Specifications
Model |
MP-FG20R |
|||
Type |
Standard model |
|||
Connection bore diameter |
G1/2" (15A) |
|||
Supported gases |
Air and non-corrosive gases |
|||
Supported gas temperature |
-5 to +50°C, 23 to 122°F |
|||
Operating pressure range |
0.2 to 1 MPa, 2 to 10 bar, 29 to 145 psi *1 |
|||
Pressure resistance |
1.5 MPa, 15 bar, 217.5 psi |
|||
Flow rate |
Detection principle |
Heat based (mass flow rate) |
||
Rated flow range (normal) |
4 to 2000 L/min |
|||
Zero cut flow rate |
4 L/min, 0.2 m3/h 7.06 ft3/h, 0.1 CFM |
|||
Measurement accuracy |
±(1.5% of RD + 0.5% of F.S.) *2 *3 |
|||
Repeatability |
±1.0% of F.S. (with an averaging time of 1.0 s) |
|||
Display resolution |
1 L/min, 0.1 m3/h 3.53 ft3/h, 0.1 CFM |
|||
Response time |
150 ms (63% response) *4 |
|||
Averaging time |
OFF/100 ms/200 ms/500 ms/1.0 s/3.0 s/5.0 s/10 s/30 s (selectable) |
|||
Pressure (Digital value, gauge pressure) |
Rated pressure range |
0.000 to 1.000 MPa, 0.00 to 10.00bar, 0.0 to 145.0 psi |
||
Measurement accuracy |
±2.0% of F.S. |
|||
Repeatability |
±0.2% of F.S. (with a response time of 50 ms) |
|||
Display resolution |
0.001 MPa, 0.01 bar, 0.1 psi |
|||
Response time |
Selectable from 10 ms, 50 ms, 100 ms, 500 ms, 1.0 s, and 5.0 s *4 |
|||
Humidity (Dew point) |
Rated relative humidity range/ dew point range |
15 to 100%RH (no condensation)/Corresponds to the relative humidity range *5 *6 |
||
Measurement accuracy |
±4°C, ±7°F *5 *6 |
|||
Display resolution |
5%RH/1°C, 1°F *5 *6 |
|||
Temperature |
Measurement accuracy |
±2.0°C, ±3.6°F *7 |
||
Display resolution |
0.1°C, 0.1°F *7 |
|||
Shut-off valve |
Response time |
1 s or less (closed → open) |
||
Leakage amount |
50 mL/min 0.002 CFM (N) or less |
|||
Filter/regulator (Standard model only) |
Pressure adjustment range |
0.15 to 0.90 MPa |
||
Filtration degree |
5 μm 0.196850 Mil |
|||
Drainage cup capacity |
100 cc |
|||
Check valve |
Available |
|||
Display |
Color LCD, status indicator |
|||
Data accumulation |
Accumulation period |
Accumulated data: approx. 2 years/Instantaneous data: approx. 2 weeks |
||
Data reading |
USB 2.0/Ethernet |
|||
I/O |
Control output (Ch.1/2/3/4/5) |
NPN/PNP setting switchable, open collector output 30 VDC or less, N.O./N.C. setting switchable, max. 100 mA/Ch., residual voltage: 2.5 V or less |
||
Analog output (Ch.1/2) |
4 to 20 mA, load resistance: 260 Ω or less *4 |
|||
External input (Ch.2/3/6) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, reverse connection protection for each I/O, surge protection for each I/O, overcurrent protection for each output |
|||
Power supply |
Power voltage |
24 VDC +25%/-20% (including ripple), Class 2 or LPS |
||
Power consumption |
1.2 A (300 ms) when opening/closing valve, 100 mA at all other times *8 (standalone usage; excluding load current) |
|||
Communication interface |
USB2.0 |
|||
Network compatibility |
When using only this unit: IO-Link (Specification v1.1/COM3) *9 |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) *10 |
||
Ambient temperature |
−5°C to +50°C 23°F to 122°F (no freezing) *11 |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; power spectral density: 0.204 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
300 m/s2, XYZ axes, 10 times for each axis |
|||
Material |
Sensor part : PET/PPS/PBT/POM/aluminum/SPHC |
|||
Weight |
Approx. 1900 g 67.02 oz (excluding drainage cup) |
|||
*1 An upstream side pressure of 0.2 MPa or less (a filter/regulator adjustment pressure of 0.2 MPa or less for the standard model) worsens the flow rate characteristic of the shut-off valve. | ||||



