Circuit Breakers

17712 products

Showing 17665 - 17688 of 17712 products

Showing 17665 - 17688 of 17712 products
View
1SDA013833R1 ABB - UVR 24VDC S3-S4-S5

Environmental

Environmental Information:

Ordering

EAN:
8015644138332
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Width:
110 mm
Product Net Height:
60 mm
Product Net Depth / Length:
0.14 m
Product Net Weight:
0.128 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Height:
60 mm
Package Level 1 Depth / Length:
110 mm
Package Level 1 Gross Weight:
0.128 kg
Package Level 1 EAN:
8015644138332

Additional Information

Product Main Type:
Spare Parts
Product Name:
Accessory
Suitable For:
S3
S4
S5
S3
S4
S5
Suitable for Product Class:
Isomax

Technical

Device:
S3-S4-S5

Certificates and Declarations

Data Sheet, Technical Information:
Declaration of Conformity - CE:
Instructions and Manuals:

External Classifications and Standards

Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
1SDA055912R1 ABB - E2N1600PR121/P-LIIn=1600A4pWMP

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644572525
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
414 mm
Product Net Height:
461 mm
Product Net Depth / Length:
396.5 mm
Product Net Weight:
61 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
73 kg
Package Level 1 EAN:
8015644572525

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Ue =< 440 V 12000 cycle
Ue = 500 ... 690 V 10000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
215 W
Rated Current (In):
1600 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
1600 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 55 kA
for 3 s 42 kA
for 1 s 55 kA
for 3 s 42 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(380 V AC) 65 kA
(400 V AC) 65 kA
(415 V AC) 65 kA
(440 V AC) 65 kA
(500 V AC) 55 kA
(660 V AC) 55 kA
(690 V AC) 55 kA
Rated Uninterrupted Current (Iu):
1600 A
Rated Voltage (Ur):
690 V
Release:
PR121/P-LI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E2
Terminal Connection Type:
Withdrawable Circuit-Breakers

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
E2N1000PR122/P-LSIIn=1000A4pFHR ABB - 1SDA059275R1

E2N 1000 PR122/P-LSI IN=1000A 4P F HR

E2B1600PR121/P-LSIIn=1600A4pWMP ABB - 1SDA055817R1

E2B 1600 PR121/P-LSI In=1600A 4p W MP

E2S1000PR121/P-LSIGIn=1000A3pWMP ABB - 1SDA059310R1

E2S 1000 PR121/P-LSIG In=1000A 3p W MP

1SDA066321R1 ABB - SOR-C XT1..XT4 F/P 12 Vdc

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
KXTASORCFPA
E-Number (Norway):
4384925
EAN:
8015644692179
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Weight:
0.114 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
110 mm
Package Level 1 Height:
60 mm
Package Level 1 Depth / Length:
140 mm
Package Level 1 Gross Weight:
0.12 kg
Package Level 1 EAN:
8015644692179

Additional Information

Product Main Type:
Accessories for Tmax XT
Product Name:
Accessory
Product Type:
Accessory
Suitable For:
XT1, XT2, XT3, XT4
Suitable for Product Class:
SACE Tmax XT

Technical

Configuration Type:
Loose or configurable
Current Type:
DC
Order Multiple:
1 piece
Rated Voltage (Ur):
12 V DC
Standards:
IEC60947-2
UL489
IEC60947-2
UL489

External Classifications and Standards

ETIM 9:
EC002483 - Switch spool for power circuit breaker
ETIM 10:
EC002483 - Switch spool for power circuit breaker
IDEA Granular Category Code (IGCC):
4879 >> Shunt release (for power circuit breaker)
Object Classification Code:
Q
UNSPSC:
39121601
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370421
ABB New Stock Image
ABB 1SDA074172R1 ABB
Sale price $112.83
Only 10 units left

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
ZEAPWRS
E-Number (Norway):
4381725
E-Number (Sweden):
3186271
EAN:
8015644781057
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Width:
120 mm
Product Net Height:
155 mm
Product Net Depth / Length:
190 mm
Product Net Weight:
0.05 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
120 mm
Package Level 1 Height:
155 mm
Package Level 1 Depth / Length:
190 mm
Package Level 1 Gross Weight:
0.06 kg
Package Level 1 EAN:
8015644781057

Additional Information

Product Main Type:
Accessories for Emax 2, Accessories for Tmax XT
Product Name:
Accessory
Product Type:
Accessory
Suitable For:
XT7-XT7M, E1.2, E2.2, E4.2, E6.2
Suitable for Product Class:
SACE Tmax XT, SACE Emax 2

