Specifications
Model |
FL-CP140 |
|||
Total length (at 25 °C) |
1411 |
|||
Measurement range (dead zone excluded) |
1,357 (1,337)*1 |
|||
Weight |
Approx. 780 g |
|||
*1 Values for water. For oil | ||||

Specifications
Model |
GL-FB1400*1*2 |
|||
Length |
1429 mm 56.26" |
|||
Recommended compatible models |
GL-R95F / GL-R48H / GL-R24L |
|||
*1 It is also possible to install light curtains with a body length of 640 mm 25.20" or less. | ||||

Specifications
Model |
SJ-M030 |
|||
Type |
Head |
|||
Voltage application method |
Pulse AC method |
|||
Applied voltage |
±5.5 kV |
|||
Rated output voltage |
±6 kV |
|||
Ion balance control method |
I.C.C. method |
|||
Ion balance |
±30 V*1 |
|||
Supply pressure range |
0.2 MPa or less |
|||
Control input |
Static elimination stop input |
Non-voltage input |
||
Control output |
Alarm output |
NPN open collector 100 mA (40 V or less) |
||
Ion level alarm output | ||||
Condition alarm output | ||||
Effective length |
164 mm 6.457" |
|||
Total length |
220 mm 8.661" |
|||
Rating |
Power voltage |
24 VDC ±10 % |
||
Current consumption |
450 mA or less |
|||
Environmental resistance |
Ambient temperature |
0 to +40 °C 32 to 104 °F |
||
Relative humidity |
35 to 65 % RH (No condensation) |
|||
Weight |
Approx. 600 g |
|||
*1 Please make an inquiry as to the measurement condition. | ||||

Specifications
Model |
AP-V82W |
|||
Type |
Differential pressure type (DIN), NPN |
|||
Display |
2-level display with 4 1/2-digit, 7-segment LED (Character height: Upper level: 8 mm 0.32", red, Lower level: 5.7 mm 0.22", green) Alarm indicator: Red LED |
|||
Operation indicator |
Red LED x 3 (corresponding to control output 1 and 2) |
|||
Display resolution |
AP-10SK/AP-11SK: Standard mode 0.1inchHg, High-resolution mode 0.01inchHg |
|||
Power consumption |
Normal |
12V:1680mW(140mA) or less |
||
Eco mode |
12V:1200mW(100mA) or less |
|||
Hysteresis |
Variable (Standard: 0.5% of FS; high-resolution: 0.1% of F.S.) |
|||
Response time (Chattering prevention function) |
Selectable from 10, 100, 500 and 1000 ms |
|||
I/O |
Analog output |
4 to 20 mA, Maximum load resistance: 260Ω . |
||
Zero-shift input |
Input time of 20 ms or more. (or analog output selectable) |
|||
Bank input | ||||
Control output |
NPN (PNP) open collector x 2 channels (N.O./N.C. selectable), 40 VDC (30 VDC) max., 100 mA max. with residual voltage of 1 V max. |
|||
Rating |
Power voltage |
12 to 24 VDC Ripple (P-P) 10% or less |
||
Environmental resistance |
Ambient temperature |
-10 to +50°C (14 to 122°F), No condensation |
||
Relative humidity |
35 to 85%, No condensation |
|||
Vibration resistance |
10 to 55 Hz, 1.5 mm 0.06" double amplitude in X, Y, and Z directions, 2 hours respectively |
|||
Material |
Housing and cover: Polycarbonate, Keytop: Elastomer |
|||
Accessories |
AP-V80W (P) / V82W (P): DIN-rail mounting bracket, power cable, unit stickers |
|||
Weight |
Approx. 90 g |
|||
*1 Excluding the current for analog output Including the current for the sensor head | ||||

