Specifications
Model |
NR-X100W |
|||
Main unit buffer memory capacity |
50M data*1 |
|||
Expansion memory |
SD card (SD/SDHC)*2 |
|||
PC interface |
USB |
USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch) |
||
Ethernet |
RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3 |
|||
Wireless LAN |
Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3 |
|||
Network function |
FTP client function, FTP server function, SNTP client function |
|||
Display/operation |
Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection |
|||
Expansion remote unit connection |
Dedicated remote connection connector × 2 (Remote OUT A port, B port) |
|||
Number of connectable measurement units |
Master data collection unit group |
Max. 8 units*4 |
||
Total with remote units connected |
Max. 72 units*5 |
|||
Continuous acquisition speed |
Master data collection unit group |
Max. 100 kHz for all acquisition channels *6 |
||
Total with remote units connected |
Max. 500 kHz for all acquisition channels *6*7 |
|||
Inter-unit synchronization |
Between measurement units in the master data collection unit group |
±1 μs or less *8 |
||
Between the master data collection unit and each remote unit / environment-resistant measurement unit | ||||
Time axis accuracy |
±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible |
|||
Synchronous trigger input (SYNC input) |
Performance specifications |
• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode) |
||
Input specifications |
• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower |
|||
Control input |
Common specifications |
• Input type: Bidirectional voltage input |
||
Individual specifications |
• External trigger input (TRG IN): Edge input |
|||
Control output |
Common specifications |
• Output format: Photo MOS relay output |
||
Individual specifications |
• Trigger output (TRG OUT): N.O. output, one-shot output |
|||
Power supply |
• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less) |
|||
Power supply |
Power consumption |
8.4 W or less (excluding connected units) |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block)) |
|||
*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M. | ||||

Specifications
Model |
SV-C5F |
|||
Type |
Motor power cable, Standard |
|||
Length |
5 m 16.4' |
|||
Note |
for 3 kW / 5 kW motor |
|||

Specifications
Model |
OP-83202 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V88H, SL-V44L |
|||
Number included |
1 pcs. |
|||
Length |
1,750.2 mm 68.91" |
|||
Material |
Translucent plastic: Polycarbonate Black plastic: ABS |
|||
Note |
To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42 |
|||

Specifications
Model |
CL-PT010N |
|||
Type |
Optical unit |
|||
Head |
CL-PT010 *1 |
|||
Reference distance |
10 mm 0.39" |
|||
Reference measurement range |
Measurement range |
±0.3 mm ±0.01" |
||
Linearity |
±0.22 μm ±0.000009" *2 |
|||
High precision measurement range |
Measurement range |
±0.15 mm ±0.01" |
||
Linearity |
±0.2 μm ±0.000008" *2 |
|||
Resolution |
0.25 μm 0.000010" *3 |
|||
Spot diameter |
ø3.5 μm ø0.000138" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP64 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Operating ambient temperature |
Head |
0 to 50°C 32 to 122°F |
||
Optical unit | ||||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 0.45 mm 0.02" 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Vacuum |
None |
|||
Explosion-proof |
performance |
Head |
||
Optical unit | ||||
Zone/Division |
Head |
|||
Optical unit | ||||
Ambient temperature |
Head |
|||
Optical unit | ||||
Certification number | ||||
Temperature characteristic |
Head |
0.1% of F.S./°C *4 |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 1100 g 2.43 lb |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

