Specifications
Model |
CZ-V21 |
|||
Output |
NPN output |
|||
Main unit/expansion unit |
Main unit |
|||
Response time |
8 ms (SUPER) /4 ms (TURBO) /1 ms (FINE) /200 µs (HIGH SPEED) |
|||
Control output |
NPN open-collector x 4 channels, 40 VDC max., Up to 100 mA for one output, Up to 200 mA in total of 4 outputs, Residual voltage: 1.0 V max.*1 |
|||
Protection circuit |
Reverse-polarity protection, overcurrent protection, surge absorber |
|||
External calibration input |
No-voltage input, input time: 20 ms or more |
|||
External shift input | ||||
Timer function |
Timer OFF/OFF-delay/ON-delay/One-shot, Timer time: 1 to 1000 ms adjustable (for each bank respectively) |
|||
Unit expansion |
Up to 3 units (4 units total including the main unit)*2 |
|||
Rating |
Power voltage |
24 VDC, Ripple (P-P) 10 % or less |
||
Power consumption |
Normal mode: 1.5 W (62.5 mA or less), Eco-mode: 1 W (42.0 mA or less) |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*3 |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing, cover: Polycarbonate |
|||
Weight |
Approx. 110 g |
|||
*1 20 mA max. when several units are connected. | ||||

Specifications
Model |
OP-51455 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V23F, SL-V12H, SL-V06L, SL-C12H |
|||
Number included |
1 pcs. |
|||
Length |
230.3 mm 9.07" |
|||
Material |
Translucent plastic: Polycarbonate (t=Approx. 1.6mm), Black plastic: ABS |
|||
Note |
To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42 |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
PR-F51C3PL*1 |
|||
Type |
Thrubeam |
|||
Output |
PNP |
|||
Shape |
Flat |
|||
Cable connection |
M8 connector (3 pin) |
|||
Detection distance |
0.6 m |
|||
Number of control outputs |
1 output |
|||
Output operation |
Output 1 |
- |
||
Output 2 |
Light-ON |
|||
Response time |
Output 1 |
- |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
- |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
- |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including 10 % ripple (P-P) |
||
Current consumption |
Transmitter: 11 mA, Receiver: 16 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 20 g |
|||
*1 The M8 connector (3 pin) type has 1 control output. If "D" is at the end of the part number, the sensor is equipped with a Dark-ON output. If "L" is at the end of the part number, the sensor is equipped with a Light-ON output. Example: The PR-M51C3PL has a Light-ON output. | ||||

Specifications
Model |
FU-66Z*1 |
|||
Size |
M4 |
|||
Detection arrangement |
Parallel |
|||
Fibre unit length |
2 m78.74" free-cut |
|||
Fibre unit diameter |
ø1.3×2 |
|||
Shape |
Straight |
|||
Minimum bend radius |
R2 mm0.079" Tough-Flex |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *2 |
|||
Environmental resistance |
Ambient temperature |
-40 to +50 °C -40 to 122 °F |
||
Weight |
Approx. 10 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
GL-VM08HN |
|||
Beam axis spacing/Lens diameter |
20 mm 0.79": ø5 ø0.197" |
|||
Number of beam axes |
8 |
|||
Total length |
160 mm 6.30" |
|||
Detection height |
140 mm 5.51" |
|||
Protection height |
185 mm 7.28" |
|||
Minimum detectable object size |
ø25 mm ø0.98" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.1 |
|
OFF→ON |
45.7 *3 |
|||
All blocked→ON |
51.2 *4 |
|||
With channel A or B |
ON→OFF |
10.3 |
||
OFF→ON |
57.1 *3 |
|||
All blocked→ON |
70.8 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
56 *5 |
||
Receiver |
68 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
49 *5 |
||
Receiver |
56 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
120 g 4.23 oz |
||
Receiver | ||||
Total |
240 g 8.47 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
IV4-G600MA |
|||
Type |
Wide field of view model |
|||
Installed distance |
From 50 mm 1.97" |
|||
Field of view |
Installation distance 50 mm 1.97": 51 (H) × 38 (V) mm to |
|||
Image receiving element |
Type |
1/2.9 inch monochrome CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Focus adjustment |
Auto *1 |
|||
Exposure time |
12 μs to 9 ms *2 *3 |
|||
Lights |
Illumination |
Infrared LED |
||
Lighting method |
Pulse lighting |
|||
Indicators |
2 indicators (both displaying same content) |
|||
Power supply |
Average power consumption |
2.5 W (without AI imaging illumination unit installed) |
||
Environmental resistance |
Enclosure rating |
IP67 *4 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *5 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions |
|||
Material |
Main unit case: Zinc die-casting. Front cover: Acrylic. Operation indicator cover: TPU *6 |
|||
Weight |
Approx. 75 g 2.65 oz (no AI imaging illumination unit) |
|||
*1 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program. | ||||