Technical

Configuration Type:
Loose or configurable
Order Multiple:
1 piece
Standards:
IEC

External Classifications and Standards

ETIM 9:
EC002498 - Accessories/spare parts for low-voltage switch technology
ETIM 10:
EC002498 - Accessories/spare parts for low-voltage switch technology
IDEA Granular Category Code (IGCC):
3592 >> Fieldbus, decentr. periphery - power supply module
Object Classification Code:
Q
UNSPSC:
32151802
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27371392
1SDA059526R1 ABB - T4V 250 PR223DS In 250A 4p F F

Tmax T - Automatic MCCB, fixed, with front terminals T4V PR223DS F 250 F 250 (4 poles)

1SDA071660R1 ABB - E2.2B 2000 Ekip G Hi-Touch LSIG 4p F HR

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
ZBBTEKBQ200A000000XX
EAN:
8015644755102
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
366 mm
Product Net Height:
371 mm
Product Net Depth / Length:
270 mm
Product Net Weight:
53 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
615 mm
Package Level 1 Gross Weight:
58 kg
Package Level 1 EAN:
8015644755102

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Neutral Pole Current ([%Iu]):
100 %
Number of Poles:
4P
Power Loss:
212 W
Rated Current (In):
2000 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(220 V AC) 42 kA
(230 V AC) 42 kA
(380 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 42 kA
for 3 s 42 kA
for 1 s 42 kA
for 3 s 42 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
(400 V AC) 42 kA
(415 V AC) 42 kA
(440 V AC) 42 kA
(500 V AC) 42 kA
(525 V AC) 42 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu):
2000 A
Rated Voltage (Ur):
690 V
Release:
Ekip G Hi-Touch LSIG
Release Type:
EL
Short-Circuit Performance Level:
B
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V
Terminal Connection Type:
Rear flat Horizontal

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SDA104760R1 ABB - KIT R- REAR TERMINALS - XT5 3pcs

ABB EcoSolutions

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
KXT5R-3PC
E-Number (Norway):
4381041
EAN:
8015644068523
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Weight:
0.942 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
507 mm
Package Level 1 Height:
59 mm
Package Level 1 Depth / Length:
311 mm
Package Level 1 Gross Weight:
0.992 kg
Package Level 1 EAN:
8015644068523

Additional Information

Product Main Type:
Accessories for Tmax XT
Product Name:
Accessory
Product Type:
Accessory
Suitable For:
XT5
Suitable for Product Class:
SACE Tamx XT

Technical

Configuration Type:
Loose or configurable
Number of Poles:
3P
Order Multiple:
1 piece
Standards:
IEC60947-2
UL489
IEC60947-2
UL489

External Classifications and Standards

ETIM 9:
EC002019 - Connection vane/phase spreader
ETIM 10:
EC002019 - Connection vane/phase spreader
IDEA Granular Category Code (IGCC):
4603 >> Electrical terminals
UNSPSC:
39121432
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27371305
1SDA066588R1 ABB - PLL XT1-XT3 REMOV.PADL.DEVICE OPEN PLUG.

ABB EcoSolutions

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
KXTBPLLREM
E-Number (Norway):
4384957
EAN:
8015644004989
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Weight:
0.029 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
145 mm
Package Level 1 Height:
30 mm
Package Level 1 Depth / Length:
250 mm
Package Level 1 Gross Weight:
0.031 kg
Package Level 1 EAN:
8015644004989

Additional Information

Product Main Type:
Accessories for Tmax XT
Product Name:
Accessory
Product Type:
Accessory
Suitable For:
XT1, XT3
Suitable for Product Class:
SACE Tmax XT

Technical

Configuration Type:
Loose or configurable
Order Multiple:
1 piece
Standards:
IEC60947-2
UL489
IEC60947-2
UL489

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC002498 - Accessories/spare parts for low-voltage switch technology
ETIM 10:
EC002498 - Accessories/spare parts for low-voltage switch technology
IDEA Granular Category Code (IGCC):
7344 >> Padlocks
Object Classification Code:
Q
UNSPSC:
46171501
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27371390
1SDA062910R1 ABB - T7H 1250 PR332/P LSI In=1250A 4p F F

ABB EcoSolutions

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Ordering

EAN:
8015644654597
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
280 mm
Product Net Height:
268 mm
Product Net Depth / Length:
154 mm
Product Net Weight:
12.5 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
360 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
360 mm
Package Level 1 Gross Weight:
14 kg
Package Level 1 EAN:
8015644654597

Additional Information

Product Main Type:
SACE Tmax T
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Suitable For:
T7
Suitable for Product Class:
Moulded Case Circuit Breakers
Version:
F

