Specifications
Model |
AH-809 |
|||
Type |
Sensor head for high temperatures |
|||
Amplifier unit |
AS-425K |
|||
Shape |
Cylindrical, diameter: 9.4 |
|||
Measuring range |
0.5 to 1.0 mm0.02" to 0.039" |
|||
Analog output voltage |
Output voltage |
0.5 to 1.0V |
||
Straight line range |
― |
|||
Impedance |
100 Ω |
|||
Resolution |
0.4% of F.S.*1 |
|||
Linearity |
±4% of F.S. |
|||
Response |
3.3kHz (-3dB) |
|||
Temperature |
Sensor head |
0.14% of F.S./°C*2 |
||
Temperature characteristics |
Amplifier unit |
0.1% of F.S./°C*2 |
||
Rating |
Power voltage |
115/230 VAC ±15 %, 50/60 Hz |
||
Power consumption |
6VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
Heat-resistant type*3 |
|
Operating ambient temperature |
-10 to 200°C 14 to 392°F, No condensation |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Sensor head |
Approx 55g |
||
Weight (including cord) |
Amplifier unit |
Approx 180 g (including the cable) |
||
*1 The AS-425K full scale is 0.5 to 1.0 mm (0.5 mm) 0.0197" to 0.0394"(0.0197"). The temperature characteristics refer to data when the temperature is in the range of +23 to +200°C +73.4 to +392°F. | ||||

Specifications
Model |
OP-88088 |
|||
Type |
Ethernet extension cable (RJ45) |
|||
Length |
10 m 32.81' |
|||
Weight |
Approx. 660 g 23.28 oz |
|||




Specifications
Model |
OP-51429 |
|||
Overview |
Reflective tape used with polarized retro-reflective laser sensor (200x20mm). |
|||
Applicable product |
LV-H62, LV-H64, LV-H65 |
|||
Material |
Polycarbonate, Acrylic adhesive |
|||

Specifications
Model |
EX-416V*1 |
|||
Type |
Sensor head |
|||
Amplifier unit |
NPN: EX-V05 |
|||
Shape |
ø14.5 x 20 mm |
|||
Measuring range |
0 to 5 mm 0 to 0.20" |
|||
Display range |
-19,999 to +19,999 |
|||
Linearity |
±0.3% of F.S. |
|||
Resolution (No. of averaging |
1 μm |
|||
Sampling rate |
40,000 samplings max./sec. *2 |
|||
Display speed |
20 times/sec. |
|||
Display power |
7-segment 2-color LED |
|||
Over-range alarm |
±FFFF is displayed. |
|||
Control input |
NPN open-collector or non-voltage contact (Timing input, Reset input, Auto-zero input, Comparator output disable input, Synchronous input, External setting input)/PNP: Applied voltage; 10 to 30 V |
|||
Control output |
Setting method |
Upper/lower 2-level setting x 4 patterns (selectable) |
||
Signal |
NPN open-collector (HIGH, GO and LOW): 100 mA max. (40 V max.) |
|||
Response time |
0.075 ms (at maximum speed) |
|||
OFF-delay time |
60 ms |
|||
Strobe output |
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.O.) |
|||
Alarm output |
NPN: 100 mA max. (40 V max.)/PNP: 100 mA max. (30 V max.), Residual voltage: 1 V max. (N.C.) |
|||
Analog output voltage |
Output voltage |
±5V |
||
Impedance |
100 Ω |
|||
Response time |
0.075 ms (at maximum speed) |
|||
Temperature characteristics |
0.07% of F.S./°C *3 |
|||
Major functions |
FLL, digital filter, auto zero, offset, calculation, measurement mode (15 types), judgment value memory (4 sets), decimal point shift, display digit changing, display of various errors, etc. |
|||
Rating |
Power voltage |
24 VDC ±10%, Ripple (P-P): 10% max. |
||
Current consumption |
240 mA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +60 °C 14 to 140 °F, No freezing |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Approx. 75 g (including 3 m 9.8' cable) |
|||
*1 The above data was obtained using an iron target (S45C, SS400, t=1 mm 0.04"). When measuring aluminum, copper, or stainless steel targets, refer to the linear characteristics for these materials. | ||||

Specifications
