ABB EcoSolutions
Yes
Design for Closing Resource Loops - Standard EN45555 - 80.7 %
No non-hazardous waste is sent to a landfill
Product Durability
Take Back for Recycling
Technical
50 / 60 Hz - 1 min 2 kV
(230 V AC) 20 kA
(400 V AC) 10 kA
(440 V AC) 10 kA
(230 V) 20 kA
(400 V) 10 kA
(230 V AC) 20 kA
(400 V AC) 10 kA
(440 V AC) 10 kA
(230 V) 20 kA
(400 V) 10 kA
(230 V AC) 15 kA
(400 V AC) 7.5 kA
(440 V AC) 7.5 kA
(230 V AC) 15 kA
(400 V AC) 7.5 kA
(440 V AC) 7.5 kA
Arbitrary
Red ON / Green OFF
3
20000 AC cycle
20000 cycle
3
3P+N
Right
2.8 N·m
Toggle
Failsafe Bi-directional Cylinder-lift Terminal
I / O
Insulation Group II, Black, Sealable
Pozidriv 2
Yes
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
Busbar 10/10 mm²
Flexible with Ferrule 0.75 ... 25 mm²
Flexible 0.75 ... 25 mm²
Rigid 0.75 ... 35 mm²
Rigid 0.75 ... 35 mm²
Stranded 0.75 ... 35 mm²
acc. to DIN 43880 1
12.5 mm
Screw Terminals
Electrical
K
acc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 440 V AC
acc. to IEC 60898-1 400 V AC
acc. to IEC 60947-2 440 V AC
Maximum (Incl. Tolerance) 440 V AC
acc. to IEC/EN 60664-1 440 V
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
4 kV
at 2000 m 5 kV
at Sea Level 6.2 kV
AC
25 A
(AC) 6 kA
(DC) 6 kA
(AC) 6 kA
(DC) 6 kA
(230 V) 20 kA
(400 V) 10 kA
(230 V) 20 kA
(400 V) 10 kA
50 Hz
50 / 60 Hz
11.6 W
at Rated Operating Conditions per Pole 2.9 W
11.6 W
at Rated Operating Conditions per Pole 2.9 W
III
Design
Insulation Group II, RAL 7035
Technical UL/CSA
110 V DC
480Y / 277 V AC
110 V DC
480Y / 277 V AC
(110 V DC) 10 kA
(277 V AC) 6 kA
(480Y / 277 V AC) 6 kA
(110 V DC) 10 kA
(277 V AC) 6 kA
(480Y / 277 V AC) 6 kA
Busbar 18-8 AWG
Conductor 18-4 AWG
Busbar 18-8 AWG
Conductor 18-4 AWG
18 in·lb
Material Compliance
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
20240228
True - contains substances > 0.1 mass percentage
20250917
e6800e55-46b1-49a3-881b-0f66d0e903ad Germany
5. Small Equipment (No External Dimension More Than 50 cm)
Business To Business
Environmental
Operation -25 ... +55 °C
Storage -40 ... +70 °C
Operation -25 ... +55 °C
Storage -40 ... +70 °C
IP20
IP40
Enclosure with Cover IP40
IP20
IP40
Enclosure with Cover IP40
3
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
20 Cycles with Load 0.8 In: 5g 5 ... 150 ... 5 Hz
25g 2 shocks 13 ms
Dimensions
4.0
70 mm
88 mm
69 mm
0.455 kg
0.125 kg
69 mm
Engineering
Ordering
carton 1 piece
0.475 kg
3210934
1665464
Certificates and Declarations
Installation
DIN-Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
any
Popular Downloads
External Classifications and Standards
EC000042 - Miniature circuit breaker (MCB)
EC000042 - Miniature circuit breaker (MCB)
39121603
V11.0 : 27141901
4897 >> Miniature circuit breakers
F
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
IEC/EN 60898-1
IEC/EN 60947-2
UL 1077
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL
EN
IEC
UL

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Additional Information
-
0.00
United States
85352100
Spare_Parts
0 in³
0 lb
ELECT TO OPTIC TERM UNIT
No
ELECT TO OPTIC TERM UNIT
1 EA
1 EA
New
-
0 lb
Spare_Parts
No
each
-