Specifications
Model |
SZ-V32NCX *1 |
|||
Type |
Network Type (CIP Safety) |
|||
Detection capability |
Minimum detectable object size |
Diameter 20, 30, 40, 50, 70, 150 mm 0.79", 1.18", 1.57", 1.97", 2.76", 5.91" (depends on the setting) Reflectance 1.8% min., Speed 1.6 m/s 5.25 ft/s max. *2 |
||
Detectable angle |
190° ( -5° to 185° ) |
|||
Response time (ON to OFF) |
Standard Mode |
Scan Cycle A |
160 ms (2scans) to 1280 ms (16scans) *3 *4 |
|
Scan Cycle B |
168 ms (2scans) to 1344 ms (16scans) *3 *4 |
|||
Scan Cycle C |
176 ms (2scans) to 1408 ms (16scans) *3 *4 |
|||
High Speed Mode |
Scan Cycle A |
80 ms (2scans) to 640 ms (16scans) *3 *4 |
||
Scan Cycle B |
84 ms (2scans) to 672 ms (16scans) *3 *4 |
|||
Scan Cycle C |
88 ms (2scans) to 704 ms (16scans) *3 *4 |
|||
Response time (OFF to ON) |
Response time (ON to OFF) + 150 ms |
|||
Protection zone |
Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" |
8.4 m 27.56' (Standard Mode) 5.7 m 18.70' (High Speed Mode) |
||
Minimum detectable object size: 50 mm 1.97" |
5.6 m 18.37' (Standard Mode) 3.8 m 12.47' (High Speed Mode) |
|||
Minimum detectable object size: 40 mm 1.57" |
4.3 m 14.11' (Standard Mode) 2.9 m 9.51' (High Speed Mode) |
|||
Minimum detectable object size: 30 mm 1.18" |
2.9 m 9.51' (Standard Mode) 2.0 m 6.56' (High Speed Mode) |
|||
Minimum detectable object size: 20 mm 0.79" |
1.6 m 5.25' (Standard Mode) 1.1 m 3.61' (High Speed Mode) |
|||
Warning zone |
Minimum detectable object size: 70 / 150 mm 2.76" / 5.91" |
26 m 85.30' (Standard Mode) 23 m 75.46' (High Speed Mode) *5 |
||
Minimum detectable object size: 50 mm 1.97" |
25 m 82.02' (Standard Mode) 21 m 68.90' (High Speed Mode) *5 |
|||
Minimum detectable object size: 40 mm 1.57" |
24 m 78.74' (Standard Mode) 20 m 65.62’ (High Speed Mode) *5 |
|||
Minimum detectable object size: 30 mm 1.18" |
23 m 75.46' (Standard Mode) 18 m 59.06' (High Speed Mode) *5 |
|||
Minimum detectable object size: 20 mm 0.79" |
21 m 68.90' (Standard Mode) 15 m 49.21' (High Speed Mode) *5 |
|||
Additional safety distance |
100 mm 3.94" *6 |
|||
Maximum measurement distance |
60 m 196.85' *7 |
|||
Maximum number of banks |
Max.16 banks |
|||
Multiple scanner heads |
Max. 3 scanner heads |
|||
Camera monitoring area |
Monitor area: over 190° (-5° to 185°) *8 |
|||
Display |
QVGA 2.2inch color LCD |
|||
Light source |
Type, wavelength |
Infrared laser diode, 905 nm |
||
Laser Class |
IEC |
Class1 IEC/EN60825-1 |
||
FDA |
Class1 FDA 21CFR 1040.10, 1040.11 (Laser Notice) *9 |
|||
JIS |
Class1 JIS C6802 |
|||
Control output (OSSD) |
Output |
- |
||
Number of outputs | ||||
Max. load current | ||||
Residual voltage (during ON) | ||||
OFF-state voltage | ||||
Leakage current | ||||
Max. capacitive load | ||||
Load wiring resistance | ||||
Inputs |
PNP |
|||
NPN | ||||
Non-safety related output (AUX output) |
Output type |
|||
Number of outputs | ||||
Max. load current | ||||
Residual voltage (during ON) | ||||
Muting lamp | ||||
Interface |
USB |
USB2.0 |
||
Ethernet |
Standard |
IEEE802.3u (100 BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
STP(Shielded Twisted Pair) |
|||
Connector |
RJ45 (IP65) 2 ports |
|||
Network function |
CIP Safety, EtherNet/IP™, UDP |
|||
Cable length |
Power and I/O cable |
30 m 98.43' or less *10 |
||
Between scanner head and display unitc |
20 m 65.62' or less each *11 |
|||
Ethernet cable |
100 m 328.08' or less *12 |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE) |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 3 ESPE), IEC61496-3, EN61496-3 (Type 3 AOPDDR), IEC61508, EN61508, |
|||
Rating |
Power consumption |
13.4 W |
||
Power voltage |
24 VDC ±10% (Ripple P-P 10% or less): When using a converter power supply, 24 VDC +20%/-30%: When using a battery |
|||
Environmental resistance |
Enclosure rating |
IP65(IEC60529) |
||
Ambient light |
Incandescent lamp: 1500 lux or less *13 |
|||
Operating ambient temperature |
-10 to +50°C 14 to 122°F (No freezing) |
|||
Operating relative humidity |
35% to 85% RH (No condensation) |
|||
Storage temperature |
-25 to +60°C -13 to +140°F (No freezing) |
|||
Storage relative humidity |
35% to 95% RH |
|||
Vibration resistance |
10 to 55 Hz, 0.7 mm 0.03" compound amplitude, 20 sweeps each in X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 328.08 ft/s2 (Approx. 10 G) 16 ms pulse, in X, Y, Z directions 1000 times each axis |
|||
Material |
Scanner head |
Main unit case |
Magnesium |
|
Window |
Polycarbonate, PEI |
|||
Indicator part |
Aluminum, PES |
|||
Display unit |
Case |
Magnesium, PPS, Polycarbonate |
||
System memory |
Aluminum, PPE |
|||
Weight |
Approx. 2300 g |
|||
*1 Integrated models include display unit, scanner head, system memory and a connection cable (SZ-VS005). | ||||

