Keyence Stock Image
Keyence DL-RB1 Keyence
Sale price 8,997.00 kr
Only 1 unit left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence OP-88884 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence SV2-M020AS Keyence
Sale price 3,920.00 kr
Only 3 units left

Specifications

Model

SV2-M020AS

General specifications

Applicable servo amplifier

SV2-020L2

Rated output

200 W

Rated torque

0.637 N·m *1

Instant maximum torque

2.23 N·m

Rated current

1.6 Arms

Instant maximum current

5.8 Arms

Rated rotation speed

3000min-1

High rotation speed

6000 min-1

Torque constant

0.444 N·m/Arms

Rotor moment of inertia

0.263 ×10-4kg·m2

Rated power rating

15.4 kW/s

Rated angle acceleration

24200 rad/s2

Excitation method

Permanent magnet

Position/speed detection encoder

Resolution

22 bits

Type

Absolute (ABS) type

Operating environment

Enclosure rating

Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area)

Operating ambient temperature

0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more)

Storage ambient temperature

-20 to +60°C -4 to +140°F

Operating/storage ambient temperature

20 to 80% RH (no condensation)

Operating atmosphere

Indoors (no corrosive gas, flammable gas, oil mist, or dust)

Altitude

2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more)

Vibration rank

V15

Vibration resistance

49 m/s2 160.8'/s2 with servo motor flange surface as reference (3 directions: up/down, left/right, forward/backward)

Impact resistance

490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times

Isolation rank

UL: phase A, CE: phase B

Min. insulation resistance

500 VDC, 10 MΩ or more with insulation resistance tester

Isolation voltage tolerance

1500 VAC for 1 minute

Approved standards

UL/CSA standards

UL1004-1, UL1004-6, CSA C22.2 No.100

CE marking

Low-voltage directive

EN60034-1, EN60034-5

EMI

EN55011 Class A, EN61800-3, EN61000-6-4

EMS

EN61800-3, EN61000-6-2

North America EMI standard

FCC Part15 B, ICES-003. Class A

Allowable load inertia moment

15 ×

Approx. weight

0.8 kg

*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink.
1 kW to 5 kW rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 400 × 400 × 20 mm 15.75" × 15.75" × 0.79" (1 kW to 2 kW) or 550 × 550 × 30 mm 21.65" × 21.65" × 1.18" (3 kW to 5 kW) mountable aluminum heat sink.

Keyence Stock Image
Keyence CA-DQW40X Keyence
Sale price 33,743.00 kr
Only 5 units left

Specifications

Model

CA-DQW40X

Illumination method

Square lighting
LumiTrax lighting/Normal lighting
Constant current control mode
(1024-step digital gradation)

Response speed

1 ms or less

LED

Color

White

Number of LEDs

168

Dimension

490 mm × 490 mm × 81.8 mm
19.29" × 19.29" × 3.22"(not including the connector)

Dimension

Inner Diameter

400 mm × 400 mm 15.75" × 15.75"(not including the connector)

Controller Connection

I/F

12-pole circular connector (dedicated cable)

Cable

Dedicated cable (3 m 9.8', 5 m 16.4', 10 m 32.8'),
30 m 98.4' max. (when using extension cables*1)

Illumination Expansion Unit

CA-DC60E

Connection with External Power Supply

I/F

3-pole circular connector (dedicated cable)

Cable

Dedicated cable (2 m 6.6', 5 m 16.4', 10 m 32.8')*2

Power voltage

24 VDC +25%, -20%

Power consumption

156W(8.1A)(current consumption)

Environmental resistance

Ambient temperature

0 to +40°C
32°F to 104°F

Relative humidity

85%RH or less (No condensation)

Weight

Approx. 3.0 kg

*1 Up to two extension cables can be connected to the dedicated cable.
*2 Connection can be extended up to 30 m 98.4' by using an AWG12 cable.

keyence Stock Image
Keyence OP-42105 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence CA-DZW45 Keyence
Sale price 42,161.00 kr
Only 2 units left

Specifications

Model

CA-DZW45

Type

Line Light

LED color

White

Power consumption

28.4 W*1

Input voltage

12 VDC

Weight

Approx. 1,280 g

*1 When using a line camera with the CA-DC21E & CA-DC40E, set light configuration to DC mode.

