keyence Stock Image
Keyence LK-CC100 Keyence
Sale price $2,416.16
Only 1 unit left

Specifications

Model

LK-CC100

Type

CC-Link communication unit dedicated to LK-G5000 Series

Network connection

Supported CCLink version

Ver. 1.10 (Extended cyclic setting: Single) Ver. 2.00 (Extended cyclic setting: Double or more)*1*2

Master unit

CLPA-certified master unit (CC-Link Ver. 2.00/Ver. 1.10)

No. of occupied stations

1 to 4

Communication speed

156kbps、625kbps、2.5Mbps、5Mbps、10Mbps

Connection cable

Dedicated CC-Link cable supporting Ver. 1.10 (Shielded 3-core twisted-pair cable: OP-79426, OP-79427)

Maximum total cable extension length

156kbps…1200m、 625kbps…900m、 2.5Mbps…400m、 5Mbps…160m、 10Mbps…100m

Station type

Remote device station

Power supply

Power supply voltage

24 VDC ±10 % (supplied from controller)

Maximum current consumption

200mA or less

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 300 g

*1 The LK-G5000 Series supports the "extended cyclic transmission" and "station-to-station cable length relaxation" of CC-Link Ver. 2.00.
*2 CC-Link is a registered trademark of Mitsubishi Electric Corporation.

LK-G32 Keyence
Keyence LK-G32 Keyence
Sale price $1,491.33
In stock, 24 units

Specifications

Model

LK-G32

Reference distance

Diffused reflection: 30 mm 1.18", Specular reflection: 23.5 mm 0.93"

Measuring range

Diffused reflection: ±5 mm ±0.2", Specular reflection: ±4.5 mm ±0.18"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. ø30 µm ø0.0012"

Linearity

±0.05 % of F.S. (F.S.= ±5 mm ±0.2")*3

Repeatability

0.05 µm*4

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±5 mm ±0.2")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 10,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 280 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes +1.8 mm +0.07" (FAR side) to -5 mm -0.20" (NEAR side) for Diffused reflection, and +1.6 mm +0.06" (FAR side) to -4.5 mm -0.18" (NEAR side)
*3 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*4 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.

Keyence Stock Image
Keyence LK-63001P Keyence
Sale price $909.71
Only 3 units left
Buy the Keyence LK-63001P - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence LK-63001P is a direct drop-in replacement for existing installations and ships ready for integration.
Keyence New Stock Image
Keyence LR-X100 Keyence
Sale price $462.57
In stock, 12 units

Specifications

Model

LR-X100

Type

Cable Type

Detecting Distance

25.0 to 100.0 mm 0.98" to 3.94"

Standard Detectable Deviation

1.0 mm 0.04"

Display Resolution

0.1 mm 0.004"

Spot Size

Approx. 0.3 mm × 2 mm 0.012" × 0.08"
(at a detecting distance of 100 mm 3.94")

Response Time

500 µs*1/1 ms/3 ms/10 ms/200 ms Selectable

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*2)

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

NPN open collector/PNP open collector, N.O./N.C selectable.  *3
30 VDC or lower, 50 mA or lower, Residual voltage 2 V or lower

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable  *3
Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower
Input time 3 ms or more ON, 20 ms or more OFF
(25 ms or more ON, 25 ms or more OFF when External Set is selected only)

Protection Circuit

Protection against reverse power connection, protection against output overcurrent,
protection against output surge, protection against reverse output connection

Power supply

Power voltage

16 to 30 VDC (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)
ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 16000 lux or less
Sunlight: 16000 lux or less

Ambient temperature

-10°C to +50°C 14°F to + 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G) 6 times each for X, Y, and Z axes

Material

Head Case: SUS316L; Head Lens Cover: PSU
Head Gasket: FKM (lens cover), EVM (cable)
Cable: PVC
Amplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POM

Accessories

Instruction manual, laser warning label

Weight

Approx. 90 g

*1 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
*2 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.
*3 The I/O can be selected from the following combinations. Control output × 2, Control output + External input

Keyence Stock Image
Keyence LK-G3000P Keyence
Sale price $1,630.22
Only 5 units left
Buy the Keyence LK-G3000P - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence LK-G3000P is a direct drop-in replacement for existing installations and ships ready for integration.
LK-G5001PV Keyence
Keyence LK-G5001PV Keyence
Sale price $2,507.38
Only 6 units left

Specifications

Model

LK-G5001PV*1*2

Separate type

LK-G5001P/LK-HD500

Type

Main controller

Sensor head compatibility

Compatible

No. of connectable sensor heads

2

Display

Minimum display unit

LK-HD500: 0.001 µm

Display range

LK-HD500: ±999.999 µm to ±9,999.99 mm (7 settings selectable)

Display cycle

LK-HD500: Approx 10 times/sec.

