Sysmac NX1P CPU with 24 Digital Transistor I/O (PNP) 1.5 MB memory EtherCAT (0 servo axes 4 PTP axes 16 EtherCAT nodes) EtherNet/IP and 1 serial option port

Sysmac NJ3 CPU 5MB memory built-in EtherCAT (4 servo axes in total 192 EtherCAT nodes) and EtherNet/IP

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LR-TB5000C |
|||
Type |
Cable with connector M12 |
|||
Detectable distance |
60 to 5000 mm 2.36" to 196.85"*1 |
|||
Spot diameter |
Variable |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 2 laser product |
|||
Mutual interference prevention function |
4 units (when using the interference prevention function) |
|||
Timer |
OFF/OFF delay/ON delay/One-shot |
|||
Response time |
1 ms/10 ms/25 ms/100 ms/1000 ms |
|||
I/O |
Control output |
NPN open collector/PNP open collector selectable |
||
Analog output |
Current output/Voltage output selectable |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge |
|||
Power voltage |
20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
|||
Current consumption |
50 mA or less (without load)*5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp/Sunlight: 10,0000 lux or less |
|||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: Zinc die cast (Nickel chrome plating), |
|||
Accompanying items |
Instruction manual, |
|||
Weight |
Approx. 160 g |
|||
*1 The range for displayable distance is from 50 to 5200. | ||||

Programmable Logic Controller (PLC) CPU unit with 4 motion control axes + 4 single-axis position control axes - 5MB (Program) + 1.5MB (variables; non-volatile) + 32MB (variables; volatile) memory capacity - DIN rail mounting

Specifications
Model |
GC-1000 |
|||
Input/output points |
Safety inputs |
16 |
||
Safety outputs |
6 |
|||
Safety relay output |
- |
|||
AUX outputs |
4 |
|||
Test outputs | ||||
Maximum number of connectable expansion units |
10*1 |
|||
Maximum number of connectable remote I/O modules |
4 |
|||
GC-Link ports |
2 ports |
|||
Safety input specifications |
Input device |
Contact output device or PNP output device |
||
Input type |
Type3 |
|||
ON level (voltage/current) |
Min. 11 V/2 mA |
|||
OFF level (voltage/current) |
Max. 5 V/1.5 mA |
|||
Short-circuit current |
Si 0 to 3: Approx. 5 mA |
|||
Protection circuit |
Surge protection circuit, wrong wiring protection circuit |
|||
Maximum cable length |
Max. 100 m 328.1' |
|||
Safety output specifications |
Output type |
PNP transistor output (DC-13, Type 0.5, Protected outputs)*2 |
||
Maximum load current |
500 mA |
|||
Residual voltage (during ON) |
Max. 2.0 V |
|||
Leakage current (during OFF) |
Max. 0.5mA |
|||
Maximum capacitive load |
0.5 µF |
|||
Load wiring resistance |
Max. 2.5Ω |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 30 m 98.4' |
|||
Safety relay output specifications |
Output type |
- |
||
Rated load (resistance load) | ||||
Rated load (inductive load) | ||||
Relay output mechanical life | ||||
Maximum cable length | ||||
B10d | ||||
Test output specifications |
Output type |
PNP transistor output*3 |
||
Maximum load current |
100 mA |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 100 m 328.1'*4 |
|||
AUX output specifications |
Output type |
Transistor output (PNP/NPN selectable by wiring) |
||
Maximum load current |
PNP: 100 mA, NPN: 20 mA |
|||
Residual voltage (during ON) |
Max. 2.0 V |
|||
Leakage current (during OFF) |
Max. 0.5 mA |
|||
Protection circuit |
Overcurrent protection circuit, reverse connection protection circuit |
|||
Maximum cable length |
Max. 30 m 98.4' |
|||
Communication interface |
USB |
USB2.0 |
||
Ethernet |
100BASE-TX |
|||
Network functionality |
EtherNet/IP™ *5, PROFINET, Modbus/TCP, MC protocol, UDP |
|||
Others |
LCD display |
1.77-inch color LCD |
||
Display buttons |
4 points (3 operation keys + 1 BACK key) |
|||
Applicable standards |
EMC |
EMS: IEC 61131-2/-6, EN61131-2/-6 |
||
Safety |
IEC 61508, EN 61508 SIL3 |
|||
Dimensions |
60×95×90 mm 2.36"× 3.74"×3.54" (W×D×H) |
|||
Power supply |
Power voltage |
24 VDC (-30 to +20%) Class 2 |
||
Power consumption |
Max. 200 mA |
|||
Environmental resistance |
Ambient temperature |
−10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
5 to 85% (No condensation) |
|||
Storage temperature |
−25 to +70 °C -13 to 158 °F (No freezing) |
|||
Operating altitude |
Max. 2000 m 6561.7' |
|||
Overvoltage category |
II |
|||
Pollution degree |
2 |
|||
Vibration resistance |
Frequency: 5 to 9 Hz, Half amplitude: 3.5 mm 0.14" |
|||
Shock resistance |
Acceleration: 150 m/s2, Operating time: 11 ms, 3 times each in X, Y, Z directions |
|||
Material |
Polycarbonate |
|||
Weight |
Approx. 260 g |
|||
*1 The bus extension unit “GC-B30” is not included in this number, and only one set of “GC-B30” can be used per setup. | ||||