Keyence New Stock Image
Keyence LT-9011M Keyence
Sale price 49,287.00 kr
Only 7 units left
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
Keyence Stock Image
Keyence FU-71Z Keyence
Sale price 1,317.00 kr
Only 9 units left

Specifications

Model

FU-71Z*1

Optical axis diameter
(Standard target to be detected)

ø1.5 mm 0.06"

Size

M6

Fibre unit length

2 m 6.56', Free-cut

Fibre unit diameter

ø2.2 ø0.09"

Shape

Threaded

Minimum bend radius

R2 mm R0.08", ToughFlex

Environmental resistance

Ambient temperature

-40 to +50 °C -40 to 122 °F

Weight

Approx. 25 g

*1 For details on the detecting distance, see the fiber amplifier catalog.

Keyence Stock Image
Keyence XG-H200M Keyence
Sale price 6,502.00 kr
Only 5 units left
Buy the Keyence XG-H200M - a genuine Keyence industrial automation component engineered for reliable performance in demanding manufacturing and process control environments. The Keyence XG-H200M is a direct drop-in replacement for existing installations and ships ready for integration.
keyence Stock Image
Keyence OP-87772 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence IV3-MSD8G Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence ER-GM08P03C Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

ER-GM08P03C

Type

General-purpose all-metal shielded type Screw type M8 Connector with pigtail (M12 4-pin) PNP output Mid-Range

Power supply cable length

0.3 m 1.0' *1

No. of control outputs

2

Output mode

Output 1

N.O.

Output 2

N.C.

Button

None

Button

Function

Detecting distance

2 mm 0.08" ±10% *2

Response frequency

120 Hz *3 *4

Hysteresis distance

15% or less of detecting distance

Detectable object

Magnetic metal, Non-magnetic metal *5

Standard detectable object (Iron, t = 1 mm 0.04")

8 × 8 mm 0.31" × 0.31"

Temperature characteristics

±10% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F)
±15% or less of detecting distance at +25°C +77°F (+55 to +70°C 131°F to 158°F)

Control output

Open-collector, 30 VDC or less; 50 mA or less for 1 output; 50 mA or less in total for 2 outputs

Control output

Residual voltage

PNP output: 2.2 V or less (Output current: 10 mA or less) / 2.3 V or less (Output current: 10 to 50 mA) *6

Power supply

Power voltage

16 to 30 VDC (including 10% or less ripple (P-P)), Class 2

Power consumption (excluding load current)

750 mW or less (32 mA or less at 24 V, 47 mA or less at 16 V)

Protection circuit

Protection against reverse power connections, output short-circuits, and reverse output connections

Environmental resistance

Enclosure rating

IP67 (IEC60529), IP67G (JIS C 0920)

Ambient temperature

-25 to +70°C -13°F to +158°F (no freezing) *7

Relative humidity

Up to 95% RH (no condensation)

Vibration resistance

10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions

Shock resistance

500 m/s2 1640.4 ft/s2 (50 G),
10 times in each of the X, Y, and Z directions

Material

Detecting surface: SUS303, Mounting screw: SUS303, Case resin: PBT, Nut: SUS304, Toothed lock washer: SUS304
[Connector] Indicator: PBT (M8: LCP), Connector: PBT (M8: LCP), Case: SUS303
[Connector with pigtail] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC, Connector resin: TPU, Connector metal: Nickel-plated brass
[Cable] Indicator: TPU, Cable cap (M8 only): PBT, Cable: PVC

Accessories

Nut ×2, Toothed lock washer ×1

Weight

Approx. 40 g 1.41 oz

*1 Ensure the power cable is no longer than 30 m 98.4' for connector and connector with pigtail types.
*2 The distance at which a standard detectable object can be detected when the unit is mounted without being affected by surrounding metal.
*3 Value when a standard detectable object is used, the distance between detectable objects is twice the standard detectable object, and the distance to the detectable object is 1/2 the detecting distance.
*4 The response frequency varies depending on the operating temperature. The response frequency at temperatures of +55°C +131°F or higher is 50% of that at +25°C +77°F.
*5 Detecting distance varies according to the material and size. See the characteristic diagrams for details.
*6 Residual voltage is for when a 2 m 6.6' cable is used.
*7 The upper limit of the UL temperature rating is +55℃ +131℉.

keyence Stock Image
Keyence MB-HDX Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-88615 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88615

Length

0.1 m 0.3'

keyence Stock Image
Keyence OP-88969 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88969

Length

20 m 65.6'

keyence Stock Image
Keyence CA-DZR15 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