Model |
FL-CP20 |
|||
Total length (at 25 °C) |
203 |
|||
Measurement range (dead zone excluded) |
157 (137)*1 |
|||
Weight |
Approx. 160 g |
|||
*1 Values for water. For oil | ||||

Specifications
Model |
EM-030B*1 |
|||
Type |
Shielded |
|||
Shape |
3 mm 0.12" dia Cylindrical. |
|||
Detecting distance |
0.6 mm 0.02" ±15% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
5 x 5 mm 0.20" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Control output |
NPN: 200 mA (40 V) max., Residual voltage: 1 V max. |
|||
Housing |
Stainless steel |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*2 |
||
Current consumption |
12 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 36 g (including nuts and 2-m 6.6' cable) |
|||
*1 The alternative-frequency type of EM-030 | ||||

Specifications
Model |
KV-N14AT |
|||
General specifications |
Power voltage |
100 to 240 VAC (+10%/-15%) |
||
Operating ambient temperature |
0 to 55°C 32 to 131°F (no freezing)*1*2 |
|||
Operating ambient humidity |
5 to 95%RH (no condensation)*1 |
|||
Operating environment |
As little dust and corrosive gas as possible |
|||
Noise immunity |
1500 V peak-to-peak or more, pulse duration 1 μs, 50 ns (based on noise simulator), IEC standard compliant (IEC61000-4-2/3/4/6) |
|||
Withstand voltage |
1500 VAC for 1 minute, between power supply terminal and I/O terminals and between all external terminals and case |
|||
Insulation resistance |
50 MΩ or more (500 VDC megger used to perform measurements between power terminal and input terminals, and between all external terminals and case) |
|||
Output power supply voltage |
24 VDC (±10%; output capacity : 0.6 A) |
|||
Storage temperature |
−25 to +75°C −13 to +167°F |
|||
Vibration resistance |
Intermittent vibration |
Frequency: 5 to 9 Hz |
Amplitude: 3.5 mm 0.14"*3*4 |
|
Frequency: 9 to 150 Hz |
Acceleration: 9.8 m/s2 32.2'/s2*3*4 |
|||
Continuous vibration |
Frequency: 5 to 9 Hz |
Amplitude: 1.75 mm 0.07"*3*4 |
||
Frequency: 9 to 150 Hz |
Acceleration: 4.9 m/s2 16.1'/s2*3*4 |
|||
Shock resistance |
Acceleration: 150 m/s2 492.1'/s2, application time: 11 ms, three times in each of the X, Y, and Z directions |
|||
Operating altitude |
2000 m 6561.7' or less |
|||
Overvoltage category |
AC: II, DC: I |
|||
Pollution degree |
2 |
|||
Performance specifications |
Calculation control method |
Program storage method |
||
I/O control method |
Refresh method |
|||
Program language |
Expanded ladder, KV Script, mnemonic |
|||
Number of instructions |
Basic instruction: 81 types and 182 instructions, Application instruction: 39 types and 56 instructions, Calculation instruction: 123 types and 311 instructions, Expansion instruction: 92 types and 141 instructions, Total: 335 types and 690 instructions |
|||
Instruction execution speed |
Basic instruction: 50 ns minimum, Application instruction: 170 ns minimum |
|||
Program capacity |
8k steps |
|||
Maximum number of attachable I/O units |
3 |
|||
Maximum number of I/O points |
128 (excluding the base unit I/O) |
|||
Input relay/Output relay/Internal auxiliary relay |
R |
Total of 9600 points 1 bit (R000 to R59915) |
||
Link relay |
B |
8192 points 1 bit (B0 to B1FFF) |
||
Internal auxiliary relay |
MR |
9600 points 1 bit (MR000 to MR59915) |
||
Latch relay |
LR |
3200 points 1 bit (LR000 to LR19915) |
||
Control relay |
CR |
1440 points 1 bit (CR000 to CR8915) |
||
Timer |
T |
512 points 32 bit (T0 to T511) |
||
Counter |
C |
256 points 32 bit (C0 to C255) |
||
Data memory |
DM |
32768 points 16 bit (DM0 to DM32767) |
||