Specifications
Model |
LV-NH110 |
|||
Type |
Area thrubeam, High power |
|||
FDA (CDRH) Part 1040.10 |
Class 1 Laser Product |
|||
IEC 60825-1 | ||||
Light source |
Visible red semiconductor laser, Wavelength: 660 nm |
|||
Detecting |
MEGA |
2000 mm 78.74" |
||
ULTRA | ||||
SUPER | ||||
TURBO | ||||
FINE | ||||
HSP | ||||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Case |
Glass reinforced plastic |
||
Lens cover |
Transmitter: Glass, Receiver: Polyarylate |
|||
Weight |
Approx. 75 g |
|||

Programmable Logic Controller (PLC) CPU unit with 4 single-axis position control axes - 5MB (Program) + 1.5MB (variables; non-volatile) + 32MB (variables; volatile) memory capacity - DIN rail mounting

Specifications
Model |
GT2-P12K*1 |
|||
Detection system |
Scale Shot System II, absolute (no tracking errors) type |
|||
Measuring range |
12 mm 0.47" |
|||
Resolution |
0.1 μm 0.004 Mil |
|||
Indicated accuracy |
1 µm 0.04 Mil (p-p)*2 |
|||
Measuring force |
Downward mounting |
1.0 N*3 |
||
Side mounting |
0.95 N*3 |
|||
Upward mounting |
0.9 N*3 |
|||
Sampling cycle |
4 ms |
|||
Mechanical response |
10 Hz*2 |
|||
Operation indicator light |
2-color LED (red, green) |
|||
Environmental resistance |
Enclosure rating |
IP67G (JIS)*4, IP67 (IEC), NEMA Type 13*4 |
||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2 (IEC60068-2-27) |
|||
Materials |
Main body |
Main body case: SUS 303, Status indicator: PET, Sensor head-relay connector cable: PUR, Relay connector: PBT |
||
Dust boot |
NBR |
|||
Contact |
SUS304, cemented tungsten carbide*5 |
|||
Sensor head cable |
Optional (connect to relay connector) |
|||
Weight |
Approx. 35 g (excluding cable)*6 |
|||
*1 Note: You may not be able to connect the sensor head to the amplifier unit depending on when the amplifier unit was purchased. For details, contact your local sales office. | ||||

Specifications
Model |
LR-TB2000C |
|||
Type |
Cable with connector M12 |
|||
Detectable distance |
60 to 2000 mm 2.36" to 78.74"*1 |
|||
Spot diameter |
Approx. ø4 mm ø0.16" |
|||
Light source |
Type |
Red laser (660 nm) |
||
Laser class |
Class 2 laser product |
|||
Mutual interference prevention function |
4 units (when using the interference prevention function) |
|||
Timer |
OFF/OFF delay/ON delay/One-shot |
|||
Response time |
1 ms/10 ms/25 ms/100 ms/1000 ms |
|||
I/O |
Control output |
NPN open collector/PNP open collector selectable |
||
Analog output |
- |
|||
Protection circuit |
Protection against reverse power connection, power supply surges, output overcurrent, reverse output connection, and output surge |
|||
Power voltage |
20 to 30 VDC, including 10% ripple (P-P), Class 2 or LPS |
|||
Current consumption |
45 mA or less (without load)*5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp/Sunlight: 10,0000 lux or less |
|||
Ambient temperature |
-20 to +55 °C -4 to 131 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
1,000 m/s2, 6 times in each of the X, Y, and Z directions |
|||
Material |
Case: Zinc die cast (Nickel chrome plating), |
|||
Accompanying items |
Instruction manual, |
|||
Weight |
Approx. 85 g |
|||
*1 The range for displayable distance is from 50 to 2200. | ||||

NX-series EtherNet/IP Coupler 2 ports supports local safety 63 I/O units max I/O current 10 A screwless push-in connector delivered with end cover