Technical

Electrical Durability:
2000 cycle
60 cycles per hour
2000 cycle
60 cycles per hour
Mechanical Durability:
10000 cycle
60 cycles per hour
10000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
at Rated Operating Conditions per Pole 47 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 31.5 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 31.5 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 20 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 42 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 70 kA
(400 V AC) 70 kA
(415 V AC) 70 kA
(440 V AC) 65 kA
(500 V AC) 50 kA
(690 V AC) 42 kA
Rated Uninterrupted Current (Iu):
1250 A
Release:
PR332/P LSI
Release Type:
EL
Short-Circuit Performance Level:
H
Standards:
IEC
Sub-type:
T7
Terminal Connection Type:
Fixed Circuit-Breakers
Front
Fixed Circuit-Breakers
Front

Certificates and Declarations

Data Sheet, Technical Information:
Declaration of Conformity - CE:
GL Certificate:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39121100
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SDA060689R1 ABB - KIT FC CuAl 4x150mm2 T6 1000 6pcs

ABB EcoSolutions

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

EAN:
8015644632120
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Weight:
2.45 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
145 mm
Package Level 1 Height:
155 mm
Package Level 1 Depth / Length:
295 mm
Package Level 1 Gross Weight:
2.45 kg
Package Level 1 EAN:
8015644632120

Additional Information

Product Main Type:
Accessories for Tmax T
Product Name:
Accessory
Product Type:
Accessory
Suitable For:
T6
Suitable for Product Class:
SACE Tmax T

Technical

Configuration Type:
Loose or configurable
Number of Poles:
3P
Standards:
IEC

External Classifications and Standards

ETIM 9:
EC002019 - Connection vane/phase spreader
ETIM 10:
EC002019 - Connection vane/phase spreader
Object Classification Code:
Q
UNSPSC:
39121100
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27371305
1SDA013575R1 ABB
ABB 1SDA013575R1 ABB
Sale price $456.35
Only 1 unit left

Environmental

Environmental Information:

Ordering

EAN:
8015644135751
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85389099

Dimensions

Product Net Width:
105 mm
Product Net Height:
55 mm
Product Net Depth / Length:
0.135 m
Product Net Weight:
0.097 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Height:
55 mm
Package Level 1 Depth / Length:
105 mm
Package Level 1 Gross Weight:
0.097 kg
Package Level 1 EAN:
8015644135751

Additional Information

Product Main Type:
Spare Parts
Product Name:
Accessory
Suitable For:
S3
S4
S5
S3
S4
S5
Suitable for Product Class:
Isomax

Technical

Device:
S3-S4-S5

Certificates and Declarations

Data Sheet, Technical Information:
Declaration of Conformity - CE:
Instructions and Manuals:

External Classifications and Standards

Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
E2S1000PR121/P-LSIGIn=1000A4pWMP ABB - 1SDA059312R1

E2S 1000 PR121/P-LSIG In=1000A 4p W MP

1SDA072197R1 ABB - E1.2N 1250 Ekip G Touch LSIG 3p WMP

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 76.4 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z1NREHAN200A000000XX
EAN:
8015644760472
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
278 mm
Product Net Height:
363.5 mm
Product Net Depth / Length:
271 mm
Product Net Weight:
18 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
270 mm
Package Level 1 Height:
350 mm
Package Level 1 Depth / Length:
330 mm
Package Level 1 Gross Weight:
20 kg
Package Level 1 EAN:
8015644760472

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
Ue =< 440 V 8000 cycle
Ue = 500 ... 690 V 6500 cycle
30 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
244 W
Rated Current (In):
1250 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
(220 V AC) 66 kA
(230 V AC) 66 kA
(380 V AC) 66 kA
(400 V AC) 50 kA
(415 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 50 kA
(660 V AC) 50 kA
(690 V AC) 50 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 50 kA
for 3 s 30 kA
for 1 s 50 kA
for 3 s 30 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
(400 V AC) 66 kA
(415 V AC) 66 kA
(440 V AC) 66 kA
(500 V AC) 50 kA
(525 V AC) 50 kA
(690 V AC) 50 kA
Rated Uninterrupted Current (Iu):
1250 A
Rated Voltage (Ur):
690 V
Release:
Ekip G Touch LSIG
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC
Sub-type:
E1.2
Suitable for IT Networks:
Yes, 690V

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SDA056312R1 ABB - E3S3200PR121/P-LIIn=3200A4pFHR

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644576523
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
530 mm
Product Net Height:
418 mm
Product Net Depth / Length:
302 mm
Product Net Weight:
76 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
785 mm
Package Level 1 Gross Weight:
90 kg
Package Level 1 EAN:
8015644576523

