Specifications
Model |
OP-87286 |
|||
Type |
Adapter Rc1/2 Female |
|||
Overview |
Tee adapter can be connected to GP-M Series. The both sides are connectable to Rc1/2 female. |
|||
Applicable product |
GP-M Series sensor main unit |
|||
Number included |
1 pcs. |
|||
Connection port |
G3/4 female on pressure sensor side and Rc1/2 female x 2 on tube side |
|||
Material |
SUS304 |
|||

Specifications
Model |
FU-87K*1 |
|||
Heat resistant temperature |
200°C 392°F*2 |
|||
Fibre unit length |
1 m39.37" cannot be cut |
|||
Minimum bend radius |
R8 mm0.315" |
|||
Minimum detectable object |
Gold wire with a diameter of 0.005 mm0.0002" *3 |
|||
Environmental resistance |
Ambient temperature |
-40 to +200 °C -40 to 392 °F |
||
Weight |
Approx. 15 g |
|||
*1 For details on the detecting distance, see the fiber amplifier catalog. | ||||

Specifications
Model |
AH-110 |
|||
Type |
General-use sensor head |
|||
Amplifier unit |
AS-440-02 |
|||
Shape |
M10 threaded |
|||
Measuring range |
0 to 2mm0.08" |
|||
Analog output voltage |
Output voltage |
0 to 2V |
||
Straight line range |
― |
|||
Impedance |
100 Ω |
|||
Resolution |
0.1% of F.S. |
|||
Linearity |
±1% of F.S. |
|||
Response |
3.3 kHz (-3 dB) |
|||
Temperature |
Sensor head |
0.03% of F.S./°C*1 |
||
Temperature characteristics |
Amplifier unit |
0.05% of F.S./°C*1 |
||
Rating |
Power voltage |
110/120/220/240 VAC ±10 %, 50/60 Hz |
||
Power consumption |
5VA |
|||
Environmentalresistance |
Enclosure rating |
Sensor head |
IP67 |
|
Operating ambient temperature |
-10 to +60°C 14 to 140°F, No freezing |
|||
Amplifier unit |
0 to +50°C 32 to 122°F |
|||
Environmental resistance |
Relative humidity |
35 to 85 % RH (No condensation) |
||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Weight |
Sensor head |
Approx 55g |
||
Weight (including cord) |
Amplifier unit |
Approx 320g |
||
*1 When the distance between the sensor head and the target is within 50% of the measurement range. | ||||

Specifications
Model |
LS-C3A |
|||
Type |
Cable between the controller and measuring head |
|||
Applicable product |
LS-7000 series |
|||
Number included |
1 |
|||
Cable end |
Straight |
|||
Length |
3 m 9.8' |
|||
Note |
Up to two cables are connectable, provided that the total length is a maximum of 40 m 131.2'. |
|||
Weight |
Approx. 250 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
GV-H1000 |
|||
Type |
Ultra long-range |
|||
Light source |
Visible semiconductor laser, Wavelength: 655 nm |
|||
Laser class |
FDA (CDRH) |
Class 2 (560 µW) |
||
IEC 60825-1 | ||||
JIS C6802 | ||||
Detection distance |
200 to 1000 mm 7.87" to 39.37" |
|||
Possible display range |
810 to -175 |
|||
Standard detection deviation |
20 mm 0.79" (Detection distance |
|||
Spot diameter |
Approx. ø1.8 mm ø0.07" |
|||
Operation status indicators |
Control output: Red LED/Laser radiation emission indicator: Green LED/1 spot indicator: Green LED |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Operating ambientluminance |
Incandescent lamp |
5000ℓx |
||
Sunlight |
10000ℓx*2 |
|||
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z axis |
|||
Material |
Housing material: PBT, Display: Polyarylate, Metal: SUS304, Lens cover: Glass, Cable: PVC |
|||
Weight |
Approx. 210 g*3 |
|||
*1 General guideline for amplifier display values relative to detection distance (when distance display mode is set to normal). | ||||

Specifications
Model |
TM-040 |
|||
Measuring range |
ø40 mm 1.57" |
|||
Minimum detectable object |
0.3 mm 0.01" |
|||
Transmitter/receiver distance |
180 mm 7.09" |
|||
Light source |
InGaN Green LED |
|||
Measurement accuracy |
±2 µm 0.000079" *1 |
|||
Repeatability |
±0.15 µm ±0.000006" *2 |
|||
Sampling cycle (trigger interval) |
5.5ms (33ms at the initial setting)*3 |
|||
Environmental resistance |
Enclosure rating |
IP64*4 |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Material |
Aluminum |
|||
Weight |
Transmitter |
Approx 560 g |
||
Receiver |
Approx 720 g |
|||
Base |
Approx 630 g |
|||
*1 In a measurement area of 10 mm 0.39"× ø26 mm ø1.02" error when measuring width of KEYENCE standard object (glass calibration scale). | ||||