Link register |
W |
16384 points 16 bit (W0 to W3FFF) |
||
Temporary memory |
TM |
512 points 16 bit (TM0 to TM511) |
||
High-speed counter |
CTH |
2 points (CTH0 to CTH1), 32-bit automatic reset counter*5 (Input response: 100 kHz per single phase, 50 kHz per phase difference)*6 |
||
High-speed counter comparator |
CTC |
4 points (CTC0 to CTC3), 32 bits, two points per high-speed counter |
||
Index register |
Z |
12 points 32 bit (Z01 to Z12) |
||
Control memory |
CM |
9000 points 16 bit (CM0 to CM8999) |
||
Positioning pulse output |
2 axes, Maximum output frequency: 100 kHz |
|||
Base unit I/O |
Input: 8 points, output: 6 points, Input common: 1 point, Output common: 1 point |
|||
Number of comments and labels that can be stored in the main unit |
Device comment |
10000 |
||
Label |
14000 |
|||
Power off hold function |
Program memory |
Flash ROM can be rewritten 10000 times |
||
Device |
Nonvolatile RAM*7 |
|||
Self-diagnosis function |
CPU error, RAM error, and other problems |
|||
Input specifications |
Relay number |
General input: R000 to R003 (4 points), High-speed A-phase and B-phase input: R004 to R007 (2 channels, 4 points in total) |
||
Input mode |
24 VDC input (open collector) |
|||
Maximum input voltage |
26.4 VDC |
|||
Rated input voltage |
24 VDC (General input: 5.3 mA, High-speed A-phase and B-phase input: 6.5 mA*8) |
|||
Minimum ON voltage |
19 VDC |
|||
Maximum OFF current |
1.5 mA |
|||
Common method |
General input: All points/1 common (1 terminal), High-speed A-phase and B-phase input: Shared common for all points (shared with general input) |
|||
Circuit delay time |
General input: |
|||
Input time constant |
Normal: 10 ms, When the HSP instruction is used: 10 μs |
|||
Input time constant setting 10 μs: Digital filter 1.6 to 2 μs | ||||
Response frequency |
(High-speed A-phase and B-phase input) Single phase: 100 kHz, phase difference: 50 kHz, 24 V ±10%, Duty 50% |
|||
Output specifications |
Relay number |
General output: R504 to R505 (2 points), High-speed output: R500 to R503 (4 points) |
||
Output mode |
MOSFET *10 |
|||
Rated load |
30 VDC, 0.5 A |
|||
Maximum OFF voltage |
30 VDC |
|||
Leakage current at OFF |
100 μA or less |
|||
Residual voltage at ON |
0.8 VDC or less (with 0.5 A output), 0.6 VDC or less (with 0.3 A output) |
|||
Common method |
8 to 10 points/1 common |
|||
ON/OFF response time |
General output: |
|||
Overcurrent protection |
Protection provided for each common*11 |
|||
Output frequency |
High-speed output: 100 kHz (7 to 100 mA load) |
|||
Built-in serial port |
Interface |
Communication standard |
RS-232C |
|
Connection |
Modular connector |
|||
Transmission specifications RS-232C |
Baud rate |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps |
||
Transmission method |
Full duplex |
|||
Data format |
Start bit |
1 bit |
||
Data bits |
7 bits, 8 bits |
|||
Stop bits |
1 bit, 2 bits |
|||
Error detection |
Parity |
Even, odd, none |
||
Transmission distance |
15 m 49.2' |
|||
Number of transmission units |
1 |
|||
Indication |
SD (green), RD (red) |
|||
Internal current consumption |
75 VA (* The VA values are calculated with a power factor of 30%.) |
|||
Weight |
Approx. 420 g |
|||
*1 The range guaranteed as a system (excluding items specially noted for the units and cassettes). | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
ER-GL08P |
|||
Type |
General-purpose all-metal shielded type Screw type M8 Cable PNP output Long-Range |
|||
Power supply cable length |
2 m 6.6' *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