Display interface

Display port

Either the display unit (LK-HD500) or dedicated touch panel (LK-HD1001) can be connected

LED indicator

LASER ON

Terminal block

Analog output voltage

±10 V output, Output impedance: 100 Ω

Analog current output

4 to 20 mA, Maximum load resistance: 350 Ω

No. of analog outputs

2

TIMING 1 input

Voltage input*3

RESET 1 input

Auto-zero 1 input

Laser control input

Voltage input*4

Laser remote input

Non-voltage input

Alarm output

PNP open-collector output

General comparator output

Expansion connector

TIMING input

Voltage input

RESET input

Auto-zero input

Program switching input

Binary selection input

Alarm output

PNP open-collector output

Comparator output

Binary output

RS-232C interface

Baud rate: 9,600 to 115,200 bps
Data length: 8 bits, Stop bit length: 1 bit, Parity: None/even/odd

USB interface

USB 2.0 Hi-Speed compliant*5

Ethernet interface

100Base-TX/10Base-T*6

EtherNet/IP™interface

Cyclic communication (implicit messaging)
Message communication (explicit messaging) : UCMM and Class3 Number of connections: 32 Complies with conformance test version CT14*7

PLC-Link

The following PLCs are supported:Mitsubishi Electric: MELSEC iQ-R Series, iQ-F Series, Q Series, L Series, FX Series
EtherNet/IP™, CC-Link, and DeviceNet® cannot be used in conjunction with PLC-Link

Head expansion unit connector

Up to 10 head expansion units can be connected to one main controller

Expansion unit connector

Either of the CC-Link unit (LK-CC100) or DeviceNet® unit (LK-DN100) can be connected

Power supply

Power supply voltage

24 VDC ±10 %

Maximum current consumption

0.6 A or less with 1 head/3.5 A or less with 12 heads

Environmental resistance

Ambient temperature

When one or less head expansion unit is connected: 0 to +50 °C 32 to 122 °F.
When two or more head expansion units are connected: 0 to +40 °C 32 to 104 °F.

Relative humidity

35 to 85 % RH (No condensation)

Weight

Approx. 600 g

*1 PNP open-collector output rating: 50 mA max. (30 V max.), Residual voltage: 0.5 V max.
Voltage input rating: Maximum input rating: 26.4 V, ON voltage: 10.2 V, OFF current: 0.6 mA
*2 Part of the input/output circuit of the LK-G5000 Series is internally common. Be careful that no potential difference is generated between the internally common terminals due to the potential difference between the cables/external devices. For details, refer to "Precautions on wiring" in the User's Manual.
*3 This input is applied to all of the synchronized OUT.
*4 When the laser class 3B sensor head is connected, a key-operated switch must be used for the input to this terminal. The laser is emitted only when the key-operated switch is set to the ON position. (Select a key which can be removed only when it is set to the OFF position.)
When the laser class 2/3R sensor head is connected, the laser turns on when this terminal is opened and turns off when it is short-circuited.
*5 When a PC supporting USB 1.1 or USB 2.0 full speed is connected, the data refresh cycle and other operations may slow down.
*6 Use the Ethernet interface only for direct connections with a PC or for local network connections with a PC or LK-G5000 Series units.
*7 The EtherNet/IP™ interface cannot be used when a CC-Link unit or a DeviceNet® unit is installed.
EtherNet/IP™ is supported by the latest controllers. For details on which controllers support EtherNet/IP™ , contact your nearest KEYENCE office.