Specifications
Model |
TM-3000 |
|||
Head compatibility |
Compatible |
|||
Number of connectable sensors |
2 units max.*1 |
|||
Display |
Minimum display unit |
0.01 µm, 0.001 mm2, 0.01 ° |
||
Maximum display range |
±9999.99 mm ±393.7", ±99999.9 mm2, ±99999.9° |
|||
Input terminal block |
Laser remote interlock input |
Non-voltage input*2 |
||
Trigger input (for Head A) | ||||
Timing 1 input | ||||
Auto-zero 1 input | ||||
Reset input | ||||
Output terminal block |
Analog voltage output |
±10 V x 2 outputs, out put impedance: 100 Ω*2 |
||
Total judgment output |
NPN open-collector output*2 |
|||
Error output |
NPN open-collector output (N.C.)*2 |
|||
Process output |
NPN open-collector output*2 |
|||
Trigger input enable output | ||||
Adjusted error output | ||||
Expansion connector |
Trigger input (for Head A) |
Non-voltage input*2 |
||
Timing 2 input | ||||
Auto-zero 2 input | ||||
Program switching input |
Non-voltage input, 4 inputs*2 |
|||
Memory card save input |
Non-voltage input*2 |
|||
Judgment/Binary output |
3-level judgment output: OUT1 to OUT16, total judgment output |
|||
Strobe output |
NPN open-collector output*2 |
|||
Trigger input enable output | ||||
Analog RGB monitor output |
SVGA (800 x 600 pixels) |
|||
RS-232C interface |
Measured data output and control input/output (Maximum baud rate: 115200 bps, selectable) |
|||
USB interface |
In conformity with USB Revision 2.0 HI-SPEED (USB 1.1 Full-SPEED compatible) |
|||
Ethernet interface |
1000BASE-T/1000 BASE-TX/10 BASE-T |
|||
Memory card |
SD card CA-SD4G (4GB), CA-SD1G (1GB) support |
|||
Rating |
Power voltage |
24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Current consumption. |
1 head connected 480mA max./ 2 heads connected 550mA max. |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 1,120 g |
|||
*1 1 or 2 units can be connected only with the same head model | ||||


Specifications
Model |
LS-C10AM |
|||
Type |
Camera cable |
|||
Applicable product |
LS-7000 series |
|||
Number included |
1 |
|||
Cable end |
Straight |
|||
Length |
10 m 32.8' |
|||
Note |
Up to two cables are connectable, provided that the total length is a maximum of 40 m 131.2'. |
|||
Weight |
Approx. 450 g |
|||



Specifications
Model |
IV2-G500MA |
|||
Type |
Standard model |
|||
Reference distance |
20 to 500 mm 0.79" to 19.69" |
|||
Field of view |
Installation distance of 20 mm 0.79": |
|||
Indicators |
2 (the same display details for both indicators) |
|||
Image receiving element |
Type |
1/3 inch monochrome CMOS |
||
Number of pixels |
752 (H) × 480 (V) |
|||
Focus adjustment |
Automatic*1 |
|||
Exposure time |
1/10 to 1/50000 |
|||
Lights |
Illumination |
White LED |
||
Lighting method |
Switchable between pulse lighting and DC lighting |
|||
Environmental resistance |
Enclosure rating |
IP67*2 |
||
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
|||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz; double amplitude 1.5 mm 0.06"; 2 hours in each of the X, Y, and Z directions*3 |
|||
Shock resistance |
500 m/s2 1640.4'/s2, 6 times in each of the 3 directions*3 |
|||
Material |
Main unit case: Zinc die-casting, Front cover: Acrylic (hard coat), Operation indicator cover: TPU |
|||
Weight |
Approx. 75 g |
|||
*1 The focus position can be automatically adjusted at the time of installation. This function is deactivated during operation. A different focus position can be registered for each program. | ||||

