Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644572525
1 piece
85362090
Dimensions
414 mm
461 mm
396.5 mm
61 kg
Container Information
1 piece
515 mm
600 mm
615 mm
73 kg
8015644572525
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
4P
215 W
1600 A
12 kV
1000 V
1600 A
690 V AC
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
1600 A
690 V
PR121/P-LI
EL
N
IEC
E2
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644573188
1 piece
85362090
Dimensions
414 mm
461 mm
396.5 mm
61 kg
Container Information
1 piece
515 mm
600 mm
615 mm
73 kg
8015644573188
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
W
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
4P
130 W
1250 A
12 kV
1000 V
1250 A
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
for 1 s 65 kA
for 3 s 50 kA
for 1 s 65 kA
for 3 s 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
1250 A
690 V
PR121/P-LSIG
EL
S
IEC
E2
Withdrawable Circuit-Breakers
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8015644573027
1 piece
85362090
Dimensions
386 mm
418 mm
302 mm
56 kg
Container Information
1 piece
515 mm
600 mm
615 mm
68 kg
8015644573027
Additional Information
SACE Emax
Air Circuit Breaker
Air Circuit Breaker
F
Technical
AC
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
Ue =< 440 V 15000 cycle
Ue = 500 ... 690 V 15000 cycle
30 cycles per hour
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
4P
70 W
1250 A
12 kV
1000 V
1250 A
690 V AC
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
for 1 s 65 kA
for 3 s 50 kA
for 1 s 65 kA
for 3 s 50 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
(220 V AC) 85 kA
(230 V AC) 85 kA
(380 V AC) 85 kA
(400 V AC) 85 kA
(415 V AC) 85 kA
(440 V AC) 85 kA
(500 V AC) 65 kA
(660 V AC) 65 kA
(690 V AC) 65 kA
1250 A
690 V
PR121/P-LSIG
EL
S
IEC
E2
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal
Certificates and Declarations
External Classifications and Standards
Q
39120000
5. Small Equipment (No External Dimension More Than 50 cm)
Main category name:Drives - Motors - Circuits Protection Sub category name:Drives - Motors - Circuits Protection Vendor:ABB