LK-G507 Keyence
Keyence LK-G507 Keyence
Sale price $3,450.54
Only 5 units left

Specifications

Model

LK-G507

Reference distance

Diffused reflection: 500 mm 19.69", Specular reflection: 497.5 mm 19.59"

Measuring range

Diffused reflection: -250 to +500 mm -9.84" to 19.69", Specular reflection: -249 to +498 mm -9.80" to 19.61"*1*2

Light source

Type

Red semiconductor laser

Wavelength

655 nm (visible light)

Laser Class

Class II (FDA CDRH 21CFR PART1040.10)

Output

0.95 mW

Spot diameter (at reference distance)

Approx. 300 x 9,500 µm 0.0118" x 0.3740"

Linearity

±0.05 % of F.S. (±250 µm ±0.0098")*3*4 -250 to +250 mm -9.84" to +9.84"
High-accuracy range: ±0.02 % of F.S. (±100 µm ±0.0039") -250 to -50 mm -9.84" to -1.97"
Long range: ±0.1 % of F.S. (±500 µm ±0.0197") -250 to +500 mm -9.84" to +19.69" (F.S. = ±250 mm ±9.84")*5

Repeatability

2 µm 0.000079"*6

Sampling frequency

20 / 50 / 100 / 200 / 500 / 1,000 µs (Selectable from 6 levels)

LED display

Near the center of the measurement: Green lights
Within the measurement area: Orange lights
Outside the measurement area: Orange flashing

Temperature characteristics

0.01 % of F.S./°C (F.S.= ±250 mm ±9.84")

Environmental resistance

Enclosure rating

IP67 (IEC60529)

Ambient light

Incandescent lamp or Fluorescent lamp: 5,000 lux max.

Ambient temperature

0 to +50 °C 32 to 122 °F

Relative humidity

35 to 85 % RH (No condensation)

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Material

Aluminum die-cast

Weight

Approx. 380 g (including the cable)

*1 The range is obtained by measuring KEYENCE's standard target (ceramic).
*2 When the sampling rate is 20 µs, the range becomes -230 mm -9.06" (NEAR side) to -250 mm -9.84" (NEAR side) for Diffused reflection.
When the sampling rate is 20 µs, the range becomes -230 mm -9.06" (NEAR side) to -249 mm -9.80" (NEAR side) for specular reflection.
When the sampling rate is 50 µs, the range becomes -125 mm -4.92" (NEAR side) to -250 mm -9.84" (NEAR side) for Diffused reflection.
When the sampling rate is 50 µs, the range becomes -125 mm -4.92" (NEAR side) to -249 mm -9.80" (NEAR side) for specular reflection.
*3 All are calculated at F.S. = ±250 mm ±9.84".
*4 "High accuracy range" and "long range" refer to the linearity when those ranges are used.
*5 The range is obtained by measuring KEYENCE's standard target (ceramic) with the Standard mode.
*6 The range is obtained by measuring KEYENCE's standard (SUS) with 4,096 times of averaging at the reference distance.

Keyence Stock Image
Keyence LJ-S040 Keyence
Sale price $37,597.50
Only 1 unit left

Specifications

Model

LJ-S040

Reference distance

70 mm 2.76" *1

Measurement range

Z-axis (height)

±18 mm ±0.71" (F.S.=36 mm 1.42")

X-axis (width)

NEAR side

31 mm 1.22"

Reference distance

35 mm 1.38"

FAR side

39 mm 1.54"

Y-axis

Reference distance

80 mm 3.15"

XY data interval

12.5 μm 0.0005"

Number of XY data points

3200 × 6400

Light source

Laser light source

405 nm (visible light) wavelength blue semiconductor laser

Laser class

Class 2M laser product*2 (IEC 60825-1, FDA (CDRH) Part 1040.10*3)

Output

10 mW

Repeatability

Z-axis (height)

0.5 μm 0.000020" *4

XY (distance)

1 μm 0.000039" *5

Linearity

Standard area

±0.02% of F.S. *6

High-accuracy area

Imaging time

Min. 0.2 sec *7

I/F

Ethernet

1000BASE-T, 100BASE-TX

Input

LASER_ON, TRG, MEM_CLEAR *8

Output

READY, EXPOSURE_BUSY, ERROR *8

Ratings

Power voltage

24 VDC +25%, -20%

Current consumption / Power

Max. 4.0 A (at 19.2 V), 3.2 A (at 24 V) *9 / Typ. 17 W

Environmental resistance

Enclosure rating

IP65 (IEC60529) *10

Ambient light

Incandescent lamp: 10000 lux or less *11

Ambient temperature

0 to +45°C 32.0°F to +113.0°F *12

Relative humidity

85% RH or below (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.033 G2/Hz; X, Y, and Z directions (IEC 60068-2-64)