CA-DZR15

LED color

red

Power consumption

7.6 W

Weight

Approx 480 g

Keyence Stock Image
Keyence KV-C64XA Keyence
Sale price 8,275.00 kr
Only 8 units left

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

keyence Stock Image
Keyence PR-F51CN Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

PR-F51CN

Type

Thrubeam

Output

NPN

Shape

Flat

Cable connection

M8 connector (4 pin)

Detection distance

0.6 m

Number of control outputs

2

Output operation

Output 1

Dark-ON

Output 2

Light-ON

Response time

Output 1

0.5 ms

Output 2

ON→OFF: 2.7 ms, OFF→ON: 0.5 ms

Sensitivity adjustment

None

Spot diameter

-

Light source

4 element, point light source, red LED (650 nm)

Mutual interference prevention function

-

Indicator lamp

Output indicator (orange), stable operation indicator (green), thrubeam type transmitter: power supply indicator (green)

Control output

30 VDC or lower, 50 mA or lower
Leakage current:
When 3 kΩ load resistance, 0.3 mA or lower. When 1 kΩ load resistance, 0.5 mA or lower. When 0.2 kΩ load resistance, 1.5 mA or lower
Residual voltage:
When 10 mA or lower, 1.0 V or lower. When 10 to 30 mA, 1.5 V or lower. When 30 to 50 mA, 2.0 V or lower.

Protection circuit

Power supply reverse connection protection, output overcurrent protection,
output surge protection, power supply surge protection

Rating

Power voltage

10 to 30 VDC, including Ripple (P-P) 10 %

Current consumption

Transmitter: 11 mA, Receiver: 16 mA

Environmental resistance

Enclosure rating

IP67 (IEC60529), IP69K (DIN40050-9), 4X, 6P, 13 (NEMA250)

Insulation resistance

20 MΩ or higher (500 VDC)

Ambient light

Incandescent lamp: 5,000 lux or lower, Sunlight: 20,000 lux or lower

Ambient temperature

-25 to +55 °C -13 to 131 °F (No freezing)

Relative humidity

35 to 85 % RH (No condensation)

Storage temperature

-25 to +75 °C -13 to 167 °F

Withstand voltage

1,000 VAC, 50/60 Hz, 1 min

Vibration resistance

10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions

Shock resistance

1,000 m/s2, 6 times in each of the X, Y, and Z directions

Material

Case: SUS316L, indicator cover/lens cover: polysulfone,
cord protector: polymethylpentene, filler: polyester-based resin

Accessories

Instruction Manual

Weight

Approx. 20 g

keyence Stock Image
Keyence BT-HMT2 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence IV4-500MA Keyence
Sale price 47,240.00 kr
Only 5 units left

Specifications

Model

IV4-500MA

Type

Standard model

Installed distance

From 50 mm 1.97" *1

Tools

Available modes

Standard Mode, Sorting Mode, AI Through Count Mode

Tool with standard mode

Standard/Sorting Modes: AI Differentiate, Outline, ColorArea *2, Area *3, EdgePixels, ColorAverage *2, Brightness Avg *3, Width, Diameter, Edge Presence, Pitch,
Color Prohibit, Position Adjustment, Hi-Sp. Adj (1-axis/2-axis), Blob Count, AI Identify, AI Count, Total, AI OCR, AI Trigger
AI Through Count Mode: Count, Total

Number of tools

65 tools *4

Field of view

Installation distance 50 mm 1.97": 22 (H) × 16 (V) mm to
Installation distance 3000 mm 118.11": 1184 (H) × 888 (V) mm
(reference value)

Switch settings (programs)

128 programs (with SD card)/32 programs (without SD card)

Image receiving element

Type

1/2.9 inch monochrome CMOS

Number of pixels

1280 (H) × 960 (V)

Image history

Number of storable images

100 images *5

Save conditions

Logging Settings 1: NG only/OK near NG threshold *6/All – selectable. Logging Settings 2: Manually configured number before/after NG/Fixed interval – selectable *5

Focus adjustment

Auto *7

Image data transfer

Transfer destination

microSD card/FTP server/SFTP server – selectable

Transfer format

BMP/JPEG/iv4p/txt: Selectable, file name can be changed

Transfer conditions

OK/NG/NG and OK near threshold *6/OK near threshold *6/All/Judgment Complete – selectable

