Specifications
Model |
NR-X100W |
|||
Main unit buffer memory capacity |
50M data*1 |
|||
Expansion memory |
SD card (SD/SDHC)*2 |
|||
PC interface |
USB |
USB mini-B connector, USB 2.0 High-speed–compliant, Simultaneous USB connection from one PC to up to four units (switchable by ID switch) |
||
Ethernet |
RJ45 connector, 100Base-TX (AUTO MDI/MDIX supported) *3 |
|||
Wireless LAN |
Connection via NR-XW1 wireless LAN unit, IEEE 802.11b/g/n *3 |
|||
Network function |
FTP client function, FTP server function, SNTP client function |
|||
Display/operation |
Operation via NR-XCP30 control panel, or via WAVE LOGGER X with PC connection |
|||
Expansion remote unit connection |
Dedicated remote connection connector × 2 (Remote OUT A port, B port) |
|||
Number of connectable measurement units |
Master data collection unit group |
Max. 8 units*4 |
||
Total with remote units connected |
Max. 72 units*5 |
|||
Continuous acquisition speed |
Master data collection unit group |
Max. 100 kHz for all acquisition channels *6 |
||
Total with remote units connected |
Max. 500 kHz for all acquisition channels *6*7 |
|||
Inter-unit synchronization |
Between measurement units in the master data collection unit group |
±1 μs or less *8 |
||
Between the master data collection unit and each remote unit / environment-resistant measurement unit | ||||
Time axis accuracy |
±50 ppm (23°C ±3°C 73.4°F ±5.4°F); Same time used for all remote groups, SNTP server time synchronization possible |
|||
Synchronous trigger input (SYNC input) |
Performance specifications |
• Use as external trigger input (normal mode) or synchronous acquisition input (logging mode) |
||
Input specifications |
• For non-voltage input: ON voltage 1.0 V or lower (short circuit current: 1 mA typ.), OFF current 0.1 mA or lower |
|||
Control input |
Common specifications |
• Input type: Bidirectional voltage input |
||
Individual specifications |
• External trigger input (TRG IN): Edge input |
|||
Control output |
Common specifications |
• Output format: Photo MOS relay output |
||
Individual specifications |
• Trigger output (TRG OUT): N.O. output, one-shot output |
|||
Power supply |
• NR-XU1 AC adapter, or 9 to 36 VDC (including ripple) / Max. 72 W (when connected to DC terminal block; at 9 V: 8.0 A or less; at 24 V: 3.0 A or less; at 36 V: 2.0 A or less) |
|||
Power supply |
Power consumption |
8.4 W or less (excluding connected units) |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 490 g 17.30 oz (including approx. 10 g 0.35 oz for the OP-88512 (NR-X100W I/O terminal block)) |
|||
*1 Data is not backed up when the power is turned off. The available data buffer memory per NR-X100W and NR-XR01 group is limited to 25M. | ||||
All PLC Direct products come with a 1-year warranty. The warranty is issued by PLC Direct. Warranty coverage commences at the date of purchase. The warranty is for mechanical defects or failures not caused by human factors including but not limited to (a) incorrect installation, (b) operating the unit in sub-optimal conditions or in scenarios not recommended by the manufacturer, (c) poor unit maintenance, etc. The warranty does not cover programming or software related issues.
If the product is eligible for PLC Direct’s warranty coverage and the customer encounters an issue with the product, we will request the item is shipped to us for diagnosis and examination. Regardless of the cause of product issues, the customer will bear responsibility for the cost of shipping the unit to PLC Direct for evaluation. Where the unit was damaged by human factors, we will offer a repair or replace quote; in cases where damage was caused by human factors, the customer is responsible for the cost of shipping the repaired/replaced unit from PLC Direct to the customer. Where the unit was not damaged by human factors but is covered by PLC Direct’s warranty, we will repair or replace the unit at our cost (or, in rare cases, refund you your purchase); in such cases, PLC Direct will bear the cost of shipping the repaired or replaced product back to the customer. It is up to PLC Direct’s discretion whether to repair, replace, or refund the customer in such cases. Diagnoses can take time to complete based on technician availability and the complexity of diagnosis.
In no event shall PLC Direct be liable for any damages except actual damages up to, but not exceeding, the amount paid to us for the product, including we shall not be liable for any consequential or indirect damages or lost profits whether or not advised of same.
PLC Direct offers free shipping worldwide. Product ship from a various warehouses worldwide based on the customer's and the product's location. The estimated delivery date on the product page is PLC Direct's best estimated assuming a US-based shipping destination.
Regardless of where the product is shipping from, PLC Direct covers all duties for US-based shipping destinations. For non-US-based shipping destinations, customers are responsible for duties as appropriate.
PLC Direct's focus is on balancing price with lead time. Some but not all products can be expedited. If you have questions about delivery ETAs, please contact our team.


"Fast service for obsolete parts"
Increasingly PLC/ HMI control platforms are becoming obsolete and parts are no longer supported, however PLC Direct had the HMI we needed and fast shipping for our system to get back online!
Buyer at GE Health

"Helping us move projects forward"
With supply chain issues increasingly affecting our business, PLC Direct has been there for us to supply the PLC products we need, when we need it. If they don't have it readily available, they find it and provide it quickly and reliably. This has helped us move forward with several projects that would have otherwise taken us many, many months to complete.
Buyer at E-Merge Systems – A Rockwell Integrator