Specifications
Model |
IX-H2050 |
|||
Main unit / expansion unit |
Expansion unit |
|||
Display |
Min. display unit |
Z axis |
10 μm *1 |
|
X axis |
50 μm *1 |
|||
Display range |
Z axis |
±999.99 to ±999 mm 39.33" (with 4 selectable steps) *1 |
||
X axis |
±999.95 to ±999 mm 39.33" (with 4 selectable steps) *1 |
|||
Tools |
Scan mode |
Height, Step, Average height, Pin height, MAX/MIN, Height area, Monochrome area, Width, Step calculation, Thickness calculation, |
||
Line mode |
Height (Ave./Max./Min.), Step (Ave./Max./Min.), Edge position, Width/diameter, Step/width calculation, Thickness calculation, |
|||
Other functions |
Common |
Zero/offset, Operating threshold adjustment, 2-point calibration, Measurement direction, Position correction NG measurement, Zero/offset recording, Capture mode (HDR), |
||
Scan mode |
Measurement range, Measurement position (small/standard/large), Measurement mode, Measurement noise elimination, Imaging mode (high gain), |
|||
Line mode |
Average count, Laser position adjustment, Timing input, Head tilt correction (fixed only), Ambient light removal for measurement, |
|||
Input |
Input |
Switchable between non-voltage input and voltage input |
||
Number of inputs |
8 (IN1 to IN8) |
|||
Function |
IN1: External trigger ↑↓ / Timing input, IN2 to IN8: Enable by assigning optional functions |
|||
Output |
Output |
Open collector output; NPN/PNP switchable, N.O./N.C. switchable |
||
Number of inputs |
10 (OUT1 to OUT10) |
|||
Function |
Enable by assigning the optional functions |
|||
Analog voltage output |
Not available |
|||
Analog current output | ||||
Number of programs |
32 |
|||
Statistical information |
Scan mode: Measured value / Degree of similarity (Max., Min., Ave.), Processing time (Latest, Max., Min., Ave.), Count (Number of OKs / Number of NGs / Number of triggers)
|
|||
Detection history |
Saved history |
Scan mode |
50 (FTP/SFTP client function: Enabled/High-resolution mode: Enabled) |
|
Line mode |
400 (FTP/SFTP client function: Enabled/High-resolution mode: -) |
|||
Save conditions |
Selectable between NG only and All *5 |
|||
Image data transmission (FTP/SFTP client function) |
Destination |
FTP/SFTP server |
||
Method |
Selectable between bmp, jpeg, and txt |
|||
Conditions |
4 conditions |
|||
Ethernet |
Standard |
Not available *6 |
||
Connector | ||||
Interface compatibility |
CC-Link, DeviceNet®, EtherNet/IP™, EtherCAT®, RS-232C, BCD output, TCP/IP non-procedural communication *7 |
|||
Number of connectible units |
Main units: 1, Expansion units: 1, Communication units (DL): 1 |
|||
Ratings |
Power voltage |
Supplied from main unit |
||
Current consumption |
Max. 1.9 A or less (With main unit only: 0.8 A or less, With unit expansion: 1.9 A or less) (Excluding output load) *8 |
|||
Environmental resistance |
Ambient temperature |
0 to +50°C 32 to 122°F (No freezing) |
||
Relative humidity |
35 to 85% RH (No condensation) |
|||
Material |
Main unit case: PC / Power connector: PA, POM / Analog output connector: PA, POM / I/O connector: PA / |
|||
Weight |
Approx. 190 g |
|||
*1 For displaying on an IX Series control panel or PC software. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
MD-F3120C |
|||
Type |
30 W type wide area type main unit (controller + head) |
|||
Console (sold separately) |
MC-P1 |
|||
Marking method |
XYZ 3-Axis simultaneous scanning method |
|||
Marking laser |
Type |
Yb: fiber laser, Class 4 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
||
Wavelength |
1090 nm |
|||
Output |
30 W |
|||
Pulse frequency |
60 to 120 kHz |
|||
Guide laser/Working distance pointer |
Semiconductor laser, wavelength: 655 nm, output: 1.0 mW, Class 2 laser product (IEC 60825-1, JIS C6802, FDA [CDRH] Part 1040.10*1) |
|||
Marking area |
300 x 300 x 42 mm 11.81" x 11.81" x 1.65" |
|||
Standard working distance (±variable width) |
300 mm (±21 mm) 11.81" (±0.83") |
|||
Marking resolution |
5 µm 0.20 Mil |
|||
Scan speed |
8000 mm 314.96"/s max. |
|||
Character type |
Font |
KEYENCE original font (numerical value, alphabet, katakana, hiragana, and kanji)/user font/true type font |
||
Barcode |
CODE39/ITF/2of5/NW7 (CODABAR)/JAN/EAN/UPC/CODE128 |
|||
2D code |
QR code/micro QR code/DataMatrix (ECC200/GS1 DataMatrix) |
|||
GS1 DataBar |
GS1 DataBar Truncated/GS1 DataBar Truncated CC-A/GS1 DataBar Stacked/GS1 DataBar Stacked CC-A/GS1 DataBarLimited/GS1 DataBar Limited CC-A |
|||
Logo image |
Custom font, logo (CAD) data BMP/JPEG/PNG/TIF |
|||
Machinery operation |
Fixed point/straight line/dashed line/oval |
|||
Marking conditions |
Workpiece style |
Stationary marking/movement marking (constant speed/encoder) |
||
Character size (marking height/width) |
0.1 to 300 mm 0.003" to 11.81" |
|||
No. of registered programs |
2000 settings max. |
|||
No. of program blocks |
256 blocks |
|||
I/O (Input/output) |
Terminal block I/O, MIL connector I/O, contactor control I/O |
|||
Interface |
RS-232C, RS-422A, USB 2.0,*2 Ethernet (100BASE-TX/10BASE-T) |
|||
CF memory card slot |
Compact flash memory card*3 |
|||
Head installation direction |
All directions |
|||
Head cable length |
4m |
|||
Cooling method |
Controller: forced air cooling, head: natural air cooling |
|||
Rated voltage and power consumption |
100 to 120 VAC or 200 to 240 VAC ± 10 %, 50/60 Hz, Max. 550 VA |
|||
Environmental resistance |
Enclosure rating |
IP64 (Head) |
||
Pollution degree |
2 |
|||
Overvoltage category |
II |
|||
Ambient temperature for storage |
-10 to +60 °C 14 to 140 °F (No freezing) |
|||
Ambient temperature |
0 to +40 °C 32 to 104 °F |
|||
Ambient humidity for storage |
30 to 85 % RH (No condensation) |
|||
Relative humidity | ||||
Weight |
Controller: 27.0 kg |
|||
*1 The laser classification is implemented based on IEC 60825-1 in accordance with the requirements of FDA [CDRH] Laser Notice. | ||||