Exposure time

12 μs to 10 ms *8

Analysis information

RUN display

Tool-specific list (judgment results, match, match bar display) *9

RUN information

Switchable between OFF/histogram/processing time/count/output monitor
Histogram: Histogram, match (MAX, MIN, AVG), OKs, NGs
Processing time: Processing time (latest value, MAX, MIN, AVG), cap. time (latest value, MAX, MIN, AVG)
Count: No. of triggers, OKs, NGs, no. of trigger errors, Output monitor: Output-specific ON/OFF status *9

Lights

Illumination

Infrared LED

Lighting method

Pulse lighting

Other functions

Image capture function

Digital zoom (×2, ×4), HDR, high gain, color filters *2, white balance *2, brightness correction, Smart Image Optimization, preliminary capture, trapezoidal shape correction, mirror inversion correction
Capture range settings (with high-speed filter disabled: 1280×960, 640×480, 320×240, 160×120. With high-speed filter enabled: 640×480, 320×240, 160×120, 80×60)

Tool functions

Additional Learning (AI Differentiate, AI Identify, AI OCR, AI Count, AI Trigger. AI Through Count Mode: Count), remove outline, masking function, color extraction/exclusion *2, color histogram function *2, monochrome histogram function *3, scaling function

Utilities

List of NG sensor occurrences, NG hold, test run, I/O monitor, security settings (2-step password, Enhanced Security Mode), simulator *10, adding FTP image information, multiple position adjustment, adding multiple masters,
high-speed program switching, automatic program switching, automatic settings backup/restore, mid-operation threshold changes, excessive input trigger time detection

Indicators

OUT, TRIG, STATUS, LINK/ACT, SD

Input

Type

Switchable between non-voltage input/voltage input
For non-voltage input: ON voltage 2 V or lower, OFF current 0.1 mA or lower, ON current 2 mA (short circuit)
For voltage input: Maximum input rating 30 V, ON voltage 18 V or higher, OFF current 0.15 mA or lower, ON current approx. 2 mA (at 24 V)

Number of inputs

6, 3 of which are selectable between IN/OUT

Function

IN1: External trigger. IN2, IN3, I/O1 to I/O3: Assign any desired function.
Assignable functions: Program switching, error clear, ext. master image registration, SD card save stop, OCR serial no. increment, reset

Output

Type

Open collector output: Switchable between NPN/PNP and N.O./N.C.
Maximum rating: 30 V, 50 mA, residual voltage 1.5 V or lower *11

Number of outputs

6, 3 of which are selectable between IN/OUT

Function

Assign any desired function.
Assignable functions (Standard/Sorting Mode): Total status (OK/NG), operation, busy, trigger ready, strobe, position adjustment result, tool-specific judgment results, tool-specific logic calculation results,
error, SD card error, parts judgment results, master judgment results, insufficient SD capacity, file transfer in progress, AI Trigger output
Assignable functions (AI Through Count Mode): Operation, busy, error, tool-specific count up, tool-specific judgment result, tool-specific logic calculation result

Power/I/O

Connector

M12 12-pin A-code male connector

PoE

PoE Power Class 4/6 *12

Ethernet

Standard

1000BASE-T/100BASE-TX

Connector

M12 8-pin X-code female connector

Network function

FTP client, SFTP client, SNTP client, OPC UA server, MQTT client

Interface compatibility

Built-in Ethernet

EtherNet/IP, PROFINET CC-B *13, TCP/IP Nonprocedural Comm (×2 connections)

Communication unit (IV4-CU1)

PROFINET CC-C *14, EtherCAT®

Expanded memory

microSD card (microSD/microSDHC) *15

Power supply

Power voltage

24 V +25%, -20% (including ripple) *16

Power consumption

3.4 A or less (at 19.2 V), 2.7 A or less (at 24.0 V)(no AI imaging illumination unit; with communication unit; includes 120 mA output load)
3.3 A or less (at 19.2 V), 2.6 A or less (at 24.0 V)(no AI imaging illumination unit; no communication unit; includes 120 mA output load)
2.1 A or less (at 19.2 V), 1.8 A or less (at 24.0 V)(with AI imaging illumination unit; with communication unit; includes 120 mA output load) *17

Average power consumption

9.3 W (without AI imaging illumination unit)
12.8 W (with AI imaging illumination unit)

Environmental resistance

Enclosure rating

IP67 *18

Ambient temperature

0 to +50°C 32 to +122°F (no freezing) *19

Relative humidity

85% RH or less (no condensation)

Vibration resistance

Frequency: 10 to 500 Hz;
Power spectral density: 0.816 G2/Hz; X, Y and Z directions
*20