― |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
3 mm 0.12" ±10% *2 |
|||
Response frequency |
80 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
9 × 9 mm 0.35" × 0.35" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs |
|||
Control output |
Residual voltage |
PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
750 mW or less |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), IP67G (JIS C 0920) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *7 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), |
|||
Material |
Detecting surface: SUS303, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 65 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types and no longer than 20 m 65.6' with IO-Link connections. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
CV-L3 |
|||
Focal point |
3.5 mm 0.14" |
|||
F-stop range (aperture) |
F1.6 to CLOSE |
|||
Minimum WD |
0.1 m 0.3' |
|||
Mount |
C-mount |
|||
Filter size |
43.0 mm 1.69" P0.75 |
|||
Compatible image sensor size |
1/2" |
|||
TV distortion |
-10.0 % (-5.0 %)*1 |
|||
Resolving power |
100 cycles/mm at center, 40 cycles/mm on periphery |
|||
Ambient temperature/humidity range |
0 to +50°C 32 to 122°F, 80% RH or less (No condensation) |
|||
Polarizing filter |
OP-87894 |
|||
Protective filter |
CA-LF43 |
|||
Weight |
Approx. 90 g |
|||
*1 Indicates specification for compatible image sensor size. Value in parenthesis applies to 1/3" image sensor size. | ||||

Specifications
Model |
SV3-500L2 |
|||
General specifications |
Capacity |
5.0 kW |
||
Input power supply |
Voltage/frequency |
Main circuit |
3-phase (or single-phase*1) 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2 |
|
Control circuit |
Single-phase 200 to 240 VAC (-15%/+10%), 50/60 Hz, 270 to 324 VDC*2 |
|||
Allowable frequency fluctuation |
Main circuit/control circuit |
±5% max. |
||
Overvoltage category |
III |
|||
Control mode |
Three-phase full-wave rectification, IGBT, PWM control, Sine wave current drive system |
|||
Feedback |
Serial encoder (absolute) communication, Fully closed control serial communication, Analog feedback |
|||
Operating environment |
Operating atmosphere |
Enclosure rating |
IP20:SV3-005L2/010L2/020L2/040L2/075L2/100L2/150L2 |
|
Pollution degree |
2 (in an IP54 or higher control panel) However, the product must be used in the following environments: |
|||
Operating ambient temperature |
-5 to +60°C 23 to 140°F (No freezing) (reduced ratings at +55°C 131°F or higher) |
|||
Storage ambient temperature |
-20 to +85°C -4 to +185°F (No freezing) |
|||
Operating/storage ambient temperature |
95% RH or less (No condensation) |
|||
Altitude |
No more than 2,000 m 6,561.7' above sea level (reduced ratings at 1,000 m 3,280.8' or higher) |
|||
Vibration resistance |
4.9 m/s2 16.1 ft/s2 (Compliant with JIS C60068-2-6) |
|||
Impact resistance |
19.6 m/s2 64.3 ft/s2 (Compliant with JIS C60068-2-27) |
|||
Other |
No static noise, strong electric or magnetic fields, or radiation |
|||
Applied standard |
UL/CSA standards |
UL 61800-5-1, CSA 22.2 No. 274 |
||
CE marking |
Machinery Directive |
EN 61800-5-1, EN 61800-5-2, EN ISO 13849-1:2015 Cat. 3 PLe, EN IEC 62061 Maximum SIL3 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part 15 B, ICES-003. Class A |
|||
Structure |
Type |
Base mount installation |
||
Safety function |
STO function (STO/EN 61800-5-2) |
|||
Safety function |
Safety parameters |
SIL 3 / EN 61508, Maximum SIL 3 / EN IEC 62061, PLe (Category 3) / EN ISO 13849-1:2015 |
||
Response time |