Specifications
Model |
ER-N10 |
|||
Type |
Separate amplifier Amplifier unit Expansion unit (zero line type) |
|||
No. of control outputs |
None *1 |
|||
No. of external inputs |
― |
|||
Temperature characteristics |
±8% or less of detecting distance at +25°C +77°F (-25 to +55°C -13°F to +131°F) *2 |
|||
Response time |
150 μs *3/ 300 μs *3/ 1 ms / 4 ms / 16 ms / 64 ms (switchable) |
|||
Network compatibility |
NU Series |
|||
Function |
Operation mode |
Normal / Magnetic metal / Non-magnetic metal / Hybrid |
||
Timer function |
Timer OFF / Off Delay / On Delay / One Shot / On-Off Delay / On-Delay One Shot |
|||
I/O |
Control output |
Open-collector, 30 VDC or less, PNP/NPN switchable |
||
External input |
Tuning / Detection stop / Zero shift / Hold value reset (switchable) |
|||
Additional expansion units |
Up to 8 units (9 units connected in total including the main unit); Up to 16 units when connecting an ER-N10 to an NU Series device |
|||
Protection circuit |
Protection against reverse power connection, output overcurrent, output surge, and reverse output connection |
|||
No. of mutual interference prevention units |
OFF / 4 units / 8 units (selectable) *4 |
|||
Power supply |
Power voltage |
18 to 30 VDC *5 (including 10% or less ripple (P-P)), Class 2 |
||
Power consumption (excluding load current) |
830 mW or less |
|||
Environmental resistance |
Ambient temperature |
Operation: -25 to +55°C -13°F to +131°F *6, Storage: -30 to 70°C -22°F to +158°F (no freezing) |
||
Relative humidity |
Operation/storage: Up to 85% RH (no condensation) |
|||
Vibration resistance |
10 to 500 Hz; Power spectral density: 0.816 G2/Hz; X, Y, and Z directions |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 (50 G), 10 times in each of the X, Y, and Z directions |
|||
Case material |
Main unit and cover: Polycarbonate, FG terminal: Copper/iron, Sheet metal: Aluminum alloy, M8 connector metal: Nickel-plated brass |
|||
Accessories |
Instruction manual |
|||
Weight |
Approx. 50 g 1.77 oz |
|||
*1 Counts as 1 output when connecting multiple units to the FS-MC8P/MC8N or NU Series. | ||||


Specifications
Model |
KV-NC20L |
|||
Transmission |
Electrical termination (Terminator) |
Set with the switch on the front panel of the main unit |
||
Baud rate |
1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 bps |
|||
Transmission method |
Port1 : Full duplex |
|||
Data format |
Start bit |
1 bit |
||
Data bits |
7 bits, 8 bits |
|||
Stop bits |
1 bits, 2 bits |
|||
Error detection |
Parity |
Even, odd, none |
||
RS/CS flow control |
Port1 : Enabled, disabled |
|||
Interface |
Communication standard |
Port 1 : RS-232C |
||
Connection |
Port 1 : D-sub 9-pin |
|||
Transmission |
Transmission distance |
Port1 : 15 m 49.2' |
||
Number of transmission units |
Port1 : 1 |
|||
Indication |
SD (orange), RD (orange) |
|||
Weight |
Approx. 110 g |
|||

Specifications
Model |
GS-P8LC1 |
|||
Type |
For extension (L-shaped) |
|||
Length |
1 m 3.3' |
|||
Weight |
Approx. 80 g 2.82 oz |
|||


Specifications
Model |
OP-96657 |
|||
Overview |
Connector cable for PZ2 thrubeam. It is printed as P-1S/P-2S. |
|||
Applicable product |
PZ2 Series thrubeam |
|||
Number included |
One for transmitter, the other for receiver. |
|||
Length |
2 m 6.56' |
|||

