Specifications
Model |
OP-35382 |
|||
Overview |
Cable for RS-232C communication. (includes communication cable 9-pin conversion connector). |
|||
Applicable product |
CV-100, CV-300, CV-500, CV-700 |
|||
Length |
3 m 9.84' |
|||

Specifications
Model |
EV-112MSO (2062) |
|||
Type |
Shielded |
|||
Shape |
M12 |
|||
Detecting distance |
2.5 mm 0.10" ±10% |
|||
Detectable object |
Ferrous metals (see Characteristics for nonferrous metals) |
|||
Standard target |
12 x 12 mm 0.47" x 0.47" |
|||
Hysteresis |
10% max. of detecting distance |
|||
Response frequency |
600 Hz |
|||
Operation mode |
N.O. |
|||
Temperature characteristics |
±10% max. of detecting distance at 23°C 73.4°F, |
|||
Control output |
5 to 200 mA |
|||
Protection circuit |
Reversed polarity, short-circuit, surge voltage |
|||
Cable length |
500 mm19.685" |
|||
Rating |
Power voltage |
12 to 24 VDC |
||
Current consumption (leakage |
Current consumption (leakage current): 1.0 mA max., Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Residual voltage |
Residual voltage: 3.6 V max. (with 2-m 6.6' cable) |
|||
Environmental resistance |
Enclosure rating |
IP67 |
||
Ambient temperature |
-25 to +80 °C -13 to 176 °F (No freezing) |
|||
Relative humidity |
35 to 95 % RH (No condensation) |
|||
Case material |
Nickel-plated brass |
|||
Weight |
Approx. 55 g |
|||

Specifications
Model |
CA-LMHE0510 *1 |
|||
Optical magnification |
×0.5 to ×1.0 |
|||
WD (at reference magnification) |
×0.5: 80.0 mm 3.15" |
|||
Compatible image sensor size |
4/3" (ø23 mm ø0.91") |
|||
Field of view |
20.5 mm × 25.5 mm to 10.2 mm × 12.8 mm 0.81" × 1.00" to 0.40" × 0.50" (With CA-HF2100x connected) |
|||
F-stop range (aperture) |
5.0 to 32 |
|||
Resolution |
×0.5: 6.7 μm 0.26 Mil |
|||
Resolving power |
Center/periphery: 120 cycles/mm |
|||
TV distortion |
0.10 % |
|||
Depth-of-field |
×0.5: 5.12 mm 0.20" |
|||
Mount |
C-mount |
|||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F |
||
Relative humidity |
80% RH or less (no condensation) |
|||
Weight |
Approx. 1050 g 2.31 lb |
|||
*1 Depending on factors such as the installation orientation and the vibrations of the environment, consider reinforcing the installation such as by implementing countermeasures to hold the lens in place. | ||||



Specifications
Model |
LV-H65 |
|||
Type |
Wide |
|||
FDA (CDRH) Part 1040.10 |
Class II |
|||
Light source |
Visible red semiconductor laser |
|||
Wavelength |
660 nm |
|||
Detecting distance |
FINE |
100 mm 3.94" (150 mm5.91")*1 |
||
TURBO |
10 to 150 mm 0.39" to 5.91" (10 to 250 mm 0.39" to 9.84")*1 |
|||
SUPER |
100 to 200 mm 3.94" to 7.87" (150 to 350 mm 5.91" to 13.78")*1 |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
||
Material |
Case |
Reinforced glass/plastic |
||
Lens cover |
Norbornene plastic |
|||
Reflective mirror |
Polycarbonate, acrylic |
|||
Weight |
Approx. 45 g |
|||
*1 The parentheses indicate the detecting distance when OP-51428 is used. | ||||