Specifications
Model |
OP-88292 |
|||
Type |
Sensor head-controller extension cable, 2 m 6.56 ' |
|||
Applicable product |
FD-XS1/XS8/XS20 |
|||
Length |
2 m |
|||
Note |
A cable that further extends the 2 m 6.56 ' cable between the sensor head's relay amp and the controller. |
|||
Weight |
Approx. 110 g |
|||

Specifications
Model |
OP-85499 |
|||
Overview |
This is a connector cable for the M8 connector sensor. This connector cable is made of polyurethane (PUR), which has excellent oil resistance. |
|||
Applicable product |
M8 connector for PZ-G standard (Rectangular) models |
|||
Number included |
1 pcs. |
|||
Cable end |
M8 straight - Loose wire |
|||
Length |
2 m 6.56' |
|||
Material |
Cable: Polyurethane (PUR) |
|||
Weight |
Approx. 65 g |
|||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
NR-500 |
|||
Type |
Interface unit |
|||
External calibration input signal |
Trigger input TRG IN |
Voltage input: 10 to 30 VDC, Min. pulse duration: 2 ms, Effective pulse width: 1 ms or more |
||
Synchronization input SYNC IN |
Voltage input: 5 VDC ±10%, Min. pulse duration: 20 µs, Effective pulse width: 10 µs or more |
|||
Control output |
Trigger output TRG OUT |
NPN open collector output: 1 ch, Maximum current: 100 mA (30 V or less), Residual voltage: 1 V or less, One-shot output |
||
Withstand voltage |
Between I/O and USB/DC IN/system bus |
1500 VAC (50/60 Hz) for 1 minute |
||
Between trigger input and output |
125 VAC (50/60 Hz) for 1 minute |
|||
PC interface |
USB |
USB Revision 2.0 High-speed–compliant (USB 1.1 compatible), |
||
Continuous collection speed |
Max. 100 kHz for all acquisition channels |
|||
No. of connectable measurement units |
8 units or less (not exceeding 20 W total measurement unit power) |
|||
Synchronization between measurement units |
±1 µs or less*1 |
|||
Time axis accuracy |
±50 ppm (23°C ±3°C 73.4°F ±5.4°F) |
|||
Power supply |
NR-U5 AC adapter or USB bus power (NR-TH08, NR-C512, NR-EN16 (no power output): when connecting one unit) |
|||
Rating |
Power consumption |
0.9 W or less |
||
Environmental resistance |
Ambient temperature |
0 to +40°C 32°F to 104°F |
||
Relative humidity |
10 to 85% RH (no condensation) |
|||
Weight |
Approx. 110 g 3.88 oz (including OP-51581: NR-500 5-pole terminal block) |
|||
*1 When using the NR-CA04 in combination with other unit types, the maximum sampling period is 40 ms or 1 sampling cycle, depending on the setting. | ||||



Specifications
Model |
OP-88294 |
|||
Type |
Securing bracket for plastic clamp set |
|||
Applicable product |
FD-XC1R1/XC1R2 |
|||
Material |
PPS |
|||
Note |
For securing the plastic clamp set to a jig, etc. Use when clamping to a soft plastic tube. |
|||
Weight |
Approx. 55 g |
|||

Specifications
Model |
GL-VM04LP |
|||
Beam axis spacing/Lens diameter |
40 mm 1.57": ø5 ø0.197" |
|||
Number of beam axes |
4 |
|||
Total length |
160 mm 6.30" |
|||
Detection height |
120 mm 4.72" |
|||
Protection height |
205 mm 8.07" |
|||
Minimum detectable object size |
ø45 mm ø1.77" *1 |
|||
Detecting distance |
0.3 to 15 m 1.0' to 49.2' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
4.1 |
|
OFF→ON |
45.7 *3 |
|||
All blocked→ON |
51.2 *4 |
|||
With channel A or B |
ON→OFF |
9.7 |
||
OFF→ON |
52.8 *3 |
|||
All blocked→ON |
65.5 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
54 *5 |
||
Receiver |
68 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
47 *5 |
||
Receiver |
55 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
120 g 4.23 oz |
||
Receiver | ||||
Total |
240 g 8.47 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||

