ABB New Stock Image
ABB 1SAM450000R1005 ABB
Sale price $349.88
Only 3 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 1SAM250000R1008 ABB
Sale price $116.24
Only 10 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362010

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals (Part 2):

Dimensions

Product Net Width:
45 mm
Product Net Height:
90 mm
Product Net Depth / Length:
85.6 mm
Product Net Weight:
0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 6 kA
(500 V AC) 6 kA
(690 V AC) 2 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 6 kA
(500 V AC) 6 kA
(690 V AC) 2 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(690 V AC) 3 kA
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 18 kA
(500 V AC) 15 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
50 A
Setting Range:
2.5 ... 4.0 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 1.5 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 1.5 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Rated Operational Current (Ie):
4 A
Rated Operational Current AC-3 (Ie):
4 A
Rated Operational Current AC-3e (Ie):
4 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Power Loss:
at Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 4 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
100000 cycle
Mechanical Durability:
Nr. Operations 100000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque:
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length:
Main Circuit 9 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
any
1 ... 6
any
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:
Rotary Handle
Contact Position Indication:
ON / OFF
Standards:
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 0.75 Hp
(208 V AC) Three Phase 0.75 Hp
(220 ... 240 V AC) Three Phase 1 Hp
(440 ... 480 V AC) Three Phase 2 Hp
(550 ... 600 V AC) Three Phase 3 Hp
(200 V AC) Three Phase 0.75 Hp
(208 V AC) Three Phase 0.75 Hp
(220 ... 240 V AC) Three Phase 1 Hp
(440 ... 480 V AC) Three Phase 2 Hp
(550 ... 600 V AC) Three Phase 3 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 4 A
(208 V AC) Three Phase 4 A
(220 ... 240 V AC) Three Phase 4 A
(440 ... 480 V AC) Three Phase 4 A
(550 ... 600 V AC) Three Phase 3.9 A
(200 V AC) Three Phase 4 A
(208 V AC) Three Phase 4 A
(220 ... 240 V AC) Three Phase 4 A
(440 ... 480 V AC) Three Phase 4 A
(550 ... 600 V AC) Three Phase 3.9 A
Locked Rotor Amps:
(200 V AC) Three Phase 24 A
(208 V AC) Three Phase 24 A
(220 ... 240 V AC) Three Phase 24 A
(440 ... 480 V AC) Three Phase 24 A
(550 ... 600 V AC) Three Phase 25.6 A
(200 V AC) Three Phase 24 A
(208 V AC) Three Phase 24 A
(220 ... 240 V AC) Three Phase 24 A
(440 ... 480 V AC) Three Phase 24 A
(550 ... 600 V AC) Three Phase 25.6 A
General Use Rating UL/CSA:
(600 V AC) 4 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA:
Main Circuit 10 in·lb

Environmental

Ambient Air Temperature:
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
2g 5 ... 150 Hz
5g 3 ... 150 Hz
2g 5 ... 150 Hz
5g 3 ... 150 Hz

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

GL Certificate:
KC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
95 mm
Package Level 1 Height:
50 mm
Package Level 1 Gross Weight:
0.28 kg
Package Level 1 EAN:
4013614320316
Package Level 2 Units:
carton 40 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
11.586 kg
Package Level 2 EAN:
4013614408687

External Classifications and Standards

Object Classification Code:
F
ETIM 9:
EC000074 - Motor protection circuit-breaker
ETIM 10:
EC000074 - Motor protection circuit-breaker
eClass:
V11.0 : 27370401
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4731 >> Manual Starters
E-Number (Finland):
3706008
E-Number (Norway):
4364274
E-Number (Sweden):
3111944
ABB New Stock Image
ABB 1SAM350000R1015 ABB
Sale price $130.14
Only 10 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362010

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals (Part 2):

Dimensions

Product Net Width:
45 mm
Product Net Height:
97.8 mm
Product Net Depth / Length:
86.55 mm
Product Net Weight:
0.31 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
(230 V AC) 30 kA
(250 V DC) 3 Poles in Series 10 kA
(400 V AC) 30 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 30 kA
(500 V AC) 10 kA
(690 V AC) 3 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
480 A
Setting Range:
25 ... 32 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 15 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 15 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Main Circuit 250 V DC
Main Circuit 690 V AC
Main Circuit 250 V DC
Rated Operational Current (Ie):
32 A
Rated Operational Current AC-3 (Ie):
32 A
Rated Operational Current AC-3e (Ie):
32 A
Rated Operational Current DC-5 (Ie):
32 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (fsw):
0 ... 400 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Power Loss:
at Rated Operating Conditions per Pole 1.9 ... 3.1 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 32 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
50000 cycle
Mechanical Durability:
Nr. Operations 100000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Flexible with Ferrule 1/2x 0.75 ... 6 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 6 mm²
Flexible 1/2x 1 ... 2.5 mm²
Flexible 1/2x 2.5 ... 6 mm²
Rigid 1/2x 1 ... 2.5 mm²
Rigid 1/2x 2.5 ... 6 mm²
Tightening Torque:
Main Circuit 2 N·m
Wire Stripping Length:
Main Circuit 10 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:
Rotary Handle
Contact Position Indication:
ON / OFF / TRIP
Standards:
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
Remarks:
UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 35 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 18 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (480Y / 277 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in Group Installations (600Y / 347 V AC) 18 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
(200 V AC) Three Phase 7.5 Hp
(208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 27 A
(200 V AC) Three Phase 25.3 A
(208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 28 A
(440 ... 480 V AC) Three Phase 27 A
(550 ... 600 V AC) Three Phase 27 A
Locked Rotor Amps:
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 146 A
(200 V AC) Three Phase 146 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 162 A
(440 ... 480 V AC) Three Phase 145 A
(550 ... 600 V AC) Three Phase 146 A
General Use Rating UL/CSA:
(600 V AC) 32 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Flexible 1/2x 16-8 AWG
Stranded 1/2x 16-8 AWG
Tightening Torque UL/CSA:
Main Circuit 18 in·lb