Specifications
Model |
SV2-B150AS |
|||
General specifications |
Applicable servo amplifier |
SV2-150L2 |
||
Rated output |
1.3 kW |
|||
Rated torque |
8.34 N·m *1 |
|||
Instant maximum torque |
23.3 N·m |
|||
Rated current |
10.7 Arms |
|||
Instant maximum current |
28 Arms |
|||
Rated rotation speed |
1500 min-1 |
|||
High rotation speed |
3000 min-1 |
|||
Torque constant |
0.891 N·m/Arms |
|||
Rotor moment of inertia |
22.0 ×10-4kg·m2 |
|||
Rated power rating |
31.6 kW/s |
|||
Rated angle acceleration |
3790 rad/s2 |
|||
Excitation method |
Permanent magnet |
|||
Position/speed detection encoder |
Resolution |
22 bits |
||
Type |
Absolute (ABS) type |
|||
Operating environment |
Enclosure rating |
Completely closed, self-cooling, IP67 standard (excluding connector and axis through-hole area) |
||
Operating ambient temperature |
0 to +60°C 32 to 140°F (reduced ratings at +40°C 104°F or more) |
|||
Storage ambient temperature |
-20 to +60°C -4 to +140°F |
|||
Operating/storage ambient temperature |
20 to 80% RH (no condensation) |
|||
Operating atmosphere |
Indoors (no corrosive gas, flammable gas, oil mist, or dust) |
|||
Altitude |
2000 m 6561.7' or less (reduced ratings at 1000 m 3280.8' or more) |
|||
Vibration rank |
V15 |
|||
Vibration resistance |
49 m/s2 160.8'/s2 with servo motor flange surface as reference (up/down, left/right) 24.5 m/s2 80.4'/s2 (forward/backward) |
|||
Impact resistance |
490 m/s2 1607.6'/s2 with servo motor flange surface as reference, 2 times |
|||
Isolation rank |
phase F |
|||
Min. insulation resistance |
500 VDC, 10 MΩ or more with insulation resistance tester |
|||
Isolation voltage tolerance |
1500 VAC for 1 minute |
|||
Approved standards |
UL/CSA standards |
UL1004-1, UL1004-6, CSA C22.2 No.100 |
||
CE marking |
Low-voltage directive |
EN60034-1, EN60034-5 |
||
EMI |
EN55011 Class A, EN61800-3, EN61000-6-4 |
|||
EMS |
EN61800-3, EN61000-6-2 |
|||
North America EMI standard |
FCC Part15 B, ICES-003. Class A |
|||
Allowable load inertia moment |
5 × |
|||
Approx. weight |
9 kg |
|||
Electromagnetic brake specifications |
Capacity |
10 W |
||
Rated voltage |
24 VDC +10%/-0% |
|||
Rated current (@20°C 68°F) |
0.41 A |
|||
Holding torque |
19.6 N·m |
|||
Release time |
100 ms *2 |
|||
Operating time |
80 ms *2 |
|||
*1 50 W to 750 W rated torque is continuously allowable with ambient temperatures of 40°C 104°F and 200 × 200 × 6 mm 7.87" × 7.87" × 0.24" (50 W / 100 W) or 250 × 250 × 6 mm 9.84" × 9.84" × 0.24" (200 W to 750 W) mountable aluminum heat sink. | ||||

Specifications
Model |
FS-V33P |
|||
Type |
2-output + 1-input with cable |
|||
Output |
PNP |
|||
Main unit/Expansion unit |
Main unit |
|||
Control output |
2 outputs |
|||
Monitor output (1 to 5 V) |
N/A |
|||
External input |
1 input |
|||
Connector |
― |
|||
Light source LED |
Red, 4-element LED (Wavelength: 640 nm) |
|||
Response time |
33 µs (HIGH SPEED) /250 µs (FINE) /500 µs (TURBO) /1 ms (SUPER TURBO) /4 ms (ULTRA TURBO) /16 ms (MEGA TURBO) |
|||
Output selection |
LIGHT-ON/DARK-ON (switch-selectable) |
|||
Display indicator |
Operation indicator: Red LED/Dual digital monitor: Dual 7-segment display, Preset Value (4-digit green LED indicator) and |
|||
Size |
30.3 mm (H) x 9.8 mm (W) x 71.8 mm (D) 1.19" (H) x 0.39" (W) x 2.83" (D) |
|||
Detection mode |
Light intensity (area detection possible, automatic sensitivity-tracking function provided)/ |
|||
Timer function |
OFF-delay timer/ON-delay timer/One-shot timer/ON-delay timer + OFF-delay timer/ON-delay timer + One-shot timer, selectable |
|||
Control output |
PNP open-collector 24 V, 100 mA max.*1 (main unit only)/20 mA max. (when the expansion unit(s) is connected), Residual voltage: 1 V max. |
|||
External inputy |
Input time: 2 ms (ON)/20 ms (OFF) min.*2 |
|||
Unit expansion |
Up to 16 expansion units can be connected (a total of 17 units). Note that the 2-output type should be counted as two units. |
|||
Number of interference prevention units |
Normal operation |
HIGHSPEED:0 FINE:4 TURBO/SUPER/ULTRA/MEGA:8台 |
||
Rating |
Power voltage |
12 to 24 VDC ±10 %, Ripple (P-P) 10 % or less |
||
Power consumption |
Normal: 830 mW max. (Using 24 V, 35 mA max., using 12 V, 45 mA max.)/ |
|||
Environmental resistance |
Ambient light |
Incandescent lamp: 20,000 lux max., Sunlight: 30,000 lux max. |
||
Ambient temperature |
-10 to +55 °C 14 to 131 °F (No freezing)*4 |
|||
Relative humidity |
35 to 85 % RH (No condensation) |
|||
Vibration resistance |
10 to 55 Hz, Double amplitude 1.5 mm 0.06", 2 hours in each of the X, Y, and Z directions |
|||
Shock resistance |
500 m/s2, 3 times in each of the X, Y, and Z directions |
|||
Case material |
Polycarbonate |
|||
Accessories |
N/A |
|||
Weight |
Approx. 80 g |
|||
*1 Total current of two outputs should be less than 100 mA. | ||||