Specifications
Model |
DL-NS1 |
|||
Cable connector |
M12 Male |
|||
USB connector |
USB TypeA |
|||
USB Communication |
USB2.0 Full Speed |
|||
Interface |
USB-COM |
|||
OS |
Windows 11 Home/Pro/Enterprise (32bit/64bit) |
|||
Control input |
The number of input |
2 |
||
Input type |
Voltage input |
|||
Maximum rating |
26.4V |
|||
Minmum ON voltage |
DC15V |
|||
Maximum OFF current |
0.2mA |
|||
Control output |
The number of output |
2 |
||
Output type |
Photo relay output |
|||
Control output current |
30VDC 50mA max.per output |
|||
Maximum leak current |
0.1mA max. |
|||
Maximum residual voltage |
1V max. |
|||
Switch input |
Input type |
No-voltage input |
||
Supplied voltage |
Approx. 5V |
|||
Supplied current |
10mA max. |
|||
Power voltage |
USB bus power |
|||
Power consumption |
100mA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +50 °C 14 to 122 °F (No freezing) |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Main unit:Polycarbonate(PC)、Cable:PVC |
|||
Weight |
Approx. 45 g (including the cable) |
|||

Specifications
Model |
FT-H50 |
|||
Type |
Mid to low temperature, Ultra long-range |
|||
Rated temperature range |
32 to 932°F (0 to 500°C) *1 |
|||
Displayable temperature range |
-58 to +968°F (-50 to +520°C) |
|||
Detecting distance |
Unlimited *2 |
|||
Measuring distance / |
500/ø18 mm 19.69"/ø0.71" |
|||
Sight |
2-point visible laser beam *3 |
|||
Detecting element |
Thermopile |
|||
Detecting wavelength |
8 to 14 μm |
|||
Repeatability |
±5.4°F (±3°C) |
|||
Emissivity (ε) correction |
0.10 to 1.99 (0.01 step) |
|||
Environmental resistance |
Ambient temperature |
14 to 131°F (-10 to 55°C), No freezing |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, double amplitude: 1.5 mm 0.06", 2 hours in each of X, Y, and Z axis directions |
|||
Shock resistance |
500 m/s2, 10 times in each direction of each axis (X, Y, Z), 60 times in total |
|||
Material |
Case: Reinforced glass plastic, |
|||
Accessory |
Mounting bracket |
|||
Weight |
Approx. 150g |
|||
*1 Repeatability is guaranteed within the rated temperature range. | ||||

Specifications
Model |
CA-DQW15 |
|||
Type |
Square Light (Direct) |
|||
LED color |
White |
|||
Diffusion plate |
OP-87042*1 |
|||
Power consumption |
19.2 W*2 |
|||
Input voltage |
12 VDC |
|||
Weight |
Approx. 520 g |
|||
*1 These models are for a single bar. Four sets are required for the whole square. | ||||

Specifications
Model |
OP-88392*1 |
|||
Type |
Separate system |
|||
Length |
15 m 49.21' |
|||
Material |
PVC |
|||
Weight |
Approx. 600 g |
|||
*1 The unit connection cable for a vertical integrated system is included with the flow meter. | ||||