Specifications
Model |
GL-VM96HN |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
96 |
|||
Total length |
1920 mm 75.59" |
|||
Detection height |
1900 mm 74.80" |
|||
Protection height |
1945 mm 76.57" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
7.8 |
|
OFF→ON |
53.3 *3 |
|||
All blocked→ON |
64.3 *4 |
|||
With channel A or B |
ON→OFF |
25.1 |
||
OFF→ON |
82.7 *3 |
|||
All blocked→ON |
118.6 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
181 *5 |
||
Receiver |
196 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
61 *5 |
||
Receiver |
67 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1250 g 44.12 oz |
||
Receiver |
1260 g 44.47 oz |
|||
Total |
2510 g 88.60 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
OP-88901 |
|||
Female |
M12 8pin L-shape |
|||
Male |
Strand wire |
|||
Length |
5 m 16.4' |
|||
Material |
cable: Chemicalresistant PVC |
|||

Specifications
Model |
ER-GR08P |
|||
Type |
Environment-resistant all-metal shielded type Screw type M8 Cable PNP output |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
3 mm 0.12" ±10% *2 |
|||
Response frequency |
80 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
9 × 9 mm 0.35" × 0.35" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less (32 mA or less at 24 V, 47 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP68 (IEC60529), IP68G (JIS C 0920), IP69K (DIN40050) |
||
Ambient temperature |
-40 to +85°C -40°F to +185°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2 /Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface and case: SUS316L, Nut: SUS316L, Toothed lock washer: SUS316L |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 65 g 2.29 oz |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
GC-RP30 |
|||
Length |
30 m 98.4'*1 |
|||
Weight |
Approx.1950 g |
|||
*1 Power cable and External power cable are both free-cut. It is possible to cut the cable to a preferred length. | ||||

Specifications
Model |
LV-H300 |
|||
Type |
Area thrubeam , High performance |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Output |
3.0 mW (FDA), 1.0 mW (IEC) |
|||
Wavelength |
660 nm |
|||
Laser |
IEC 60825-1 |
Class II |
||
Detecting area |
30 mm 1.18" |
|||
Detecting distance |
2000 mm 78.74" |
|||
Pulse duration |
3.5 µs |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Transmitter: Glass Receiver: Polyarylate |
|||
Weight |
Approx. 100 g |
|||

Specifications
Model |
XC-T40B1 |
|||
Rated voltage |
125 VAC/DC |
|||
Rated current |
1 A/pin |
|||
Ambient operating temperature |
−40 to +80°C −40 to +176°F |
|||
Screw torque |
0.8 N·m (max.) |
|||
Applicable wire diameter |
AWG22 to 16 |
|||
Environmental resistance |
Insulation resistance |
500 VDC, 1000 MΩ or greater |
||
Withstand voltage |