Specifications
Model |
BT-CG35GA |
|||
Charging unit |
Charging time |
Approx 3 hours (at room temperature) |
||
Charging |
Confirmation LED |
2-color LED (red: charging, green: completed) |
||
Dedicated AC adapter specifications |
Input side |
100 to 240 VAC, 50/60 Hz |
||
Output side |
12 VDC, Max. 1.5 A |
|||
Dimensions |
Dedicated AC adapter specifications |
104 x 43 x 31 mm 4.09" x 1.69" x 0.12 |
||
Weight |
Approx. 125 g |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Storage temperature |
-20 to +60 °C -4 to 140 °F (No freezing) |
|||
Storage relative humidity |
35 to 85 % RH (No condensation) |
|||
Accessory |
AC adapter (OP-88020)*1 |
|||
Dimensions |
214 x 83 x 79.2 mm 8.43" x 3.27" x 3.12" |
|||
Weight |
Approx. 500 g |
|||
*1 A separate AC cable is required. | ||||

Specifications
Model |
AP-31KP |
|||
Type |
Negative pressure, PNP |
|||
Rated pressure |
0 to -29.9 inchHg |
|||
Fluid type |
Air or non-corrosive gases |
|||
Type of pressure |
Gauge pressure |
|||
Display |
3 1/2-digit, 2-color, 7-segment LED (Character height: 11 mm 0.43") |
|||
Display resolution |
0.1 inchHg, 0.1 kPa, 1 mmHg, 0.001 bar |
|||
Detectable pressure range |
-15 to +110 % of F.S. |
|||
Display temperature characteristic |
±1 % max. (of F.S.) of detecting pressure at 25 °C 77 °F (0 to 50 °C 32 to 122 °F) |
|||
Response time (Chattering prevention function) |
2.5/5/100/500 ms (selectable) |
|||
I/O |
Analog output |
1 to 5 V (Load impedance: 47 kΩ min.) |
||
Control output |
PNP open-collector 100 mA max. (30 V max.), Residual voltage: 1 V max. 2-output (N.O./N.C.selectable) |
|||
Rating |
Power voltage |
12 to 24 VDC ±10 % |
||
Current consumption |
50 mA (at 24 V) or less, 90 mA (at 12 V) or less |
|||
Environmental resistance |
Pressure resistance |
72.5 PSI |
||
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Front housing: Polyamide, Front panel sheet: PET, Rear housing: Polysulfone, |
|||
Weight |
Approx. 120 g |
|||


Specifications
Model |
GL-SA32S |
|||
Type |
Protection cover Slim type for 32 beam axes |
|||
Overview |
This protective case protects the main unit from impacts. |
|||
Applicable product |
GL-S32SH |
|||
Number included |
1 |
|||
Length |
662.6 mm 26.09" |
|||
Material |
aluminum |
|||
Note |
2 each of the following are included: hexagon socket head cap screw (width across flats: 3 mm), washer, and special hexagon socket head cap screw (M4, length: 13 mm, width across flats: 3 mm). |
|||
Weight |
210 g |
|||

Specifications
Model |
GL-SB02 |
|||
Type |
Intermediate support brackets for mounting to a flat surface |
|||
Applicable product |
GL-S Series main unit |
|||
Number included |
2 |
|||
Material |
SUS304 |
|||
Weight |
15 g |
|||

Specifications
Model |
KV-N16ETP |
|||
Expansion output unit |
Output Points |
16 points |
||
External connectionmethod |
MOSFET |
|||
External connection method |
Terminal block |
|||
Rated load |
30 VDC, 0.5 A |
|||
Leakage current (when output is OFF) |
100 μA or less |
|||
Residual voltage (at ON) |
0.8 VDC or less (with 0.5 A output) |
|||
ON resistance |
− |
|||
Common method |
16 points/1 common |
|||
Response time |
OFF to ON |
100 μs or less (with a load of 1 mA or more) |
||
ON to OFF |
200 μs or less (with a load of 1 mA or more) |
|||
Relay life |
− |
|||
Relay replacement | ||||
Internal current consumption |
40 mA or less |
|||
Weight |
Approx. 210 g |
|||
*1 If even a single overcurrent is detected, the protection operation (output turned OFF) and automatic recovery are repeated for all outputs within the shared common (The outputs within the shared common that are protected when an overcurrent is detected are outputs 000 to 007 or 008 to 015 for the case of the KV-N16ET(P).) , until the cause of the problem is removed. | ||||