Specifications
Model |
GL-SA20S |
|||
Type |
Protection cover Slim type for 20 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S20SH |
|||
Number included |
1 |
|||
Length |
422.6 mm 16.64" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
140 g |
|||

Specifications
Model |
SH-302*1 |
|||
Type |
Standard Shielded Cylindrical |
|||
Shape |
ø2.8×12 Cylindrical |
|||
Detectable object |
Ferrous metal (see Characteristics for nonferrous metals) |
|||
Standard target (iron, t=1 mm 0.04") |
5 x 5 mm 0.20"*2 |
|||
Stable detecting range |
0 to 0.6 mm 0.02" |
|||
Maximum detecting distance |
1.6 mm 0.06" |
|||
Repeatability |
0.001 mm 0.00004"*2 |
|||
Hysteresis |
0.03 mm 0.001"*2 |
|||
Temperature characteristics |
0.3%/°C*2 |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 30 g |
|||
*1 The SH-302 cannot be used in combination with the EG-547. | ||||

Specifications
Model |
FU-21 |
|||
Detecting method |
Diffuse Reflective |
|||
Size |
M3 |
|||
Detection arrangement |
Coaxial |
|||
Fibre unit length |
50 cm19.685" cannot be cut |
|||
Shape |
Straight |
|||
Minimum bend radius |
R25 mm0.984" |
|||
Detection distance |
7 mm0.276"*1 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 4 g |
|||
*1 The detecting distance is a value for white mat paper (the standard detection object) detections. | ||||