Specifications
Model |
SV-D20D |
|||
Type |
Electromagnetic brake cable |
|||
Length |
20 m 65.6' |
|||
Note |
Applicable servo amplifier capacity: 1 k to 5 kW |
|||

Specifications
Model |
WI-001*1*2*3 |
|||
Reference distance |
18 mm 0.71" |
|||
Measurement range |
Z |
1.4 mm 0.06" (Standard Mode), 0.7 mm 0.03" (High Speed Mode) |
||
XY |
1 × 1 mm 0.04" × 0.04" |
|||
Minimum detection area |
4 × 4 µm 0.000157" × 0.000157" |
|||
Repeatability (height difference) |
0.1 µm 0.000004"*4 |
|||
Linearity (height difference) |
±2.8 µm 0.000110"(±0.2% of F.S., F.S. = 1.4 mm 0.06", +20 to +30°C +68 to +86°F)*5 |
|||
Light source for measurement |
Type |
Infrared SLD |
||
Center wavelength |
830 nm |
|||
Laser class (IEC60825-1) |
Class 3R |
|||
Output |
3.6 mW |
|||
Guide light source |
Type |
Red semiconductor laser |
||
Wavelength |
660 nm |
|||
Laser class (IEC60825-1) |
Class 1 |
|||
Output |
0.15 mW |
|||
Sampling frequency |
Internal Trigger |
133 ms (High Speed Mode), 266 ms (Standard Mode) |
||
External Trigger |
266 ms max. (High Speed Mode), 532 ms max. (Standard Mode)*6 |
|||
Environmental resistance |
Ambient light |
Incandescent lamp/fluorescent lamp: 5,000 lux max. |
||
Ambient temperature |
0 to +35 °C 32 to 95 °F |
|||
Relative humidity |
20 to 85 % RH (No condensation) |
|||
Weight |
Approx. 3,000 g |
|||
*1 The laser classification for FDA(CDRH) is implemented based on IEC60825-1 in accordance with the requirements of Laser Notice.The resolution of the height (distance from head reference plane to measurement workpiece) is 1 µm(*2). | ||||

Specifications
Model |
OP-87895*1 |
|||
Type |
Right-angle mirror for High-resolution, Telecentric Macro Lens |
|||
Number included |
1 |
|||
Environmental resistance |
Ambient temperature range |
0 to 50 °C 32 to 122 °F |
||
Weight |
Approx. 120 g |
|||
*1 Fix the right-angle mirror in place separately from the lens. The mirror cannot be fixed to the lens. During use, ensure that there is some space between the right-angle mirror and the lens. | ||||

