3D Measurement Systems
120 products
Showing 97 - 120 of 120 products




Specifications
Model |
OP-88369 |
|||
Average active efficiency |
89% or more |
|||
Efficiency at low load (10%) |
79% or more |
|||
No-load power consumption |
0.15 W |
|||
Dimensions |
153 × 68 × 35 mm (excluding the cable) |
|||
Rating |
Input |
100 to 240 VAC 50/60 Hz 150 W |
||
Output |
24 VDC, 5 A (120 W max.) |
|||
Weight |
Approx. 650 g (excluding the AC cable) |
|||
Scroll





Specifications
Model |
OP-87946 |
|||
Type |
Target securing plate |
|||
Overview |
Four fixing bolts are included. Effective size is 290mm×240mm. |
|||
Applicable product |
XM-1000, XM-T1000, XM-1200, XM-T1200 |
|||
Scroll

Specifications
Model |
OP-87949 |
|||
Type |
Probe cable for replacement |
|||
Applicable product |
XM-1000, XM-T1000, XM-1200, XM-T1200 |
|||
Scroll

Specifications
Model |
OP-87947 |
|||
Type |
Stylus calibration jig |
|||
Applicable product |
XM-1000, XM-T1000, XM-1200, XM-T1200 |
|||
Note |
Optional standard parts for single item purchase |
|||
Scroll

Specifications
Model |
OP-87945 |
|||
Type |
Console |
|||
Applicable product |
XM-1000, XM-T1000, XM-1200, XM-T1200 |
|||
Length |
Cable length: 1.3 m 4.3' |
|||
Note |
Optional standard parts for single item purchase |
|||
Weight |
Approx. 150 g (including cable) |
|||
Scroll

Specifications
Model |
OP-87944 |
|||
Type |
Standard stylus |
|||
Applicable product |
XM-1000, XM-T1000, XM-1200, XM-T1200 |
|||
Number included |
1 |
|||
Note |
Optional standard parts for single item purchase |
|||
Scroll

Specifications
Model |
OP-87709 |
|||
Type |
Tilt stage |
|||
Note |
Free-angle observation and measurement without contact |
|||
Scroll

Specifications
Model |
NR-XU1 |
|||
Input |
100 to 240 VAC (50/60 Hz), 1.5 A |
|||
Output |
24 VDC, 3.75 A (90.0 W) |
|||
Average effective efficiency |
89.0% or more |
|||
Low load efficiency (10%) |
79.0% or more |
|||
Power consumption with no load |
0.15 W or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 460 g 16.24 oz |
|||
Scroll

Specifications
Model |
NR-XJ1 |
|||
Applicable battery |
NR-XB1 Series |
|||
Charging part |
Charging method |
Constant current and constant voltage method |
||
Charging time |
1 battery: Approx. 3.0 hours, 2 batteries: Approx. 4.5 hours |
|||
Display |
Charging confirmation LED |
Green LED (Flashing: charging, Constant: charging complete) |
||
Power supply |
NR-XU1 AC adapter |
|||
Environmental resistance |
Ambient temperature |
5 to 40°C 41°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 410 g 14.47 oz |
|||
Scroll

Specifications
Model |
NR-XB1A |
|||
Type |
Lithium-ion battery |
|||
Applicable models |
NR-XU15 Series |
|||
Nominal voltage |
14.4 V |
|||
Nominal capacity |
3.3 Ah |
|||
Number of charges/ discharges |
Approx. 300 times (at 80% full charge capacity) |
|||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 70% RH (no condensation) |
|||
Weight |
Approx. 240 g 8.47 oz |
|||
Scroll

Specifications
Model |
XM-T1200 |
|||
Type |
Measuring unit (2 probes) |
|||
Camera |
Image pickup device |
4 megapixel CMOS image sensor |
||
Wavelength at light receiving center |
Near-infrared |
|||
Measuring range |
600 mm × 300 mm × 200 mm 23.62" × 11.81" × 7.87" |
|||
Min. display unit |
Distance |
1 µm |
||
Angle |
0.0001 degrees |
|||
Measurement accuracy |
Repeatability |
Stage locked: ±3 µm |
||
Indication error |
Stage locked: ±8 µm*1 |
|||
Stage |
Withstand load |
25 kg |
||
X-axis movable range |
±100 mm ±3.94" |
|||
Rotation range |
±60° |
|||
Probe |
No. of probes |
2 |
||
Stage marker |
No. of markers |
6 |
||
Marker light source |
Near-infrared LED (870 nm) |
|||
Probe connection port |
2 inputs |
|||
Console input |
Dedicated console |
|||
External remote input |
Non-voltage input (with and without tangent point): 2 inputs |
|||
Interfaces |
Communication (external communication) |
USB 2.0 Series A: 3 ports |
||
Display |
Built-in display |
15" LCD monitor (1024 × 768) |
||
Environmental resistance |
Ambient temperature |
+10 to +35 °C 50 to 95 °F |
||
Relative humidity |
20 to 80 % RH (No condensation) |
|||
Power supply |
Power supply voltage |
Supplied from controller |
||
Connector type |
Dedicated connector |
|||
Weight |
Head: Approx. 39.6 kg (including camera and cable) |
|||
*1 In reference to ISO 10360-2 (within the range of 200 × 200 × 150 mm 7.87" × 7.87" × 5.91" at an operating ambient temperature of 23 ±1°C 73.4 ±1.8°F) | ||||
Scroll