Shock resistance

15 G (IEC 60068-2-27)

Material

Aluminum

Weight

Approx. 2600 g 5.73 lb

*1 The reference distance is the distance from the bottom edge of the head to the measurement center of the Z-axis (height). See the Dimensions section for the installation reference plane.
*2 Do not view the beam directly using optical instruments (such as eye loupes, magnifiers, microscopes, telescopes, or binoculars). Observing the laser output using optical instruments is dangerous and may damage the eyes.
*3 Laser classification performed based on IEC60825-1 in accordance with FDA (CDRH) Laser Notice.
*4 The measured target is a KEYENCE standard target. Sigma value when the average height of 200 × 200 points in the center of the field of view is measured using the height tool with reciprocating imaging OFF.
*5 The measured target is a KEYENCE standard target. Sigma value when the distance between two circles of 500 points in diameter set 1000 points apart at the center of the field of view on a grayscale image is measured using the circle and circle distance tool with reciprocating imaging OFF.
*6 The measured target is a KEYENCE standard target. Value when the average height of 200 × 200 points is measured using the height tool with reciprocating imaging OFF. See the Dimensions section for the high-accuracy area reference plane.
*7 With YZ range minimum and Y skipping maximum.
*8 Laser ON input is enabled only when connected to a controller.
*9 The maximum value may be exceeded when extreme acceleration is applied.
*10 With an OP cable connected.
*11 When measuring white paper, illuminance on the sensor head receiving surface when light is applied to white paper.
*12 The head needs to be mounted to a metal plate to be used.

keyence Stock Image
Keyence LJ-GC30 Keyence
Sale price$0.00
Sold Out

Specifications

Model

LJ-GC30

Type

Cable between the head and controller

Applicable product

LK-G3000 series

Number included

1

Cable end

Straight

Length

30 m 98.42'

Weight

Approx. 2,000 g

Keyence New Stock Image
Keyence LR-ZH500C3P Keyence
Sale price $414.33
Only 8 units left

Specifications

Model

LR-ZH500C3P*1*2

Type

U.C.D. Function
Distance based laser sensor

Appearance

Rectangular

Output

PNP

Cable connection

M8 connector, 3-pin

Detectable distance

35 to 500 mm 1.38" to 19.69"(465 to 0)*3

Standard detectable deviation

35 to 180 mm 1.38" to 7.09": 9 mm 0.35"
180 to 300 mm 7.09" to 11.81": 25 mm 0.98"
300 to 400 mm 11.81" to 15.75": 40 mm 1.57"
400 to 500 mm 15.75" to 19.69": 50 mm 1.97"

Display resolution

1 to 5 (1 to 5 mm 0.04" to 0.20")

Spot size

Approx. ø3 mm ø0.12"

Response time

1.5 ms / 10 ms / 50 ms selectable

Light source

Type

Red laser (660 nm)

Laser class

Class 2 laser product (IEC60825-1)
Class II Laser product (FDA(CDRH) Part1040.10)

Function

Indicator

3-digit 7-segment display (white),
output indicator (yellow),
DATUM indicator (orange),
1 spot indicator (green)

Timer

OFF/ON delay/OFF delay/One-shot

Specifications

Power voltage

10 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS

Power consumption

450 mW or less (18 mA or less at 24 V, 34 mA or less at 12 V)

Control output

PNP Open collector,
Applied voltage 30 VDC or less, Control current 100 mA or less,
Residual voltage 1.2 V or less at 10 mA or less, 2 V or less at 10 to 100 mA

Protection circuit

Protection against reverse power connection, output overcurrent, output surge, reverse output connection

Output operation

Light-ON / Dark-ON selectable

Environmental resistance

Enclosure rating

IP68 (IEC60529), IP69K (DIN40050-9), NEMA 4X, 6P, 13 (NEMA250), ECOLAB*4, Diversey*4

Insulation resistance

20 MΩ or more (500 VDC)

Ambient light

Incandescent lamp: 10,000 lux or less
Sunlight: 20,000 lux or less at 250 mm 9.84"*5
Incandescent lamp: 2,000 lux or less
Sunlight: 4,000 lux or less at 500 mm 19.69"*5

Ambient temperature

-10 to +50 °C 14 to 122 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F (No freezing)

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, Display: PES, Lens cover: PMMA with scratch-resistant coating,
Packing/Connector ring: FKM

Accompanying items

Instruction Manual,
FDA warning/certification/identification label,
Laser warning/explanation labels