Specifications
Model |
CL-P015G |
|||
Type |
Optical unit |
|||
Head |
CL-P015 *1 |
|||
Reference distance |
15 mm 0.59" |
|||
Reference measurement range |
Measurement range |
±1.3 mm ±0.05" |
||
Linearity |
±0.36 μm ±0.000014" *2 |
|||
High precision measurement range |
Measurement range |
±0.5 mm ±0.02" |
||
Linearity |
±0.28 μm ±0.000011" *2 |
|||
Resolution |
0.003 μm *3 |
|||
Spot diameter |
ø25 μm ø0.0010" |
|||
Laser class |
Optical unit |
Class I |
||
Sampling cycle |
100/200/500/1000 μs (Adjustable 4-stage) |
|||
Environmental resistance |
Enclosure rating |
Head |
IP67 (IEC60529) |
|
Ambient light |
Target surface illuminance: 30000 lux (Incandescent lamp) |
|||
Ambient temperature |
0 to 50°C 32 to 122°F |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Head |
10 to 57 Hz, double amplitude 1.5 mm 0.06"; 2 hours each for X, Y, and Z axes |
||
Optical unit |
10 to 57 Hz, double amplitude 0.3 mm 0.01"; 2 hours each for X, Y, and Z axes |
|||
Shock resistance |
15 G, 6 ms |
|||
Temperature characteristic |
Head |
0.005% of F.S./°C |
||
Optical unit |
0.015% of F.S./°C |
|||
Material |
Head |
Front: SUS, Rear: Aluminum |
||
Optical unit |
Polycarbonate |
|||
Weight |
Head |
Approx. 180 g 6.35 oz |
||
Optical unit |
Approx. 1600 g 3.53 lb |
|||
*1 Sensor head and optical unit are a matched pair. Not cross compatible. | ||||

PLC Direct is not an authorized distributor. We offer a broad range of in-stock products with minimal lead time.

Specifications
Model |
LV-S31 |
|||
Type |
Adjustable distance definite reflective |
|||
FDA (CDRH) Part 1040.10 |
Class 1 Laser Product |
|||
IEC 60825-1 | ||||
Light source |
Visible red semiconductor laser, Wavelength: 655 nm |
|||
Detecting |
MEGA |
50 to 200 mm 1.97" to 7.87" |
||
ULTRA | ||||
SUPER | ||||
TURBO | ||||
FINE | ||||
HSP | ||||
Environmental resistance |
Ambient temperature |
0 to +50 °C 32 to 122 °F (No freezing) |
||
Material |
Case |
Glass reinforced plastic |
||
Display |
Polycarbonate |
|||
Lens cover |
Transmitter lens: Norbornene plastic |
|||
Weight |
Approx. 75 g |
|||

Specifications
Model |
OP-88030 |
|||
Type |
For PUR (Polyurethane) cable |
|||
Applicable product |
OP-87636/87637 |
|||
Weight |
Approx. 3 g |
|||

Specifications
Model |
GL-RC10M |
|||
Type |
Extension Cable |
|||
Applicable product |
GL-R Series |
|||
Number included |
1 cable |
|||
Cable end |
M14 connector (12-pin female) - Loose wires |
|||
Length |
10 m 32.81' |
|||
Material |
Connector for extension: PVC/nickel-plated brass, Cable: PVC |
|||
Note |
Extension cable for the GL-R Series. Use this together with the main unit connection cable (for extension). |
|||
Weight |
Approx. 480 g |
|||