Specifications
Model |
XM-1600 |
|||
Type |
Controller |
|||
HDD |
500 GB |
|||
Interfaces |
Measuring unit |
Dedicated cable |
||
Communication (external communication) |
RS-232C |
|||
Display |
External output |
DVI-D |
||
Power supply |
100 to 240 VAC 50/60 Hz |
|||
Power consumption |
250 VA max. |
|||
Environmental resistance |
Ambient temperature |
+10 to +35°C 50 to 95°F |
||
Relative humidity |
20 to 80% RH (no condensation) |
|||
Weight |
Approx. 7.7 kg |
|||
Scroll

Specifications
Model |
XM-1500 |
|||
Type |
Controller |
|||
HDD |
320 GB |
|||
Interfaces |
Measuring unit |
Dedicated cable |
||
Communication (external communication) |
RS-232C |
|||
Display |
External output |
DVI-D |
||
Measuring mode |
Program mode/Run mode/Statistic analysis/Single measurement |
|||
No. of configurable elements |
500 (excluding comment elements) |
|||
Maximum measurement points |
200 points (per element) |
|||
Basic |
Measurement between elements |
Distance/Angle/Calculation |
||
Basic elements |
Plane/Line/Point/Circle/Cylinder/Cone/Sphere |
|||
Particular measurement element |
Point - no correction/Ellipse/Single point circle/Stepped cylinder/Oval/Round slot/Corner arc/Chamfer line/Torus |
|||
Virtual figures |
Point |
Midpoint/Contact point/Intersection/Perpendicular/Numerical input/Element specification |
||
Line |
Median line/Tangent line/Intersect line/Projection line/Rotation line/Numerical input/Element specification |
|||
Plane |
Median plane/Parallel plane/Numerical input/Element specification |
|||
Circle |
Intersect circle/Numerical input/Element specification |
|||
GD&T |
Form |
Flatness/Roundness/Straightness/Cylindricity |
||
Orientation |
Parallelism/Perpendicularity/Angularity |
|||
Location |
Position/Concentricity/Coaxiality/Symmetry |
|||
Coordination |
New |
Simple coordinate/Type A coordinate/Type B coordinate/Specified coordinate |
||
Change |
Base plane settings/Fit axis to point/Fit axis to line/Rotate axis/Fix axis to offset point/Set origin/Reset coordinate |
|||
Work adjust. |
Work adjust |
|||
Apps |
Distance |
Plane-to-point height/Plane-to-plane distance/Hole position |
||
Angle |
Dihedral angle/Edge to edge angle |
|||
Diameter |
Diameter/Pitch circle diameter/Lower diameter/Upper diameter |
|||
Position |
Hole position/V groove |
|||
Batch settings |
Batch tolerance settings/Batch settings for output/display Items/Guidance image batch settings/List edit |
|||
No. of measurement macro settings |
100 |
|||
No. of probe settings |
10 |
|||
Average times of measurement |
1/2/4/8/16 |
|||
Check measurement position |
Available |
|||
Print/file output |
Inspection specifications/Single object report/Single object report (with guidance image)/Screen image/Graphic display image/Probe camera image/CSV output |
|||
Import/Export |
Move/Copy/Delete |
|||
Other |
Comment/Other measurement results |
|||
Environmental resistance |
Ambient temperature |
+10 to +35 °C 50 to 95 °F |
||
Relative humidity |
20 to 80 % RH (No condensation) |
|||
Power supply |
Power supply voltage |
100 to 240 VAC 50/60 Hz |
||
Power consumption |
250 VA max. |
|||
Weight |
Approx. 7.7 kg |
|||
Scroll


Specifications
Model |
XM-T1000 |
|||
Type |
Measuring unit (2 probes) |
|||
Camera |
Image pickup device |
4 megapixel CMOS image sensor |
||
Wavelength at light receiving center |
Near-infrared |
|||
Measuring range |
300 mm × 250 mm × 150 mm 11.81" × 9.84" × 5.91" |
|||
Min. display unit |
Distance |
1 µm |
||
Angle |
0.0001 degrees |
|||
Measurement accuracy |
Repeatability |
Stage locked: ±3 µm |
||
Indication error |
Stage locked: ±8 µm*1 |
|||
Stage |
Withstand load |
25 kg |
||
X-axis movable range |
- |
|||
Rotation range | ||||
Probe |
No. of probes |
2 |
||
Stage marker |
No. of markers |
- |
||
Marker light source | ||||
Probe connection port |
2 inputs |
|||
Console input |
Dedicated console |
|||
External remote input |
Non-voltage input (with and without tangent point): 2 inputs |
|||
Interfaces |
Communication (external communication) |
USB 2.0 Series A: 3 ports |
||
Display |
Built-in display |
15" LCD monitor (1024 × 768) |
||
Environmental resistance |
Ambient temperature |
+10 to +35 °C 50 to 95 °F |
||
Relative humidity |
20 to 80 % RH (No condensation) |
|||
Power supply |
Power supply voltage |
Supplied from controller |
||
Connector type |
Dedicated connector |
|||
Weight |
Head: Approx. 28.2 kg (including camera and cable) |
|||
*1 In reference to ISO 10360-2 (within the range of 200 × 200 × 150 mm 7.87" × 7.87" × 5.91" at an operating ambient temperature of 23 ±1°C 73.4 ±1.8°F) | ||||
Scroll

Specifications
Model |
XM-P1000*1 |
|||
Type |
Probe |
|||
Stage marker |
No. of markers |
7 |
||
Marker light source |
Near-infrared LED (870 nm) |
|||
Applicable stylus |
M4 (Commercially available styluses can be used) |
|||
Camera |
Compact CMOS image sensor |
|||
Status LED |
Green: Measurement possible |
|||
Housing material |
Marker body |
Quartz glass |
||
Probe housing |
PBT plastic |
|||
Weight |
Approx. 370 g (including the cable) |
|||
*1 Included with XM-1000/XM-T1000/XM-1200 and XM-T1200 models. | ||||
Scroll