Specifications
Model |
SC-S11 |
|||
Response time |
25 ms (safety output ON to OFF, IEC/EN60204-1 stop category 0), 70 ms (safety output OFF to ON) |
|||
Safety output (S-OUTPUT) |
Output |
Two PNP outputs |
||
Max. load current |
500 mA |
|||
Residual voltage (when ON) |
2.5 V maximum (with a load current of 500 mA) |
|||
Leakage current |
1.2 mA maximum |
|||
Max. capacitive load |
2.2 µF (with a load resistance of 100 Ω) |
|||
Load wiring length |
30 m maximum |
|||
Safety input (S-INPUT, enable input) |
Input type |
Contact output device connection or PNP output device connection |
||
Short-circuit current |
Approx 5mA |
|||
ON/OFF voltage |
Voltage when product turned on: 19 V or more, voltage when product turned off: 5 V or less |
|||
Wiring length |
30 m maximum |
|||
Safety related input |
Input type |
Non-voltage contact input (EDM input, reset input) |
||
Short-circuit current |
EDM input: Approx. 10 mA, Reset input: Approx. 5 mA (EDM input, reset input) |
|||
Wiring length |
30 m max. (EDM input, reset input) |
|||
Non-safety output |
Output |
PNP/NPN totem pole output (auxiliary output, lockout output) |
||
Max. load current |
50mA (auxiliary output, lockout output) |
|||
Load wiring length |
10 m maximum (auxiliary output, lockout output) |
|||
Non-safety input |
Input type |
No-voltage contact input or PNP or NPN open-collector input (external off input) |
||
Short-circuit current |
Approx 5mA (external off input) |
|||
ON/OFF voltage |
Voltage when product turned on: 5 V or less or 19 V or more, voltage when product turned off: open or 9 V to 15 V (external off input) |
|||
Wiring length |
10 m maximum (external off input) |
|||
Protection circuit |
Power supply reverse polarity protection, overcurrent protection for each output, short-circuit protection , surge protection |
|||
Approved standards |
EMC |
EMS |
IEC 61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part 15 Class A, ICES-003 Issue 4 Class A |
|||
Safety |
ISO13849-1:2015 (category 4, PLe), UL1998, IEC/EN61496-1, UL508,*1 |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
1.3 A (at maximum load) |
|||
Environmental resistance |
Enclosure rating |
IP20 (IEC60529) |
||
Pollution degree |
2 (IEC60664/EN50178) |
|||
Overvoltage category |
2 (IEC60664, EN50178) |
|||
Insulation resistance |
100 MΩ or more (tested with a 500 VDC megger) between the internal circuit and the external case |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-20 to +65 °C -4 to 149 °F (No freezing) |
|||
Storage relative humidity |
35 to 85 % RH |
|||
Withstand voltage |
1,500 VAC, 50/60 Hz for 1 minute between the internal circuit and the external case |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Polycarbonate (UL94-V2) |
||
Weight |
160 g or less |
|||
*1 The following mark is displayed on the ratings indication label on the side of the main unit to identify it as a UL508-certified product. | ||||

Specifications
Model |
KV-NC32ETP |
|||
Expansion output unit |
External connectionmethod |
MOSFET (With overcurrent protection function)*1*2 |
||
External connection method |
Connector |
|||
Rated load |
30 VDC. 0.2 A *3 |
|||
Leakage current (when output is OFF) |
100 μA or less |
|||
Residual voltage (at ON) |
0.6 VDC or less |
|||
ON resistance |
− |
|||
Common method |
32 points/1 common (2 terminals)*4*5 |
|||
Response time |
OFF to ON |
100 μs or less (with a load of 1 mA or more) |
||
ON to OFF |
200 μs or less (with a load of 1 mA or more) |
|||
Relay life |
− |
|||
Relay replacement | ||||
Internal current consumption |
50 mA or less |
|||
Weight |
Approx. 110 g |
|||
*1 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic recovery are repeated for all outputs within the shared common (The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 015 or 100 to 115 for the KV-NC32ET(P).) , until the cause of the problem is removed. | ||||


PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LV-11SA |
|||
Type |
Main unit |
|||
Main unit/expansion unit | ||||
Applicable model |
LV-S61/S41/S41L/S31/S71/S72 |
|||
Control output |
NPN open-collector × 2 channels, 40 VDC maximum, 100 mA or less per output |
|||
Response time |
ExceptLV-S31 |
ULTRA |
4 ms |
|
SUPER |
2 ms |
|||
TURBO |
500 µs |
|||
FINE |
250 µs |
|||
HSP |
80 µs |
|||
LV-S31standard mode |
500 µs |
|||
LV-S31standard mode |
SPED2 |
2 ms |
||
SPED3 |
8 ms |
|||
SPED4 |
32 ms |
|||
LV-S31High-speed mode |
250 µs |
|||
Control input |
Light emission stop input, external calibration, set value bank selection input, or received light intensity shift input |
|||
Number of interference prevention units |
ULTRA |
― |
||
SUPER | ||||
TURBO | ||||
FINE | ||||
HSP | ||||
Unit expansion | ||||
Rating |
Power voltage |
12 to 24 VDC, Ripple (P-P) 10 % or less, Class2*1 |
||
Power consumption |
Normal |
1.5 W or less (62.5 mA or less at 24 V) |
||
Eco-Half Eco-All |
1.35 W or less (57.3 mA or less at 24 V) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*2 |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Main unit |
Main body, cover: Polycarbonate |
||
Weight |
Approx. 80 g (including 2 m 6.6' cable) |
|||
*1 When more than 8 units connected, be sure to use supply voltage 24 VDC Ripple (P-P) 10 % or less | ||||