Additional Information

Product Main Type:
SACE Emax
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
F

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 6000 cycle
Ue = 500 ... 690 V 5000 cycle
20 cycles per hour
Ue =< 440 V 6000 cycle
Ue = 500 ... 690 V 5000 cycle
20 cycles per hour
Mechanical Durability:
20000 cycle
60 cycles per hour
20000 cycle
60 cycles per hour
Number of Poles:
4P
Power Loss:
330 W
Rated Current (In):
3200 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
3200 A
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 75 kA
for 3 s 65 kA
for 1 s 75 kA
for 3 s 65 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
(220 V AC) 75 kA
(230 V AC) 75 kA
(380 V AC) 75 kA
(400 V AC) 75 kA
(415 V AC) 75 kA
(440 V AC) 75 kA
(500 V AC) 75 kA
(660 V AC) 75 kA
(690 V AC) 75 kA
Rated Uninterrupted Current (Iu):
3200 A
Rated Voltage (Ur):
690 V
Release:
PR121/P-LI
Release Type:
EL
Short-Circuit Performance Level:
S
Standards:
IEC
Sub-type:
E3
Terminal Connection Type:
Fixed Circuit-Breakers
Rear flat Horizontal
Fixed Circuit-Breakers
Rear flat Horizontal

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
WEEE Category:
4. Large Equipment (Any External Dimension More Than 50 cm)
1SDA072404R1 ABB - E2.2H 2000 Ekip Touch LI 3p WMP

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 79.1 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
5db9272f-d385-4a4a-a0e6-73274e7613b2 Italy

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
Z2HTEKAD000A000000XX
EAN:
8015644762544
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
317 mm
Product Net Height:
425 mm
Product Net Depth / Length:
383 mm
Product Net Weight:
48 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
610 mm
Package Level 1 Depth / Length:
515 mm
Package Level 1 Gross Weight:
53 kg
Package Level 1 EAN:
8015644762544

Additional Information

Product Main Type:
SACE Emax 2
Product Name:
Air Circuit Breaker
Product Type:
Air Circuit Breaker
Version:
W
CAD Dimensional Drawing:

Technical

Current Type:
AC
Electrical Durability:
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Ue =< 440 V 10000 cycle
Ue = 500 ... 690 V 8000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
450 W
Rated Current (In):
2000 A
Rated Impulse Withstand Voltage (Uimp):
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui):
AC 1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
(220 V AC) 100 kA
(230 V AC) 100 kA
(380 V AC) 100 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(660 V AC) 85 kA
(690 V AC) 85 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics):
100 %
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 85 kA
for 3 s 66 kA
for 1 s 85 kA
for 3 s 66 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
(400 V AC) 100 kA
(415 V AC) 100 kA
(440 V AC) 100 kA
(500 V AC) 85 kA
(525 V AC) 85 kA
(690 V AC) 85 kA
Rated Uninterrupted Current (Iu):
2000 A
Rated Voltage (Ur):
690 V
Release:
Ekip Touch LI
Release Type:
EL
Short-Circuit Performance Level:
H
Standards:
IEC
Sub-type:
E2.2
Suitable for IT Networks:
Yes, 690V

Certificates and Declarations

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC):
4926 >> Air circuit breakers
Object Classification Code:
Q
UNSPSC:
39121615
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SDA051207R1 ABB - T2N 160 MA20 Im=120...240 3p F F

Moulded / Molded Case Circuit Breaker (MCCB) - ABB / SACE (Tmax T (IEC) series) - T2N 160 MA20 Im=120...240 3p F F - 3-poles (3P3d) - Rated current 20A (160 oversized frame) - Short circuit breaking capacity (Icu) 36kA (415Vac) - Magnetic only (MA (adjustable)) trip unit

1SDA068070R1 ABB - XT3N 250 TMD 250-2500 4p F F InN100%
ABB 1SDA068070R1 ABB - XT3N 250 TMD 250-2500 4p F F InN100%
Sale price $446.51
In stock, 12 units