Weight

Approx. 55 g

*1 IO-Link specification v.1.1/COM2 (38.4 kbps) is supported. You can download a setup file from the KEYENCE website. If using the product in an environment in which downloading files over the internet is not possible, contact your nearest KEYENCE office.
*2 M8 connector (3-pin) type does not include the external input function.
*3 Display readings can be used as a guide for the detecting distance. When the setting value is tuned, the readout shifts. When the value exceeds "-99", "-FF" is displayed.
*4 Have passed resistance tests with cleaning agents from multiple manufactures.
*5 When the response time is 10 ms

Keyence Stock Image
Keyence LR-X50C Keyence
Sale price $495.53
Only 9 units left

Specifications

Model

LR-X50C

Type

M8 Connector Type*1

Detecting Distance

25.0 to 50.0 mm 0.98" to 1.97"

Standard Detectable Deviation

0.5 mm 0.02"

Display Resolution

0.1 mm 0.004"

Spot Size

Approx. 0.2 mm × 1.5 mm 0.008" × 0.06"
(at a detecting distance of 50 mm 1.97")

Response Time

500 µs*2/1 ms/3 ms/10 ms/200 ms Selectable

Light Source

Type

Green laser (505 nm)

Laser Class

Class 1 Laser Product (IEC60825-1, FDA (CDRH), Part1040.10*3)

IO-Link

Specification v1.1/COM2 (38.4 kbps)

Functions

Timer Function

Timer OFF/Off-delay/On-delay/One-shot/On-Off delay/On-delay One-shot

I/O

Control Output

NPN open collector/PNP open collector, N.O./N.C selectable.  *4
30 VDC or lower, 50 mA or lower, Residual voltage 2 V or lower

External Input

External Set/Laser OFF/Zero Shift/Hold Reset/Gyro Alert RST selectable  *4
Short circuit current - NPN: 1 mA or lower, PNP: 2 mA or lower
Input time 3 ms or more ON, 20 ms or more OFF
(25 ms or more ON, 25 ms or more OFF when External Set is selected only)

Protection Circuit

Protection against reverse power connection, protection against output overcurrent,
protection against output surge, protection against reverse output connection

Power supply

Power voltage

16 to 30 VDC (including 10% ripple (P-P) or less), class 2

Power consumption

During normal operation: 970 mW (38 mA or lower at 24 V, 53 mA or lower at 16 V) (Excluding Load Current)
ECO ON/ALL: 821 mW (32 mA or lower at 24 V, 44 mA or lower at 16 V) (Excluding Load Current)

Environmental resistance

Enclosure rating

IP65/IP67 (IEC60529)

Ambient light

Incandescent lamp: 16000 lux or less
Sunlight: 16000 lux or less

Ambient temperature

-10°C to +50°C 14°F to + 122°F (no freezing)

Relative humidity

35 to 85% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power Spectral Density: 0.816 G2/Hz for X, Y and Z axes

Shock resistance

1000 m/s2 (100G) 6 times each for X, Y, and Z axes

Material

Head Case: SUS316L; Head Lens Cover: PSU
Head Gasket: FKM (lens cover), EVM (cable)
Cable: PVC
Amplifier Case: PBT; Amplifier Display, Indicator: PAR; Amplifier Gasket: NBR; Button: POM
Amplifier M8 Connector: SUS303

Accessories

Instruction manual, laser warning label

Weight

Approx. 35 g

*1 Ensure the cable length is 30 m 98.4' or less for the M8 connector type. Ensure the cable length is 20 m 65.6' or less when connecting via IO-Link.
*2 If 500 µs is selected, the following limitations apply.
· Only 2-point calibration can be performed.
· The detection range masking is set during calibration. (Manual setting of the masking range is not supported.)
· Output 2 is limited to an alarm output for errors and gyro issues, and standard/area cannot be used.
*3 Classification performed based on IEC60825-1 standards in accordance with FDA (CDRH) Laser Notice.
*4 The I/O can be selected from the following combinations. Control output × 2, Control output + External input

Keyence Stock Image
Keyence LK-2503 Keyence
Sale price $4,512.62
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD2-P30W04U2 DISPLAC. SENS, OPTICAL Sick
Sale price $1,141.12
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD2-P250W150I0 DISPLAC. SENS, OPTICAL Sick
Sale price $1,534.04
Only 3 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD2-P50W10I2 DISPLAC. SENS, OPTICAL Sick
Sale price $2,517.64
Only 2 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image
Sick OD2-P30W04A0 DISPLAC. SENS, OPTICAL Sick
Sale price $1,199.08
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Sick New Stock Image

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed