Ordering
4016779851473
1 piece
85364900
Popular Downloads
Dimensions
22.5 mm
85.6 mm
103.7 mm
0.136 kg
Technical
OFF-Delay
0.05 s ... 300 h
24 ... 240 V AC
24 ... 48 V DC
24 ... 240 V AC
24 ... 48 V DC
Auxiliary Circuit 250 V
50 / 60 Hz
DC
50 / 60 Hz
DC
2 c/o (SPDT) contacts
Screw Terminals
(230 V) 4 A
(230 V) 3 A
(24 V) 4 A
(24 V) 2 A
12 V
100 mA
12 V
100 mA
Input Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Input Circuit 4 kV
Output Circuit 1 / Output Circuit 2 4 kV
Input Circuit / Output Circuit 500 V
Output Circuit 1 / Output Circuit 2 300 V
Input Circuit / Output Circuit 500 V
Output Circuit 1 / Output Circuit 2 300 V
Housing IP50
Terminals IP20
Housing IP50
Terminals IP20
III
3
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Output Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
AC-12 100000 cycle
Nr. Operations 30000000 cycle
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Flexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
0.6 ... 0.8 N·m
8 mm
0.8 x 4
4.5
Pozidriv 1
0.8 x 4
4.5
Pozidriv 1
1 ... 6
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61812-1
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61812-1
UL 508
Technical UL/CSA
Output Circuit 300 V AC
B300
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Flexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
7.08 in·lb
B300
V-0
Environmental
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Operation -25 ... +60 °C
Storage -40 ... +85 °C
Without Derating 2000 m
Material Compliance
0dd45698-9580-4e20-9d58-2ab9e1451475 Germany
7e322dd3-9740-4d36-969f-27566f61ae60 Bulgaria
8d03c4d5-1891-4811-ab90-7b0843457063 Portugal
f042ce57-1e49-4af5-b54a-0e2c07059db7 France
0dbe1e40-6493-4b1a-849e-d8ec6ec57542 Greece
861c20e3-7c79-4581-9ef1-51be464bb5ef Croatia
9eb52426-4f4e-4034-966f-cc90579525de Sweden
e927ff80-7ded-406a-9651-71e5ce9f2032 Poland
cd2dd550-881e-4231-a360-6634c79229bd Germany
0081793b-3029-45dc-8cc6-4a842b6b6992 Poland
6ac2a84f-30eb-40e7-8516-a4f596f1ac9d Denmark
24e0250c-14a0-44af-8d91-d5e01d2264cd Germany
c308b8a8-6eef-4f0b-928b-186cc8ca50ab Czech Republic
60041974-6915-494f-a859-1b2ff01ceff3 Finland
cacb55a2-47c5-42b9-8563-7ab9311beb1c Italy
37c0a774-9e30-4b8a-a0a6-d9d809d0aae0 Germany
e2295d2f-ae02-4129-bc7c-c7fd342678cf Netherlands
0307c7aa-d7b9-49b5-8e69-cb1d744bcafd Estonia
9a551610-649a-41f7-984f-fd612ce7885f Sweden
12da8731-dcc5-4589-9e5c-a303d3dd29a9 Poland
86c4e0ed-73fe-4cac-9911-72f182f8981c Norway
c9d4ff43-b675-471e-be8c-43809d893a28 France
7a67b254-6e37-4c98-ad21-142a7d22ca7c Germany
7175fdf2-e3b6-4962-9bb5-171e56b59bad Hungary
a385f795-de78-4e02-8205-b9056010162f Belgium
3aa9e445-415e-40bb-bc97-5f29c26d0424 Belgium
06dbf255-a931-4098-a66c-f8f76ae8f65b Hungary
346ddfcd-b02b-4542-87f8-07edf78b1ca9 Spain
7e322dd3-9740-4d36-969f-27566f61ae60 Bulgaria
8d03c4d5-1891-4811-ab90-7b0843457063 Portugal
f042ce57-1e49-4af5-b54a-0e2c07059db7 France
0dbe1e40-6493-4b1a-849e-d8ec6ec57542 Greece
861c20e3-7c79-4581-9ef1-51be464bb5ef Croatia
9eb52426-4f4e-4034-966f-cc90579525de Sweden
e927ff80-7ded-406a-9651-71e5ce9f2032 Poland
cd2dd550-881e-4231-a360-6634c79229bd Germany
0081793b-3029-45dc-8cc6-4a842b6b6992 Poland
6ac2a84f-30eb-40e7-8516-a4f596f1ac9d Denmark
ABB EcoSolutions
Certificates and Declarations
Container Information
box 1 piece
97 mm
30 mm
109 mm
0.158 kg
4016779851473
External Classifications and Standards
K
EC001439 - Timer relay
EC001439 - Timer relay
EC001439 - Timer relay
V11.0 : 27371605
39122329
2712205
4187958
4033117


Ordering
4013614528767
10 piece
85480090
Popular Downloads
Dimensions
13 mm
24 mm
9 mm
0.003 kg
Technical
Accessory for interface relays CR-M
Accessory for interface relays CR-P
Accessory for interface relays CR-M
Accessory for interface relays CR-P
Pluggable function module for pcb and miniature relay sockets
Spark quenching
110 ... 230 V AC/DC
none
none
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61984
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61984
UL 508
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
bag 10 piece
130 mm
9 mm
180 mm
0.032 kg
4013614373879
External Classifications and Standards
K
EC002586 - Accessories for switching relay
EC002586 - Accessories/spare parts for switching relay
EC002586 - Accessories/spare parts for switching relay
V11.0 : 27371692
39122331
2712724
4187442
4005384

Ordering
4013614498954
300 piece
85364900
Popular Downloads
Dimensions
21.5 mm
35 mm
28 mm
0.037 kg
Technical
Pluggable miniature interface relay CR-MX
Relay with built in LED
24 V DC
250 V AC
4 c/o (SPDT) contacts
250 V / 5 A
Flat-Pin Connections
(230 V) 5 A
(120 V) 1.9 A
(230 V) 0.8 A
(120 V) 1.9 A
(230 V) 0.8 A
(24 V) 5 A
(24 V) 1.8 A
(120 V) 0.5 A
(24 V) 1.8 A
(120 V) 0.5 A
Between Coil and Contacts 1.5 kV
250 V
IP40
1
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61810-1
UL 508
CAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 61810-1
UL 508
Technical UL/CSA
250 V AC
V-2
Environmental
Operation -40 ... +70 °C
Storage -40 ... +70 °C
Operation -40 ... +70 °C
Storage -40 ... +70 °C
Without Derating 2000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 10 piece
140 mm
35 mm
101 mm
0.411 kg
4013614487637
box 300 piece
300 mm
325 mm
205 mm
13.185 kg
4013614505553
External Classifications and Standards
K
EC001437 - Switching relay
EC001437 - Switching relay
EC001437 - Switching relay
V11.0 : 27371601
39122331

Ordering
4013614498282
10 piece
85364900
Popular Downloads
Dimensions
12.7 mm
15.7 mm
29 mm
0.014 kg
Technical
Pluggable pcb interface relay CR-P
Relay w/o built in LED
48 V DC
400 V AC
50 / 60 Hz
2 c/o (SPDT) contacts
250 V / 8 A
Soldering Pins
(230 V) 8 A
(120 V) 3 A
(230 V) 1.5 A
(120 V) 3 A
(230 V) 1.5 A
(24 V) 8 A
(24 V) 2 A
(250 V) 0.1 A
(24 V) 2 A
(250 V) 0.1 A
400 V
IP67
1
IEC/EN 61810-1
Technical UL/CSA
300 V AC
B300
B300
V-0
Environmental
Operation -40 ... +85 °C
Storage -40 ... +85 °C
Operation -40 ... +85 °C
Storage -40 ... +85 °C
Without Derating 2000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Certificates and Declarations
Container Information
box 10 piece
332 mm
17 mm
28 mm
0.157 kg
4013614373022
External Classifications and Standards
K
EC001437 - Switching relay
EC001437 - Switching relay
EC001437 - Switching relay
V11.0 : 27371601
39122331
2712745
4187339


Ordering
1 piece
85389099
Popular Downloads
Dimensions
120 mm
145 mm
34 mm
0.38 kg
Technical
Screw Terminals
A185
AF185
A185
AF185
Block Contactors
Main Contact Kit
Material Compliance
Following EU Directive 2011/65/EU
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
bag 1 piece
120 mm
145 mm
34 mm
0.43 kg
7320500204542
External Classifications and Standards
X
EC002498 - Accessories for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology
39122221
5219 >> Switch part or accessory
3709292
4120746