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 56.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
4bf096d9-e0fb-41ce-9dab-01143bc6aed0 Italy
Simplified SCIP:
f122247f-3237-4c76-972d-808b882f9788 Germany
1f6795c1-9452-48f9-9d9a-f30ef9077f03 Spain
b2452708-7dc6-4407-9cd2-85d23e158939 Netherlands
cd120aec-54c5-4212-b458-6ac579d978f8 Netherlands
2010a811-d716-409f-8aa2-8c7dbaa7435e Germany
1df91a01-99c8-4fd4-9dd0-fd8633acf4dc Sweden
90e4f520-59d4-4837-b216-33abd64db25b Denmark
36f60159-a0f7-43ae-82ce-c05caa318767 Germany
3622c1af-6fb2-4105-a42f-ff7cf0cdd098 Poland
17df639b-1ddf-4990-b85a-b611ac0056b8 Norway
5c33c800-07e4-4dc9-a45b-a654c38bdcca Finland
578c2271-385e-47d4-96c2-78f0b62cd407 Netherlands
42f5d41d-9472-4bcb-af56-b4f5f0adb9f9 Croatia
17225d7a-362a-4551-ba19-a94719ff5cbc Czech Republic
ed0f2646-c591-4aa9-83ed-0341adcfcb9c Poland
0e3da230-1e90-44e5-810f-5ae4d4a053d7 Netherlands
91d082ac-941d-45ed-8bfd-30f694256596 Estonia
2b0f6517-2b81-4d17-9235-052143f7e69d Greece
230cead5-c984-438e-833a-fa9f9a190913 Portugal
734c1740-92a6-476b-8ab4-471386ae21a4 Bulgaria
9de1a02e-815c-4e49-b0ce-16ab721c88e0 Sweden
fdc9bfb7-1a5d-4026-8b82-a30c8c268ca7 Poland
86a701a4-5c49-4380-8b8a-1b53639cfd80 France
07da6dbe-40d9-4768-8eae-6b1fc5ae9a5a Germany
cb0986c3-7523-4eab-bacc-2d2b0ce88e8d Germany
ccbae2bd-88cc-42e1-a604-4b09aaa05639 France
f463799e-670e-49d3-8d9d-9d5d23697f1b Netherlands
f122247f-3237-4c76-972d-808b882f9788 Germany
1f6795c1-9452-48f9-9d9a-f30ef9077f03 Spain
b2452708-7dc6-4407-9cd2-85d23e158939 Netherlands
cd120aec-54c5-4212-b458-6ac579d978f8 Netherlands
2010a811-d716-409f-8aa2-8c7dbaa7435e Germany
1df91a01-99c8-4fd4-9dd0-fd8633acf4dc Sweden
90e4f520-59d4-4837-b216-33abd64db25b Denmark
36f60159-a0f7-43ae-82ce-c05caa318767 Germany
3622c1af-6fb2-4105-a42f-ff7cf0cdd098 Poland
17df639b-1ddf-4990-b85a-b611ac0056b8 Norway

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT3NE4250AFF000XXX
E-Number (Norway):
4309763
E-Number (Sweden):
3182424
EAN:
8015644019716
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
140 mm
Product Net Height:
150 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
2.1 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
155 mm
Package Level 1 Height:
190 mm
Package Level 1 Depth / Length:
155 mm
Package Level 1 Gross Weight:
2.214 kg
Package Level 1 EAN:
8015644019716

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 85..192 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 17.8 W
Rated Current (In):
250 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
2500 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 2 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 9,75 kA
(690 V AC) 3,75 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 50 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 20 kA
(525 V AC) 13 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
250 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M8
Release:
TMD
Release Type:
TM
Setting Range:
175...250 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT3
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
8 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
1SDA067428R1 ABB - XT1N 160 TMD 160-1600 4p F F InN=100%

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 55.9 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
0ac951c1-9b40-4f47-a751-2ab056ffe1d8 Italy
Simplified SCIP:
47481f31-3db7-43fa-90e7-510370035ce9 Germany
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
585d169a-087c-4da7-ad22-14f7211e98a1 Netherlands
ff4fab3b-79ba-48cf-8ed4-5efe459324fa Estonia
f70a208d-8500-4b87-8e80-56eb4dcb62f2 Greece
ab874939-835a-44db-8d0f-0ae656d2b42c Portugal
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
bd36d84d-14a0-4614-8240-3ca69ef29c39 Sweden
9be1dbef-ca32-4fe8-b574-89b5a88b48ee Germany
de6316e9-bdb1-43e5-b16d-b95b72c5dfb4 Germany
602c2f91-c382-4023-97d1-6af1a6d6081a France
8cba98fa-d5d2-4ec5-bf3c-1960563892a0 Netherlands
bd36d84d-14a0-4614-8240-3ca69ef29c39 Sweden
9be1dbef-ca32-4fe8-b574-89b5a88b48ee Germany
de6316e9-bdb1-43e5-b16d-b95b72c5dfb4 Germany
602c2f91-c382-4023-97d1-6af1a6d6081a France
8cba98fa-d5d2-4ec5-bf3c-1960563892a0 Netherlands
17496149-365a-445d-af68-54e4bc6db1db Spain
14cd69a0-0aec-4cca-80b5-96c95c8af3e4 Netherlands
e3656c3b-bce5-47e5-afeb-7f009b696b0a Bulgaria
de206646-cbea-472d-bc5e-38f523d75152 Sweden
14cd69a0-0aec-4cca-80b5-96c95c8af3e4 Netherlands
cce5ff42-1b35-421b-84db-020aa9af0a7a Poland
ff4fab3b-79ba-48cf-8ed4-5efe459324fa Estonia
f70a208d-8500-4b87-8e80-56eb4dcb62f2 Greece
ab874939-835a-44db-8d0f-0ae656d2b42c Portugal
e3656c3b-bce5-47e5-afeb-7f009b696b0a Bulgaria
de206646-cbea-472d-bc5e-38f523d75152 Sweden
cce5ff42-1b35-421b-84db-020aa9af0a7a Poland
17496149-365a-445d-af68-54e4bc6db1db Spain
a8e7d90f-4315-4279-a905-8664948cfaff Poland
4dc6cdf8-32d7-49b1-a117-c0ce3ad2f633 Norway
c3b8ec46-1389-4df7-8ed0-faeafd3b6c2d Finland
17032ab3-d170-46a5-983e-858cc49ab98d Netherlands
a4916536-3f0a-4c32-979a-0ef6d86b33ea Germany
7f380bd4-62bf-43fd-b963-40441f5c8867 Denmark
29282873-f42c-494c-a6f0-215e2e76a9f8 Germany
31575187-3d16-43b1-ad84-85ff5a7ee577 Croatia
99bddbbc-3e48-4a6d-b5b0-61c3be192e43 Czech Republic
3024527b-6e7a-4d6a-a536-159275b759d0 Poland
83801f67-afd3-4187-897a-3539e975ecba Netherlands
585d169a-087c-4da7-ad22-14f7211e98a1 Netherlands
a8e7d90f-4315-4279-a905-8664948cfaff Poland
4dc6cdf8-32d7-49b1-a117-c0ce3ad2f633 Norway
c3b8ec46-1389-4df7-8ed0-faeafd3b6c2d Finland
17032ab3-d170-46a5-983e-858cc49ab98d Netherlands
a4916536-3f0a-4c32-979a-0ef6d86b33ea Germany
7f380bd4-62bf-43fd-b963-40441f5c8867 Denmark
29282873-f42c-494c-a6f0-215e2e76a9f8 Germany
31575187-3d16-43b1-ad84-85ff5a7ee577 Croatia
99bddbbc-3e48-4a6d-b5b0-61c3be192e43 Czech Republic
3024527b-6e7a-4d6a-a536-159275b759d0 Poland
83801f67-afd3-4187-897a-3539e975ecba Netherlands
47481f31-3db7-43fa-90e7-510370035ce9 Germany
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
585d169a-087c-4da7-ad22-14f7211e98a1 Netherlands
ff4fab3b-79ba-48cf-8ed4-5efe459324fa Estonia
f70a208d-8500-4b87-8e80-56eb4dcb62f2 Greece
ab874939-835a-44db-8d0f-0ae656d2b42c Portugal
3d1957e6-6fff-4ac5-a4de-caa94ab5c364 France
bd36d84d-14a0-4614-8240-3ca69ef29c39 Sweden
9be1dbef-ca32-4fe8-b574-89b5a88b48ee Germany
de6316e9-bdb1-43e5-b16d-b95b72c5dfb4 Germany

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT1NE4160AFF000XXX
E-Number (Norway):
4379239
E-Number (Sweden):
3182447
EAN:
8015644013226
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
101.6 mm
Product Net Height:
130 mm
Product Net Depth / Length:
70 mm
Product Net Weight:
1.4 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
128 mm
Package Level 1 Height:
135 mm
Package Level 1 Depth / Length:
143 mm
Package Level 1 Gross Weight:
1.47 kg
Package Level 1 EAN:
8015644013226

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F
CAD Dimensional Drawing:

