Specifications
Model |
CB-B05LL |
|||
Type |
Extension cable L-shape connector (left) |
|||
Cable length |
0.5m 1.64' |
|||
Cable min. bending R |
22mm |
|||
Material |
PVC (jacketing) |
|||
Weight |
Approx. 70g |
|||

Specifications
Model |
ER-M045NC |
|||
Type |
Compact all-metal shielded type Cylindrical type ø4.5 Connector (M8 3-pin) NPN output |
|||
Power supply cable length |
― *1 |
|||
No. of control outputs |
1 |
|||
Output mode |
N.O. |
|||
Button |
None |
|||
Button |
Function |
― |
||
Detecting distance |
1.5 mm 0.06" ±10% *2 |
|||
Response frequency |
170 Hz *3 *4 |
|||
Hysteresis distance |
15% or less of detecting distance |
|||
Detectable object |
Magnetic metal, Non-magnetic metal *5 |
|||
Standard detectable object (Iron, t = 1 mm 0.04") |
5 × 5 mm 0.20" × 0.20" |
|||
Temperature characteristics |
±10% or less of detecting distance at +25°C +77°F |
|||
Control output |
Open-collector, 30 VDC or less, Max. 50 mA |
|||
Control output |
Residual voltage |
NPN output: 0.9 V or less (Output current: 10 mA or less) / 1.4 V or less (Output current: 10 to 50 mA) *6 |
||
Power supply |
Power voltage |
16 to 30 VDC (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
960 mW or less (40 mA or less at 24 V, 60 mA or less at 16 V) |
|||
Protection circuit |
Protection against reverse power connections, output short-circuits, and reverse output connections |
|||
Environmental resistance |
Enclosure rating |
IP67 (IEC60529) |
||
Ambient temperature |
-25 to +70°C -13°F to +158°F (no freezing) |
|||
Relative humidity |
Up to 95% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
|||
Material |
Head |
SUS316L |
||
Amplifier |
Header-to-amplifier cable: TPU, Case: PBT/TPU |
|||
Accessories |
― |
|||
Accessories | ||||
Weight |
Approx. 20 g |
|||
*1 Ensure the power cable is no longer than 30 m 98.4' for connector types and no longer than 20 m 65.6' with IO-Link connections. | ||||

Specifications
Model |
GL-SP10P1 |
|||
Type |
One-line systemdedicated cable |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
1 |
|||
Cable end |
Main unit connection connector - Loose wires |
|||
Output |
PNP |
|||
Number of core |
6 |
|||
Length |
10 m 32.81' |
|||
Weight |
250 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
BT-WUC81GA |
|||
Dedicated AC adapter specifications |
Input side |
100 to 240 VAC, 50/60 Hz |
||
Output side |
12 VDC, Max. 1.5 A |
|||
Dimensions |
Dedicated AC adapter specifications |
104 x 43 x 31 mm 4.09" x 1.69" x 0.12 |
||
Weight |
Approx. 125 g |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F (No freezing) |
||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Storage temperature |
-20 to +60 °C -4 to 140 °F (No freezing) |
|||
Storage relative humidity |
20 to 85 % RH (No condensation) |
|||
Accessory |
AC adapter (OP-88020)*1 |
|||
Dimensions |
86 × 96.8 × 105.3 mm |
|||
Weight |
Approx. 340 g |
|||
*1 A separate AC cable is required. | ||||

Specifications
Model |
LV-H35F*1 |
|||
Type |
Straight-beam coaxial |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
100 mm 3.94" |
||
TURBO |
200 mm 7.87" |
|||
SUPER |
450 mm 17.72" |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Case |
Fluoroplastic (PFA) |
||
O-ring |
Fluororubber |
|||
Lens cover |
Glass |
|||
Weight |
Approx. 80 g |
|||
*1 The cable minimum bend radius is 25 mm 0.98". | ||||

Specifications
Model |
MB-H2D3-DVD |
|||
Operating System |
Windows 10/7/Vista (SP1 or higher)/XP (SP3 or higher) *1 |
|||
Overview |
2D setting and editing software (focal distance, tilt correction, spot variation, distance pointer adjustment) |
|||
Supported languages |
Japanese, English, Chinese (Simplified) and German (Chinese supports the simplified Chinese display, but does not support Chinese input.) |
|||
*1 For Windows 10/7/Vista, the 32 bit and 64 bit version are available. For Windows XP, only the 32 bit version is available. | ||||