Environmental

Ambient Air Temperature:
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
5g 3 ... 150 Hz

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

LR Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
102 mm
Package Level 1 Height:
50 mm
Package Level 1 Gross Weight:
0.325 kg
Package Level 1 EAN:
4013614400155
Package Level 2 Units:
carton 40 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
13.386 kg
Package Level 2 EAN:
4013614409059

External Classifications and Standards

Object Classification Code:
F
ETIM 9:
EC000074 - Motor protection circuit-breaker
ETIM 10:
EC000074 - Motor protection circuit-breaker
eClass:
V11.0 : 27370401
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4731 >> Manual Starters
E-Number (Finland):
3705999
E-Number (Norway):
4364083
E-Number (Sweden):
3112130
ABB New Stock Image
ABB 1SAM250000R1007 ABB
Sale price $116.24
Only 6 units left

Ordering

Minimum Order Quantity:
1 piece
Customs Tariff Number:
85362010

Popular Downloads

Data Sheet, Technical Information:
Instructions and Manuals (Part 2):

Dimensions

Product Net Width:
45 mm
Product Net Height:
90 mm
Product Net Depth / Length:
85.6 mm
Product Net Weight:
0.265 kg

Technical

Rated Service Short-Circuit Breaking Capacity (Ics):
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 10 kA
(500 V AC) 10 kA
(690 V AC) 5 kA
(230 V AC) 50 kA
(400 V AC) 50 kA
(440 V AC) 10 kA
(500 V AC) 10 kA
(690 V AC) 5 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu):
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 10 kA
(230 V AC) 75 kA
(400 V AC) 75 kA
(440 V AC) 30 kA
(500 V AC) 20 kA
(690 V AC) 10 kA
Rated Instantaneous Short-Circuit Current Setting (Ii):
31.3 A
Setting Range:
1.6 ... 2.5 A
Rated Operational Power AC-3 (Pe):
(400 V) Three Phase 0.75 kW
Rated Operational Power AC-3e (Pe):
(400 V) Three Phase 0.75 kW
Rated Operational Voltage:
Main Circuit 690 V AC
Rated Operational Current (Ie):
2.5 A
Rated Operational Current AC-3 (Ie):
2.5 A
Rated Operational Current AC-3e (Ie):
2.5 A
Rated Frequency (f):
Main Circuit 50 Hz
Main Circuit 60 Hz
Main Circuit 50 Hz
Main Circuit 60 Hz
Rated Impulse Withstand Voltage (Uimp):
Main Circuit 6 kV
Rated Insulation Voltage (Ui):
690 V
Power Loss:
at Rated Operating Conditions per Pole 0.7 ... 1.8 W
Number of Poles:
3P
Conventional Free-air Thermal Current (Ith):
Main Circuit 2.5 A
Degree of Protection:
Housing IP20
Main Circuit Terminals IP10
Housing IP20
Main Circuit Terminals IP10
Pollution Degree:
3
Electrical Durability:
100000 cycle
Mechanical Durability:
Nr. Operations 100000 cycle
Terminal Type:
Screw Terminals
Connecting Capacity Main Circuit:
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible 1/2x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
Tightening Torque:
Main Circuit 0.8 ... 1.2 N·m
Wire Stripping Length:
Main Circuit 9 mm
Recommended Screw Driver:
Pozidriv 2
Mounting Position:
1 ... 6
any
1 ... 6
any
Mounting on DIN Rail:
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Distance:
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type:
Rotary Handle
Contact Position Indication:
ON / OFF
Standards:
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-1
UL 60947-4-1
IEC 60335-2-40 A2L