Specifications
Model |
GL-R24L |
|||
Detection capability |
ø1.77" ø45 mm |
|||
Total length |
37.80" 960mm |
|||
No. of beam |
24 |
|||
Detection height |
36.22" 920mm |
|||
Protection height |
39.57" 1005mm |
|||
Beam axis spacing/Lens diameter |
40 mm / ø5 1.57" / ø0.20" |
|||
Detecting distance |
0.66 to 49.21' 0.2 to 15 m*1 |
|||
Effective aperture angle |
Max. ±2.5° (When operating distance is 9.84' 3 m or more) |
|||
Light source |
Infrared LED (870 nm) |
|||
Response time (OSSD) (ms) |
Wire synchronization, One-line or |
ON→OFF |
7 |
|
OFF→ON |
49.3*2 |
|||
All blocked→ON |
64.9*3 |
|||
Optical synchronization system |
ON→OFF |
9.5 |
||
OFF→ON |
53*2 |
|||
All blocked→ON |
74.7*3 |
|||
Detection mode |
Turns on when no interruptions are present in the detection zone |
|||
Synchronization between the transmitter and receiver |
Optical synchronization or Wire synchronization (Determined by wiring) |
|||
Light interference prevention function |
Prevents mutual interference in up to two GL-R systems. |
|||
Control output |
Output |
2 transistor outputs. (PNP or NPN is determined by the cable type) |
||
Max. load current |
500 mA*4 |
|||
Residual voltage (during ON) |
Max. 2.5 V (with a cable length of 16.40' 5 m) |
|||
OFF state voltage |
Max. 2.0 V (with a cable length of 16.40' 5 m) |
|||
Leakage current |
Max. 200 µA |
|||
Max. capacitive load |
2.2 µF |
|||
Load wiring resistance |
Max. 2.5 Ω |
|||
Supplemental output |
AUX |
transistor outputs. (PNP or NPN is determined by the cable type) |
||
Error output | ||||
Muting lamp output |
Incandescent lamp (24 VDC, 1 to 5.5 W) |
|||
External input |
When using a PNP output cable |
EDM input |
ON voltage: 10 to 30 V |
|
When using an NPN output cable |
ON voltage: 0 to 3 V |
|||
Power supply |
Power voltage |
24 VDC ±20%, ripple (P-P) 10% or less, Class 2 |
||
Current |
Transmitter |
57 |
||
Receiver |
76 |
|||
Protection circuit |
Reverse current protection, short-circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC61496-1, EN61496-1, UL61496-1 |
|
EMI |
EN55011 ClassA, FCC Part15B ClassA, ICES-003 ClassA |
|||
Safety |
IEC61496-1, EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Overvoltage category |
II |
|||
Ambient light |
Incandescent lamp: 3,000 lux or less., Sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing) |
|||
Operating relative humidity |
15 to 85 % RH (No condensation) |
|||
Storage temperature |
-25 to +60 °C -13 to 140 °F (No freezing) |
|||
Storage relative humidity |
15 to 95 % RH |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 0.7 mm 0.03", 20 sweeps in each of the X, Y, and Z directions |
|||
Shock resistance |
100 m/s2 (Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions |
|||
Material |
Main unit case |
Aluminum |
||
Upper case/lower case |
Nylon (GF 30%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
1330 g |
||
Receiver |
1340 g |
|||
*1 When the option front protection cover is installed on the one of transmitter or receiver, the Operating distance is shorten by 1.64' 0.5 m. When the front covers are installed on both of the transmitter and receiver, the Operating distance is shorten by 3.28' 1.0 m. | ||||

Specifications
Model |
CA-H200M |
|||
Image element |
Monochrome CMOS, 7×/16× high-speed reading using square-pixel |
|||
Unit cell size |
4.5 µm × 4.5 µm 0.18 Mil × 0.18 Mil |
|||
Valid pixel count |
2 megapixel mode: 1600 (H) × 1200 (V), 1 megapixel mode: 1024 (H) × 960 (V) |
|||
Image size |
Equivalent to 1/1.8" |
|||
Scanning system |
Progressive |
|||
Pixel transfer frequency |
At 7× transfer speed: 86 MHz (43 MHz × 2)*1, At 16× transfer speed: 198 MHz*2 |
|||
Transfer system |
Digital serial transfer |
|||
Electronic shutter |
Can be set to 0.05 to 9000 msec by specifying the following numerical inputs: |
|||
Lens mount |
C-mount |
|||
Enclosure rating |
IP64*3 |
|||
Environmental resistance |
Ambient temperature |
0 to 45°C 32 to 113°F |
||
Relative humidity |
85% RH or less |
|||
Weight |
Approx. 75 g (not including lens) |
|||
*1 Transfer speed setting: Standard | ||||