Specifications
Model |
EM-080P |
|||
Type |
Shielded |
|||
Shape |
8 mm 0.31" dia Cylindrical. |
|||
Detecting distance |
2.0 mm 0.08" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for non-ferrous metals) |
|||
Standard target |
10 x 10 mm 0.39" x 0.39" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
1.2 kHz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at +23°C 73.4°F, within -10 to +70°C 14 to 158°F |
|||
Display indicator |
Red LED |
|||
Output |
PNP |
|||
Control output |
PNP: 200 mA (30 V) max., Residual voltage: 1 V max. |
|||
Housing |
Stainless steel |
|||
Rating |
Power voltage |
10.8 to 30 VDC, Ripple (P-P) 10 % or less*1 |
||
Current consumption |
20 mA or less |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Weight |
Approx. 42 g (including nuts and 2-m 6.6' cable) |
|||
*1 Make sure that the power voltage stays within 10.8 V to 30 V even if it is affected by ripple effects. | ||||



Specifications
Model |
AP-C31K |
|||
Type |
Negative pressure, NPN |
|||
Rated pressure |
0 to -29.9 inchHg |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 0.43" (11 mm)) Display cycle: 10 times/s |
|||
Operation indicator |
Red LED x 2 (corresponding to control output 1 and 2) |
|||
Display resolution |
Normal mode: 0.1 inchHg, Focus mode: 0.01 inchHg |
|||
Power consumption |
Normal |
12 V: 720 mW (60 mA) or less, 24 V: 960 mW (40 mA) or less |
||
Eco mode |
12 V: 480 mW (40 mA) or less, 24 V: 720 mW (30 mA) or less |
|||
Display temperature characteristic |
±1 % of F.S. max. |
|||
Hysteresis |
Variable (Standard: 0.5 % of F.S.)*1 |
|||
Response time (Chattering prevention function) |
2.5, 5, 100, or 500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V with load impedance of 1 kΩ max. (or zero-shift input selectable) |
||
Zero-shift input |
Input time: 2 ms or more. (or analog output selectable) |
|||
Control output |
NPN open collector 100 mA max. (at 40 V or below) with max. residual voltage of 1 V, 2 outputs (NO or NC selectable) |
|||
Pressure port |
NPT 1/8 180 ° rotation |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Environmental resistance |
Pressure resistance |
500 kPa |
||
Ambient temperature |
0 to 50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polysulfone, Rear housing: PBT, Front seat: Polycarbonate, Pressure port: Zinc die-casting |
|||
Accessories |
Power supply cord (6.6' 2-m with connector) |
|||
Weight |
Approx. 30 g (without cable) /Approx. 85 g (with 6.6' 2-m cable) |
|||
*1 A standard of 0.2 % of FS applies while in focus mode. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
AS-440-05U |
|||
Type |
General-use amplifier unit |
|||
Sensor head |
AH-416 |
|||
Shape |
Cylindrical and threaded, diameter: 14.5 |
|||
Measuring range |
0 to 5 mm 0.20" |
|||
Analog output voltage |
Output voltage |
0 to 5 V |
||
Impedance |
100 Ω |
|||
Resolution |
0.1% of F.S. |
|||
Linearity |
±1% of F.S. |
|||
Response |
3.3 kHz (-3 dB) |
|||
Temperature |
Sensor head |
0.03% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
0.05% of F.S./°C*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
IP67 |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F, No freezing |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Sensor head |
Approx 75 g |
||
Weight (including cord) |
Amplifier unit |
Approx 320g |
||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||

Specifications
Model |
PR-MB30C3PL*1 |
|||
Type |
Reflective (Background suppression) |
|||
Output |
PNP |
|||
Shape |
Mini-slim |
|||
Cable connection |
M8 connector (3 pin) |
|||
Detection distance |
1 to 30 mm 0.039" to 1.181" |
|||
Number of control outputs |
1 output |
|||
Output operation |
Output 1 |
- |
||
Output 2 |
Light-ON |
|||
Response time |
Output 1 |
- |
||
Output 2 |
ON→OFF: 2.7 ms, OFF→ON: 0.5 ms |
|||
Sensitivity adjustment |
None |
|||
Spot diameter |
Approx. ø5.5 mm (at 30 mm) |
|||
Light source |
4 element, point light source, red LED (650 nm) |
|||
Mutual interference prevention function |
4 sensors |
|||
Indicator lamp |
Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green) |
|||
Control output |
30 VDC or lower, 50 mA or lower |
|||
Protection circuit |
Power supply reverse connection protection, output overcurrent protection, |
|||
Rating |
Power voltage |
10 to 30 VDC, including 10 % ripple (P-P) |
||
Current consumption |
19 mA |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529), 4X, 6P, 13 (NEMA250) |
||
Insulation resistance |
20 MΩ or higher (500 VDC) |
|||
Ambient light |
Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower |
|||
Ambient temperature |
-25 to +55 °C -13 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +75 °C -13 to 167 °F |
|||
Withstand voltage |
1,000 VAC, 50/60 Hz, 1 min |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: SUS316L, indicator cover/lens cover: polysulfone, |
|||
Accessories |
Instruction Manual |
|||
Weight |
Approx. 13 g |
|||
*1 The M8 connector (3 pin) type has 1 control output. If "D" is at the end of the part number, the sensor is equipped with a Dark-ON output. If "L" is at the end of the part number, the sensor is equipped with a Light-ON output. Example: The PR-M51C3PL has a Light-ON output. | ||||