4 ms(max) |
|||
Input |
STO1, STO2: Power module base block signals |
|||
Output |
EDM: Built-in safety circuit status monitoring (fixed output) |
|||
Protection function |
Overcurrent, overvoltage, undervoltage, overload, regenerative error, etc. |
|||
Min. insulation resistance |
500 VDC 1 MΩ or more with insulation resistance meter |
|||
Insulation withstand voltage |
1,500 VAC or more (between primary side and ground) |
|||
Weight |
Approx. 4.4 kg 9.70 lb |
|||
Power supply/current capacity and power loss |
Main circuit power supply |
Three-phase 200 V/DC 270 V |
||
Max. applicable motor capacity |
5.0 kW |
|||
Power supply capacity for 1 amplifier |
7.5 kVA |
|||
Output current |
Continuous |
32.9 Arms |
||
Max. |
84 Arms |
|||
Main circuit power loss |
Three-phase 200 V: 226.6 W |
|||
Regenerative resistor power loss |
Three-phase 200 V: 36 W |
|||
Control circuit power loss |
19 W |
|||
Total power loss |
Three-phase 200 V: 245.6 W |
|||
Rated input current |
Main circuit |
Three-phase 200 V: 25 Arms |
||
Control circuit |
0.3 Arms |
|||
Rush current |
Main circuit |
Three-phase 200 V: 68 A *3 |
||
Control circuit |
34 A *3 |
|||
Performance specifications |
Performance |
Speed control range |
1:5000 (Under conditions where load torque is equal to or less than rated torque) |
|
Speed fluctuation rate |
At load fluctuation |
0 to 100% load variation: ±0.01% or less (at rated rotation speed) |
||
At main circuit voltage change |
Rated voltage ±10%: 0% (at rated rotation speed) |
|||
At ambient temperature change |
Ambient temperature 0 to +50°C 32 to 122°F: |
|||
Torque control accuracy (reproducibility) |
±1% |
|||
Velocity frequency response |
3.1 kHz |
|||
Dynamic brake |
Operates at main circuit power off, servo alarm, servo off, limit switch detection (LSP/LSN), and forced stop detection (FSTOP) |
|||
Regenerative resistor |
Built-in regenerative resistor: Disabled at 50 to 400 W |
|||
Display Function |
Panel function |
7-segment LED |
||
Communication status indicator LED |
EtherCAT® communication: L/A × 2 |
|||
Servo functions |
Tuning |
Auto-tuning, notch filter, vibration suppression, damping control, model tracking, friction compensation, load inertia moment ratio variation compensation, deviation reduction, low-frequency vibration suppression, etc. |
||
Monitor |
Lifespan prediction, vibration, load factor, power consumption, temperature, etc. |
|||
I/O specifications |
Sequence input signal |
Number of inputs |
7 (3 high-speed inputs, 4 general-purpose inputs) |
|
Max. input voltage |
28.8 VDC |
|||
Rated input voltage |
24 VDC |
|||
Min. ON voltage |
19 VDC |
|||
Max. OFF current/voltage |
High-speed input: 0.1 mA, General-purpose input: 0.3 mA |
|||
Common point mode |
7 points/1 common (1 terminal) (bidirectional) |
|||
Input time constant |
250 μs, 500 μs, 1 ms, 2.5 ms, 5 ms, 10 ms |
|||
Input current |
High-speed input: 4.4 mA, General-purpose input: 4.5 mA |
|||
Input impedance |
Approx. 5.1 kΩ |
|||
Assignable input signals |
All signal assignment, Logic settable forced stop (FSTOP), Probe 1 latch input (PROBE1), Probe 2 latch input (PROBE2), Home switch input (HOME), Forward side limit switch (LSP), Reverse side limit switch (LSN), Forward side torque limit selection (PTL), Reverse side torque limit selection (NTL) |
|||
Sequence output signal |
Number of outputs |
4 |
||
Output mode |
Transistor NPN output |
|||
Rated load |
30 VDC/50 mA |
|||
Leakage current when OFF |
0.5 mA |
|||
Residual voltage when ON |
1.5 VDC or less |
|||
Common point mode |