Shock resistance

500 m/s2 1640.4 ft/s2 3 times in each of 6 directions *20

Material

Main unit case: Aluminum die-casting. Front cover: Acrylic (hard coating). Back plastic cover and plastic lid: PBT. Operation indicator cover: TPU.
Power supply connector: PA/POM. Ethernet connector: Copper alloy + nickel plating. Label: PC.
Power supply connector waterproof cap: PC + ABS alloy. Ethernet connector waterproof cap: PC
*21

Weight

Approx. 370 g 13.06 oz (no AI imaging illumination unit)
Approx. 560 g 19.77 oz (with AI imaging illumination unit)

*1 If using at 3 m 9.8' or more, it is recommended that the polarizing filter be removed before use.
*2 Color type only.
*3 Monochrome type only.
*4 Can be placed on a program-specific basis. This is the total combined number of differentiation tools and position adjustment tools. Up to 64 differentiation tools can be placed. Up to 16 AI Count/AI OCR tools can be placed. In Sorting Mode, 8 differentiation tools can be placed. In AI Through Count Mode and High Speed/Standard Mode, the number of tools that can be placed is two AI Count tools and one Total tool. For high accuracy, six AI Count tools and two Total tools can be placed.
*5 Saved to the sensor’s internal memory. Images saved to the sensor’s internal memory can be backed up to a PC using the PC software (IV-H1SN) or to a USB memory stick or microSD card plugged into the control panel (IV4-CP70) or Display Expansion Unit (IV4-DU10).
*6 AI Differentiate, AI Identify, AI OCR(Show Matching Rate) only.
*7 Focus position can be automatically adjusted during installation. It cannot be adjusted while running. Focus position can be registered separately for each program.
*8 Maximum exposure time is 500 ms only when lighting is set to OFF.
*9 Can be displayed on the control panel (IV4-CP70) or Display Expansion Unit (IV4-DU10), or via PC software (IV-H1SN).
*10 Can be used with PC software (IV-H1SN).
*11 Set total output to 120 mA or less. Residual voltage specifications apply to an output current of 20 mA or less. For an output current of 50 mA, the value is 2.0 V.
*12 For PoE-powered devices, IEEE802.3at Power Class 4 or higher is recommended when using AI imaging illumination units; IEEE802.3bt Power Class 6 or higher is recommended when an AI imaging illumination unit is not in use. When using PoE, device operation may be restricted due to power limitations.
*13 Conformance Class B, applicable protocols: LLDP, SNMP
*14 Conformance Class C, applicable protocols: LLDP, SNMP, MRP
*15 Use KEYENCE-recommended products.
*16 24 VDC +25%/−10% (including ripple) when using OP-88656 (10 m 32.8').
*17 The system is designed to lower its peak current when equipped with an AI imaging illumination unit. Without it, the peak current will be higher.
*18 Except when polarizing filters (OP-88640/OP-88641/OP-88644/OP-88645) are installed.
*19 When the operating ambient temperature exceeds 40°C 104°F, install in accordance with KEYENCE instructions, taking appropriate measures for heat dissipation to ensure that the case temperature does not exceed the rated 75°C 167°F. Refer to the instruction manual for more information.
*20 Except when dome attachment (IV3-D10) is installed.
*21 ESD safe and IEC61340-5-1 compliant.

keyence Stock Image
Keyence OP-88456 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-88456

Length

2 m 6.6'

Material

PVC

Weight

Approx. 60 g 2.11 oz

keyence Stock Image
Keyence CA-DSB15 Keyence
Sale price 12,551.00 kr
Only 3 units left

Specifications

Model

CA-DSB15

Type

Back Light

LED color

Blue

Power consumption

27.4 W

Input voltage

12 VDC

Weight

Approx. 320 g

keyence Stock Image
Keyence OP-89048 Keyence
Sale price0.00 kr
Sold Out
PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.
keyence Stock Image
Keyence OP-83200 Keyence
Sale price0.00 kr
Sold Out

Specifications

Model

OP-83200

Overview

Front protective cover protecting detection side of light curtain.

Applicable product

SL-V80H, SL-V40L

Number included

1 pcs.

Length

1,590.2 mm 62.61"

Material

Translucent plastic: Polycarbonate Black plastic: ABS

Note

To install this product on both the transmitter and receiver, 2 sets are required. Use the dimming filters (sold separately) by attaching them to the front protection cover. When the front protection cover is attached, the L-shaped mounting bracket (OP-42