Specifications
Model |
DL-RS1A*1 |
|||
Synchronization between the transmitter and receiver |
Asynchronous |
|||
Transmission code |
ASCII |
|||
Baud rate |
2,400/4,800/9,600/19,200/38,400 bps selectable (Factory-setting: 9,600 bps) |
|||
Data bit length |
8 bits/7 bits selectable (Factory-setting: 8 bits) |
|||
Parity check |
None/Even/Odd selectable (Factory-setting: None) |
|||
Stop bit length |
1 bit |
|||
Data delimiter |
Data reception: automatically recognizes CR or CR+LF |
|||
Indicator |
Communication indicator lamp (green x 2), Alarm indicator lamp (red), |
|||
Sensor |
Number of |
Up to 15 units (including main unit) |
||
Power voltage |
20 to 30 VDC, including ripple, Ripple (P-P): 10 % max. Class 2 (Supplied via connected sensor amplifier) |
|||
Power consumption |
25 mA max. |
|||
Environmental resistance |
Ambient temperature |
-10 to +55 °C 14 to 131 °F |
||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Material |
Case/Polycarbonate |
|||
Weight |
Approx. 53 g |
|||
Communication method |
Full duplex |
|||
*1 For connecting with sensor, please refer to the user's Manual | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.



Specifications
Model |
BT-WUC74GA |
|||
Dedicated AC adapter specifications |
Input side |
100 to 240 VAC, 50/60 Hz |
||
Output side |
16 VDC, Max. 3.75 A |
|||
Dimensions |
Dedicated AC adapter specifications |
102.5 x 42.5 x 28 mm 4.04" x 1.67" x 1.1" |
||
Weight |
Approx. 250 g |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F (No freezing) |
||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Storage temperature |
-20 to +60 °C -4 to 140 °F (No freezing) |
|||
Storage relative humidity |
20 to 85 % RH (No condensation) |
|||
Accessory |
AC adapter (OP-88149)*1 |
|||
Dimensions |
67.4 x 105.3 x 288.1 mm 2.65" x 4.15" x 11.34" |
|||
Weight |
Approx. 410 g |
|||
*1 A separate AC cable is required. | ||||

Specifications
Model |
OP-42198 |
|||
Type |
Long-distance reflector |
|||
Applicable product |
LV-H67 |
|||
Material |
Reflector: Acrylic, Base: ABS |
|||