Independent common |
|||
Assignable output signals |
Assignment of each signal except ALARM signal, Logic setting available alarm (ALARM), In-position (INPOS), Velocity matching (VCMP), Zero speed detection (ZSP), Ready to run (RDY), Torque limiting (TLM), Velocity limiting (VLM), Electromagnetic brake timing (BRAKE), Warning (WARN), Near positioning (NEAR) |
|||
Analog Feedback Input signal monitor |
Max. input voltage |
±12 V |
||
Accuracy |
±1% of F.S. |
|||
Resolution |
±12 bits |
|||
Input impedance |
30 kΩ |
|||
Encoder division pulse output signal |
Output mode |
A-phase (A+/A-), B-phase B (B+/B-), Z-phase (Z+/Z-): Differential line driver output |
||
Line driver |
SN75ALS174 (T.I.) equivalent |
|||
Output frequency |
1.6 Mpps (at 2-phase quadruplication, equivalent to 6.4 MHz)*6 |
|||
Analog monitor output |
No. of channels |
2 ch |
||
Output range |
±10 V (Linearity effective range: ±8 V) |
|||
Resolution |
16 bits |
|||
Conversion precision |
±20 mV (typ.) |
|||
Max. allowable load current |
±10 mA |
|||
Conversion speed |
1.2 ms (typ.) |
|||
Communication specifications |
EtherCAT® communication |
Applicable communication standards |
IEC 61158 Type12, |
|
Physical layer |
100 BASE-TX(IEEE802.3) |
|||
Cable |
Category 5 STP, 2 pair |
|||
Mailbox |
Emergency messages, SDO requests, SDO responses |
|||
Distributed clocks |
Free-run, DC mode (switchable), Supported DC cycles (62.5 μs to 4 ms, in 62.5 μs increments) |
|||
Max. distance between stations |
50 m 164.0' |
|||
USB communication |
Connected device |
PC |
||
Communication standard |
USB 2.0–compliant |
|||
Function |
Status display, Parameter settings, Tuning, etc. |
|||
*1 Single-phase input can only be used with the SV3-005L2, SV3-010L2, SV3-020L2, SV3-040L2, and SV3-075L2. | ||||

Specifications
Model |
SV-D5D |
|||
Type |
Electromagnetic brake cable |
|||
Length |
5 m 16.4' |
|||
Note |
Applicable servo amplifier capacity: 1 k to 5 kW |
|||

Specifications
Model |
ER-30PC *1 |
|||
Type |
Ultra-long distance shielded type Screw type M18 Connector (M12 4-pin) PNP output |
|||
Power supply cable length |
― *2 |
|||
No. of control outputs |
2 |
|||
Output mode |
Output 1 |
N.O. |
||
Output 2 |
N.C. |
|||
Button |
Available |
|||
Button |
Function |
Distance switching, Through-Metal |
||
Detecting distance |
With default settings (Mode 1) |
26 mm 1.02" ±10% *3 |
||
With distance switching (Mode 2) |
20 mm 0.79" ±10% *3 |
|||
Response frequency |
With default settings (Mode 1) |
15 Hz *4 *5 |
||
With distance switching (Mode 2) |
30 Hz *4 *5 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *6 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
78 × 78 mm 3.07" × 3.07" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) |
|||
Control output |
Open-collector, 30 VDC or less |
|||
Control output |
Residual voltage |
PNP output: 2.1 V or less (Output current: 10 mA or less) / |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
PNP output: 1140 mW or less (48 mA or less at 24 V, 72 mA or less at 16 V) *8 |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) *9 |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
1000 m/s2 3280.8 ft/s2 (100 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Detecting surface: LCP, Mounting screw: SUS303 (M30: SUS304), Case resin: PBT, Button: PBT, Nut: SUS304, Toothed lock washer: SUS304 |
|||
Accessories |
Nut ×2, Toothed lock washer ×1 |
|||
Weight |
Approx. 140 g |
|||
*1 Supports IO-Link specification v1.1/COM2 (38.4 kbps). | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.