 mm 4.72" x 4.72" x 1.65" |
|||
Standard working distance (±variable width) |
168 mm (± 21 mm) 6.614"(± 0.827") |
|||
Marking resolution |
2 µm 0.08 Mil |
|||
Scan speed |
12000 mm 472.44"/s max. |
|||
Character type |
Font |
KEYENCE original font (numerical value, alphabet, katakana, hiragana, and kanji)/user font/true type font |
||
Barcode |
CODE39/ITF/2of5/NW7 (CODABAR)/JAN/EAN/UPC/CODE128 |
|||
2D code |
QR code/micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar Truncated/GS1 DataBar Truncated CC-A/GS1 DataBar Stacked/GS1 DataBar Stacked CC-A/GS1 DataBarLimited/GS1 DataBar Limited CC-A |
|||
Logo image |
Custom font, logo (CAD) data BMP/JPEG/PNG/TIF |
|||
Machinery operation |
Fixed point/straight line/dashed line/oval |
|||
Marking conditions |
Workpiece style |
Stationary marking/movement marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 120 mm 0.003" to 4.72" |
|||
No. of registered programs |
2000 settings max. |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O, contactor control I/O |
|||
Interface |
RS-232C, RS-422A, USB 2.0,*2 Ethernet (100BASE-TX/10BASE-T) |
|||
CF memory card slot |
Compact flash memory card*3 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4m |
|||
Cooling method |
Controller: forced air cooling, head: natural air cooling |
|||
Rated voltage and power consumption |
Single-phase 100 to 120/200 to 240 VAC ±10 %, 50/60 Hz, Max. 550 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 27.0 kg |
|||
*1 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA [CDRH] Laser Notice. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
KV-XL202 |
|||
Type |
Serial communication unit |
|||
Communication standard |
RS-232C |
|||
Connection interface |
European terminal block with 7 poles (detachable) × 2 ports |
|||
Transmission specifications |
Electrical termination (terminator) |
- |
||
Transmission rate |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps |
|||
Transmission method |
Full duplex |
|||
Data format |
Start bit: 1 bit |
|||
Error detection |
Parity: Even, odd, none |
|||
RS/CS flow control |
ON or OFF |
|||
Transmission distance |
15 m 49.2' |
|||
Number of transmission units |
1 |
|||
Connectable CPU unit |
KV-X Series/KV-8000A |
|||
Refresh |
Automatic refresh, direct refresh, inter-unit synchronization refresh |
|||
Serial communication functions |
Non-procedure, PROTOCOL STUDIO, Modbus slave, etc. |
|||
Serial communication function execution methods |
Ladder program, unit program (flow) |
|||
Unit program capacity |
3 MB (Max. number of blocks: Approx. 20000) |
|||
flow |
Max. number of flows |
256 |
||
Number of simultaneous activities |
Unlimited |
|||
Flow |
Internal data Memory |
524288 words |
||
PROTOCOL STUDIO |
Transmission method |
Cyclic communication: Tx + Rx, Tx only, Rx only |
||
Max. number of connected devices |
2 |
|||
Max. number of communication commands |
48/96*1 |
|||
Maximum number of total frames |
Rx: 48/96*1 × 16; |
|||
Max. number of compared received frames |
16 per command |
|||
Maximum number of block elements |
96 per frame |
|||
Transmission data length |
1 to 2048 bytes per frame |
|||
Reception data length | ||||
PLC link |
Communication patterns |
Write, read, transfer |
||
Number of link settings |
512 settings max.*2 |
|||
Link data size |
1440 words max. per setting (bit: 720 words, word: 720 words) |
|||
Data unit |
1 word |
|||
Number of connected models |
2 models max. (1 model × 2 ports) |
|||
Number of connected units |
2 max. (1 unit × 2 ports) |
|||
Trigger types |
Cyclic/event (64 settings max. for event*2) |
|||
Update interval |
10 to 65535 ms |
|||
Internal current consumption |
140 mA or less |
|||
Weight |
Approx. 200 g |
|||
*1 The max. is 48 when “Standard” is set for the number of communication commands in Unit Editor and 96 when “Extended” is set. | ||||