Specifications
Model |
FD-G125L |
|||
Pipe size |
DN (Diameter Nominal) |
100 A, 125 A |
||
NPS (Nominal Pipe Size) |
4", 5" |
|||
Outer diameter of pipe |
ø111 to 117 mm 4.37" to 4.61", ø138 to 144 mm 5.43" to 5.67" |
|||
Pipe thickness |
2.1 to 5.0 mm 0.08" to 0.2" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||
Rated velocity of flow range |
Up to 15 m/s |
|||
Actual flow rate range (typical) |
m3/h |
Pipe size 100 A: 470.0 |
||
L/min |
Pipe size 100 A: 7800 |
|||
CFM |
Pipe size 100 A: 280.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 100 A: 1326.34 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 100 A: 1681.49 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 100 A: 2036.63 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 100 A: 2391.78 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
Instantaneous flow rate |
0.1 m3/h, 1 L/min, 0.1 CFM |
||
Consumption/leakage amount |
0.1 m3, 1 L, 1 CF |
|||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||
Zero point error |
±0.15% of F.S.*2*6 |
|||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||
Hysteresis |
Variable |
|||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||
I/O wiring connection port |
M12 4-pin connector (male) |
|||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||
Communication interface |
USB |
USB 2.0 |
||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||
Connector |
M12 connector (female, D-code) |
|||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||
Events |
100 |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||
Relative humidity |
5 to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||
Mounting/damping bracket |
SUS304 |
|||
Weight |
Approx. 2.7 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. | ||||

Specifications
Model |
GL-SA24S |
|||
Type |
Protection cover Slim type for 24 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S24SH |
|||
Number included |
1 |
|||
Length |
502.6 mm 19.79" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
160 g |
|||

Specifications
Model |
TM-006 |
|||
Measuring range |
ø6 mm 0.24" |
|||
Minimum detectable object |
0.04 mm 0.001" |
|||
Transmitter/receiver distance |
60 mm 2.36" |
|||
Light source |
GaN Green LED |
|||
Measurement accuracy |
±0.5 µm ±0.000020" *1 |
|||
Repeatability |
±0.06 µm*2 |
|||
Sampling cycle (trigger interval) |
5.5ms (33ms at the initial setting)*3 |
|||
Environmental resistance |
Enclosure rating |
IP64*4 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter |
Approx 140 g |
||
Receiver |
Approx 340 g |
|||
Base |
Approx 220 g |
|||
*1 In a measurement area of 2 mm 0.08"× ø4 mm ø0.16" error when measuring width of KEYENCE standard object (glass calibration scale). | ||||


Specifications
Model |
OP-51626 |
|||
Overview |
Side-mounting bracket for the MS2-H50. This is used when directly fastening the main unit with screws. |
|||
Applicable product |
MS2-H50 |
|||
Weight |
Approx. 51 g |
|||



Specifications
Model |
GS-MB22 |
|||
Type |
Hinged door |
|||
Applicable model |
for GS-M9 Series |
|||
Frame size |
30 - 40 mm 1.18" - 1.57" |
|||
Weight |
Approx. 120 g 4.23 oz |
|||

Specifications
Model |
OP-84245 |
|||
Overview |
Front protective cover protecting detection side of light curtain. |
|||
Applicable product |
SL-V79FM, SL-V40HM, SL-V20LM |
|||
Number included |
1 pcs. |
|||
Length |
805 mm 31.69" |
|||
Material |
Translucent plastic: Polycarbonate Black plastic: ABS |
|||

Specifications
Model |
CA-H048MX |
|||
Image element |
Monochrome CMOS, 16× high-speed reading using square-pixel |
|||
Unit cell size |
4.8 µm × 4.8 µm 0.19 Mil × 0.19 Mil |
|||
Valid pixel count |
0.47 megapixel mode: 784 (H) × 596 (V), 0.31 megapixel mode: 640 (H) × 480 (V), 0.24 megapixel mode: 512 (H) × 480 (V) |
|||
Image size |
Equivalent to 1/3" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
195 MHz |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.022 to 1000 msec by specifying the following numerical inputs: |
|||
Lens mount |
C-mount |
|||
Environmental resistance |
Ambient temperature |
0 to 40°C 32 to 104°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 190 g (not including lens) |
|||



Specifications
Model |
WI-S1 |
|||
XY stage moving range |
X axis: 75 mm 2.95", Y axis: 50 mm 1.97" |
|||
XY stage tilt angle |
±2° |
|||
Z stage moving range |
Coarse movement: 64 mm 2.52", fine movement: 2.0 mm 0.08" |
|||
Dimensions(excluding moving parts) |
231 (W) x 408 (H) x 360 (D) mm 9.09" (W) x 16.06" (H) x 14.17" (D) |
|||
Weight |
Approx. 10 kg |
|||