Technical UL/CSA

Short-Circuit Current Rating (SCCR):
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 5 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 30 kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 5 kA
Maximum Operating Voltage UL/CSA:
Main Circuit 600 V AC
Horsepower Rating UL/CSA:
(200 V AC) Three Phase 0.5 Hp
(208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 1 Hp
(550 ... 600 V AC) Three Phase 1.5 Hp
(200 V AC) Three Phase 0.5 Hp
(208 V AC) Three Phase 0.5 Hp
(220 ... 240 V AC) Three Phase 0.5 Hp
(440 ... 480 V AC) Three Phase 1 Hp
(550 ... 600 V AC) Three Phase 1.5 Hp
Full Load Amps Motor Use:
(200 V AC) Three Phase 2.5 A
(208 V AC) Three Phase 2.5 A
(220 ... 240 V AC) Three Phase 2.5 A
(440 ... 480 V AC) Three Phase 2.5 A
(550 ... 600 V AC) Three Phase 2.5 A
(200 V AC) Three Phase 2.5 A
(208 V AC) Three Phase 2.5 A
(220 ... 240 V AC) Three Phase 2.5 A
(440 ... 480 V AC) Three Phase 2.5 A
(550 ... 600 V AC) Three Phase 2.5 A
Locked Rotor Amps:
(200 V AC) Three Phase 15 A
(208 V AC) Three Phase 15 A
(220 ... 240 V AC) Three Phase 15 A
(440 ... 480 V AC) Three Phase 15 A
(550 ... 600 V AC) Three Phase 15 A
(200 V AC) Three Phase 15 A
(208 V AC) Three Phase 15 A
(220 ... 240 V AC) Three Phase 15 A
(440 ... 480 V AC) Three Phase 15 A
(550 ... 600 V AC) Three Phase 15 A
General Use Rating UL/CSA:
(600 V AC) 2.5 A
Connecting Capacity Main Circuit UL/CSA:
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Flexible 1/2x 16-12 AWG
Stranded 1/2x 16-12 AWG
Tightening Torque UL/CSA:
Main Circuit 10 in·lb

Environmental

Ambient Air Temperature:
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Around the Enclosure 0 ... +40 °C
Operation -25 ... +70 °C
Operation Compensated -25 ... +55 °C
Storage -50 ... +80 °C
Ambient Air Temperature Compensation:
Yes
Maximum Operating Altitude Permissible:
2000 m
Resistance to Shock acc. to IEC 60068-2-27:
11 ms Pulse 25g
Resistance to Vibrations:
2g 5 ... 150 Hz
5g 3 ... 150 Hz
2g 5 ... 150 Hz
5g 3 ... 150 Hz

Material Compliance

Conflict Minerals Reporting Template (CMRT):
RoHS Status:
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
WEEE B2C / B2B:
Business To Business
WEEE Category:
5. Small Equipment (No External Dimension More Than 50 cm)

Certificates and Declarations

GL Certificate:
KC Certificate:

Container Information

Package Level 1 Units:
box 1 piece
Package Level 1 Width:
92 mm
Package Level 1 Depth / Length:
95 mm
Package Level 1 Height:
50 mm
Package Level 1 Gross Weight:
0.28 kg
Package Level 1 EAN:
4013614320309
Package Level 2 Units:
carton 40 piece
Package Level 2 Width:
280 mm
Package Level 2 Depth / Length:
395 mm
Package Level 2 Height:
210 mm
Package Level 2 Gross Weight:
11.586 kg
Package Level 2 EAN:
4013614408670

External Classifications and Standards

Object Classification Code:
F
ETIM 9:
EC000074 - Motor protection circuit-breaker
ETIM 10:
EC000074 - Motor protection circuit-breaker
eClass:
V11.0 : 27370401
UNSPSC:
39121521
IDEA Granular Category Code (IGCC):
4731 >> Manual Starters
E-Number (Finland):
3706007
E-Number (Norway):
4364273
E-Number (Sweden):
3111942
ABB New Stock Image
ABB 1MAF38698-G2-VP ABB
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 1AC4002U ABB
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 17Q25L56 ABB
Sale price $374.82
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 1AC2103U ABB
Sale price $960.00
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 1SAM150000R1014 ABB
Sale price $116.49
Only 6 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 15QZ60L56 ABB
Sale price $352.00
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 15QZ25L56 ABB
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 14C107 ABB
Sale price $1,208.98
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 15Q10L56 ABB
Sale price $450.00
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 156HA356 ABB
Sale price $750.00
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 138974 ABB
Sale price $375.00
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 138980 ABB
Sale price$0.00
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 125S1982-3 ABB
Sale price $606.40
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 1326AB-B420E-21 ABB
Sale price $4,035.58
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 125S1983-8 ABB
Sale price $688.53
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 0-60031-5 ABB
Sale price $2,175.00
Only 2 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 110815 ABB
Sale price $377.99
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 0-57200 ABB
Sale price $560.00
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 0-58706-17B ABB
Sale price $640.00
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
ABB New Stock Image
ABB 0-54400-7 ABB
Sale price $1,240.00
Only 1 unit left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Recently viewed