Specifications
Model |
CA-DC60E |
|||
Type |
Lighting power supply |
|||
Output |
Light control method |
Constant current control mode |
||
Intensity range |
1,024-step digital gradation (switchable settings using controller) |
|||
Connection points |
2ch (Dedicated 12-pole connector) |
|||
Synchronization |
Camera trigger and shutter synchronization*1 |
|||
Response speed |
1 ms or less |
|||
Display |
LED display |
Power / Lighting status (2ch each) |
||
Rating |
Power voltage |
24 VDC +25%, -20% |
||
Current consumption |
5.7A (at 19.2VDC)/4.6A (at 24VDC) *2 |
|||
Environmental resistance |
Ambient temperature |
0 to 45°C 32 to 113°F (DIN rail-mounted) / 0 to 40°C 32 to 104°F (bottom-mounted) *3 |
||
Relative humidity |
85%RH or less (No condensation) *3 |
|||
Weight |
Approx. 500 g |
|||
*1 Continuous lighting (single-color lighting in all directions) can only be set when the brightness value control is set to ON. | ||||

Specifications
Model |
ED-118U |
|||
Type |
Non-shielded |
|||
Shape |
M18Threaded type |
|||
Detecting distance |
11 mm 0.43" ±15% |
|||
Detectable object |
All metals *1 |
|||
Standard target (aluminum, t=1 mm 0.04") |
50 x 50 mm 1.97" |
|||
Hysteresis |
15% max. of detecting distance |
|||
Response frequency |
200 Hz |
|||
Operation mode |
N.O. |
|||
Indicator lamp |
Operation indicator: Red LED, Stable operation indicator: Green LED |
|||
Temperature characteristics |
±20% max. of detecting distance at 23°C 73.4°F, within 0 to 50°C 32 to 122°F |
|||
Control output |
NPN open collector 100 mA max. (40 V max.), Residual voltage: 1 V max. |
|||
Protection circuit |
Reversed polarity, surge absorber |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
35 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Nickel-plated brass |
|||
Accessories |
Screw nut x 2, |
|||
Weight |
Approx. 140 g (including 2-m 6.6' cable and nuts) |
|||
*1 When detecting ferrous metals, the detecting distance may decrease. | ||||

Specifications
Model |
OP-84456 |
|||
Type |
30-pin MIL connector |
|||
Applicable product |
GT2-100 Series |
|||
Note |
Expansion board version sold separately, connector and contact |
|||

Specifications
Model |
AP-V42AW |
|||
Type |
Amplifier Unit, NPN |
|||
Applicable sensor head |
AP-41M, AP-41, AP-43, AP-44 |
|||
Set and display range |
-15 to +110 % of F.S.*1 |
|||
Display |
4 1/2-digit, 2-color, 7-segment LED (Character height: 4.5 mm 0.18"), AI indicator (green), Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Repeatability |
±0.2 % of F.S. |
|||
Display resolution |
AP-41M/41/44: Standard mode 0.1 inchHg, High-resolution/Focus mode 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) max., 24 V: 960 mW (40 mA) max. |
||
Eco mode |
12 V: 480 mW (40 mA) max., 24 V: 720 mW (30 mA) max. |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of FS; high-resolution/focus mode: 0.1 % of F.S.) |
|||
Response time (Chattering prevention function) |
1 (in high-speed mode only), 2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
- |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
NPN open collector 20 mA max. (at 40 V or below) with max., residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Polycarbonate |
|||
Accessories |
End Unit,Head Connector, and Expansion seal |
|||
Weight |
Approx. 80 g (with 2-m 6.6' cable) |
|||
*1 The focus range applies while in focus mode only. | ||||