Technical

Connecting Capacity Main Circuit:
Busbar 45.5 ... 80 mm²
Current Type:
AC/DC
Electrical Durability:
120 cycles per hour
8000 cycle
120 cycles per hour
8000 cycle
Mechanical Durability:
240 cycles per hour
25000 cycle
240 cycles per hour
25000 cycle
Number of Poles:
4P
Opening Time:
CB with SOR 30 ms
CB with UVR 30 ms
CB with SOR 30 ms
CB with UVR 30 ms
Order Multiple:
1 piece
Power Loss:
at Rated Operating Conditions per Pole 15 W
Rated Current (In):
160 A
Rated Frequency (f):
50 / 60 Hz
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii):
1600 A
Rated Insulation Voltage (Ui):
800 V
Rated Operational Voltage:
690 V AC
500 V DC
690 V AC
500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 50 kA
(230 V AC) 50 kA
(240 V AC) 50 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(525 V AC) 11 kA
(690 V AC) 5 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
(500 V DC) 3 Poles in Series 36 kA
(220 V AC) 65 kA
(230 V AC) 65 kA
(240 V AC) 65 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 30 kA
(525 V AC) 22 kA
(690 V AC) 6 kA
(250 V DC) 2 Poles in Series 36 kA
Rated Uninterrupted Current (Iu):
160 A
Rated Voltage (Ur):
690 V
Recommended Screw Driver:
Main Circuit M6
Release:
TMD
Release Type:
TM
Setting Range:
112...160 A
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT1
Terminal Connection Type:
Front
Terminal Type:
Bolt
Tightening Torque:
6 N·m

Certificates and Declarations

ATEX Certificate:
Declaration of Conformity - CE:
GL Certificate:
LR Certificate:
UL Certificate:
VDE Certificate:
Dimension Diagram:
Mechanical Drawings:
Instructions and Manuals:

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ABB New Stock Image
ABB 1SDA100359R1 ABB
Sale price $1,023.47
Only 6 units left

ABB EcoSolutions

ABB EcoSolutions:
Yes
ABB Site Meeting Group Waste To Landfill Target:
UL 2799 Zero Waste To Landfill Validation available
End Of Life Disassembling Instructions:
Recyclability Rate of the Product acc. to EN45555:
Design for Closing Resource Loops - Standard EN45555 - 59.6 %

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):
Toxic Substances Control Act - TSCA:
SCIP:
090e3c3e-b079-4cc9-a4bf-402548b8fa41 Italy
Simplified SCIP:
4a007b80-29c3-45ab-9cd3-bc53b4f1afd6 Germany
4ef28cfb-8cbc-4076-8f6c-8681a89cd4b1 Sweden
c8a0a2c7-7065-4a9c-a87b-4191a801a260 Norway
2d49f980-1e49-45b9-a9b6-a81ed6f49d34 Finland
97a47a94-6c3f-4522-a38a-c97acfbddbb5 Netherlands
71452336-1cd5-4f6b-bbfc-25254f6a0173 Germany
d04ee358-6b62-426f-b7f7-33ed790f32f6 Denmark
7bd4d666-c8cb-4355-9ac4-65775fc1f63e Germany
0669be6b-e967-4794-a9ee-a46976dcd3bf Croatia
51c36c5c-af1c-423f-a73d-37dec3e62ee7 Czech Republic
734297d7-06b4-4cb3-abcf-7814faf00771 Poland
6841443d-d808-40bf-9e88-b82488c72978 Netherlands
2ffc7906-a600-4838-b0ff-699435ff21ac Netherlands
42dde5e1-91db-4d65-b45f-85e954e30cbc Estonia
9b70ff78-7e93-4335-b919-04c8edf91d9d Greece
594cfb38-d889-40b1-a9d3-a541822dc3de Portugal
ec550c0e-d709-4a2c-a992-7a283b06bea9 Bulgaria
2ae811e9-7871-48d0-a78e-480033788d4e Sweden
a3e1249b-c9ae-4d32-a01e-98c61bfa4eb5 Poland
31b22010-804b-4527-bde4-6d8929236bc0 France
3a93b966-0634-4c10-bb70-0bfb2c1957b8 Germany
2c438536-e6b4-4e17-9ae7-94e6c8dc92e6 Germany
e04606c2-e869-46b0-bfae-c43dad34ff66 France
5844de9a-f3c9-42c6-9b74-ede8fd543d2e Netherlands
7c8b7b9f-ef73-4d72-99b0-11bc17e05b03 Spain
b9e44577-a0d1-4e50-a6f7-12f5518e32ea Netherlands
b43ce538-523b-4797-8bcf-bed032936dd7 Poland
4a007b80-29c3-45ab-9cd3-bc53b4f1afd6 Germany
4ef28cfb-8cbc-4076-8f6c-8681a89cd4b1 Sweden
c8a0a2c7-7065-4a9c-a87b-4191a801a260 Norway
2d49f980-1e49-45b9-a9b6-a81ed6f49d34 Finland
97a47a94-6c3f-4522-a38a-c97acfbddbb5 Netherlands
71452336-1cd5-4f6b-bbfc-25254f6a0173 Germany
d04ee358-6b62-426f-b7f7-33ed790f32f6 Denmark
7bd4d666-c8cb-4355-9ac4-65775fc1f63e Germany
0669be6b-e967-4794-a9ee-a46976dcd3bf Croatia
51c36c5c-af1c-423f-a73d-37dec3e62ee7 Czech Republic