Specifications
Model |
FD-G125 |
|||
Pipe size |
DN (Diameter Nominal) |
100 A, 125 A |
||
NPS (Nominal Pipe Size) |
4", 5" |
|||
Outer diameter of pipe |
ø111 to 117 mm 4.37" to 4.61", ø138 to 144 mm 5.43" to 5.67" |
|||
Pipe thickness |
3.1 to 6.8 mm 0.122" to 0.27" |
|||
Supported pipe materials |
Iron, steel, stainless steel |
|||
Supported fluids |
Air, Nitrogen, other gases*1 |
|||
Fluid temperature |
0 to 60ºC 32 to 140 °F |
|||
Recommended pressure |
0.4 MPa or greater (58 PSI or greater) |
|||
Rated velocity of flow range |
Up to 15 m/s |
|||
Actual flow rate range (typical) |
m3/h |
Pipe size 100 A: 470.0 |
||
L/min |
Pipe size 100 A: 7800 |
|||
CFM |
Pipe size 100 A: 280.00 |
|||
Standard flow rate range (typical) [CFM] |
20°C 68°F 60 psi 0.41 MPa |
Pipe size 100 A: 1326.34 |
||
20°C 68°F 80 psi 0.55 MPa |
Pipe size 100 A: 1681.49 |
|||
20°C 68°F 100 psi 0.69 MPa |
Pipe size 100 A: 2036.63 |
|||
20°C 68°F 120 psi 0.83 MPa |
Pipe size 100 A: 2391.78 |
|||
Display |
QVGA 2.2" LCD color monitor |
|||
Display update cycle |
Approx. 3 Hz |
|||
Display resolution |
Instantaneous flow rate |
0.1 m3/h, 1 L/min, 0.1 CFM |
||
Consumption/leakage amount |
0.1 m3, 1 L, 1 CF |
|||
Response time |
1.0 s/2.5 s/5.0 s/10.0 s/30.0 s/60.0 s/120.0 s/200.0 s (variable) |
|||
Measurement accuracy |
Between 10 and 100% of F.S. |
±2.0% of RD*2*3*4*5 |
||
Between 1 and 10% of F.S. |
±1.0% of F.S.*2*3*4*5 |
|||
Zero point error |
±0.15% of F.S.*2*6 |
|||
Static leakage repeatability |
±1.0% of RD*4*7 |
|||
Hysteresis |
Variable |
|||
Flow units |
CFM(S), CFM, m3/h (N), m3/h (S), m3/h, L/min (N), L/min (S), L/min |
|||
I/O wiring connection port |
M12 4-pin connector (male) |
|||
Detection mode (switchable) |
ch.1 |
Instantaneous flow mode/area mode/pulse (+) mode/integrated flow mode/warning mode (consump)*8 |
||
ch.2 |
Instantaneous flow mode/area mode/pulse (−) mode/warning mode (leak)/error output mode/analog output/integrated flow reset/flow rate zero input/origin adjustment input*8 |
|||
Standard I/O (switchable) |
Control output (ch.1/ch.2) |
NPN/PNP setting switchable, open collector output 30 VDC or less, max. 100 mA/ch, residual voltage: 2.5 V or less |
||
Analog output (ch.2) |
4 to 20 mA/0 to 20 mA, load resistance: 500 Ω or less |
|||
External input (ch.2) |
Short-circuit current: 1.5 mA or less, input time: 20 ms or more |
|||
Protection circuit |
Power supply reverse connection protection, power supply surge protection, short-circuit protection for each output, surge protection for each output |
|||
Analog input (for volume conversion) |
M8 4-pin connector (female), analog current input (4 to 20 mA), input resistance: 100Ω or less |
|||
Power supplied to pressure sensor |
Supply voltage: Equivalent to voltage applied to the FD-G, Supply current:70 mA or less (analog output of the pressure sensor included) |
|||
Communication interface |
USB |
USB 2.0 |
||
Ethernet |
Standard |
IEEE 802.3u (100BASE-TX) |
||
Transmission rate |
100 Mbps |
|||
Cable |
Category 5 or higher STP (shielded twisted pair) or UTP (unshielded twisted pair) cable |
|||
Connector |
M12 connector (female, D-code) |
|||
Network function |
Modbus TCP, EtherNet/IP™, IO-Link*9 |
|||
Recording capacity |
Consumption amount/ leakage amount |
Approx. 5 years |
||
Events |
100 |
|||
Power supply |
Power voltage |
20 to 30 VDC including 10% ripple (P-P), Class 2 |
||
Power consumption |
350 mA or less at 20 V, 290 mA or less at 24 V, 230 mA or less at 30 V (load current excluded) (analog output of the pressure sensor excluded), |
|||
Environmental resistance |
Enclosure rating |
IP65/67 (IEC 60529)*10 |
||
Ambient temperature |
Detection head: −10 to +60°C 14 to 140°F (no freezing), display unit: −10 to +55°C 14 to 131°F (no freezing) |
|||
Relative humidity |
5 to 85%RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz, power spectral density: 0.816 G2/Hz, XYZ axes |
|||
Shock resistance |
100 m/s2, 16 ms pulse, XYZ axes, 1000 times for each axis |
|||
Material |
Display unit |
Body: PBT + coating, display: PMMA, Power supply port: SUS304-equivalent, Ethernet port: zinc nickel plating |
||
Detection head |
Body: PPS/SUS304, rear surface: rubber |
|||
Mounting/damping bracket |
SUS304 |
|||
Weight |
Approx. 2.7 kg |
|||
*1 The gas must be uniform and capable of transmitting ultrasonic waves. Measurement may be unstable due to the pressure inside of the pipe and the type of gas. | ||||