Specifications
Model |
OP-88507 |
|||
Type |
High-flex |
|||
Sensor Side |
M8 4-Pin Straight |
|||
Cable Connector |
Loose wires |
|||
Length |
10 m 32.8' |
|||
Material |
Cable: PVC, Connector: Nickel-plated brass |
|||
Weight |
Approx. 370 g |
|||

Specifications
Model |
OP-87287 |
|||
Overview |
O-ring used between the sensor main body of GP-M Series and the adapter. |
|||
Applicable product |
GP-M001/M010/M025 |
|||
Number included |
1 pcs. |
|||
Material |
FKM |
|||


Specifications
Model |
SI-F1001*1 |
|||
Type |
Main Controller Separate type*2 |
|||
No. of connectable spectrum units |
2 |
|||
Display |
Minimum display unit |
0.001 µm |
||
Display range |
±999.999 µm to ±9999.99 mm (7 settings selectable) |
|||
Display cycle |
10 times/sec. |
|||
Terminal block |
Laser remote interlock input |
Non-voltage input*3 |
||
TIMING1 input | ||||
RESET1 input | ||||
Auto-zero1 input | ||||
Laser control input | ||||
Analog voltage output |
±10 V x 2 outputs, Output impedance: 100 Ω*3 |
|||
Analog current output |
4 to 20 mA x 2 outputs, Maximum load resistance: 350 Ω*3 |
|||
Alarm output |
NPN open-collector output (N.C.)*3 |
|||
General comparator output |
NPN open-collector output*3 |
|||
Expansion connector |
TIMING2 input |
Non-voltage input*3 |
||
RESET input | ||||
Auto-zero input | ||||
Program switch input |
Non-voltage input x 3 inputs*3 |
|||
Alarm output |
NPN open-collector output (N.C.)*3 |
|||
Comparator/ binary output |
Binary output |
Measured value data output (21 bits) OUT selectable NPN open-collector output*3 |
||
Strobe output |
NPN open-collector output*3 |
|||
Binary selection output | ||||
Binary selection input |
Non-voltage input*3 |
|||
RS-232C interface |
Measured data output and control input/output (Baud rate selectable to 115,200 bps max.) |
|||
USB interface |
USB 2.0 high speed compliant (USB 1.1 Full-SPEED compatible) |
|||
Ethernet interface |
100Base-TX/10Base-T |
|||
Major functions |
12 Out simultaneous measurement |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption |
One head connected: 0.6 A or less. Six heads connected: 1.5 A or less. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F*4 |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.5 mm 0.02", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 600 g |
|||
*1 The SI-F1003 can be used independently, The measured value display and setting change can be done with the display panel(SI-FD500) and setup support software(SI-H3). | ||||

Specifications
Model |
GL-SA32F |
|||
Type |
Protection cover Flat type for 32 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S32FH |
|||
Number included |
1 |
|||
Length |
662.6 mm 26.09" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
210 g |
|||

Specifications
Model |
OP-82488 |
|||
Type |
Power cable |
|||
Applicable product |
FT Series |
|||
Length |
2 m 6.56' |
|||
Note |
Included with amplifier |
|||
Weight |
Approx. 55 g |
|||

Specifications
Model |
GL-R23F |
|||
Detection capability |
ø0.55" ø14 mm |
|||
Total length |
9.45" 240mm |
|||
No. of beam |
23 |
|||
Detection height |
8.66" 220mm |
|||
Protection height |
9.61" 244mm |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39" / ø4 ø0.16" |
|||
Detecting distance |
0.66 to 32.81' 0.2 to 10 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
6.9 |
|
OFF→ON |
49.2*2 |
|||
All blocked→ON |
64.4*3 |
|||
Optical synchronization system |
ON→OFF |
9.3 |
||
OFF→ON |
52.7*2 |
|||
All blocked→ON |
74*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
50 |
||
Receiver |
70 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
320 g |
||
Receiver |
330 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
FU-48*1 |
|||
Size |
ø3 mm0.118" |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.0×2 |
|||
Minimum bend radius |
R4 mm0.157" high-flex |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +70 °C -40 to 158 °F |
||
Weight |
Approx. 7 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||