Environmental

Environmental Information:

Ordering

Order Code US and Canada:
XT5NE363BFFF000XXX
E-Number (Finland):
3641332
E-Number (Norway):
4380254
EAN:
8056221004367
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
140 mm
Product Net Height:
205 mm
Product Net Depth / Length:
103.5 mm
Product Net Weight:
4.82 kg

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
250 mm
Package Level 1 Height:
245 mm
Package Level 1 Depth / Length:
285 mm
Package Level 1 Gross Weight:
5.308 kg
Package Level 1 EAN:
8056221004367

Additional Information

Circuit Breaker Type to be Associated:
Power Distribution
Product Main Type:
SACE Tmax XT
Product Name:
Moulded Case Circuit Breaker
Product Type:
Automatic Circuit Breaker
Version:
F

Technical

Current Type:
AC
Electrical Durability:
5000 cycle
60 cycles per hour
5000 cycle
60 cycles per hour
Mechanical Durability:
20000 cycle
120 cycles per hour
20000 cycle
120 cycles per hour
Number of Poles:
3P
Order Multiple:
1 piece
Power Loss:
45 W
Rated Current (In):
630 A
Rated Impulse Withstand Voltage (Uimp):
8 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Voltage:
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics):
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
Rated Short-time Withstand Current Low Voltage (Icw):
6 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
(220 V AC) 70 kA
(230 V AC) 70 kA
(240 V AC) 70 kA
(380 V AC) 36 kA
(415 V AC) 36 kA
(440 V AC) 36 kA
(500 V AC) 25 kA
(525 V AC) 25 kA
(690 V AC) 20 kA
Rated Uninterrupted Current (Iu):
630 A
Release:
Ekip Dip LSI
Release Type:
EL
Short-Circuit Performance Level:
N
Standards:
IEC60947-2
Sub-type:
XT5
Terminal Connection Type:
Front

External Classifications and Standards

ETIM 9:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 10:
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code:
Q
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)
eClass:
V11.1 : 27370409
ABB Stock Image
ABB 1SDA058136R1 ABB
Sale price$0.00
Sold Out
Buy the ABB 1SDA058136R1 - a genuine ABB industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The ABB 1SDA058136R1 is a direct drop-in replacement for existing installations and ships ready for integration.
1SDA058959R1 ABB
ABB 1SDA058959R1 ABB
Sale price$0.00
Sold Out

Material Compliance

RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Conflict Minerals Reporting Template (CMRT):

Environmental

Environmental Information:

Ordering

EAN:
8015644613181
Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362090

Dimensions

Product Net Width:
324 mm
Product Net Height:
461 mm
Product Net Depth / Length:
396.5 mm
Product Net Weight:
49 kg

Container Information

Package Level 1 Units:
1 piece
Package Level 1 Width:
515 mm
Package Level 1 Height:
600 mm
Package Level 1 Depth / Length:
515 mm
Package Level 1 Gross Weight:
59 kg
Package Level 1 EAN:
8015644609139

Additional Information

Product Main Type:
SACE Emax
Product Name:
Switch Disconnector
Product Type:
Air Circuit Breaker
Version:
W

Technical

Current Type:
AC
Electrical Durability:
12000 cycle
30 cycles per hour
12000 cycle
30 cycles per hour
Mechanical Durability:
25000 cycle
60 cycles per hour
25000 cycle
60 cycles per hour
Number of Poles:
3P
Power Loss:
215 W
Rated Current (In):
1600 A
Rated Impulse Withstand Voltage (Uimp):
12 kV
Rated Insulation Voltage (Ui):
1000 V
Rated Operational Current (Ie):
1600 A
Rated Operational Voltage:
690 V AC
250 V DC
690 V AC
250 V DC
Rated Short-time Withstand Current Low Voltage (Icw):
for 1 s 42 kA
for 3 s 42 kA
for 1 s 42 kA
for 3 s 42 kA
Rated Uninterrupted Current (Iu):
1600 A
Rated Voltage (Ur):
690 V
Short-Circuit Performance Level:
B
Standards:
IEC
Sub-type:
E2
Terminal Connection Type:
Withdrawable Circuit-Breakers

Certificates and Declarations

External Classifications and Standards

Object Classification Code:
Q
UNSPSC:
39120000
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)