Ordering
1 piece
85364900
Popular Downloads
Dimensions
102 mm
123.5 mm
148 mm
1.9 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 50 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A
(690 V) 40 °C 160 A
(690 V) 55 °C 145 A
(690 V) 70 °C 130 A
(690 V) 40 °C 160 A
(690 V) 55 °C 145 A
(690 V) 70 °C 130 A
(415 V) 55 °C 115 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(380 / 400 V) 55 °C 115 A
(220 / 230 / 240 V) 55 °C 115 A
(415 V) 55 °C 115 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(380 / 400 V) 55 °C 115 A
(220 / 230 / 240 V) 55 °C 115 A
(415 V) 59 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
(415 V) 59 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 30 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
10 million
3600 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions per Pole 2.7 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Main Circuit: Bars
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
140 mm
170 mm
130 mm
2.1 kg
7320500500118
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85364900
Popular Downloads
Dimensions
102 mm
123.5 mm
148 mm
1.9 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 190 A
(690 V) 40 °C 190 A
(690 V) 55 °C 145 A
(690 V) 70 °C 130 A
(690 V) 40 °C 190 A
(690 V) 55 °C 145 A
(690 V) 70 °C 130 A
(415 V) 55 °C 150 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(380 / 400 V) 55 °C 150 A
(220 / 230 / 240 V) 55 °C 150 A
(415 V) 55 °C 150 A
(440 V) 55 °C 100 A
(500 V) 55 °C 100 A
(690 V) 55 °C 82 A
(380 / 400 V) 55 °C 150 A
(220 / 230 / 240 V) 55 °C 150 A
(415 V) 75 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 45 kW
(415 V) 75 kW
(440 V) 59 kW
(500 V) 59 kW
(690 V) 75 kW
(380 / 400 V) 75 kW
(220 / 230 / 240 V) 45 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
10 million
3600 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions per Pole 2.7 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Main Circuit: Bars
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
140 mm
170 mm
130 mm
2.1 kg
7320500500187
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85364900
Popular Downloads
Dimensions
140 mm
180 mm
225 mm
4.7 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
(690 V) 40 °C 600 A
(690 V) 55 °C 500 A
(690 V) 70 °C 400 A
(690 V) 40 °C 600 A
(690 V) 55 °C 500 A
(690 V) 70 °C 400 A
(415 V) 55 °C 370 A
(440 V) 55 °C 370 A
(500 V) 55 °C 315 A
(690 V) 55 °C 315 A
(380 / 400 V) 55 °C 370 A
(220 / 230 / 240 V) 55 °C 370 A
(415 V) 55 °C 370 A
(440 V) 55 °C 370 A
(500 V) 55 °C 315 A
(690 V) 55 °C 315 A
(380 / 400 V) 55 °C 370 A
(220 / 230 / 240 V) 55 °C 370 A
(415 V) 200 kW
(440 V) 200 kW
(500 V) 250 kW
(690 V) 315 kW
(380 / 400 V) 200 kW
(220 / 230 / 240 V) 110 kW
(415 V) 200 kW
(440 V) 200 kW
(500 V) 250 kW
(690 V) 315 kW
(380 / 400 V) 200 kW
(220 / 230 / 240 V) 110 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2960 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 1208 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1709 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions per Pole 27 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Main Circuit: Bars
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
175 mm
270 mm
223 mm
5.4 kg
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85364900
Popular Downloads
Dimensions
140 mm
180 mm
225 mm
4.7 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
(690 V) 40 °C 500 A
(690 V) 55 °C 400 A
(690 V) 70 °C 325 A
(690 V) 40 °C 500 A
(690 V) 55 °C 400 A
(690 V) 70 °C 325 A
(415 V) 55 °C 305 A
(440 V) 55 °C 305 A
(500 V) 55 °C 290 A
(690 V) 55 °C 290 A
(380 / 400 V) 55 °C 305 A
(220 / 230 / 240 V) 55 °C 305 A
(415 V) 55 °C 305 A
(440 V) 55 °C 305 A
(500 V) 55 °C 290 A
(690 V) 55 °C 290 A
(380 / 400 V) 55 °C 305 A
(220 / 230 / 240 V) 55 °C 305 A
(415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
(380 / 400 V) 160 kW
(220 / 230 / 240 V) 90 kW
(415 V) 160 kW
(440 V) 160 kW
(500 V) 200 kW
(690 V) 250 kW
(380 / 400 V) 160 kW
(220 / 230 / 240 V) 90 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2440 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 996 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 3050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 1409 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
5 million
300 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions per Pole 19 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Main Circuit: Bars
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
175 mm
270 mm
223 mm
5.4 kg
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85364900
Popular Downloads
Dimensions
111.5 mm
162.3 mm
196 mm
3.2 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
(690 V) 40 °C 275 A
(690 V) 55 °C 250 A
(690 V) 70 °C 180 A
(690 V) 40 °C 275 A
(690 V) 55 °C 250 A
(690 V) 70 °C 180 A
(415 V) 55 °C 205 A
(440 V) 55 °C 185 A
(500 V) 55 °C 170 A
(690 V) 55 °C 170 A
(380 / 400 V) 55 °C 205 A
(220 / 230 / 240 V) 55 °C 205 A
(415 V) 55 °C 205 A
(440 V) 55 °C 185 A
(500 V) 55 °C 170 A
(690 V) 55 °C 170 A
(380 / 400 V) 55 °C 205 A
(220 / 230 / 240 V) 55 °C 205 A
(415 V) 110 kW
(440 V) 90 kW
(500 V) 110 kW
(690 V) 132 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 59 kW
(415 V) 110 kW
(440 V) 90 kW
(500 V) 110 kW
(690 V) 132 kW
(380 / 400 V) 110 kW
(220 / 230 / 240 V) 59 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
5 million
3600 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions per Pole 5 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Main Circuit: Bars
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
180 mm
245 mm
175 mm
3.8 kg
7320500500323
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85364900
Popular Downloads
Dimensions
111.5 mm
162.3 mm
196 mm
3.2 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 250 A
(690 V) 40 °C 250 A
(690 V) 55 °C 230 A
(690 V) 70 °C 180 A
(690 V) 40 °C 250 A
(690 V) 55 °C 230 A
(690 V) 70 °C 180 A
(415 V) 55 °C 185 A
(440 V) 55 °C 145 A
(500 V) 55 °C 145 A
(690 V) 55 °C 120 A
(380 / 400 V) 55 °C 185 A
(220 / 230 / 240 V) 55 °C 185 A
(415 V) 55 °C 185 A
(440 V) 55 °C 145 A
(500 V) 55 °C 145 A
(690 V) 55 °C 120 A
(380 / 400 V) 55 °C 185 A
(220 / 230 / 240 V) 55 °C 185 A
(415 V) 90 kW
(440 V) 75 kW
(500 V) 90 kW
(690 V) 110 kW
(380 / 400 V) 90 kW
(220 / 230 / 240 V) 55 kW
(415 V) 90 kW
(440 V) 75 kW
(500 V) 90 kW
(690 V) 110 kW
(380 / 400 V) 90 kW
(220 / 230 / 240 V) 55 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 280 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 600 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 800 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
5 million
3600 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions per Pole 5 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Main Circuit: Bars
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
180 mm
245 mm
175 mm
3.8 kg
7320500500255
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85364900
Popular Downloads
Dimensions
102 mm
123.5 mm
148 mm
1.9 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
(690 V) 40 °C 145 A
(690 V) 55 °C 135 A
(690 V) 60 °C 135 A
(690 V) 70 °C 115 A
(690 V) 40 °C 145 A
(690 V) 55 °C 135 A
(690 V) 60 °C 135 A
(690 V) 70 °C 115 A
(415 V) 55 °C 96 A
(440 V) 55 °C 93 A
(500 V) 55 °C 80 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 96 A
(220 / 230 / 240 V) 55 °C 96 A
(415 V) 55 °C 96 A
(440 V) 55 °C 93 A
(500 V) 55 °C 80 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 96 A
(220 / 230 / 240 V) 55 °C 96 A
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(220 / 230 / 240 V) 25 kW
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(220 / 230 / 240 V) 25 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
10 million
3600 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 110 V
60 Hz 110 ... 120 V
50 Hz 110 V
60 Hz 110 ... 120 V
at Rated Operating Conditions per Pole 2.7 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Cable Clamp
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
140 mm
170 mm
130 mm
2.1 kg
7320500500033
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85369001
PSPCB
Popular Downloads
Dimensions
145 mm
255 mm
30 mm
0.503 kg
Technical
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
Product Not in WEEE Scope
Container Information
1 piece
280 mm
175 mm
85 mm
0.607 kg
7320500509692
External Classifications and Standards
V11.0 : 27371392
EC000249 - Protection switch disconnector housing
EC002498 - Accessories/spare parts for low-voltage switch technology
EC002498 - Accessories/spare parts for low-voltage switch technology

Ordering
1 piece
85364900
Popular Downloads
Dimensions
102 mm
123.5 mm
148 mm
1.9 kg
Technical
3
0
1
1
3P
Main Circuit 1000 V
Main Circuit 60 Hz
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 145 A
(690 V) 40 °C 145 A
(690 V) 55 °C 135 A
(690 V) 60 °C 135 A
(690 V) 70 °C 115 A
(690 V) 40 °C 145 A
(690 V) 55 °C 135 A
(690 V) 60 °C 135 A
(690 V) 70 °C 115 A
(415 V) 55 °C 96 A
(440 V) 55 °C 93 A
(500 V) 55 °C 80 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 96 A
(220 / 230 / 240 V) 55 °C 96 A
(415 V) 55 °C 96 A
(440 V) 55 °C 93 A
(500 V) 55 °C 80 A
(690 V) 55 °C 65 A
(380 / 400 V) 55 °C 96 A
(220 / 230 / 240 V) 55 °C 96 A
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(220 / 230 / 240 V) 25 kW
(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(220 / 230 / 240 V) 25 kW
8 x Ie AC-3
10 x Ie AC-3
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 800 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1320 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 500 A
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
8 kV
300 cycles per hour
10 million
3600 cycles per hour
(acc. to IEC 60947-4-1) Uc (at θ ≤ 70 °C)
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
50 Hz 220 ... 230 V
60 Hz 230 ... 240 V
at Rated Operating Conditions per Pole 2.7 W
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP40
Cable Clamp
Block Contactor
Environmental
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 55 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Without Derating 3000 m
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
box 1 piece
140 mm
170 mm
130 mm
2.1 kg
7320500500040
External Classifications and Standards
Q
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
EC000066 - Power contactor, AC switching
V11.0 : 27371003
39121529
4755 >> Contactors

Ordering
1 piece
85389099
Popular Downloads
Dimensions
50 mm
22.25 mm
55.1 mm
0.028 kg
Technical
IP20
ANYBUS
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
79.9 mm
73.5 mm
27.95 mm
0.042 kg
7320500505434
box 1 piece
External Classifications and Standards
Q
EC001604 - Fieldbus, decentr. periphery - communication module
EC001604 - Fieldbus, decentr. periphery - communication module
EC001604 - Fieldbus, decentr. periphery - communication module
V11.0 : 27242608
32151802
3587 >> Fieldbus, decentr. periphery - communication module

Ordering
1 piece
85389099
Popular Downloads
Dimensions
50 mm
22.25 mm
56.5 mm
0.028 kg
Technical
IP20
ANYBUS
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
79.9 mm
73.5 mm
27.95 mm
0.043 kg
7320500505366
box 1 piece
External Classifications and Standards
Q
EC001604 - Fieldbus, decentr. periphery - communication module
EC001604 - Fieldbus, decentr. periphery - communication module
EC001604 - Fieldbus, decentr. periphery - communication module
V11.0 : 27242608
32151802
3587 >> Fieldbus, decentr. periphery - communication module

Ordering
1 piece
85371091
Popular Downloads
Dimensions
435 mm
493 mm
369 mm
46.5 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 200 kW
(400 V) 400 kW
(500 V) 500 kW
(230 V) 200 kW
(400 V) 400 kW
(500 V) 500 kW
720 A
at 230 V 355 kW
at 400 V 710 kW
at 500 V 880 kW
at 230 V 355 kW
at 400 V 710 kW
at 500 V 880 kW
1247 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Main Circuit: Bars
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 45 N·m
PSTX720
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 250 Hp
(220 ... 240 V AC) Three Phase 300 Hp
(440 ... 480 V AC) Three Phase 600 Hp
(550 ... 600 V AC) Three Phase 700 Hp
(200 ... 208 V AC) Three Phase 250 Hp
(220 ... 240 V AC) Three Phase 300 Hp
(440 ... 480 V AC) Three Phase 600 Hp
(550 ... 600 V AC) Three Phase 700 Hp
Main Circuit 600 V
Main Circuit 398.3
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
600 mm
616 mm
800 mm
58.5 kg
7320500510384
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter

Ordering
1 piece
85371091
Popular Downloads
Dimensions
150 mm
314 mm
198 mm
4.7 kg
Technical
208 ... 600 V AC
100 ... 250 V AC
24 V DC
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(230 V) 30 kW
(400 V) 55 kW
(500 V) 75 kW
(230 V) 30 kW
(400 V) 55 kW
(500 V) 75 kW
105 A
at 230 V 55 kW
at 400 V 90 kW
at 500 V 110 kW
at 230 V 55 kW
at 400 V 90 kW
at 500 V 110 kW
181 A
100 %
Built-in electronic overload protection
Yes
4xIe for 10s
1 ... 120 second [unit of time]
10 ... 99 %
100 ... 10 %
1.5 ... 7.5 xle
Yes
Yes
Yes
Yes
Yes
0…10 V, 0…20 mA, 4…20 mA
Green
Green
Yellow
Red
Modbus-RTU; Modbus-TCP; Ethernet-IP; EtherCAT; DeviceNet; CANopen; Profibus; Profinet; BACnet-IP; BACnet-MSTP
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Cable Clamp
Hole Diameter 8.5 mm
Rigid 1 x 2.5 mm²
Rigid 1 x 2.5
Main Circuit 8 N·m
PSTX105
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Full voltage start
Jog with slow speed, forward and reverse
Keypad password
Kick start
Limp mode with two-phase motor control if one set of thyristors is shorted
Motor heating
Pre-start function
Pump cleaning
Real time clock
Sequence start
Soft start with torque control
Soft start with voltage ramp
Soft stop with torque control
Soft stop with voltage ramp
Stand still brake
Start reverse (external contactors)
Thyristor runtime measurement
Torque limit
Voltage sags detection
Auto phase sequence detection
Automatic restart
Current limit
Current limit ramp
Dual current limit
Dynamic brake
Electricity metering
Electronic overload Time-to-cool
Emergency mode
Event log
Bypass open protection; Current imbalance protection; Current underload protection; Dual overload (separate overload for start and run); Earth fault protection / ground fault protection; Electronic overload protection, EOL; Extension IO failure protection; Fieldbus failure protection; HMI failure protection; Locked rotor protection; Max number of starts/hour; Over voltage protection; Phase reversal protection; Power factor underload protection; PT-100 connection; PTC connection; Too long current limit protection; Too long start time protection; Under voltage protection; User defined protection; Voltage imbalance protection
Current imbalance warning; Current underload warning; Electronic overload Time-to-trip; EOL warning; Faulty fan warning; Locked rotor warning; Motor runtime limit warning; Over voltage warning; Phase loss warning (for standby); Power factor underload warning; Short circuit warning (for Limp mode); THD(U) - Total Harmonic Distortion warning; Thyristor overload warning (SCR); Under voltage warning; Voltage imbalance warning
Technical UL/CSA
(200 ... 208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
(200 ... 208 V AC) Three Phase 30 Hp
(220 ... 240 V AC) Three Phase 40 Hp
(440 ... 480 V AC) Three Phase 75 Hp
(550 ... 600 V AC) Three Phase 100 Hp
Main Circuit 600 V
Main Circuit 70.8
Environmental
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Operation -25 ... +60 °C
Storage -40 ... +70 °C
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
f3a0566c-5aad-4ac9-94d0-4c2d5492623c China
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
200 mm
282 mm
388 mm
5.7 kg
7320500501313
box 1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521
4740 >> Soft starter


