Filters
Best selling products
24830 products
circuit breaker 3VA2 IEC frame 160 breaking capacity class C Icu=110kA @ 415V 3-pole, line protection ETU860, LSIG, In=100A overload protection Ir=40A...100A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% gr.-fault prot., can be sw. off Ig=0.2...1 x In, tg=0.05-0.8s nut keeper kit
SIRIUS soft starter 200-480 V 470 A, 24 V AC/DC spring-type terminals Thermistor input
XUSL type 4 - Slave2 - For finger protection - Hp = 460 mm, R=14mm
XUSL type 4 Body IP69K with Heating - Long Sensing Range 510mm
Safety expansion block - TM7 - IP67 - 8 DI - 24V DC - 2 A - M12 connector
AC servo motor BSH - 1.1 N.m - 3000 rpm - untapped shaft - without brake - IP50
servo motor BMI 1-phase - untapped IP54 single turn - 32768 p/t - brake
servo motor BMH - 3.3 Nm - 6000 rpm - untapped shaft - without brake - IP65/IP67
servo motor BMH - 2.5 Nm - 8000 rpm - untapped shaft - without brake - IP65/IP67
Simatic WinCC Runtime Advanced 8192 PowerTags V14, Upgrade WinCC flexible 2008 Runtime 8000 PowerTags -> WinCC Runtime Advanced 8192 PowerTags V14; runtime software in TIA Portal; single license; software and documentation on DVD; license key on USB stick; Class A; 6 languages: GE,EN,IT,FR,ES,ZN; executable under Windows 7 (32 bit, 64 bit), Windows 8.1 (64 bit), WinSrv 2008/2012 R2 (64 bit);
circuit breaker VL250L very high breaking capacity Icu=100kA, 415V AC 3-pole, line protection Electronic Trip Unit ETU10, LI In=200A, rated current IR=80...200A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch Notes Sucessor:3VA2225-7JP32-0A..
circuit breaker 3VA6 UL frame 400 breaking capacity class C 100kA @ 480V 4-pole, line protection ETU320, LI, In=400A overload protection Ir=160A...400A short-circuit protection Ii=1.5...10 x In N conductor protection adjustable (OFF, 50%, 100%) without connection
circuit breaker 3VA6 UL frame 150 breaking capacity class L 150kA @ 480V 3-pole, line protection ETU560, LSIG, In=40A overload protection Ir=16A...40A short-circuit protection Isd=0.6..10x In, Ii=1.5..12x In N conductor protection optionally with external current transformer, up to 160% ground-fault protection Ig=0.375...1 x In, tg=0.05-0.8s without connection
circuit breaker 3VA2 IEC frame 630 breaking capacity class H Icu=85kA @ 415V 4-pole, line protection ETU350, LSI, In=630A overload protection Ir=250A...630A short-circuit protection Isd=1.5...9x Ir, Ii=9x In N conductor protection adjustable (OFF, 50%, 100%) nut keeper kit
servo motor BMH - 2.5 Nm - 8000 rpm - keyed shaft - without brake - IP65/IP67
servo motor BMH - 2.5 Nm - 8000 rpm - untapped shaft - without brake - IP65/IP67
servo motor BMH - 1.2 Nm - 8000 rpm - keyed shaft - with brake - IP65/IP67
enclosed Variable Speed Drive Altivar ATV31 - 1.1kW - 500V - IP55
circuit breaker VL400N standard breaking capacity Icu=55kA, 415V AC 4-pole, line protection Electronic Trip Unit LCD ETU40, LI/LS/LSI In=315A, rated current IR=128...315A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection N protected without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2340-5JP42-....
circuit breaker VL160L very high breaking capacity Icu=100kA, 415V AC 3-pole, motor protection Electronic Trip Unit ETU30M, LI IR=63...160A, overload prot., TC=10A...30, II=6/8/11 xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2216-7MQ32-0A..
plug-in unit complete kit accessory for: circuit breaker, 3-pole 3VA6 600 - - - - - - - - - - - - - - -
circuit breaker VL630H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU12, LIGN 3 phases/4 lines In=630A, rated current IR=252...630A, overload protection, II=1.25 to 10xIN, short-circuit protection without auxiliary release ETU communication-capable without auxiliary/alarm switch Notes Sucessor:3VA2463-6JQ32-0A..
circuit breaker VL400H high breaking capacity Icu=70kA, 415V AC 3-pole, line protection trip unit ETU22, LSIG 3 phases/3 lines In=400A, rated current IR=160...400A, overload protection, ISD=1.5 to 10xIR, II=11xIN short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2340-6JQ32-....
circuit breaker VL400L very high breaking capacity Icu=100kA, 415V AC 4-pole, line protection Electronic Trip Unit ETU10, LI In=315A, rated current IR=128...315A, overload protection, II=1.25 to 11xIN, short-circuit protection without auxiliary release without auxiliary/alarm switch Notes Sucessor:3VA2340-7HL42-....
Filters