Specifications
Model |
CZ-H35S |
|||
Type |
Luster cancel |
|||
Detecting area |
28 to 52 mm 1.10" to 2.05" |
|||
Smallest spot diameter |
4.5 mm 0.18"dia. at reference |
|||
Light source |
Red LED (665 nm)/Green LED (520 nm)/Blue LED (465 nm) |
|||
Minimum bend radius of fi ber |
25 mm 0.98" |
|||
Environmental resistance |
Enclosure rating |
IP40 |
||
Ambient light |
Incandescent lamp: 10,000 lux max., Sunlight: 20,000 lux max. |
|||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing:Triacetate, Polyarylate (Metal section: TYPE 304 stainless steel) , Lens cover:Fiberglass reinforced plastic |
|||
Weight |
Approx. 40 g |
|||

Specifications
Model |
FD-GD32B |
|||
Pipe size/Outer diameter |
1 1/4" (32 A) ø41 to ø45 mm ø1.61" to ø1.77" |
|||
Lmin |
387 mm 15.24" |
|||
Lmax |
1100 mm 43.31" |
|||
Length x quantity in pack |
245 9.65" × 1 |
|||
Weight |
Approx. 0.3 kg |
|||

Specifications
Model |
GL-SS3 |
|||
Type |
Standard cable |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
1 |
|||
Cable end |
Main unit connection connector - Main unit connection connector |
|||
Length |
3 m 9.84' |
|||
Note |
Use this with one-line systems and series connections. |
|||
Weight |
100 g |
|||


Specifications
Model |
FD-EPH10 |
|||
Pipe size |
Outer diameter of pipe |
ø10 0.39" *1 |
||
Compatible outer diameter range |
Polyurethane |
10.0 ±0.15 mm |
||
Nylon |
10.0 ±0.08 mm |
|||
Pipe materials |
Resin pipe connectible to a one-touch coupling |
|||
Supported gases |
Air, nitrogen, argon, and non-corrosive gases*2 |
|||
Supported gas temperature |
−10°C to +60°C 14 to 140°F |
|||
Pressure resistance |
1 MPa |
|||
Flow rate detection principle |
Ultrasonic transmission time difference method |
|||
Flow rate specifications |
Rated flow rate |
(volume flow rate) |
150 L/min 5.30 CFM |
|
(20°C 68°F, atmospheric pressure conversion) * Initial display |
Gas at 20°C 68°F, 0.0 MPa |
|||
Gas at 20°C 68°F, 0.2 MPa |
450 L/min 15.9 CFM |
|||
Gas at 20°C 68°F, 0.4 MPa |
750 L/min 26.5 CFM |
|||
Gas at 20°C 68°F, 0.6 MPa |
1050 L/min 37.1 CFM |
|||
Measurement accuracy |
±(2.0% of RD+1.0% of F.S.)*3*4 |
|||
Repeatability |
Response time of 250 ms: ±2.5% of F.S.*3*5 |
|||
Pressure specifications |
Rated pressure |
−100 kPa to +0.75 MPa * However, the flow rate cannot be measured in the range of −100 to −30 kPa. |
||
Overall accuracy |
±2.0% of F.S.*3 |
|||
Repeatability |
Response time of 2.5 ms: ±0.4% of F.S. |
|||
Display resolution |
Instantaneous flow |
0.1/1 L/min |
||
Accumulated flow |
0.1/1/10/100/1000 L |
|||
Pressure |
0.1/1 kPa |
|||
Environmental resistance |
Enclosure rating |
IP65 (IEC60529) |
||
Ambient temperature |
−10°C to +60°C 14 to 140°F (no freezing) |
|||
Relative humidity |
35%RH to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral concentration: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Sensor unit (parts that do not contact the gas) |
PBT/PAR/iron/Brass electroless nickel plating/POM/NBR/stainless steel/aluminum |
||
Flow channel (parts that contact the gas) |
PBT/Brass electroless nickel plating/NBR/nylon |
|||
Weight |
Approx. 180 g 6.35 oz |
|||
*1 To ensure stable detection, it is recommended to use a pipe inner diameter that is at least equivalent to the inner diameter of this product. | ||||

Specifications
Model |
SV2-C5AG |
|||
Type |
Motor power cable, Hi-flex robotic cable |
|||
Length |
5 m 16.4' |
|||
Note |
for 50 W / 100 W motor |
|||

Specifications
Model |
GL-SA24F |
|||
Type |
Protection cover Flat type for 24 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S24FH |
|||
Number included |
1 |
|||
Length |
502.6 mm 19.79" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
160 g |
|||