Specifications
Model |
IV4-500CA |
|||
Type |
Standard model |
|||
Installed distance |
From 50 mm 1.97" *1 |
|||
Tools |
Available modes |
Standard Mode, Sorting Mode, AI Through Count Mode |
||
Tool with standard mode |
Standard/Sorting Modes: AI Differentiate, Outline, ColorArea *2, Area *3, EdgePixels, ColorAverage *2, Brightness Avg *3, Width, Diameter, Edge Presence, Pitch, |
|||
Number of tools |
65 tools *4 |
|||
Field of view |
Installation distance 50 mm 1.97": 22 (H) × 16 (V) mm to |
|||
Switch settings (programs) |
128 programs (with SD card)/32 programs (without SD card) |
|||
Image receiving element |
Type |
1/2.9 inch color CMOS |
||
Number of pixels |
1280 (H) × 960 (V) |
|||
Image history |
Number of storable images |
100 images *5 |
||
Save conditions |
Logging Settings 1: NG only/OK near NG threshold *6/All – selectable. Logging Settings 2: Manually configured number before/after NG/Fixed interval – selectable *5 |
|||
Focus adjustment |
Auto *7 |
|||
Image data transfer |
Transfer destination |
microSD card/FTP server/SFTP server – selectable |
||
Transfer format |
BMP/JPEG/iv4p/txt: Selectable, file name can be changed |
|||
Transfer conditions |
OK/NG/NG and OK near threshold *6/OK near threshold *6/All/Judgment Complete – selectable |
|||
Exposure time |
12 μs to 10 ms *8 |
|||
Analysis information |
RUN display |
Tool-specific list (judgment results, match, match bar display) *9 |
||
RUN information |
Switchable between OFF/histogram/processing time/count/output monitor |
|||
Lights |
Illumination |
White LED |
||
Lighting method |
Switchable between pulse and continuous lighting |
|||
Other functions |
Image capture function |
Digital zoom (×2, ×4), HDR, high gain, color filters *2, white balance *2, brightness correction, Smart Image Optimization, preliminary capture, trapezoidal shape correction, mirror inversion correction |
||
Tool functions |
Additional Learning (AI Differentiate, AI Identify, AI OCR, AI Count, AI Trigger. AI Through Count Mode: Count), remove outline, masking function, color extraction/exclusion *2, color histogram function *2, monochrome histogram function *3, scaling function |
|||
Utilities |
List of NG sensor occurrences, NG hold, test run, I/O monitor, security settings (2-step password, Enhanced Security Mode), simulator *10, adding FTP image information, multiple position adjustment, adding multiple masters, |
|||
Indicators |
OUT, TRIG, STATUS, LINK/ACT, SD |
|||
Input |
Type |
Switchable between non-voltage input/voltage input |
||
Number of inputs |
6, 3 of which are selectable between IN/OUT |
|||
Function |
IN1: External trigger. IN2, IN3, I/O1 to I/O3: Assign any desired function. |
|||
Output |
Type |
Open collector output: Switchable between NPN/PNP and N.O./N.C. |
||
Number of outputs |
6, 3 of which are selectable between IN/OUT |
|||
Function |
Assign any desired function. |
|||
Power/I/O |
Connector |
M12 12-pin A-code male connector |
||
PoE |
PoE Power Class 4/6 *12 |
|||
Ethernet |
Standard |
1000BASE-T/100BASE-TX |
||
Connector |
M12 8-pin X-code female connector |
|||
Network function |
FTP client, SFTP client, SNTP client, OPC UA server, MQTT client |
|||
Interface compatibility |
Built-in Ethernet |
EtherNet/IP, PROFINET CC-B *13, TCP/IP Nonprocedural Comm (×2 connections) |
||
Communication unit (IV4-CU1) |
PROFINET CC-C *14, EtherCAT® |
|||
Expanded memory |
microSD card (microSD/microSDHC) *15 |
|||
Power supply |
Power voltage |
24 V +25%, -20% (including ripple) *16 |
||
Power consumption |
3.4 A or less (at 19.2 V), 2.7 A or less (at 24.0 V)(no AI imaging illumination unit; with communication unit; includes 120 mA output load) |
|||
Average power consumption |
9.3 W (without AI imaging illumination unit) |
|||
Environmental resistance |
Enclosure rating |
IP67 *18 |
||
Ambient temperature |
0 to +50°C 32 to +122°F (no freezing) *19 |
|||
Relative humidity |
85% RH or less (no condensation) |
|||
Vibration resistance |
Frequency: 10 to 500 Hz; |
|||
Shock resistance |
500 m/s2 1640.4 ft/s2 3 times in each of 6 directions *20 |
|||
Material |
Main unit case: Aluminum die-casting. Front cover: Acrylic (hard coating). Back plastic cover and plastic lid: PBT. Operation indicator cover: TPU. |
|||
Weight |
Approx. 370 g 13.06 oz (no AI imaging illumination unit) |
|||
*1 If using at 3 m 9.8' or more, it is recommended that the polarizing filter be removed before use. | ||||