Ordering
1 piece
8503009999
Popular Downloads
Dimensions
160 mm
260 mm
196 mm
4.8 kg
Technical
Main Circuit 208 ... 600 V AC
100 ... 250 V AC
DC Operation 24 V
50/60 Hz
Main Circuit 50 / 60 Hz
50/60 Hz
Main Circuit 50 / 60 Hz
(400 V) 22 kW
(500 V) 25 kW
(400 V) 22 kW
(500 V) 25 kW
44 A
at 400 V 37 kW
at 500 V 45 kW
at 400 V 37 kW
at 500 V 45 kW
76 A
115 %
Build-in electronic overload protection
Yes
3xIe for 15s
0 ... 120 second [unit of time]
1 ... 120 second [unit of time]
0 ... 120 second [unit of time]
1 ... 120 second [unit of time]
30 ... 70 %
100 ... 30 %
1.5 ... 7xIe
Yes
Yes
Yes
Yes
Yes
0…10 volts
0…20 mA
4…20 mA
0…10 volts
0…20 mA
4…20 mA
Green
Yellow
Red
30
FiledBusPlug(Standard)
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Screw Terminals
Rigid 1 x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
Rigid 1 x 10 ... 95 mm²
Rigid 2 x 6 ... 35 mm²
Rigid 1 x 2.5 mm²
Rigid 2 x 1.5 mm²
Rigid 1 x 2.5 mm²
Rigid 2 x 1.5 mm²
Rigid 1 x 2.5
Control Circuit 0.5 N·m
Main Circuit 6 N·m
Supply Circuit 0.5 N·m
Control Circuit 0.5 N·m
Main Circuit 6 N·m
Supply Circuit 0.5 N·m
PST44
Environmental
Operation 0 ... +50 °C
Storage -25 ... +70 °C
Operation 0 ... +50 °C
Storage -25 ... +70 °C
Material Compliance
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
190 mm
360 mm
280 mm
6 kg
7320500255520
1 piece
External Classifications and Standards
Q
EC000640 - Soft starter
EC000640 - Soft starter
EC000640 - Soft starter
V11.0 : 27370907
39121521

Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Environmental
Ordering
8056221085670
1 piece
85389099
Additional Information
Accessories for SACE FORMULA DSP
Accessory
ACC
P3
P4
P3
P4
SACE FORMULA DSP
Technical
Loose or configurable
IEC
Certificates and Declarations
External Classifications and Standards
5. Small Equipment (No External Dimension More Than 50 cm)

Ordering
10 piece
8536508090
Popular Downloads
Dimensions
0.03 m
0.03 m
0.06 m
0.025 kg
Technical
Operation -25 ... +70 °C
Storage -40 ... +85 °C
Operation -25 ... +70 °C
Storage -40 ... +85 °C
Yellow
Extended
Black Plastic
Illuminated
LED 24V AC/DC
Momentary
0
1
Type1
Type12
Type13
Type3R
Type4
Type4X
Type1
Type12
Type13
Type3R
Type4
Type4X
3
300 V
6 kV
50 / 60 Hz
Supply Circuit 50 / 60 Hz
50 / 60 Hz
Supply Circuit 50 / 60 Hz
24 V AC/DC
Maximum 300 V
Supply Circuit 24 V AC/DC
24 V AC/DC
Maximum 300 V
Supply Circuit 24 V AC/DC
(24 V) 0.3 A
(125 V) 0.2 A
(24 V) 0.3 A
(125 V) 0.2 A
(240 V) 2 A
(220 / 240 V) 2 A
(240 V) 2 A
(220 / 240 V) 2 A
Maximum 2.5 W
0.5 million
Flexible with Ferrule 1 x 0.5...1.5 mm²
Flexible with Ferrule 2 x 0.5...1.5 mm²
Flexible with Insulated Ferrule 1 x 0.5...1.5 mm²
Flexible with Insulated Ferrule 2 x 0.5...1.5 mm²
Flexible 1 x 0.5 ...1.5 mm²
Flexible 2 x 0.5 ...1.5 mm²
Solid 1 x 0.5...1.5 mm²
Solid 2 x 0.5...1.5 mm²
Flexible with Ferrule 1 x 0.5...1.5 mm²
Flexible with Ferrule 2 x 0.5...1.5 mm²
Flexible with Insulated Ferrule 1 x 0.5...1.5 mm²
Flexible with Insulated Ferrule 2 x 0.5...1.5 mm²
Flexible 1 x 0.5 ...1.5 mm²
Flexible 2 x 0.5 ...1.5 mm²
Solid 1 x 0.5...1.5 mm²
Solid 2 x 0.5...1.5 mm²
Screw Clamp
Screw Terminals
0.8 N·m
6 mm
Technical UL/CSA
1x 22...14 AWG
2x 22...14 AWG
1x 22...14 AWG
2x 22...14 AWG
Environmental
Front IP66
Front IP67
Front IP69K
Terminals IP20
Front IP66
Front IP67
Front IP69K
Terminals IP20
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Business To Business
5. Small Equipment (No External Dimension More Than 50 cm)
Certificates and Declarations
Container Information
bag 10 piece
0.125 m
0.235 m
0.05 m
0.254 kg
7320500381458
External Classifications and Standards
S
EC001028 - Push button, complete
EC001028 - Push button, complete
EC001028 - Push button, complete
V11.0 : 27371228
39122216
5212 >> Push button for distribution board
2312132
3717251