Specifications
Model |
GL-VM119FP |
|||
Beam axis spacing/Lens diameter |
10 mm 0.39": ø4 ø0.16" |
|||
Number of beam axes |
119 |
|||
Total length |
1200 mm 47.24" |
|||
Detection height |
1180 mm 46.46" |
|||
Protection height |
1204 mm 47.40" |
|||
Minimum detectable object size |
ø14 mm ø0.55" *1 |
|||
Detecting distance |
0.3 to 12 m 1.0' to 39.4' *2 |
|||
Effective angular aperture |
Up to ±2.5° (3 m 9.8' or above) |
|||
Light source |
Infrared LED (850 nm) |
|||
Detection mode |
ON when all beam axes received |
|||
Synchronization method |
Optical synchronization |
|||
Interference prevention function |
Interference prevention up to 2 units by series connection and switch setting |
|||
Control output (OSSD output) |
Output type |
Transistor output ×2 (PNP/NPN) |
||
Maximum load current |
150 mA or less |
|||
Residual voltage (when ON) |
Up to 2.5 V (with 5 m 16.4' cable) |
|||
OFF voltage |
Up to 2.0 V (with 5 m 16.4' cable) |
|||
Leakage current |
Up to 0.8 mA |
|||
Maximum load capacity |
0.8 μF |
|||
Load wiring resistance |
Up to 2.5Ω |
|||
Protection circuit |
Power supply reverse connection protection, short circuit protection for each output, surge protection for each output |
|||
Approved standards |
EMC |
EMS |
IEC/EN61496-1, UL61496-1 |
|
EMI |
EN55011 Class A, FCC Part15B Class A, ICES-003 Class A |
|||
Safety |
IEC61496-1/EN61496-1, UL61496-1 (Type 4 ESPE) |
|||
Response time (OSSD) |
With channel 0 |
ON→OFF |
8.8 |
|
OFF→ON |
52.8 *3 |
|||
All blocked→ON |
65.3 *4 |
|||
With channel A or B |
ON→OFF |
29.0 |
||
OFF→ON |
82.5 *3 |
|||
All blocked→ON |
124.2 *4 |
|||
Inputs |
Short circuit current: Approx. 3 mA |
|||
Power supply |
Power voltage |
24 VDC -20/+25% 10% ripple (P-P) or less, class 2 |
||
Current consumption (at maximum) (mA) Indicator : Standard / Eco/ External control |
Transmitter |
141 *5 |
||
Receiver |
156 *5 |
|||
Current consumption (at maximum) (mA) Indicator : OFF |
Transmitter |
63 *5 |
||
Receiver |
70 *5 |
|||
Environmental resistance |
Enclosure rating |
IP65/IP67 (IEC60529) |
||
Ambient light |
Incandescent lamp: 3000 lux or less, sunlight: 20,000 lux or less |
|||
Operating ambient temperature |
-30 to +55°C -22 to +131°F (no freezing) *6 |
|||
Operating relative humidity |
Up to 95%RH (no condensation) |
|||
Storage temperature |
-30 to +70°C -22 to +158°F (no freezing) |
|||
Storage relative humidity |
Up to 95% RH |
|||
Overvoltage category |
ll |
|||
Vibration resistance |
5 to 150 Hz 1G 10 cycles each in X, Y, and Z axes |
|||
Shock resistance |
15 G 6 ms pulses 100 times each in X, Y, and Z axes |
|||
Material |
Main unit case |
Aluminum alloy |
||
Upper case/lower case |
PPS (GF40%) |
|||
Front cover |
Polycarbonate, SUS304 |
|||
Weight |
Transmitter |
780 g 27.53 oz |
||
Receiver |
790 g 27.88 oz |
|||
Total |
1570 g 55.42 oz |
|||
*1 The maximum operating speed of the detected object is 2.0 m 6.6'/s. | ||||